500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
ULN2003LVDR Texas Instruments Low Power 3.3V & 5V Relay Driver 16-SOIC -40 to 85 visit Texas Instruments Buy
UC3702D Texas Instruments Quad PWM Relay Driver 16-SOIC 0 to 70 visit Texas Instruments
ULN2003V12PWR Texas Instruments Low Power 7 channel Relay Driver 16-TSSOP -40 to 125 visit Texas Instruments Buy
DS3680D Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 visit Texas Instruments Buy
UC3702N Texas Instruments Quad PWM Relay Driver 16-PDIP 0 to 70 visit Texas Instruments
DS3680DE4 Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 visit Texas Instruments

siemens dc relay

Catalog Datasheet MFG & Type PDF Document Tags

siemens 3UG3

Abstract: 3UG35 0.1 Minimum contact load at 17 V DC mA 5 Output relay with DIAZED fuse gL/gG operational , 31/3UG46 32 voltage monitoring relay is supplied with an auxiliary voltage of 24 V AC/DC or 24 to , Minimum contact load at 17 V DC mA 5 Output relay with DIAZED fuse gL/gG A 4 Electrical , current must always flow through M or the monitoring relay may be destroyed! Siemens LV 1 T · 2007 , superposed DC measuring voltage is used to perform the measurement. The monitoring relay is divided into
-
Original
3UG45 siemens 3UG3 3UG35 3UG4615 3ug3 SIEMENS RELAY 3UG46 3ug46 3UG46

siemens Logo manual

Abstract: siemens Logo 230RC user manual uninterrupted current â'¢ Rated switching capacity - AC-15 - DC-13 3 monostable relay outputs 2 monostable relay outputs A 6 A/24 V AC 2 A/24 V DC 10/10 Siemens IC 10 · 2014 6 A/120 V AC , current â'¢ Rated switching capacity - AC-15 - DC-13 © Siemens AG 2013 SIMOCODE 3UF Motor , For ungrounded AC networks - For ungrounded DC and AC networks Level monitoring - Level monitoring , interface converters Siemens IC 10 · 2014 IC 10 · 2014 Siemens 10 10 © Siemens AG 2013 Â
Siemens
Original
siemens Logo manual siemens Logo 230RC user manual siemens sirius siemens logo application examples Wiring Diagram Siemens Logo siemens relay 3RT191 3UF18 3RP15 3RS17 3RS1720-1ET00 3RS1720-2ET00

siemens V23026

Abstract: DIODE 1334 smd Miniature Relay P1 V23026 PCB relays ­ Pin or SMD ­ for DC operation, polarised, monostable , operating position. 4 Siemens AG Miniature Relay P1 SMD version Dimension drawing (in mm , against terminal 8, the relay adopts the operating position. Siemens AG 5 Miniature Relay P1 , ] Siemens AG 7 Miniature Relay P1 Coil versions Nominal voltage Unom V­ Operating voltage , : Relays with surge voltage resistance of 2.5 kV, 2/10 µs on request Siemens AG 9 Miniature Relay
Siemens
Original
siemens V23026 DIODE 1334 smd SMD DK QC siemens bistable relay smd diode 1334 siemens relay iec HS-180 E-28760 S-16493 TR-80040 N-0518 GR-15110

CPU 1214C

Abstract: CM 1241 RS232 /relay 85 . 264 V AC 24 V DC Siemens ST 70 N · 2010 4/5 © Siemens AG 2010 SIMATIC S7 , 1211C DC/DC/Relay 4/6 Siemens ST 70 N · 2010 © Siemens AG 2010 SIMATIC S7-1200 Central , 211-1HD30-0XB0 CPU 1211C DC/DC/Relay 4 Siemens ST 70 N · 2010 4/9 © Siemens AG 2010 SIMATIC S7 , /DC/DC 6ES7 211-1HD30-0XB0 CPU 1211C DC/DC/Relay 4 4/10 Siemens ST 70 N · 2010 © Siemens , 211-1HD30-0XB0 CPU 1211C DC/DC/Relay 4 Siemens ST 70 N · 2010 4/11 © Siemens AG 2010 SIMATIC S7
Siemens
Original
KTP400 KTP1000 KTP600 CPU 1214C CM 1241 RS232 232-4HA30-0XB0 s7-1200 examples 6ES7 232-4HB30-0XB0 214-1AE30-0XB0 1212C 1214C TP1500
Abstract: 40 V DC DPDT Relay - 19 . 230 V AC, 19 . 40 V DC (stocked version)1) 4 â  Dimensional , : Terminal 1: + Terminal 2: 19 . 50 V DC, +10 %, 2 W SITRANS LVS100 connections Siemens , © Siemens AG 2013 Level Measurement Point level measurement â'" Vibrating switches SITRANS , causes the relay to change state after a one second delay. When the fork is free from material pressure, full vibration resumes and the relay reverts to its normal condition. â'¢ Key Applications: dry bulk Siemens
Original
7ML1998-5FT63 7ML1830-1NS 7ML1830-1NT 7ML1830-1NU

LH1526

Abstract: LH1525ACD overvoltage protection is provided. The relay can be configured for ac/dc or dc-only operation. The LH1525 , October 1998 LH1547 1 Form A dc High-Voltage Solid State Relay FEATURES LH1547 Load Voltage , DESCRIPTION The LH1547 is a SPST normally open unidirectional relay that can switch ac and dc signals. The , handle loads up to 120 mA. The relay can switch both ac and dc loads and is ideal for audio frequency or dc applications. Typical ON-resistance at 25 mA is 25 W. The LH1191 relay consists of a GaAIAs LED
Siemens
Original
LH1527 LH1537 LH1526 LH1525ACD Solid State Relay No Nc dip S1S28 LH1525AAB LH1085AT1/AAB1

3th4293

Abstract: siemens 3th42 -14 and DC-13. 5/6 Siemens IC 10 · 2014 2 3 4 5 6 7 10 e -DC-13 24 V a (A , A 10 3RH22, 3RH29: Ie = 6 A for AC-15/AC-14 and DC-13. Siemens IC 10 · 2014 5/9  , © Siemens AG 2013 Switching Devices â'" Contactors and Contactor Assemblies â'" Contactor , Relay couplers Relay couplers with plug-in design Semiconductor couplers SIRIUS 3RS18 coupling relays with industrial enclosure Relay couplers Coupling relays with LZS/LZX plug-in relays Plug-in relay
Siemens
Original
3RH21 3th4293 siemens 3th42 Ntc 500-11 3TH2 40E 3TH42 3TH43 3RH24 3TG10 3RH11 PTMT0730 3TX7004-8BA00

siemens relay

Abstract: ANSI overcurrent relay inverse normal curves SIPROTEC 4 - 7SD610 Differential Protection Relay for Two Line Ends Description 2 Siemens SIP 5.4 â , navigation Fig. 1 Front view of the 7SD610 relay (1/3 x 19â' version) 4 Siemens SIP 5.4 â' 2001 , ) Siemens SIP 5.4 â' 2001 5 SIPROTEC 4 - 7SD610 Differential Protection Relay for Two Line Ends , and inrush restraint is provided by the relay. Siemens SIP 5.4 â' 2001 11 SIPROTEC 4 - , SIPROTEC 4 - 7SD610 Universal Differential Protection Relay for Two Line Ends Protection
Siemens
Original
ANSI overcurrent relay inverse normal curves siemens master trip relay E50001-K4405-A141-A1-7600 6101/D6159

V23082-A1005-A401

Abstract: V23082 Miniature Power Relay Mini L Product Information Miniature Power Relay Mini L V23082 PCB relay for DC voltage, neutral, monostable Features q High switching capacity of 10 A, small , Siemens AG VDE UL VDE applied for 3 Miniature Power Relay Mini L Dimensional drawing , arc with a burning time > 0.4 ms (transit time). Siemens AG 5 Miniature Power Relay Mini L , Siemens AG Miniature Power Relay Mini L Coil versions (Sensitive coil) V­ Operate voltage at
Siemens
Original
L-1017 A23001-G11-P038-X-7600 V23082-A1005-A401 relay mini schrack ra 900 siemens modules GR 60 48 V 120 A siemens 230 98 ECR0976-I A101/A P-2700 I-20127 NL-2500

QXA2602

Abstract: QXA2603 '™s potential free AC/DC 1.30 V relay changeover contact (QXA2601/QXA2602), or â'¢ that operate at , relay changeover contact (QXA2603/ QXA 2604). 2/8 Siemens Building Technologies Condensation , 3 SIEMENS QXA2601/QXA2603 QXA2602/QXA2604 Condensation Monitor â'¢ â'¢ â'¢ â'¢ â , AC / DC 24 V or AC 230 V Potential free changeover contact AC/ DC 1â'¦30 V or AC 230 V Simple and , QXA2604 AC /DC 24 V S55770-T325 Integrated/remote Switching output AC 30 V, 1 A / Integrated
Siemens
Original
QXA2602 QXA2603 SY-HS-230 HUMIDITY SENSOR CB1N3302 QXA2601 S55770-T326 S55770-T327

MOSFET SSR

Abstract: LH1504 RON and dynamic RON. The static R ON describes the dc output resistance of the relay at a single , discussed in detail in numerous other Siemens solid state relay publications. Figure 4. Typical DAA , Using the LH1504 Solid State Relay Appnote 63 Introduction Output Offset Voltage Most of the relays in Siemens portfolio of solid state relays (SSRs) utilize a pair of source-coupled MOSFETs , for relays used in dc and ac applications. However, there is another circuit topology which will
Siemens
Original
LH1500 MOSFET SSR audio isolation transformer Appnote63 SIEMENS MOSFET application signal path designer

siemens modules GR 60 48 V 120 A

Abstract: V23057-B0006-A101 SIEMENS Card Relay E (KRE) V23057 PCB relay for DC voltage, neutral, monostable Features q Used , applications Elevator controls Siemens AG3 5146 Card Relay E (KRE) Dimensional drawing (in mm , /creepage dist. S 8 mm 4 Siemens AG Card Relay E (KRE) Dimensional drawing (in mm) Upright , Siemens AG Card Relay E (KRE) Coil data Nominal voltages From 6 V­ to 60 V­ Special voltages , temperature tamb Siemens AG7 Card Relay E (KRE) General data Operate time at Unom and 20 °C, typ
Siemens
Original
V23057-B0006-A101 SIEMENS UpRight SP 37 siemens GR 60 48 V 120 A V23057-B0006-A101 siemens relay v23057 siemens relays V23057 ECR0975-B A23001-G11-P035-X-7600
Abstract: OUTPUT SM 1222, 16 DO, RELAY 2A Supply voltage permissible range, lower limit (DC) 5V permissible range, upper limit (DC) 30 V Input current from backplane bus 5 V DC, max. 135 mA Digital inputs from load voltage L+ (without load), max. 11 mA/relay coil Power losses Power loss , Rated input voltage of relay coil L+ (DC) 24 V Number of operating cycles, max. mechanically 10 , externally subject to modifications © Copyright Siemens AG 2012 6ES7222-1HH30-0XB0 Page 2 Siemens
Original

siemens bistable relay

Abstract: siemens V23026 SIEMENS Miniature Relays P1 Product Information Miniature Relay P1 V23026 PCB relays , adopts th e operating position. 4 Siemens AG Miniature Relay P1 SMD version D im ension d , operating position. Siemens AG 5 Miniature Relay P1 Contact data Number of contacts and type , ms 6 Siemens AG Miniature Relay P1 Coil data Nominal voltages Nominal power consumption , /amb [°C] Siemens AG 7 Miniature Relay P1 Coil versions Nominal voltage Miom VOperating
-
OCR Scan
ECR0670-K siemens HS-180 V23026-B1102-B201

siemens relay v23101

Abstract: siemens V23101 w11_1we Seite 3 Montag, Juli 29, 1996 1:08 PM Small Relay W11 V23101 1 changeover contact PCB relay for DC operation, non-polarized, monostable Features q General-application relay q , circuit assembling ­ Plastic case ­ Siemens AG ­ Immersion cleanable 3 w11_1we Seite 4 Montag, Juli 29, 1996 1:08 PM Small Relay W11 1 changeover contact Dimension drawing (in , asymmetrical Version: 6 pins Version: 5 Pins Version: 5 Pins 4 Siemens AG w11_1we Seite 5
Siemens Electromechanical Components
Original
V23101-D0104-B201 siemens relay v23101 siemens V23101 siemens relay pins siemens relay v23101 a VDE 0435 time relay relay vde 0435 ECR0987-Y

siemens dc relay

Abstract: siemens relay -1200, DIGITAL OUTPUT SM 1222, 8 DO, RELAY 2A Supply voltages Rated value permissible range, lower limit (DC) 5V permissible range, upper limit (DC) 30 V Short-circuit protection 0.0000000000000000E+00 Current consumption from backplane bus DC 5 V, max. 120 mA Digital inputs from load voltage L+ (without load), max. 11 mA / relay coil used Current consumption/power loss Power loss , . 150 m Relay outputs Number of relay outputs 8 Rated input voltage of relay L+ (DC) 24 V
Siemens
Original
6ES7222-1HF30-0XB0 siemens dc relay 6es72221hf300xb0 S71200 SIMATIC S7-1200 of relay

6ES7222-1HH30-0XB0

Abstract: siemens dc relay -1200, DIGITAL OUTPUT SM 1222, 16 DO, RELAY 2A Supply voltages Rated value permissible range, lower limit (DC) 5V permissible range, upper limit (DC) 30 V Short-circuit protection 0.0000000000000000E+00 Current consumption from backplane bus DC 5 V, max. 135 mA Digital inputs from load voltage L+ (without load), max. 11 mA / relay coil used Current consumption/power loss Power loss , . 150 m Relay outputs Number of relay outputs 16 Rated input voltage of relay L+ (DC) 24 V
Siemens
Original
Abstract: I/O SM 1223, 8DI / 8DO, 8DI DC 24 V, SINK/SOURCE, 8DO, RELAY 2A Supply voltage 24 V DC Yes permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V Input current from backplane bus 5 V DC, max. 145 mA Digital inputs from load voltage L+ (without load), max. 4 mA/input 11 mA/relay Output voltage Power supply to the transmitters present Yes , Relay outputs Number of relay outputs 8 Rated input voltage of relay coil L+ (DC) 24 V Siemens
Original
6ES7223-1PH30-0XB0

QXA2000

Abstract: automatic plant watering circuit 's potentialfree AC / DC 1.48 V relay changeover contact, or · that, in connection with the AQX2000 extension , 's potentialfree AC / DC 12.250 V relay changeover contact Mode of operation With its sensing element, the , condensation monitor and delivers the condensation signal via its potentialfree AC / DC 12.250 V relay , . approx. 5 % r. h. Output Q11, Q12, Q14 Relay output Current range at AC / DC 24 V Starting , 12.250 V 0.01.6 A min. AC/DC 12 V, 10 mA max. AC/DC 250 V, 6 A 4/6 Siemens Building Technologies
Siemens
Original
QXA2000 automatic plant watering circuit automatic plant watering block diagram Relief Valve DATA SHEET CE1N1542en chilled water system 1542P02 1542P01 CE1N1542 89/336/EEC 73/23/EEC

siemens v23100

Abstract: SIEMENS V23103 bbE T> m 8231,312 Q002200 4MB MSIEC Solid State Relay Type B1 SIEMENS/ POTTER/BRUnFIELD Type B1 With , bbE T> â  fl23b312 00DEBD1 301 »SIEC Solid state Relay Type B3 SIEMENS/ POTTER/BRUMFIELD Type B3 , bbE D â  aaabaiE ddoei^s ess «siec SIEMENS/ POTTER/BRUHFIELD Solid State Relays V23100-S , A2 and A8): UL File E 69913 8.11 bbE » â  653b3ia DDQ2nb 111 MSIEC Solid State Relays SIEMENS , . operate time ms 10 10 0.1 Control circuit Control voltage V DC 3 . 6 3 . 30 3 . 20 Pick-up
-
OCR Scan
V23103-S siemens v23100 SIEMENS V23103 V23100 V23100 siemens S2034 siemens heat sink 60229-6M V23103- S2232- S2032- S2332-