500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
ADC11DS105CISQ/NOPB Texas Instruments Dual 11-Bit, 105 MSPS A/D Converter with Serial LVDS Outputs 60-WQFN visit Texas Instruments
TVP5151IPBSRQ1 Texas Instruments IC COLOR SIGNAL DECODER, PQFP32, GREEN, PLASTIC, QFP-32, Color Signal Converter visit Texas Instruments
LM2907D14R Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDSO14 visit Texas Instruments
LM2917P Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDIP8 visit Texas Instruments
LM2907D14 Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDSO14 visit Texas Instruments
LM2917D8R Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDSO8 visit Texas Instruments

signal converter pt1000

Catalog Datasheet MFG & Type PDF Document Tags

PT1000 application note

Abstract: 24VAC to 24VDC converter Signal Converters & Isolators Temperature Converter PXT-10/11 DESCRIPTION WIRING DIAGRAM Temperature converter for converting a temperature to an analogue process signal. The temperature converter , converter Pt1000 PXT-11 Strapped at low range -50-100°C DC 4-20mA output 0-20mA output Z1+Z2 , (GE), UL94V0. Weight: 170 g. PXL-10 Input signal Pt100/Pt1000 probe (DIN43760/IEC751), 2 or 3 , INTRO. Signal Converters & Isolators Temperature Converter PXT-10/11 Export: Tel: +45 46 74
-
Original
PXT-10 PT1000 application note 24VAC to 24VDC converter signal converter pt1000 3 wire pt100 sensor wiring diagram signal converter pt100 PT100 application note 100/P 0-10VDC/0-20/4-20 24VDC 24VAC 115VAC 230VAC

PT100 T

Abstract: PT1000 application note Signal Converters & Isolators Temperature Converter PXT-10/11 DESCRIPTION T em perature converter for converting a tem perature to an analogue process signal. T he tem perature converter has an Pt100/Pt1000 input in tw o ranges -50-300°C and -50-100°C. A ty p ic a l application is w here tem , Signal Converters & Isolators Temperature Converter PXT-10/11 TECHNICAL DATA Input signal Pt100 , diagram . WIRING DIAGRAM Pt100/Pt1000, 2 w ire Pt100/Pt1000, 3 w ire Y1 Y 2 Y 3 Strapped at low
-
OCR Scan
PT100 T ERM 547 IEC-751 XT-10 IEC68-2-3 IEC68-2-6 IEC68-2-27 EN50022 VDE0609-1

PT1000 temperature sensor

Abstract: DATASHEET PT1000 CONVERTERS AND INTERFACES K-LINE K109PT1000 Temperature converters K-LINE PT1000 Converter INPUT: PT1000 at 2,3,4 wires with zero and span configurable by dip-switch , 0.1% TECHNICAL DATA K109PT1000 ­ PT1000 Converter K109PT ­ PT100 converter ORDER CODES K109PT1000 PT1000 converter Accessories K-BUS Expandable power supply connector K-SUPPLY , ) Accuracy (20,5 K / temp + 0.05) % (Measurement range) DIP Switch -Inputs signal setup -Output
Seneca
Original
EN50081-2 EN50082-2 EN61010-1 PT1000 temperature sensor DATASHEET PT1000 DIN EN 60751 PT100 temperature sensor data sheet A/D converter pt100 measurement EN60742 60751/A2 ITS90

Pt 1000 IEC 751

Abstract: signal converter pt1000 NC14004 000816 Universal signal converter for temperature signals (PT10, PT100, PT1000) (3-way isolated), linearized C.A.I.S. UNI - RTD Analog signal converters C.A.I.S. series 40 000 width , Offset U: Supply voltage, LED green Marker A B C Temperature signal converter for PT10, PT100 and PT1000 signals (acc. to IEC 751 and JIS C 1604*) Configurable output signals in case of interrupts (LOW , supply 3-way isolation Short-circuit proof signal outputs Supply voltages: 24.48 V DC or 110.240 V
-
Original
Pt 1000 IEC 751 PT1000 output 0-5v CAIS UNI rtd PT10 PT1000 0-5v Pt 100 IEC 751 240VAC/100 300VDC

rtd PT10

Abstract: PT1000 RTD NC14004 011024 Universal signal converter for temperature signals (PT10, PT100, PT1000) (3-way isolated), linearized C.A.I.S. UNI - RTD Analog signal converters C.A.I.S. series 40 000 width , Offset U: Supply voltage, LED green Marker A B C Temperature signal converter for PT10, PT100 and PT1000 signals (acc. to IEC 751 and JIS C 1604*) Configurable output signals in case of interrupts (LOW , supply 3-way isolation Short-circuit proof signal outputs Supply voltages: 24.48 V DC or 110.240 V
-
Original
PT1000 RTD PT10 rtd pt100 jis wiring instruction for pt1000 PT-100 RTD RTD PT-100 UL1604

pt 1000 temperature sensor

Abstract: PT1000 temperature sensor output signal Load Relay output Temperature Sensor Pt1000 DN DN DN DN DN 15 65 15 15 65 , ( , distance version ( , /D-converter; long distance max. 500 m cable length; with Pt1000 8200 pH-sensor with A/D converter for long , combination pHelectrode, screwed into the sensor housing with screw-in threads PG 13.5. The measured signal
-
Original
pt 1000 temperature sensor soil ph sensor 3201-F1 PT-1000 temperature sensor ph transmitter PVDF measuring circuit 802-GB/

Entrelec uni

Abstract: signal converter pt1000 - Multi-Function Universal signal converter for temperature signals (PT10, PT100, PT1000) (3 , signal converter for PT10, PT100 and PT1000 signals (acc. to IEC 751 and JIS C 1604*) Configurable , Features & outline drawing Specifications & curves Dip switch configuration Analog signal converters , , PT1000 (IEC 751 and JIS C 1604)* Max. temperature adjustable: Temperature ranges adjustable from 20 °C , circuits D-F|A-C Output signal adjustable ±5 % 120 dB Current Voltage 0.20 mA / 4.20 mA
Entrelec
Original
Entrelec uni Entrelec Entrelec uni universal converter PT100 WIRING standard PT100 IEC 751 accuracy PT-1000 RTD 3 wire

pt1000 sensor interface WITH ADC

Abstract: PT1000 thermistor ASSEMBLY PT-104 Thermistor Converter and Data Logger Type Sensor Range Temperature PT100, PT1000 ­200 to , temperature converter for use with PT100 and PT1000 type sensors. It can be used to measure temperature , -bit resolution, the ADC-20 and ADC-24 USB data loggers are able to detect small signal changes. Features such as , , These Loggers Are Flexible Enough to Be Used with a Wide Range of Sensors and Signal Types Fast , Records Up to 4 Platinum Resistance Thermometers Works with PT100 and PT1000 Sensors Supports 2-, 3- and
-
Original
MI007 TA131 pt1000 sensor interface WITH ADC PT1000 thermistor USB Ethernet Adapter pt1000 temperature thermocouple passive sensor pt100 interface WITH ADC TA041 TA132 TA133 PS3206A/3206B
Abstract: , 0.200 mV, PT100, PT1000, Ni1000 DIN, LG-Ni1000, resistance 0.2000 Ω, etc. 12-bit A/D converter , ±3 Pressure % RH (±5 % at 40.60 % RH) 123 Duct IP65 Detectors 131 40 Output signal , Temperature sensors - PT100/PT1000 0.0015 1.5 mbar Damper actuators with spring return 100 , Valves and valve actuators 100 * 4.20 mA output signal only at DC supply voltage (two-wire). , 0.22482 Description Output signal x 0.00508 = m/s x 196.85 Humidity transmitter 0.10 V DC x REGIN
Original
S-428 PRODCAT2013 HDT3200 HRT250 HDT3200-420 HTDT3200

pt1000 temperature sensor schematic

Abstract: 130009 power transistor are required. A low-noise, 24-bit, delta-sigma analog-to-digital converter (ADC) with the ability to , reference to the MX7705. Application-specific ICs are also available for thermocouple signal conditioning , example, the MAX31855 is cold-junction-compensated thermocouple-to-digital converter that digitizes the signal from a K, J, N, T, or E Type thermocouple. The MAX31855 measures thermocouple temperatures with , MAX11200 24-bit delta-sigma ADC and allows thermocouple temperature measurements. Here, R1 - PT1000 (PTS
Maxim Integrated Products
Original
pt1000 temperature sensor schematic 130009 power transistor PT1000 CONVERSION TABLE Omega k type thermocouple range accuracy of K type thermocouple fluke pt1000 type thermocouple sensor ITS-90 KTSS-116 MAX11200EVKIT MAX6002 MAX6627 MAX11206

PT1000 temperature sensor

Abstract: PT1000 RTD Analog standard signal converter CC-U/STD Ordering details CC-U/STD universal signal converter , Configurable output signal response on input signal interruption (low fail safe / high fail safe) Adjustment and operating elements on the front-side Short-circuit proof signal outputs Plug-in connecting terminals for inputs, outputs and supply Very fast signal transmission enables use in control systems , 019 F0003 Coarse Type *) Detection of input signal interruptions: If the input signal circuit
-
Original
2CDC110004C0202 PT100 IEC 751 4.20 mA 0-5 converter 0-5 v to 4-20 ma converter CC-U/STD rtd pt100 code example

sensors voltage battery

Abstract: '¢ #7; ombined Temperature/Humidity Sensors C #7; #7; t100/Pt1000 RTD, Thermistor â'¢P Temperature , (Internal Memory Size) U Up to 32 Hz Sampling Rate U High Accuracy U 20 Bit A/D Converter U #7; hock Proof , probe for OMYL-M90E) â'¢ #7; xternal temperature (Pt100/Pt1000 RTD, U thermistor) E â'¢ #7; xternal , Temperature Input #7;ensor: Pt100 or Pt1000 RTD, U thermistor (2000 Ω S @ 25°C) Range: -70 to 250 , © shunt Accuracy: 0.1% of range Signal Input: OMYL-CI cable Pulse Input #7; ignal Input
Omega Engineering
Original
sensors voltage battery OMYL-M90 MYL-M90 MYL-M90E OMYL-M90-4M OMYL-M90E-4M OMYL-WH20

pt100/RTD PT100

Abstract: MIL-T-24388 refer to the configured measuring span of the analog output signal Effect on DA converter ME = voltage , resistance > 10 M Internal reference point Pt1000, IEC 60751 Cl. B (no additional jumpers necessary , signal Configurable 4 . 20 mA (standard) Configurable 20 . 4 mA (dynamic range: 3.8 . 20.5 mA in , output current 23.6 mA Configurable error current signal Override 22 mA (20.0 . 23.6 mA , Speisespannung Two-wire technology; power lines = signal lines Supply voltage Non ignition-proof application
ABB Automation
Original
TTH200 pt100/RTD PT100 MIL-T-24388 PT200 reference table PT50 temperature sensor PT200 RTD reference table PT200 rtd DS/TTH200-EN 3KXT231002R1001

PT1000 CONVERSION TABLE

Abstract: PT1000 table CONVERSION PT-104 Thermistor Converter User's Guide pt104.en-4 Copyright 2005-8 Pico Technology. All , Introduction 1.1 1 Overview The PT-104 is a four-channel, high-resolution temperature converter for use with PT100 and PT1000 type sensors. It can be used to measure temperature, resistance and voltage. In PT100/PT1000/resistance mode, the unit uses a fourwire circuit. In voltage mode, the input , connected to mains voltages, you risk damage to the converter or your computer and your computer chassis
Pico Technology
Original
PT1000 table CONVERSION PT100 st 199 115 BS1904 PT1000 table DELPHI Connectors labview picoscope

PT1000 thermocouple

Abstract: ADuM5401 isoPower® integrated, isolated dc-to-dc converter, 500 mW output power ADR441 precision 2.5 V , using the ADuM5401 (quad-channel isolator with integrated dc-todc converter), ADuM1401 (quad-channel isolator), or ADM3251E (fully isolated RS-232 transceiver). Input signal conditioning is performed by the , PT1000 RTD temperature sensor. Figure 8 shows how to connect this RTD to the PLC demo board. The , with the PLC demo system board. The RS-232 signal can be connected straight to the RS-232 port of the
Analog Devices
Original
PT1000 thermocouple UG-181 AD7793 AD8220 M5401 AD5422 C7027

resistance to Current Converter 0-20mA

Abstract: PT1000 RTD R TE YEA The new DUALCON Isolating Signal Converter can accept a wide range of inputs , either voltage or current. E Isolating Signal Converter 2 outputs DUALCON GUARAN Universal , of Current: 0-20mA. Voltage: 10VDC Dualcon/03/03 www.imopc.com Isolating Signal Converter 2 , inversion of the input signal, on either one or both of the outputs. The unit is supplied with two power , options Resistance Thermometers 2,3 or 4 wire PT100 or PT1000, linearised or non-linearised. Ranges
IMO
Original
resistance to Current Converter 0-20mA rtd pt100 4-20ma connections 4-20ma isolation Current to voltage Converter 4-20mA to 0-10v 90-264VAC 18-32VAC 16-36VDC 264VAC 32VAC 36VDC

0-10V 4.....20MA

Abstract: resistance to Current Converter 0-20mA R Universal input/output- user selectable TE YEA The new ISOCON Isolating Signal Converter can accept a wide range of inputs including 4-20mA, thermocouple, RTD and voltage signals. The units produce a high level DC output of either voltage or current. E Isolating Signal Converter , : 0-20mA. Voltage: 0-10VDC ISOCON/03/03 www.imopc.com Isolating Signal Converter ISOCON , adjustment of the unit quick and simple. Other features include optional inversion of input signal an
IMO
Original
0-10V 4.....20MA 0-10V to 0-20mA converter Isolated 4-20ma isolated 4 to 20ma analog transmitter circuit Voltage to Current Converter 4-20mA Voltage to Current Converter circuit 4-20mA 12-32VAC 12-36VDC 36VDC/32VAC

pt100 rtd spi

Abstract: ad8603 circuit schematic ADC with PGA Quad-Channel, 2.5 kV Isolators with Integrated DC-to-DC Converter Isolated 4 , Schematic: All Connections and Decoupling Not Shown) CIRCUIT DESCRIPTION signal generated is typically , +60 mV. It is important for the signal chain to maintain as high impedance and low leakage as , (Pt100 and Pt1000). One method used to accurately measure the resistance is to measure the voltage , current is typically only a few hundred microamps to prevent self heating. Analog-to-Digital Converter
Analog Devices
Original
pt100 rtd spi ad8603 circuit schematic CN-0287 AD7193 ADT7310 AD8603 ADR3440 ADG738

thermoresistance

Abstract: PT1000 ensures a degree of protection of IP 65. Model Measurement Power supply Setpoints Signal Output Engineering unit Option Measurements Power supply Signal output CFX: Std., input: Pt100 Ni100 200 TC: J, L, K, T, E CFP: Std., input: Pt1000 2000 TC: J, L, K, T, E A: Type Selection 24 , Specifications Accuracy RTD (@ 25°C ± 5°C, R.H. 60%) Pt100/Pt1000 Ni100 TC (@ 25°C ± 5°C, R.H. 60 , ppm/°C, thermocouple ± 200 ppm/°C 2 times/s, dual slope 16 bits A/D converter 7-segment LED, h
Carlo Gavazzi
Original
thermoresistance MDI40C Ni100 PT100 IEC B PT1000 RTD probe MDI40 MDI40CFX
Abstract: ABRIDGED DATA SHEET MAX35101 EVALUATION KIT AVAILABLE Time-to-Digital Converter with Analog Front-End General Description The MAX35101 is a time-to-digital converter with built-in amplifier and , , the MAX35101 supports up to four (4) 2-wire PT1000/500 platinum resistive temperature detectors (RTD , ●● Temperature Measurement â'¢ Up to Four (4) 2-Wire Sensors â'¢ PT1000 and PT500 RTD Support , DATA SHEET MAX35101 Time-to-Digital Converter with Analog Front-End Absolute Maximum Ratings Maxim Integrated Products
Original
PT1000/500 32KX1 32KX0 32KOUT MAX35101EHJ
Showing first 20 results.