500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : NCP1075PREGEVK Supplier : ON Semiconductor Manufacturer : Avnet Stock : - Best Price : $150.00 Price Each : $150.00
Shipping cost not included. Currency conversions are estimated. 

regenerative brake

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: 6 -2 6 -1 -1 Regenerative brake option . . . . 6 - 2 6 - 1 - 2 Cable connectors. . 6 , the power supply, servo motor, regenerative brake option and ground._ Display , filter Regenerative brake option Wires R efer To Section 6 - 2 - 1 Section 6 - 2 - 1 Section 6 - 2 - 4 , MC at occurrence of an alarm. Regenerative brake option (Optional) -0- 0C P Power supply M R - , . Regenerative brake option (Optional) rC "h Power supply M R -C D A : Single-phase 200VAC M R -C D A 1 -
OCR Scan
MR-C10A1 MR-C10A FR-BiF MR-C-T01 HC-PQ23 servo motor encoder 24VDC
Abstract: required to limit current harmonics on the AC line and to provide impedance between the regenerative brake , This program includes standard 1336 REGEN Line Regeneration Packages for use in regenerative brake , Ordering/Pricing Information Factory configured and assembled Regenerative Brake or DC Bus Supply , regeneration option for 1336 PLUS, 1336 PLUS II, 1336 IMPACTTM and 1336 FORCETM AC drives. In a regenerative brake configuration (bus supply configuration is also available, see page 4), the 1336 REGEN is used -
Original
1203-S03 22-HIM-H10 Allen-Bradley 1336f 1202-C10 Allen-Bradley 1336 dynamic brake bulletin 1336 Allen-Bradley ip20 1203-SG2 1203-SG4 9303-PL002 1336R
Abstract: cable Brake Regenerative with 20-bit 17-bit without Reactor cable resistor brake Incremental , regenerative resistor (external resistor is also enabled.) Dynamic brake Built-in Control mode , .114 Junction Cable for Brake , . 127 External regenerative resister. . 128 . Surge absorber for motor brake Panasonic
Original
service manual servo mbdht2510e MBDHT2510 CODE ERROR MDDHT5540E msm 8255 MBDHT2510 MANUAL MBDHT2510E ISO14001 ISO9001
Abstract: support software. regenerative capability. Command control modes Built-in dynamic brake Offers , ) Controller Encoder cable Regenerative resistor (option) Ground (Earth) Motor cable Brake cable , equipments to page A4-12 Brake cable Regenerative discharge register overheat detection I/O terminal , Optional parts Motor cable Note) 2 Motor cable (with brake) Note) 2 Brake cable Regenerative , Setup support with substantial monitoring function ● Discharges the regenerative energy with Panasonic
Original
DV0P197 MUMA012P31N MUMA012P32N MUMA012P34N MUMA012P41N MUMA012P42N MUMA012P44N
Abstract: support software. regenerative capability. Command control modes Built-in dynamic brake Offers , ) Controller Encoder cable Regenerative resistor (option) Ground (Earth) Motor cable Brake cable , -12 Brake cable Regenerative discharge register overheat detection I/O terminal Fan stop signal , (with brake) Note) 2 Brake cable Regenerative resistor Note) 2 DV0P4283 DV0P4284 Reactor , -117 Brake cable 50Ω , 25W DV0P4280 100Ω , 25W DV0P4281 25Ω , 50W DV0P4282 A4-125 Regenerative Panasonic
Original
panasonic minas JL04HV-2E22-22PE Service manual Servo Driver Panasonic
Abstract: the needs of two operating modes; the Regenerative DC Bus Supply mode and the Regenerative Brake mode , . In the Regenerative Brake Mode the 1336 REGEN is used to remove braking energy from the DC bus and , to the converter. When configured as a regenerative brake, a 3% 1321 line reactor will be required to limit current harmonics on the AC line and to provide impedance between the regenerative brake , Regenerative Brake operation requires a standard Bulletin 1321 3% line reactor. The mode of operation is Rockwell Automation
Original
1336-WB035 1336-MOD-KB005 1321-3RB400-B 1336-WB110 1336-WB110 manual circuit 1336-MOD-KB050 D-UM006 PFLEX-RM002 20D-TD001 PFLEX-AT001 PFLEX-IN006 20D-UM001
Abstract: boost 0 to 15% dc injection brake Time (0-10sec), voltage (0-15%), frequency (3Hz fixed) Regenerative brake 0.18k 150% and more, 0.37k, 0.75k, 100% and more Rated overload current 150% for 1min., 200% for , stop the inverter speed operation (0C2) In (0C3) deceleration Regenerative If regenerative energy , (3 modes). Regenerative overvoltage shut off. Overload shut off (thermal relay). Stall prevention RS Components
Original
B16752 FR-U120S FR-U120 5v dc to 220v ac inverter FRU120S mitsubishi overload relay dc motor control circuit 220v dc 0-120H 0-60H
Abstract: (for connection with PC) DV0P1960 Brake cable Note) 2 Regenerative resistor Noise filter , Rated current (Arms) 1.0 1.6 2.5 Max. current (Ao-p) Regenerative brake frequency Note)1 , ) 1.0 1.0 1.6 2.5 Max. current (Ao-p) 4.3 4.3 7.5 11.7 Regenerative brake , Thrust load (A, B) direction A Motor B Note) 1. Regenerative brake frequency represents the , ・ When the motor speed exceeds the rated speed, regenerative brake frequency is in inverse Panasonic
Original
DV0P37300 DV0P3811 Z15D151
Abstract: STEVAL-IHM027V1 Power board with MC connector based on the STGIPS10K60A 10 A, 600 V intelligent power module Data brief Features â  Minimum input voltage: 125 VDC or 90 VAC â  Maximum input voltage: 350 VDC or 220 VAC â  Capable of using external +15 V supply voltage â  Maximum output power for motor: 1000 W â  Regenerative brake control feature â  Input inrush limitation with bypassing relay â  +15 V auxiliary power supply based on buck converter with VIPer16 STMicroelectronics
Original
STM3210B-EVAL
Abstract: STEVAL-IHM025V1 1 kW 3-phase motor control demonstration board featuring the IGBT intelligent power module STGIPL14K60 Data brief Features Min. input voltage: 125 VDC or 90 VAC Max. input voltage: 400 VDC or 285 VAC Max. output power for motors up to 1000 W Regenerative brake control feature Input inrush limitation with bypassing relay +15 V auxiliary power supply based on buck converter with VIPer16 Uses IGBT intelligent power module STGIPL14K60 in STMicroelectronics
Original
VIPer16 applications schematic diagram ac-dc inverter Power INVERTER schematic circuit VIPer16 igbt inverter schematic induction use igbt for 3 phase induction motor
Abstract: STEVAL-IHM027V1 Power board with MC connector based on the STGIPS10K60A 10 A, 600 V intelligent power module Data brief Features Minimum input voltage: 125 VDC or 90 VAC Maximum input voltage: 350 VDC or 220 VAC Capable of using external +15 V supply voltage Maximum output power for motor: 1000 W Regenerative brake control feature Input inrush limitation with bypassing relay +15 V auxiliary power supply based on buck converter with VIPer16 STMicroelectronics
Original
bldc motor control circuit diagrams ac Inverter schematics 10 kw PMSM 2 KW ac Inverter schematics 5 kw IPM STMicroelectronics induction motor
Abstract: frequency pattern Frequency range, starting frequency Voltage boost dc injection brake Regenerative brake Rated overload current Stall prevention function level Operation specifications Frequency , deceleration (0C3) Regenerative overvoltage shut If regenerative energy braking causes dc voltage of the , . 0-120Hz. Min. 0-60Hz. adjustable Overcurrent shut off (3 modes). Regenerative overvoltage shut off RS Components
Original
mitsubishi contactor DC injection brake acceleration time of dc motor 3 phase inverter circuit design 3 phase inverter circuit control fru120
Abstract: ). 104 4.9.2 Selection of a regenerative brake (Pr. 30, Pr. 70 , a fire. When using a brake resistor, make up a sequence that will turn off power when an alarm signal is output. Otherwise, the brake resistor may excessively overheat due to damage of the brake , prevent an accidental failure, (power off, mechanical brake operation for emergency injury, electric , brake which will prevent the machine and equipment from hazardous conditions if the inverter fails Mitsubishi
Original
FR-D700 FR-D740-012 diagram wiring mitsubishi elevator mitsubishi MODBUS RTU FR-D740-036 FR-D740-120 FR-D700-EC FR-D720S-008 IB-0600352ENG
Abstract: frequency pattern Frequency range, starting frequency Voltage boost dc injection brake Regenerative brake Rated overload current Stall prevention function level Operation specifications Frequency , deceleration (0C3) Regenerative overvoltage shut If regenerative energy braking causes dc voltage of the , . 0-120Hz. Min. 0-60Hz. adjustable Overcurrent shut off (3 modes). Regenerative overvoltage shut off RS Components
Original
3 phase regenerative braking 220v motor overload protection DC injection brake mitsubishi 0.4kw overcurrent inverter protection
Abstract: ) 4.3 Without option No limit 2 DV0P2891 1 No limit 2 le* Regenerative brake , option No limit 2 With external brake resistor Regenerative brake frequency (times/min)1 , (including internal 8-speed)â' and â'Torqueâ' command control modes. â'¢ Discharges regenerative , optional regenerative resistor. â'¢ You can combine command control modes in a hybrid mode and switch , , connecting an optional regenerative resistor will add even more regenerative capability. MONITORING Panasonic
Original
FPG-C32T2 MSMD022P1C panaterm setup software RM1205-9
Abstract: De-energize Line/DB Contactor (M) Coil Dynamic Brake Speed Command brought to Zero Volts Regenerative Brake Open Enable Input Regenerative Brake DROK Opens (Fault) Coast to Stop Dynamic Braking - When the line , energy generated by the motor during regenerative braking. â'¢ Velocity loop components to compensate , terminal block. These contacts can be used in a motor brake control circuit or as an indicator that the , applications such as an overhauling load have more regenerative energy to dissipate. For these applications, an -
OCR Scan
300v dc 230v DC motor speed controllers Allen-bradley servo motor 1326 1391-T100DT 1388-XA Allen-bradley DC servo motor 1326 transformer core 2500 kVA 1326AB-BXX 1326AB-AXX 1326-CPCXX
Abstract: be switched OFF. A continuous flow of large current could cause a fire. When using a brake resistor , the brake resistor may overheat due to damage of the brake transistor and possibly cause a fire. Do , rotation direction of the motor. A safety backup such as an emergency brake must be provided to prevent , make an emergency stop (power OFF, mechanical brake operation for emergency stop, etc.) must be , motor and machine must be fully examined. Stop status cannot be hold by the inverter's brake function Mitsubishi
Original
NEC MYS FR-BLF EARTH LEAKAGE RELAY mitsubishi NEC MYS 502 NEC MYS micro controls S-N10 Magnetic Contactor FR-D720-0 FR-D740-0 FR-D720S-0 FR-D710W-0
Abstract: lower arm of IPM. c) Current rating of brake part increased. 50% for the current rating of inverter part. â'¢ 3Ï 100A, 1200V Current-sense IGBT type inverter â'¢ 50A, 1200V Current-sense regenerative brake IGBT â'¢ Monolithic gate drive & protection logic â'¢ Detection, protection & status indication , 20 V 20 V 20 V 20 mA BRAKE PART Symbol VCES IC ICP PC VR(DC) IF Tj , element) Inverter FWDi part (per 1 element) Brake IGBT part Brake FWDi part Inverter IGBT part (per 1 Mitsubishi
Original
U 665 PM100RLA120
Abstract: series. d) Current rating of brake part increased. 53% for the current rating of inverter part. â'¢ 3Ï 75A, 1200V Current-sense IGBT type inverter â'¢ 40A, 1200V Current-sense regenerative brake IGBT â , 20 V 20 V 20 mA BRAKE PART Symbol VCES IC ICP PC VR(DC) IF Tj Parameter , Thermal Resistance Inverter IGBT (per 1 element) Inverter FWDi (per 1 element) Brake IGBT Brake FWDi Inverter IGBT (per 1 element) Inverter FWDi (per 1 element) Brake IGBT Brake FWDi Case to fin, (per 1 Mitsubishi
Original
PM75RLB120 E80276 E80271
Abstract: lower arm of IPM. c) Current rating of brake part increased. 50% for the current rating of inverter part. â'¢ 3Ï 200A, 600V Current-sense IGBT type inverter â'¢ 100A, 600V Current-sense regenerative brake IGBT â'¢ Monolithic gate drive & protection logic â'¢ Detection, protection & status indication , Unit V A A W V A °C Ratings Unit 20 V 20 V 20 V 20 mA BRAKE , Resistance Inverter IGBT (per 1 element) Inverter FWDi (per 1 element) Brake IGBT Brake FWDi Inverter Mitsubishi
Original
PM200RLA060
Showing first 20 results.