500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
MDM-51PH006R ITT Interconnect Solutions MICRO 51 M 36 RBW rever FLOAT visit Digikey Buy

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : 110 V MODEL 17 REVERSE Supplier : TE Connectivity Manufacturer : Heilind Electronics Stock : - Best Price : - Price Each : -
Part : 220 V MODEL 17 REVERSE Supplier : TE Connectivity Manufacturer : Heilind Electronics Stock : - Best Price : - Price Each : -
Part : 110 V MODEL 17 REVERSE Supplier : TE Connectivity Manufacturer : Interstate Connecting Components Stock : - Best Price : - Price Each : -
Part : 220 V MODEL 17 REVERSE Supplier : TE Connectivity Manufacturer : Interstate Connecting Components Stock : - Best Price : - Price Each : -
Shipping cost not included. Currency conversions are estimated. 

reversal

Catalog Datasheet MFG & Type PDF Document Tags

Lambda diode

Abstract: 40KV DIODE diode for the first measurements and calculate the percent reversal. Use this as a guide as what to , circuit in figure 4 below shows the equivalent supply output circuit with a voltage reversal. HV Supply , voltage reversals. The RMS. rating can be determined using the following steps. Peak current during , greater than Irms due to load voltage reversal. Forward Voltage Drop - as small as possible. 93008517 , VOLTAGE REVERSAL PROTECTION APP Note 517 Simple Resistive Protection When a high voltage is
Lambda EMI
Original
Lambda diode 40KV DIODE Lambda EMI 40KV CABLE diode rectifiers protection PFN DIODE

brake mosfet switch BLDC Motor

Abstract: 3 phase bldc motor driver mosfet -Quad : Current Rises to Sum of Applied & BEMF Volts at Reversal 2-Quad : Modified Controlled Deceleration , -Quadrant Reversal waits for Low (or Zero) Freewheel Current 2-Quadrant Reversal waits for Low (or Zero) Freewheel Current 2-Quadrant Single Chip Hitachi BLDC Speed Reversal 2-Quadrant Speed (Voltage) Control 2 , Reversal BLDC Motor Drive Power Stage Design - Part 4 BLDC Motor Drive Power Stage Design - Part 4 BLDC , Control - Part 2 BLDC Motor - Safe Direction Reversal Introduction to BLDC Motor Torque Control - Part 2
Hitachi
Original
brake mosfet switch BLDC Motor 3 phase bldc motor driver mosfet 12v DC SERVO MOTOR CONTROL circuit DC SERVO MOTOR CONTROL circuit brake mosfet hall switch BLDC Motor hall effect for bldc
Abstract: A 90° B Inp A : Counter input Counting on an edge Inp B : Reversal of direction rS0 : Display , falling edge Inp B : Reversal of  â , Inp B : Counter input Counting on a rising edge and on a falling edge, reversal of direction rS0 , Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP rS0 A 90° B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP Crouzet
Original
CTR48 VDC/30

10v zener

Abstract: Calling Detecting Line Polarity Reversal Associated with BT Calling Line Identification Protocol The following circuit can be used to detect line polarity reversal per the British Telecommunications (BT) Standard CDSTM for Calling Line Identification Service. Line Polarity Reversal indicates to the Customer , decode the calling line information. Referring to the timing diagram in Figure 1, the line reversal , LINE SIGNALING LINE REVERSAL 100mS < 4.8 sec 88-110mS TONE ALERT 45mS < 4.8 sec
CP Clare
Original
10v zener Calling Calling Line Identification line following circuit TB-LDA100-R1

D65PAR208

Abstract: D65PAR480 , Reversal and Undervoltage Phase Loss, Reversal and Undervoltage Product Selection Table 3-133 , rated socket when using on system voltages greater than 300V. D65PAR Series Phase Loss, Reversal and , protection against phase loss, phase reversal and undervoltage in a compact plug-in design. These devices are , Data and Specifications Table 3-135. Technical Data - D65PAR Series, Phase Loss, Reversal and Undervoltage Description Phase Loss Phase Reversal Undervoltage Output Contacts Life Response Times: Operate
EATON
Original
D65PAR208 D65PAR240 D65PAR480 D65CHDS CA08102002K07A automatic phase correction EATON D65PAR120 D65PAR400
Abstract: The PCP Series Phase Monitor Relays provide protection against phase reversal in a compact plug-in , . u PCP Series protects against phase reversal only u PLP Series protects against phase loss & phase reversal u LED indicates both normal and fault conditions u Compact plug-in case utilizing , protection against phase loss & phase reversal in a compact plug-in design. The relay is energized and the , to Neutral required. PCP SERIES PROTECTS AGAINST Phase Reversal u NOMINAL VOLTAGEF (50/60 Macromatic
Original
70169-D PLP120 PLP208 PLP240 PLP400 PLP480

LDA100SM

Abstract: 0.47uF 200V Application Note: AN-118 Detecting Line Polarity Reversal Associated with BT Calling Line , following circuit can be used to detect line polarity reversal per the British Telecommunications (BT) Standard CDSTM for Calling Line Service. Line Polarity Reversal indicates to the Customer Premise Equipment , line information. Referring to the timing diagram in Figure 1, the line reversal event indicates that , < 12V (10V zener + Vf diode + Vf LED) while also providing the required 15V sensitivity to the reversal
IXYS
Original
LDA100SM 0.47uF 200V AN-118-D
Abstract: sustain reversals. Some applications can disregard this; a good example being a simple speed control for a , what happens to the circuit in Figure 1 during reversal-assuming the amplifier current limit is set at , the back EMF, providing the values shown during the reversal. The dissipation during this event is , : stall current and reversal current. Reversing a motor is about the most stressful application to which , 1A + 45V RW = 3.2ohms I = 1A EMF 41.8 ­ RW 3.2ohms REVERSAL LOAD LINE OUTPUT CURRENT FROM +V S OR Apex Microtechnology
Original
546-APEX PA12A AN24U

AMD SLIC

Abstract: AMD thermal design guide , and Test) functions with features including current limiting, on-hook transmission, polarity reversal , , polarity reversal, and for some applications on-chip ringing. These options provide functionality that , , Filter (Tip Reversal (dB) bit, E0 type) Ring Test pin Open) 52, 63 1 3 32 PLCC 32 PLCC, 500 -6.02 52, 63 , Polarity Drivers Bal. Enable (pins, Filter (Tip Reversal (dB) bit, E0 type) pin Open) Ring Test 52, 63 40 , GND Relay Packages Key Start Polarity Drivers (pins, type) Filter (Tip Reversal pin Open) Ring Test
Advanced Micro Devices
Original
AMD SLIC AMD thermal design guide 79M531 79M535 79M574 79M576A 79C202/203

Am79489JC

Abstract: relay snubber ring and test relay drivers and relay snubber circuits Polarity reversal (full transmission) Loop and , -4 -5 -6 = = = = = = 52 dB Longitudinal Balance, Polarity Reversal 60 dB Longitudinal Balance, Polarity Reversal 52 dB Longitudinal Balance, No Polarity Reversal 60 dB Longitudinal Balance, No Polarity Reversal 52 dB Longitudinal Balance, No Polarity Reversal, Metering 52 dB Longitudinal Balance, Polarity Reversal, Metering DEVICE NUMBER/DESCRIPTION Am79489 Subscriber Line Interface Circuit Valid
-
OCR Scan
Am79489JC relay snubber

PA12A

Abstract: PA05 application . It's important to establish from the outset if it will be necessary to sustain reversals. Some , reversal-assuming the amplifier current limit is set at 3 amps. Motor operating current is a function of load. So , the reversal. The dissipation during this event is 246W-clearly outside the PA12 SOA. Motor , rating conditions to be considered when designing a reliable application: stall current and reversal , I = 1A ­ RW 3.2ohms STEADY STATE REVERSAL +50 +50 =1 25° tat ys ad C
-
Original
PA05 application APEX LINE AMP PA12 PA09 PA05 PA04

pabx systems

Abstract: HC55143 HC55121 SLIC, Low Power, 30mA Loop Current, Polarity Reversal, Longitudinal Balance 53dB 53 , Power, 45mA Loop Current, Polarity Reversal, Gnd Start, Gnd Key, Line Volt Measurement, with Long Balance 63dB 63 x HC55142 SLIC, Low Power, 45mA Loop Current, Polarity Reversal, Gnd Start , Power, 45mA Loop Current, Polarity Reversal, Gnd Start, Gnd Key, Line Volt Measurement, with Long , , Polarity Reversal SLIC, Low Power, 45mA Loop Current, Line Voltage Measurement, Pulse Metering
Intersil
Original
HC55120 HC55130 HC55140 pabx systems HC55143 HC5504B 1-888-INTERSIL HC55185 75/85/100V
Abstract: one motor against phase loss, unbalance, phase reversal, and rapid cycling. Other features are a , Reversal and Short Cycling Meets NEC Code for Motor Overloads 1.25 . 80 A in 3 Adjustable Ranges Fast , minimum FLA setting & current unbalance ≤ 40% Overload Range Phase Reversal Phase Loss/Unbalance , 7.5 8.0 8.5 9.0 9.5 10 Motor Protection Overload Type Note: Phase reversal, phase loss are not sensed until the motor is energized & conditions of Phase Reversal, Phase Loss/Unbalance SSAC
Original
P1015 1-800-377-SSAC
Abstract: =3, 4, and 5. Synchronizing period, Polarity reversal possible signal (1) (TIM0) Horizontal , ) Internal analog video signal output (GPIO pin) signal Analog I/F Polarity reversal possible , . Position, polarity reversal possible Continued on next page No.A1186-4/17 LC749880T Continued , polarity reversal possible 1 FLM When MODE=0, 1, and 2, gate start pulse signal output Pulse width, position, polarity reversal possible. Hi-Z when FLM2 is used 1 OE When MODE=0, 1, and 2 ON Semiconductor
Original
ENA1186 51408HKIM 20080319-S00007 A1186-1/17 A1186-17/17

208-480V

Abstract: EN60947-1 PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMD , cover a variety of applications with one unit u Protects against phase loss, phase reversal , reversal, phase unbalance, undervoltage and overvoltage. The PMDU is a universal voltage product that , 16 1/09 PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over , Reversal: Unit trips if rotation (sequence) of the three phases is anything other than A-B-C
Macromatic
Original
EN60947-1 EN60947-5-1 208-480V phase sequence protection PMD120 three phase sequence 120/240V E109466

208-480V

Abstract: EN60947-1 PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMD , cover a variety of applications with one unit u Protects against phase loss, phase reversal , microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage , Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMD Series Surface-Mount Application , A, B or C. Load (burden): Less than 3VA Phase Reversal: Unit trips if rotation (sequence) of
Macromatic
Original
PMD600

Triac 380v

Abstract: imbalance and phase reversal. It consists in the DSP-1L or DSP-1LM detector, available from Controlab inc , ONTROLAB INC. PHASE LOSS, REVERSAL AND IMBALANCE DETECTOR DSP-1L OR DSP-1LM Phase Loss or , . DSP-1L PHASE FAILURE PHASE REVERSAL PHASE ASYMME TRIC DETECTOR R ONTROLAB INC. Made in , power utility network or your own electrical installations break down (phase loss, phase reversal or , available from Controlab inc. Let us explain . Phase Reversal It sometimes happens that your power
CONTROLAB
Original
Triac 380v

TAIYO 85

Abstract: JWK105BJ Capacitance of 1F with 0.3mm Thickness An LW Reversal Decoupling Capacitor Thickness Reduced by 40% Compared , significant new additions to its expanding LW Reversal Decoupling Capacitor (LWDC®) lineup. Consistent with the Company's existing portfolio of low ESL LW Reversal Decoupling Capacitors that position external , decoupling capacitors in proximity to ICs to ensure stable operations. Taiyo Yuden's LW Reversal Decoupling , layers. In employing these technologies in the newly released LW Reversal Decoupling Capacitors, the
Taiyo Yuden
Original
JWK105BJ AWK105C6 TAIYO 85 size 0204 capacitor 105MP

208-480V

Abstract: phase sequence indicator PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMP , variety of applications with one unit u Protects against phase loss, phase reversal, phase , reversal, phase unbalance, undervoltage and overvoltage. The PMPU is a universal voltage product that , RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMP Series Plug-in , Phase A, B or C. Load (Burden): Less than 3VA Phase Reversal: Unit trips if rotation (sequence
Macromatic
Original
phase sequence indicator 120v relay 11 pin diagram 600V-rated unbalance load, power loss AC/30V

Bell-202

Abstract: Bell202 Line ID Receiver with: â'¢ 'Zero-Power' Ring or Line Polarity Reversal Detector â'¢ V23/Bell202 FSK , evolving services. The device includes a 'zero-power' ring or line polarity reversal detector, a dual-tone , .6.12 1.5.8 Ring or Line Polarity Reversal 1.5.9 , oscillator inverter. 3 RD l/P (S) Input to the Ring or Line Polarity Reversal Detector. 4 RT Bl Open-drain output and Schmitt trigger input forming part of the Ring or Line Polarity Reversal detector. An external
-
OCR Scan
FX602 SIN227 Bell-202 Bell202 1N4004 f5k 6.8 V23/B D/602/3 2130H 2750H
Showing first 20 results.