500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
CS53L30-CNZR Cirrus Logic ADC, Delta-Sigma, 24-Bit, 4 Func, PBGA30 visit Digikey
CS5371A-ISZR Cirrus Logic 24-Bit Geophysical, Single/Dual-Channel Delta-Sigma Modulators visit Digikey
CS5372A-ISZR Cirrus Logic 24-Bit Geophysical, Single/Dual-Channel Delta-Sigma Modulators visit Digikey
CS53L30-CWZR Cirrus Logic ADC, Delta-Sigma, 24-Bit, 4 Func, PBGA30 visit Digikey
CS53L30-CNZ Cirrus Logic ADC, Delta-Sigma, 24-Bit, 4 Func, PQCC32 visit Digikey
CS5373A-ISZR Cirrus Logic Low-power, High-performance Delta-Sigma Modulator with Test DAC visit Digikey

star delta wiring diagram motor start y

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: restarting equipment. MAIN CHARACTERISTICS Max. Motor Power @40° C Star (Y) IAC53a @40° C Delta (D , TYPICAL WIRINGS BENEFIT FOR MOTOR STARTING DIRECT ON LINE (DOL) STARTING Input STAR (Y) DELTA , the Motor @400VAC Star Wiring (Y) Max Power of the Motor @230VAC Star Wiring (Y) Max Power of the Motor @400VAC Delta Wiring (D) Max Power of the Motor @230VAC Delta Wiring (D) Nom. Operating , NEW Series EMC48S50-02 Three-Phase Induction Motor Softstarter 200­480 Vac, 7.5kW (Y), 13kW (D Teledyne Relays
Original
wiring diagram STAR DELTA motor starter wiring diagram dol motor starter MOELLER Z00 10 3 phase 75kW motor soft circuit diagram wiring diagram DOL starter PLC star delta starter diagram IAC53
Abstract: Concerned Terminals Max Power of the Motor @400VAC Star Wiring (Y) Max Power of the Motor @230VAC Star Wiring (Y) Max Power of the Motor @400VAC Delta Wiring (D) Max Power of the Motor @230VAC Delta , restarting equipment. MAIN CHARACTERISTICS M x. Motor Power @40 ° C a Star (Y) IAC53a @40 ° C , Input STAR (Y) DELTA (D) Speed â'¢ Mechanical part stress - Noise - Maintenance costs â , NEW Series EMC48S50-03 Three-Phase Induction Motor Softstarter 200â'"480 Vac, 11kW (Y), 19kW (D Teledyne Relays
Original
Abstract: Concerned Terminals Max Power of the Motor @400VAC Star Wiring (Y) Max Power of the Motor @230VAC Star Wiring (Y) Max Power of the Motor @400VAC Delta Wiring (D) Max Power of the Motor @230VAC Delta , restarting equipment. MAIN CHARACTERISTICS M x. Motor Power @40 ° C a Star (Y) IAC53a @40 ° C , Input STAR (Y) DELTA (D) Speed â'¢ Mechanical part stress - Noise - Maintenance costs â , NEW Series EMC48S50-04 Three-Phase Induction Motor Softstarter 200â'"480 Vac, 15kW (Y), 26kW (D Teledyne Relays
Original
Abstract: Concerned Terminals Max Power of the Motor @400VAC Star Wiring (Y) Max Power of the Motor @230VAC Star Wiring (Y) Max Power of the Motor @400VAC Delta Wiring (D) Max Power of the Motor @230VAC Delta , of restarting equipment. MAIN CHARACTERISTICS M x. Motor Power @40 ° C a Star (Y) IAC53a , ) STARTING Input STAR (Y) DELTA (D) Speed â'¢ Mechanical part stress - Noise - Maintenance , NEW Series EMC48S50-01 Three-Phase Induction Motor Softstarter 200â'"480 Vac, 2.2kW (Y), 3.8kW (D Teledyne Relays
Original
DIRECT TORQUE CONTROL
Abstract: Concerned Terminals Max Power of the Motor @400VAC Star Wiring (Y) Max Power of the Motor @230VAC Star Wiring (Y) Max Power of the Motor @400VAC Delta Wiring (D) Max Power of the Motor @230VAC Delta , restarting equipment. MAIN CHARACTERISTICS M x. Motor Power @40 ° C a Star (Y) IAC53a @40 ° C , Input STAR (Y) DELTA (D) Speed â'¢ Mechanical part stress - Noise - Maintenance costs â , NEW Series EMC48S50-02 Three-Phase Induction Motor Softstarter 200â'"480 Vac, 7.5kW (Y), 13kW (D Teledyne Relays
Original
Abstract: restarting equipment. MAIN CHARACTERISTICS Max. Motor Power @40° C Star (Y) IAC53a @40° C Delta (D , TYPICAL WIRINGS BENEFIT FOR MOTOR STARTING DIRECT ON LINE (DOL) STARTING Input STAR (Y) DELTA , the Motor @400VAC Star Wiring (Y) Max Power of the Motor @230VAC Star Wiring (Y) Max Power of the Motor @400VAC Delta Wiring (D) Max Power of the Motor @230VAC Delta Wiring (D) Nom. Operating , NEW Series EMC48S50-01 Three-Phase Induction Motor Softstarter 200­480 Vac, 2.2kW (Y), 3.8kW (D Teledyne Relays
Original
MOELLER Z00 6 wiring diagram dol starter star delta starter wiring diagram motor wiring diagram Magnetic contactor testing soft starter star wiring diagram motor start y
Abstract: restarting equipment. MAIN CHARACTERISTICS Max. Motor Power @40° C Star (Y) IAC53a @40° C Delta (D , TYPICAL WIRINGS BENEFIT FOR MOTOR STARTING DIRECT ON LINE (DOL) STARTING Input STAR (Y) DELTA , @400VAC Star Wiring (Y) Max Power of the Motor @230VAC Star Wiring (Y) Max Power of the Motor @400VAC Delta Wiring (D) Max Power of the Motor @230VAC Delta Wiring (D) Nom. Operating Voltage Operating , NEW Series EMC48S50-04 Three-Phase Induction Motor Softstarter 200­480 Vac, 15kW (Y), 26kW (D Teledyne Relays
Original
U1 V1 and W1 is delta connections wiring diagram star delta starter star delta plc star delta wiring diagram motor start wiring diagram motor start y induction motor soft starter
Abstract: restarting equipment. MAIN CHARACTERISTICS Max. Motor Power @40° C Star (Y) IAC53a @40° C Delta (D , TYPICAL WIRINGS BENEFIT FOR MOTOR STARTING DIRECT ON LINE (DOL) STARTING Input STAR (Y) DELTA , the Motor @400VAC Star Wiring (Y) Max Power of the Motor @230VAC Star Wiring (Y) Max Power of the Motor @400VAC Delta Wiring (D) Max Power of the Motor @230VAC Delta Wiring (D) Nom. Operating , NEW Series EMC48S50-03 Three-Phase Induction Motor Softstarter 200­480 Vac, 11kW (Y), 19kW (D Teledyne Relays
Original
inside delta connection 3 volt DC motor 3 phase motor soft starter diagram three phase diagram dol motor starter soft starter wiring soft start motor 3 phase thyristor
Abstract: f 100ms tm CHARACTERISTICS Concerned Terminals Max Power Of The Motor @400VAC Star Wiring (Y) Max Power Of The Motor @230VAC Star Wiring (Y) Max Power Of The Motor @400VAC Delta Wiring (D) Max Power Of The Motor @230VAC Delta Wiring (D) Nom. Operating Voltage Operating Voltage Range Max , 200 - 480VAC ->15kW (Y) ->26kW (D) MAIN CHARACTERISTICS Max. Motor Power @40°C Star (Y , inside the delta wiring allows this device to drive 1.73 times more current than a standard on line Celduc Relais
Original
SMCW6150 15KW motor MOTOR CONTROL SWITCHES MOELLER star delta starter current 1.5KW motor te mini project using microcontroller magnetic Contactor 24VDC S/MOT/SMCW6150/A/22/07/99 1W240020
Abstract: production. Induction Motor Softstarter 200 - 480VAC ->2.2kW (Y) ->3.8kW (D) MAIN CHARACTERISTICS Max. Motor Power @40°C Star (Y) Delta (D) Max. 400VAC 230VAC 400VAC 230VAC 2.2kW 1.3kW , Power Of The Motor @400VAC Star Wiring (Y) Max Power Of The Motor @230VAC Star Wiring (Y) Max Power Of The Motor @400VAC Delta Wiring (D) Max Power Of The Motor @230VAC Delta Wiring (D) Nom , , its ability to be installed inside the delta wiring allows this device to drive 1.73 times more Celduc Relais
Original
SMCW6020 2.2KW induction motor wiring diagram motor start delta star delta wiring diagram wiring start dol ipbmi controls for 22kw motor S/MOT/SMCW6020/B/05/07/99 1W240040
Abstract: f 100ms tm CHARACTERISTICS Concerned Terminals Max Power Of The Motor @400VAC Star Wiring (Y) Max Power Of The Motor @230VAC Star Wiring (Y) Max Power Of The Motor @400VAC Delta Wiring (D) Max Power Of The Motor @230VAC Delta Wiring (D) Nom. Operating Voltage Operating Voltage Range Max , 200 - 480VAC ->7.5kW (Y) ->13kW (D) MAIN CHARACTERISTICS Max. Motor Power @40°C Star (Y , inside the delta wiring allows this device to drive 1.73 times more current than a standard on line Celduc Relais
Original
SMCW6080 7.5KW motor resistance wiring diagram for three phase starter thyristor contactor 75kw dc motor DOL wiring diagram motor S/MOT/SMCW6080/C/22/07/99 1W240050
Abstract: f 100ms tm CHARACTERISTICS Concerned Terminals Max Power Of The Motor @400VAC Star Wiring (Y) Max Power Of The Motor @230VAC Star Wiring (Y) Max Power Of The Motor @400VAC Delta Wiring (D) Max Power Of The Motor @230VAC Delta Wiring (D) Nom. Operating Voltage Operating Voltage Range Max , 200 - 480VAC ->2.2kW (Y) ->3.8kW (D) MAIN CHARACTERISTICS Max. Motor Power @40°C Star (Y , inside the delta wiring allows this device to drive 1.73 times more current than a standard on line Celduc Relais
Original
IEC947-4-2 24v coil dol project on dol starter wiring 2.2KW motor 3x200v marking code 3l2
Abstract: production. Induction Motor Softstarter 200 - 480VAC ->15kW (Y) ->26kW (D) MAIN CHARACTERISTICS Max. Motor Power @40°C Star (Y) Delta (D) Max. 400VAC 230VAC 400VAC 230VAC 15kW 8.6kW , Power Of The Motor @400VAC Star Wiring (Y) Max Power Of The Motor @230VAC Star Wiring (Y) Max Power Of The Motor @400VAC Delta Wiring (D) Max Power Of The Motor @230VAC Delta Wiring (D) Nom , , its ability to be installed inside the delta wiring allows this device to drive 1.73 times more Celduc Relais
Original
star delta diagram motor soft start motor control diagram shaded pole induction motor 15KW Motor Controller Star Delta Control circuit 8.6kW
Abstract: f 100ms tm CHARACTERISTICS Concerned Terminals Max Power Of The Motor @400VAC Star Wiring (Y , , 3L2, 4T2, 5L3, 6T3 Pn Max Power Of The Motor @230VAC Star Wiring (Y) Pn Max Power Of The Motor @400VAC Delta Wiring (D) Pn Max Power Of The Motor @230VAC Delta Wiring (D) Nom , Ext. Bypass to Mains Status Input Star (Y) Delta (D) Phase Frequency Outputs Max. EN60947 , 65Hz 480VAC 24VDC AC/DC BENEFIT FOR MOTOR STARTING DIRECT ON LINE (DOL) STARTING Î Î STAR (Y Celduc Relais
Original
SMCW6151 three phase induction motor magnetic Contactor 24VDC diagram Z002 IAC53b 3x200Vac dc motor control 24vdc 30A S/MOT/SMCW6151/A/23/07/99 1W240030
Abstract: f 100ms tm CHARACTERISTICS Concerned Terminals Max Power Of The Motor @400VAC Star Wiring (Y) Max Power Of The Motor @230VAC Star Wiring (Y) Max Power Of The Motor @400VAC Delta Wiring (D) Max Power Of The Motor @230VAC Delta Wiring (D) Nom. Operating Voltage Operating Voltage Range Max , 200 - 480VAC ->11kW (Y) ->19kW (D) MAIN CHARACTERISTICS Max. Motor Power @40°C Star (Y , inside the delta wiring allows this device to drive 1.73 times more current than a standard on line Celduc Relais
Original
SMCW6110 3 phase motor 4kw soft starter diagram General Electric Solid State 4KW motor 11KW 3 phase electric motor star delta starter connections S/MOT/SMCW6110/B/22/07/99 1W240060
Abstract: Max. Motor Power @40°C Star (Y) Delta (D) Max. 400VAC 230VAC 400VAC 230VAC 7.5kW 4.3kW , Power Of The Motor @400VAC Star Wiring (Y) Max Power Of The Motor @230VAC Star Wiring (Y) Max Power Of The Motor @400VAC Delta Wiring (D) Max Power Of The Motor @230VAC Delta Wiring (D) Nom , MOTOR STARTING DIRECT ON LINE (DOL) STARTING Î Î STAR (Y) In/Out/Case Isolation Operating , , its ability to be installed inside the delta wiring allows this device to drive 1.73 times more Celduc Relais
Original
Z00-16 dol starter SMCV starter for induction motor crane p h omega s 25
Abstract: production. Induction Motor Softstarter 200 - 480VAC ->11kW (Y) ->19kW (D) MAIN CHARACTERISTICS Max. Motor Power @40°C Star (Y) Delta (D) Max. 400VAC 230VAC 400VAC 230VAC 11kW 6.4kW , Power Of The Motor @400VAC Star Wiring (Y) Max Power Of The Motor @230VAC Star Wiring (Y) Max Power Of The Motor @400VAC Delta Wiring (D) Max Power Of The Motor @230VAC Delta Wiring (D) Nom , , its ability to be installed inside the delta wiring allows this device to drive 1.73 times more Celduc Relais
Original
4KW induction motor star delta connection wiring diagram 60v 50a dc motor controller circuit star delta wiring diagram motor DOL starter wiring diagram motor 4KW motor resistance
Abstract: f 100ms tm CHARACTERISTICS Concerned Terminals Max Power Of The Motor @400VAC Star Wiring (Y , , 3L2, 4T2, 5L3, 6T3 Pn Max Power Of The Motor @230VAC Star Wiring (Y) Pn Max Power Of The Motor @400VAC Delta Wiring (D) Pn Max Power Of The Motor @230VAC Delta Wiring (D) Nom , Ext. Bypass to Mains Status Input Star (Y) Delta (D) Phase Frequency Outputs Max. EN60947 , 65Hz 480VAC 24VDC AC/DC BENEFIT FOR MOTOR STARTING DIRECT ON LINE (DOL) STARTING Î Î STAR (Y Celduc Relais
Original
86kW Limit Switch en60947
Abstract: MEM Enclosed Switchgear and Motor Control · Fuse-switch-disconnectors & switch disconnectors , . Electrical Hydraulics 2 Enclosed switchgear and motor control product guide Contents 1 Product , Enclosed motor, heating and lighting control 45 5 Technical data 51 Indices 84 5 3 , Retail Pulp and paper Telecommunications Product overview 1 From the very start Eaton's MEM , . 12 1.2 Enclosed motor, heating and lighting control EATON
Original
star delta FORWARD REVERSE STARTER BS88-6 gec switchgear 100AXTN2 BS5419 100KXTNC2F PG01900001U
Abstract: type of wiring diagram or assembly. Time/Cost Savings. Connecting link No cable preparation , Star Delta starters. Select in the tables the contactor, thermal overload relay and accessory codes , torque in order to reach sufficient high speed when the motor is connected in star. Star-Delta , (delta) Transient current is generated when switching from star to delta connection. 5 , resistive torque of the driven load must remain, irrespective of speed, less than the «star» motor torque ABB Automation
Original
ABB A26-30-10 star delta timer starter diagram magnetic Contactor abb a9-30-10 wiring diagram ABB motor starter VE 5-2 ABB A9-30-10 1SBC141158C0201 1SB500060F0000 R2000 R2001 1SBC101001C0201 F-69685
Showing first 20 results.