500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
J2014001L402 GE Critical Power GP100, 3&934;-480, RS485 communications, controller slot, LAN, RJ45 terminations, configured for slot 3 visit GE Critical Power
J2014001L422N GE Critical Power GP100, 3&934;-480, RS485 communications, controller slot, RJ45 terminations, includes a L401 and a L402 shelves in the same enclosure. Hardware included visit GE Critical Power
J2014004 GE Critical Power Compact Power Line Shelves, RS485 shelf for the CP3500 rectifier visit GE Critical Power
DS3695ATM Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC -40 to 85 visit Texas Instruments
DS3695ATMX/NOPB Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC -40 to 85 visit Texas Instruments Buy
DS3695ATM/NOPB Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC -40 to 85 visit Texas Instruments

rs485 termination

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: LTC2872 RS232/RS485 Dual Multiprotocol Transceiver with Integrated Termination DESCRIPTION , ©) Termination Resistors Half-/Full-Duplex RS485 Switching Logic Loopback Mode High ESD: ±16kV on Line I/O , SW 470nF Mixed Mode with RS485 Termination 3V TO 5.5V 22µH 2.2µF 2.2µF VCC , 1 0 INPUT LOW 130 RESISTANCE (Ω) OUTPUT VOLTAGE (V) 1.6 RS485 Termination , 11): RS485 Termination Enable for Transceiver #1. A logic high enables a 120â"¦ resistor between Linear Technology
Original
RS232/RS485 RS232 RS422 RS232/RS485/RS422 LTC2870/LTC2871 LTC1334

IEC60654-1

Abstract: rs485 termination /3 Internal GND, via 100 Ohm resistor 3 RS485 termination on 3* Address set 4 X2/4 Input RS485+ 4 RS485 termination on 4* Address set 8 X2/5 Input RS485- 5 , Interface · RS-485 multi-trop, 9600 Baud · Maximum 32 nodes per multi-trop network · Up to 500 cable , TERMINATION S2 S1 Dimension: 90 mm 111 mm 48 mm 43.5 mm m 0m 8 96 mm Publikation
-
Original
IEC60654-1 rs485 termination grx2 IEC60654 LED25 32VDC 94-V0 RS485- LED25-TD001A-EN-D

rs485 repeater

Abstract: rs485 termination ) Termination Resistors Half-/Full-Duplex RS485 Switching Logic Loopback Mode High ESD: ±16kV on Line I/O 1.7V , LTC2872 RS232/RS485 Dual Multiprotocol Transceiver with Integrated Termination Description The LTC®2872 , DY1 VCC 470nF 3V TO 5.5V 22µH 2.2µF 2.2µF VL CAP SW LTC2872 Y1 VCC RS485 OFF ON TERMINATION DY1 RS232 Mode 1.7V TO VCC 470nF 3V TO 5.5V 22µH 2.2µF Mixed Mode with RS485 Termination 1.7V TO VCC , (mA) 10 2872 G13 RS485 Termination Resistance vs Temperature VCM = ­7V VCM = 2V VCM = 12V
Linear Technology
Original
rs485 repeater 2872 B231 TE485-1 LTC1387 LTC2801/LTC2802/ LTC2803/LTC2804 LTC2854/LTC2855 LTC2859/LTC2861 LTM2881

power wizard 1.0 wiring diagram

Abstract: power wizard 2.1 wiring diagram a multi-drop RS485 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive , System, to meet RS485 Termination Requirements. 2 Input/Output 3 Input DATA+ Pin 1 of , multi-drop RS485 System, to meet RS485 Termination Requirements. 4 N/A N/A 5 GND = signal , Introduction 1.1 Functional Description The USB-COM485-PLUS2 is a USB to a dual interface RS485 level , , simple way to connect devices with an RS485 interface to USB. USB-COM485-PLUS2 is a USB to a dual-port
FTDI
Original
power wizard 1.0 wiring diagram power wizard 2.1 wiring diagram FT2232 FT2232H FT232BM FT232R
Abstract: VeriSens® (RS485) termination resistor integrated depth 110 mm fixation standard mounting , Â"Â"Gateway with integrated EtherNet/IPâ"¢ switch to connect VeriSens® via RS485 interface Â"Â"Allows , for RS485 Pin 4, 6: RS485+ Pin 5, 7: RS485- 3 Pin assignment on the devices (max. 4) Pin 9 (red): RS485+ Pin 12 (red/blue): RS485- 4 Branch lines (AWG26 recommended, thicker cross Baumer
Original
MXG02 Q3/2015

USB-COM485-PLUS4

Abstract: USB-COM485-PLUS4 Datasheet multi-drop RS485 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive DATA , USBCOM485-PLUS4 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , RS485 Termination Requirements. 4 N/A N/A 5 GND = signal ground GND 6 N/A N/A , Introduction 1.1 Functional Description The USB-COM485-PLUS4 is a USB to a quad interface RS485 level , , simple way to connect devices with an RS485 interface to USB. USB-COM485-PLUS4 is a USB to a quad-port
FTDI
Original
USB-COM485-PLUS4 Datasheet RS485-level RS485-SYSTEM ft4232 power wizard 1.1 wiring diagram ft4232h rs485
Abstract: a multi-drop RS485 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive , device in a multi-drop RS485 System, to meet RS485 Termination Requirements. 2 Input/Output , first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements. 4 N/A , Introduction 1.1 Functional Description The USB-COM485-PLUS4 is a USB to a quad interface RS485 level , , simple way to connect devices with an RS485 interface to USB. USB-COM485-PLUS4 is a USB to a quad-port FTDI
Original

USB-COM485-PLUS1 Datasheet

Abstract: USB-COM485-PLUS1 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive DATA+ Data , USBCOM485-PLUS1 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , USB-COM485PLUS1 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , multi-drop RS485 System, to meet RS485 Termination Requirements. 4 N/A N/A 5 Ground 6 N , . This model, USB-COM485-Plus1, provides a simple method of adapting legacy serial devices with RS485
FTDI
Original
USB-COM485-PLUS1 USB-COM485-PLUS1 Datasheet 120R tv cable signal receiving trouble ft232r connection to device USB-COM485-P

power wizard 2.1 wiring diagram

Abstract: cable modem eccn System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive DATA+ Data , USBCOM485-PLUS1 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , USB-COM485PLUS1 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , multi-drop RS485 System, to meet RS485 Termination Requirements. 4 N/A N/A 5 Ground 6 N , . This model, USB-COM485-Plus1, provides a simple method of adapting legacy serial devices with RS485
FTDI
Original
cable modem eccn free circuit diagram of USB modem DE-9P EIA-485

power wizard 2.1 wiring diagram

Abstract: 120R System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive DATA+ Data , USBCOM485-PLUS1 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , USB-COM485PLUS1 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , multi-drop RS485 System, to meet RS485 Termination Requirements. 4 N/A N/A 5 Ground 6 N , . This model, USB-COM485-Plus1, provides a simple method of adapting legacy serial devices with RS485
FTDI
Original

power wizard 1.0 wiring diagram

Abstract: USB-COM485-PLUS4 a multi-drop RS485 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive , RS485 Termination Requirements. 4 N/A N/A 5 GND = signal ground GND 6 N/A N/A , Introduction 1.1 Functional Description The USB-COM485-PLUS4 is a USB to a quad interface RS485 level , , simple way to connect devices with an RS485 interface to USB. USB-COM485-PLUS4 is a USB to a quad-port RS485 adapter. The integrated electronics of the USB-COM485-PLUS4 utilise the FTDI FT2232H and includes
FTDI
Original
ft2232 mini module FT4232H

ftdi10

Abstract: ft2232 mini module a multi-drop RS485 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive , RS485 Termination Requirements. 4 N/A N/A 5 GND = signal ground GND 6 N/A N/A , Introduction 1.1 Functional Description The USB-COM485-PLUS2 is a USB to a dual interface RS485 level , , simple way to connect devices with an RS485 interface to USB. USB-COM485-PLUS2 is a USB to a dual-port RS485 adapter. The integrated electronics of the USB-COM485-PLUS2 utilise the FTDI FT2232H and includes
FTDI
Original
ftdi10 modem circuit echo

USB-COM485-PLUS2 Datasheet

Abstract: USB-COM485-PLUS2 a multi-drop RS485 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive , RS485 Termination Requirements. 4 N/A N/A 5 GND = signal ground GND 6 N/A N/A , Introduction 1.1 Functional Description The USB-COM485-PLUS2 is a USB to a dual interface RS485 level , , simple way to connect devices with an RS485 interface to USB. USB-COM485-PLUS2 is a USB to a dual-port RS485 adapter. The integrated electronics of the USB-COM485-PLUS2 utilise the FTDI FT2232H and includes
FTDI
Original
USB-COM485-PLUS2 Datasheet RS485 to db9 pinout usb male connector pcb mounted
Abstract: multi-drop RS485 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive DATA , USBCOM485-PLUS1 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , USB-COM485PLUS1 is the first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements , multi-drop RS485 System, to meet RS485 Termination Requirements. 4 N/A N/A 5 Ground 6 N , . This model, USB-COM485-Plus1, provides a simple method of adapting legacy serial devices with RS485 FTDI
Original

RX232

Abstract: RT485 LTC2870/LTC2871 RS232/RS485 Multiprotocol Transceivers with Integrated Termination DESCRIPTION , )Termination Resistors Half-/Full-Duplex RS485 Switching High ESD: ±26kV (LTC2870), ±16kV (LTC2871) Logic , Termination Selection 1.7V TO VCC VL RS232 RS485 3V TO 5.5V LTC2870 Simultaneous Protocols and RS485 Termination Switching 1.7V TO VCC VL VCC 485/232 RS485 TERMINATION DY 3V TO 5.5V , VOLTAGE (V) THRESHOLD VOLTAGE (V) 1.6 2 RS485 Termination Resistance vs Temperature VL =
Linear Technology
Original
RX232 RT485 RT-232 DX232 TOKO RS485 rs485 to rs232 2870/LTC2871 LTC2854 RS485/RS422 2500VRMS LTM2882

RT485

Abstract: RX232 RS232/RS485 Multiprotocol Transceivers with Integrated Termination DESCRIPTION The LTC®2870/LTC2871 are , RS232 Automatic Selection of Integrated RS485 (120) and RS232 (5k)Termination Resistors Half , Automatic Termination Selection 1.7V TO VCC VL RS232 RS485 485/232 DY Y Z A DZ RA A B RB RO 120 B DIN1 , RS485 TERMINATION OFF ON 120 DI Z DI, DY Y Z Simultaneous Protocols and RS485 Termination Switching , 0 0 2 4 6 8 OUTPUT CURRENT (mA) 10 28701 G14 RS485 Termination Resistance vs Temperature VCM =
Linear Technology
Original
5vRS232 LTC2870FE DX485 LTC2870CUFD RS232RS485RS422 LTC2804
Abstract: a multi-drop RS485 System, to meet RS485 Termination Requirements. 2 DATA+ = Transmit/Receive , last device in a multi-drop RS485 System, to meet RS485 Termination Requirements. 2 Input/Output , first or last device in a multi-drop RS485 System, to meet RS485 Termination Requirements. 4 N/A , Introduction 1.1 Functional Description The USB-COM485-PLUS2 is a USB to a dual interface RS485 level , , simple way to connect devices with an RS485 interface to USB. USB-COM485-PLUS2 is a USB to a dual-port FTDI
Original

resistor 4k7

Abstract: B1100-GP B1100-PP Series B1100-PP B1100-PP B1100-PP-HC B1100-PP-HC-XC S4: CAN/RS485 Termination Position , B1100-VF B1100-VF B1100-VF-HC B1100-VF-XC S4: CAN/RS485 Termination Position Indexing PE ±10V , ±10V Force or Velocity Control S4: CAN/RS485 Termination Setpoint Streaming (CAN) PE Analog , Edition 15 subject to change S4 Switch 1: RS232 (switch "off" / RS485 "on") Switch 2: Termination RS485 on/off Switch 3: Termination CAN on/off Switch 4: Bootstrap www.LinMot.com Select serial
LinMot
Original
B1100 B1100-PP-XC B1100-GP B1100-GP-HC B1100-GP-XC resistor 4k7 5-phase drive STEPPER MOTOR INTERPOLATOR SIN COS x8 encoder X13/14
Abstract: LTC2870/LTC2871 RS232/RS485 Multiprotocol Transceivers with Integrated Termination DESCRIPTION , ©)Termination Resistors Half-/Full-Duplex RS485 Switching High ESD: ±26kV (LTC2870), ±16kV (LTC2871) Logic , Termination Selection 1.7V TO VCC VL RS232 RS485 3V TO 5.5V LTC2870 Simultaneous Protocols and RS485 Termination Switching 1.7V TO VCC VL VCC 485/232 RS485 TERMINATION DY 3V TO 5.5V , RESISTANCE (Ω) OUTPUT VOLTAGE (V) THRESHOLD VOLTAGE (V) 1.6 2 RS485 Termination Resistance Linear Technology
Original

SP494

Abstract: ,n= 2 .4 V V *= 0.4V I - -1 8 m A lL - 60mA, VC M - 0V; full load R l - 100 ohms (RS422); termination load RL - 54 ohms (RS485); termination load for complementary output state R l = 27 ohms or 50 ohms Rt =* 54 ohms (RS485) for complementary output state RL a 54 ohm s or 100 ohm s lO H = -5 5 m A lO H = , RS485/RS422 Transceivers RS485 and RS422 +5V Only Power Supply Required Receiver Fail-Safe Mode G , differential line driver/receiver meeting both RS485 and RS422 specifications. The SP494/495 features three
-
OCR Scan
SP494 SP495 DS36950/ DS36954 RS422/485