500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LM324Y Texas Instruments Quadruple Operational Amplifier 0-DIESALE visit Texas Instruments
LM324NSRE4 Texas Instruments Quadruple Operational Amplifier 14-SO 0 to 70 visit Texas Instruments
LM324KNSR Texas Instruments Quadruple Operational Amplifier 14-SO 0 to 70 visit Texas Instruments Buy
LM324ANSR Texas Instruments Quadruple Operational Amplifier 14-SO 0 to 70 visit Texas Instruments Buy
LM324NSR Texas Instruments Quadruple Operational Amplifier 14-SO 0 to 70 visit Texas Instruments
LM324ANSRG4 Texas Instruments Quadruple Operational Amplifier 14-SO 0 to 70 visit Texas Instruments

strain gauge amplifier lm324

Catalog Datasheet MFG & Type PDF Document Tags

strain gauge amplifier lm324

Abstract: 1kw full bridge converter design advantageous in handling this wide range of signals with good linearity due to this feature. Strain Gauge Bridge Amplifier The circuit below shows a simple strain gauge circuit with a gain of 100 (40 dB) and , W +5.0V 4 1kW 11 S.G.: Matched Strain Gauge elements 12kW 1.2MW Figure 16. Strain Guage Amplifier A variation on this particular idea is the remote strain gauge circuit , 1.2MW Two-wire, Twisted-pair Shielded Line Figure 17. Remote Strain Gauge http://onsemi.com
ON Semiconductor
Original

Current to voltage Converter 4-20mA using LM324

Abstract: Voltage to Current Converter 4-20mA LM324 note Using the N E /SA 5234 amplifier AN1651 APPLICATIONS EXAMPLES Instrumentation Strain Gauge Bridge Amplifier The circuit below shows a simple strain gauge circuit with a gain of 100 (40dB , < 5.9mV 25.6mV 46.6mV Vo 0.5V 2.50V 4.63V S.G.: M atched Strain Gauge elem ents Figure 17. Strain , this particular idea is the remote strain gauge circuit operating from a three wire line, one of which , Philips Semiconductors RF Communications Application note Using the NE/SA5234 amplifier
-
OCR Scan
NE5234 Current to voltage Converter 4-20mA using LM324 Voltage to Current Converter 4-20mA LM324 Voltage to Current Converter 4-20mA using LM324 simple LM324 COMPARATOR CIRCUIT DIAGRAM LM324 preamp circuit DIAGRAM LM324 NE577 NE578

Voltage to Current Converter 4-20mA using LM324

Abstract: strain gauge amplifier lm324 4.3k VO 1 ­ 3 1k 11 S.G.: Matched Strain Gauge elements 12k 1.2M SL00645 Figure 16. Strain Gauge Amplifier 1.2M +VCC 4.3k 4.3k 4 S.G. S.G. 2 12k 3 + , Instrumentation Strain Gauge Bridge Amplifier The circuit below shows a simple strain gauge circuit with a gain , SL00646 Figure 17. Remote Strain Gauge 4-6V DC + + ­ +3V ­ CMOS + 4V VR ­ , strain gauge circuit operating from a three wire line, one of which is the shield. This
Philips Semiconductors
Original
strain gauge amplifier lm324 circuit diagram bridge transducer 4-20ma using op BDX45 NE570 equivalent ne570 philips class d audio amp
Abstract: Instrumentation Amplifier USE 2N2222 AS DIODES. 9V Battery Powered Strain Gauge Signal Conditioner +9V â , amplifier which directly upgrades designs in the industry standard 14-pin DIP LM324/LM348/0P-11/4156 pin , somewhat better than) the LT1014 â'™s. â  Battery-Powered Precision Instrumentation Strain Gauge , , REPEAT AS REQUIRED. Strain Gauge Bridge Signal Conditioner +5V 0V-3.5V Opsiâ'" 350psi TECH , . Although supply current is only 350|iA per amplifier, a new output stage design sources and sinks in -
OCR Scan
LT1013/LT1014 LT1013 0P-07 LM324/LM348/0P-11/4156 MC1458/ LM158

lt10141

Abstract: LM324 50Hz Instrumentation Strain Gauge Signal Conditioners Thermocouple Amplifiers Instrumentation Amplifiers â  4mA-20mA , Precision Instrumentation Amplifier 9V Battery Powered Strain Gage Signal Conditioner 15k ~WV- I 0.068 , LT1014 is the first precision quad operational amplifier which directly upgrades designs in the industry standard 14-pin DIP LM324/LM348/0P-11/4156 pin configuration. It is no longer necessary to compromise , provided in the quad configuration. Although supply current is only 350j
-
OCR Scan
lt10141 LM324 50Hz hot wire anemometer LT1013 anemometer thermometer lm324 44018 ysi 2M-200K

motor speed lm358

Abstract: Platinum Resistance Temperature sensor LT1014CN Precision Instrumentation Strain Gauge Signal Conditioners Thermocouple Amplifiers Instrumentation , ) DCSCRIPTIOn The LT1014 is the first precision quad operational amplifier which directly upgrades designs in the industry standard 14-pin DIP LM324/LM348/0P-11/4156 pin configuration. It is no longer necessary , terminals are provided in the quad configuration. Although supply current is only 350/< A per amplifier, a , THERMOCOUPLES. ALL RESISTORS COLD JUNCTION COMPENSATION ACCURATE TO ±1°C FROM 0 °C - 60°C. USE 4TH AMPLIFIER
-
OCR Scan
motor speed lm358 Platinum Resistance Temperature sensor LT1014CN Vernitron ceramic filters YSI 44018 J-2N5434 LT1013ACH OP-221 3/LT1014 1N914 LTC1044 2N2219

LT1013

Abstract: mc1458 cpi Battery Powered Strain Gauge Signal Conditioner 15k +9V +9V 0.068 LT1014 + 3 1N4148 , 74C221 3k 13 + +9V 1 350 STRAIN GAUGE BRIDGE 13 0.068 6 8 + 10 TO A , LINEARITY FOR 4.000V OUT, REPEAT AS REQUIRED. 1013/14 TA15 Strain Gauge Bridge Signal Conditioner +5V , configuration. Although supply current is only 350µA per amplifier, a new output stage design sources and sinks , to (even somewhat better than) the LT1014's. Battery-Powered Precision Instrumentation Strain
Linear Technology
Original
mc1458 cpi rtd circuits with lt1014 rosemount TEMPERATURE SENSOR 118MF YSI 400 thermistor rosemount 118mf lt1043 LT1004 1N5821 2N5262 LT2078/LT2079 LT2178/LT2179

YSI 44007

Abstract: YSI 400 thermistor Strain Gauge Signal Conditioner 15k +9V +9V 0.068 LT1014 + 3 1N4148 4 ­ 2 , + 0.068 6 10 TO A/D 100k LT1014 9 14 8 + +9V 1 350 STRAIN GAUGE , OUT. SET SENSOR TO 400 °C. ADJUST LINEARITY FOR 4.000V OUT, REPEAT AS REQUIRED. Strain Gauge , configuration. Although supply current is only 350µA per amplifier, a new output stage design sources and sinks , to (even somewhat better than) the LT1014's. Battery-Powered Precision Instrumentation Strain
Linear Technology
Original
YSI 44007 lm324 4mA to 20mA transmitter LM358 output drive circuits phase reversal Vernitron TRANSDUCER Schaevitz differential pressure transducer ysi thermistor network 44201

LT1013 anemometer

Abstract: LM324 temperature controller operational amplifier which directly upgrades designs in the industry standard 14-pin DIP LM324/LM348/OP , SOURCE IMPEDANCES, USE 2N2222 AS DIODES. +5V 1013/14 TA07 9V Battery Powered Strain Gauge , 350 STRAIN GAUGE BRIDGE 13 0.068 6 8 + 10 TO A/D 100k LT1014 9 14 + , configuration. Although supply current is only 350A per amplifier, a new output stage design sources and sinks , to (even somewhat better than) the LT1014's. Battery-Powered Precision Instrumentation Strain
Linear Technology
Original
LM324 temperature controller how to use STRAIN GAUGE with lm358 LT1013 equivalent sine wave inverter circuit diagram 2N2222 NPN Transistor features pin configuration transistor 2N2222 LM324/LM348/OP-11/4156

thermometer lm324

Abstract: lt10141 Instrumentation Strain Gauge Signal Conditioners Thermocouple Amplifiers Instrumentation Amplifiers â  4mA-20mA , Precision Instrumentation Amplifier 9V Battery Powered Strain Gage Signal Conditioner 15k HIGH _iV/.iT , LT1014 is the first precision quad operational amplifier which directly upgrades designs in the industry standard 14-pin DIP LM324/LM348/0P-11/4156 pin configuration. It is no longer necessary to compromise , provided in the quad configuration. Although supply current is only 350/xA per amplifier, a new output
-
OCR Scan
LT10140 31080 Schaevitz lvdt IM021 4mA-20mA lm324 inverter OP-07
Abstract:   Battery-Powered Precision Instrumentation Strain Gauge Signal Conditioners Thermocouple Amplifiers , The LT1014 is the first precision quad operational amplifier which directly upgrades designs in the industry standard 14-pin DIP LM324/LM348/0P-11 /4156 pin configuration. It is no longer necessary to , . Although supply current is only 350/iA per amplifier, a new output stage design sources and sinks in , 0.2 Per Amplifier - 0.35 0.2 0.4 0.50 0.4 - - 0.35 0.55 mA This -
OCR Scan
LM324/LM348/0P-11 150/A/ 55/A/

PICO-31080

Abstract: YSI 44201 - Better than 0P-07,0.07pA/VHz nppucnnons Battery-Powered Precision Instrumentation Strain Gauge , DIODES. 9V Battery Powered Strain Gauge Signal Conditioner HIGH A V /A T STEPS. rru n e A B , OUT, R EP EA T A S REQ U IRED. Strain Gauge Bridge Signal Conditioner +5V 0 V - 3 .5 V Opsi , Amp (LT1013) DCSCRIPTIOn The LT®1014 isthefirst precision quad operational amplifier which directly upgrades designs in the industry standard 14-pin DIP LM324/LM348/0P-11/4156 pin configuration. It
-
OCR Scan
PICO-31080 YSI 44201 0P420

sensor rosemount 118mf

Abstract: Thermistor hot-wire Instrumentation Strain Gauge Signal Conditioners Thermocouple Amplifiers Instrumentation Amplifiers n 4mA , 350 STRAIN GAUGE BRIDGE 13 + 9V ­ 100k ­ 100k SAMPLED OPERATION GIVES LOW , LINEARITY FOR 4.000V OUT, REPEAT AS REQUIRED. 1013/14 TA15 Strain Gauge Bridge Signal Conditioner 5V , RESISTORS = 1% FILM. COLD JUNCTION COMPENSATION ACCURATE TO ±1°C FROM 0°C TO 60°C. USE 4TH AMPLIFIER FOR , in the quad configuration. Although supply current is only 350µA per amplifier, a new output stage
Linear Technology
Original
sensor rosemount 118mf Thermistor hot-wire CA3046 equivalent LM358 sine wave oscillator 4 to 20ma current source circuit diagram lm358 CD40164 LTC6081/LTC6082 LTC6078/LTC6079

IC LM741 timer circuit diagram

Abstract: how to use STRAIN GAUGE with lm358 to provide the 5V excitation for the strain gauge Amplifier A1 connected as an instrumentation amplifier raises the output of the strain gauge to a usable level while rejecting common-mode pickup A , circuitry as a resistive transducer which might be a strain gauge or a pot (Figure 3) As in the stable , 3 FIGURE 3 In this strain-to-frequency converter the converter's reference excites the strain gauge (or the optional pot) through buffer amp A2 This makes the circuit insensitive to changes in the
National Semiconductor
Original
IC LM741 timer circuit diagram 2n3565 equivalent transistor LM307 equivalent ics LM358 vs LM741 lm307 substitution LM351* op amp LM131

2n3565 equivalent transistor

Abstract: how to use STRAIN GAUGE with lm358 the strain gauge. Amplifier A1, connected as an instrumentation amplifier, raises the output of the strain gauge to a usable level while rejecting common-mode pickup. A potentiometer-type transducer , , which might be a strain gauge or a pot (Figure 3). As in the stable oscillator already described , excites the strain gauge (or the optional pot) through buffer amp A2. This makes the circuit insensitive , . (Continued) the op amp should be a type such as 1/2 LM358 or 1/4 LM324, which has a common-mode range
National Semiconductor
Original
lm331 strain gauge lm331 pulse width LM131 application note 2N3565 analog divider LM351

ci 74c14

Abstract: rosemount 118 mf   Battery Powered Precision Instrumentation Strain Gauge Signal Conditioners Thermocouple Amplifiers â , ) 4V 2V OV / T ' \ 6Vp-p INPUT, -1.5V TO 4.5V Gain 100 Amplifier 4V 2V OV V J LM324, LM358 , DCSCAIPTIOil The LT1006 is the first precision single supply operational amplifier. Its design has been , from strain gauges or thermocouples, and output can swing to within a few millivolts of ground. If , . For example, a 1mV input signal will cause the amplifier to set up in its linear region in the gain
-
OCR Scan
ci 74c14 rosemount 118 mf 118mf rosemount 118 Precision Sample and Hold LT1006ACH 250MQ 118MF TRWMAR-60 74C14 10CWVW 130-C/W

4 to 20ma current source circuit diagram lm358

Abstract: lm358 thermocouple k Instrumentation Strain Gauge Signal Conditioners Thermocouple Amplifiers 4mA-20mA Current Loop Transmitters , single supply operational amplifier. Its design has been optimized for single supply operation with a , includes ground to accommodate low ground-referenced inputs from strain gauges or thermocouples, and output , signal will cause the amplifier to set up in its linear region in the gain 100 configuration shown below, but is not enough to make the amplifier function properly in the voltage follower mode. Voltage
-
OCR Scan
lm358 thermocouple k lm358 thermocouple j lm358 thermocouple LM358 voltage to current converter OP-21 "pin compatible" VCM-13 C0MM0N-M00E
Abstract: Instrumentation Strain Gauge Signal Conditioners Thermocouple Amplifiers Instrumentation Amplifiers 4mA to , 1013/14 TA07 9V Battery Powered Strain Gauge Signal Conditioner 15k 9V 47µF 9V 0.068 , + 9V 1 350Ω STRAIN GAUGE BRIDGE 13 + 9V â'" 100k â'" 100k 5 TO A , LINEARITY FOR 4.000V OUT, REPEAT AS REQUIRED. 1013/14 TA15 Strain Gauge Bridge Signal Conditioner 5V , quad operational amplifier which directly upgrades designs in the industry standard 14-pin DIP LM324 Linear Technology
Original

rosemount 118mf

Abstract: CD4066 Sample-and-Hold Circuits Battery-Powered Precision Instrumentation Strain Gauge Signal Conditioners , The LT ®1006 is the first precision single supply operational amplifier. Its design has been , range includes ground to accommodate low ground-referenced inputs from strain gauges or thermocouples , example, a 1mV input signal will cause the amplifier to set up in its linear region in the gain 100 configuration shown below, but is not enough to make the amplifier function properly in the voltage follower
Linear Technology
Original
CD4066 CD4066 PIN configuration diagram catalyst 2736 catalyst research corp 2736 catalyst research corp CD4066 PIN configuration

how to use STRAIN GAUGE with lm358

Abstract: LM324 and Three Op Amp Instrumentation Amplifiers Active Filters Battery-Powered Systems Strain Gauge and , s 380µV Max in S8 Package s 0.8nA Max Offset Current s 480µA Max Supply Current per Amplifier s , Range Difference Amplifier (AV = 1) 30 10M 25 ­ INPUT + 2 10M 1M ­ 8 1/2 , Rate Gain-Bandwidth Product Supply Current per Amplifier Channel Separation Minimum Supply Voltage , Amplifier LT1413ACN8 TYP MAX q q q q q q q q 88 100 300 200 4.0 3.3 q 85 97
Linear Technology
Original
LT1413 LT1078 LT1211 LT1213 LT1215 TA17- 04
Showing first 20 results.