NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: PTFA3315 PTFA3315) · Level sensor with REED switch : Closed : float end sensor lined up Open : float and sensor out of line ( Reverse function byusing the sensor upside down ) · Typical applications for water : level detection of oils/petrol. For water and food it is better to use Polypropylene Sensor (see , P/SPE/PTFA3115/B/15/06/2004 P/SPE/PTFA3115/B/15/06/2004 page 1 /2 F/GB Capteur de niveau horizontal Horizontal level sensor PTFA3115 PTFA3115 Nylon / 230VAC 230VAC 0,5A/10VA · Capteur de niveau à ampoule REED : 1 contact fermé ... | Original |
2 pages, |
PTFA3315 PTFA3215 capteur rubber detection PTFA3115 gravity sensor capteur de tension P/SPE/PTFA3115/B/15/06/2004 P/SPE/PTFA3115/B/15/06/2004 abstract |
| Abstract: Level sensor with REED switch : Closed : float end sensor lined up Open : float and sensor out of line ( Reverse function byusing the sensor upside down ) · Typical applications for water : level detection of oils/petrol. For water and food it is better to use Polypropylene Sensor (see PTFA3215 PTFA3215 & PTFA3315 PTFA3315 , P/SPE/PTFA3015/C/16/06/2004 P/SPE/PTFA3015/C/16/06/2004 page 1 /2 F/GB Capteur de niveau horizontal Horizontal level sensor PTFA3015 PTFA3015 Nylon / 200VDC 200VDC 0,5A/10VA · Capteur de niveau à ampoule REED : 1 contact fermé ... | Original |
2 pages, |
PTFA3315 PTFA3215 PTFA3015 gravity sensor capteur de tension Capteur P/SPE/PTFA3015/C/16/06/2004 P/SPE/PTFA3015/C/16/06/2004 abstract |
| Abstract: combined seven-day digital timer and photo-electric control device. The remote sensor -which can be mounted up to 100 metres away from the controller - detects ambient light level. The load is controlled by pre-setting on the din-rail device the lux level at which switching should occur, as well as the , light is below a pre-determined level. Technical specification: Dimensions 85 x 52.5 x 60 (1 module) Weight 250g AC switching capacity: - resistive load 16A 250v AC - inductive load ... | Original |
1 pages, |
550C datasheet abstract |
| Abstract: boissons, lave linge ,. , alimentaire. · Float on the sensor normally open contact liquid level is up / normally closed contact liquid level is down · Float under the sensor normally closed contact liquid level is up / normally open contact liquid level is down ( Reverse function byusing the sensor , P/SPE/PTFA3215/B/16/06/2004 P/SPE/PTFA3215/B/16/06/2004 page 1 /2 F/GB Capteur de niveau horizontal Horizontal level sensor PTFA3215 PTFA3215 Polpropylene / / 200VDC 200VDC 0,5A/10VA · Partie flotteur sur le dessus contact ouvert ... | Original |
2 pages, |
PTFA3215 gravity sensor coffee vending machine circuit Capteur Sensors liquid float level sensor P/SPE/PTFA3215/B/16/06/2004 P/SPE/PTFA3215/B/16/06/2004 abstract |
| Abstract: Short-circuit protection Sensor input One level Two levels Operating frequency Input resistance Cable , /one level The relay operates when the sensor is immersed and releases when the sensor is no longer , The relay operates when the upper sensor (max. level) is immersed and releases when the lower sensor (min. level) is no longer immersed. When pins 7 and 8 are interconnected (dotted line), the , Diagrams Example 1 Example 2 and 3 1 sensor = 1 level Max. or min. control 2 sensors = 2 levels ... | Original |
2 pages, |
SPDT 5 pins Relay proximity sensors 5 pin relay voltage pins liquid level sensor capacitive capacitive sensor level datasheet abstract |
| Abstract: control device. The remote sensor which can be mounted up to 100 metres away from the controller detects ambient light level. The load is controlled by pre-setting on the din-rail device the lux level at which , 75g AC switching capacity: - resistive load - inductive load cos 0.6 8A 250v AC - , Ambient temperature Control unit -200C -200C to +500C Sensor -300C -300C to +700C Adjustment range 2 , Control unit IP20 Sensor Remote sensor IP65 Dimensional details ... | Original |
1 pages, |
500C datasheet abstract |
| Abstract: below the min. level sensor (Y3). The relay releases if the level reaches the max. level sensor (Y2). , Discharging The relay operates when the level reaches the max. level sensor (Y2), if the min. level sensor (Y3) is in contact with the liquid. The relay releases when the min. level sensor no longer is in , Level Sensors Amplifier, Conductive Type ELA (Charging/Discharging) · · · · · · · · · · Level control for conductive liquids Max./min. control of charging/discharging Adjustable sensitivity ... | Original |
2 pages, |
datasheet abstract |
| Abstract: scale from 10 to 100 k. When using only the max. level sensor, single level control is possible. , accuracy Sensor voltage Output Rated insulation voltage Contact ratings (AgCdO) Resistive loads AC , sensor. The relay releases if the level rises above the max. level sensor. Single level control is obtained by connecting the max. level sensor only. -20/+50% ±50% 1 k/°C 0.5%/V LED, green LED , liquids. The relay operates when the level rises above the max. level sensor. The relay releases when ... | Original |
2 pages, |
PE Relay conductive type level sensor datasheet abstract |
| Abstract: boissons, lave linge ,. vis M16 x2 M16x2 screws · Float on the sensor normally open contact liquid level is up / normally closed contact liquid level is down · Float under the sensor normally , byusing the sensor upside down :fig. 2) · Typical applications for water :liquid level detection for , P/SPE/PTFA3315/A/16/06/2004 P/SPE/PTFA3315/A/16/06/2004 page 1 /2 F/GB Capteur de niveau horizontal Horizontal level sensor PTFA3315 PTFA3315 Polypropylene 230VAC/0 230VAC/0,5A 50VA · Partie flotteur sur le dessus contact ouvert ... | Original |
2 pages, |
liquid float level sensor drinks vending machine circuit PTFA3315 P/SPE/PTFA3315/A/16/06/2004 P/SPE/PTFA3315/A/16/06/2004 abstract |
| Abstract: boissons, lave linge ,. · Level sensor with REED switch : Closed : float end sensor lined up Open : float and sensor out of line ( Inverse function by reversing th sensor ) · Typical applications for water : liquid level detection for drink vending or coffee machines, washing machines . Dimensions , P/STD/PTFA3015/B/07/01/2003 P/STD/PTFA3015/B/07/01/2003 page 1 /2 F/GB Capteur de niveau horizontal Horizontal level sensor PTFA3015 PTFA3015 · Capteur de niveau à ampoule REED : 1 contact fermé avec capteur et flotteur ... | Original |
2 pages, |
PTFA3015 capteur drinks vending machine circuit capteur de tension P/STD/PTFA3015/B/07/01/2003 P/STD/PTFA3015/B/07/01/2003 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is provided proportional to fluid level and single shot or repeating measurements may be made. All supervisory National P/N LM1042 LM1042 LM1042 LM1042 - Fluid Level Detector [Discontinued] LM1042 LM1042 LM1042 LM1042 Product Folder Fluid Level Detector [Discontinued] Generic P/N 1042 Kbytes Date View Online Download Receive via Email LM1042 LM1042 LM1042 LM1042 Fluid Level Detector 170 Kbytes www.datasheetarchive.com/files/national/pf/lm1042.html |
National | 17/02/2005 | 4.29 Kb | HTML | lm1042.html |
| The LM1042 LM1042 LM1042 LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is provided proportional to fluid level and single shot or repeating measurements may be made. All supervisory requirements to control the thermal-resistive probe, including short and open circuit probe National P/N LM1042 LM1042 LM1042 LM1042 - Fluid Level Detector Please enable Javascript in your browser. [Information as of 11-Sep-98] LM1042 LM1042 LM1042 LM1042 Fluid Level Detector Generic P/N 1042 Contents General www.datasheetarchive.com/files/national/htm/nsc03142-v4.htm |
National | 16/09/1998 | 6.89 Kb | HTM | nsc03142-v4.htm |
| LM1042 LM1042 LM1042 LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is provided proportional to fluid level and single shot or repeating measurements may be made. All supervisory requirements to control the thermal-resistive probe, including short and open circuit probe Please enable Javascript in your browser. National P/N LM1042 LM1042 LM1042 LM1042 - Fluid Level Detector [Life Fluid Level Detector [Life-time buy] Generic P/N 1042 Contents General Description www.datasheetarchive.com/files/national/htm/nsc05567.htm |
National | 18/12/1998 | 7.07 Kb | HTM | nsc05567.htm |
| Please enable Javascript in your browser. National P/N LM1042 LM1042 LM1042 LM1042 - Fluid Level Detector [Life [Information as of 12-Aug-99] LM1042 LM1042 LM1042 LM1042 Fluid Level Detector [Life-time buy] Generic P/N 1042 & Pricing General Description The LM1042 LM1042 LM1042 LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is provided proportional to fluid level and single shot or repeating measurements may be made. All supervisory requirements to control the thermal-resistive www.datasheetarchive.com/files/national/htm/nsc02397-v1.htm |
National | 13/08/1999 | 9.63 Kb | HTM | nsc02397-v1.htm |
| LM1042 LM1042 LM1042 LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is provided proportional to fluid level and single shot or repeating measurements may be made. All supervisory requirements to control the thermal-resistive probe, including short and open circuit probe National P/N LM1042 LM1042 LM1042 LM1042 - Fluid Level Detector [Information as of 1-Apr-98] LM1042 LM1042 LM1042 LM1042 Fluid Level Detector Generic P/N 1042 Contents General www.datasheetarchive.com/files/national/docs/wcd00005/wcd00593.htm |
National | 03/04/1998 | 6.04 Kb | HTM | wcd00593.htm |
| sensor signal conditioner that is capable of digitally correcting sensor outputs over a wide temperature range. The MAX1452 MAX1452 MAX1452 MAX1452 is a highly integrated analog-sensor signal processor optimized for use with resistive element sensors. The MAX1452 MAX1452 MAX1452 MAX1452 provides amplification, calibration, and temperature compensation New Product Release: Precision Smart Sensor Signal Conditioner Provides 16-Bit ) Precision Smart Sensor Signal Conditioner Provides 16-Bit Correction SUNNYVALE, CA-December 6 www.datasheetarchive.com/files/maxim/0006/view_008.htm |
Maxim | 04/04/2001 | 8.46 Kb | HTM | view_008.htm |
| . It can work with ratiometric systems. Examples are resistive sensors for temperature, pressure, etc. In this application, the signal of the external sensor floats in conjunction with the ADC. The SVCC switch is on and SVCC has nearly the same level. External systems are to the voltage level at SVCC. Signals that must be measured with absolute accuracy . The ADC conversion results are calculated with use of a reference level to the absolute www.datasheetarchive.com/files/texas-instruments/tools/faq/modules/adc8.htm |
Texas Instruments | 16/08/2000 | 2.86 Kb | HTM | adc8.htm |
| osc = 4.7nF for the external components. 3 Sensor Input Connection for liquid level sensing. During low liquid level indication of the sensor. The delay depends on the internal oscillator frequency 4620 4/9 The L4620 L4620 L4620 L4620 liquid level alarm is designed to operate with a variety of sensor types which change imped - ance depending on whether the sensor is above or below the level of a liquid. If the considerably. If, however, it is not necessary to decouple and filter the sensor a simple resistive network www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1764.htm |
STMicroelectronics | 20/10/2000 | 13.71 Kb | HTM | 1764.htm |
| liquid level is indicated by an attenuation between transmitted and received signal across a sensor tip = 4.7nF for the external components. 3 Sensor Input Connection for liquid level sensing. During the alarm delay to activate the output stage after a low liquid level indication of the sensor. The delay selected. The AC driving of the level sensor allows the use of a capacitive filter (C A , C B to decouple and filter the sensor a simple resistive network may be used, eliminating the www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1764-v3.htm |
STMicroelectronics | 25/05/2000 | 13.17 Kb | HTM | 1764-v3.htm |
| for sonobuoys, remote pressure sensors, temperature control, active voltage-resistive (VR) sensors power dissipation levels than existing CMOS operational amplifiers. In addition, the noise performance depicts the low level of voltage noise for this CMOS amplifier, which has only 200 uA (typical) of supply . This technology also makes possible input impedance levels that meet or exceed levels offered by top piezoelectric transducers. Because of the low-power dissipation levels, these devices work well in hand www.datasheetarchive.com/files/texas-instruments/data/html/slos130b.htm |
Texas Instruments | 31/05/1997 | 3.79 Kb | HTM | slos130b.htm |