500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : EFR-DI-DEINTERLACER-SITE Supplier : Xilinx Manufacturer : Avnet Stock : - Best Price : $807.0400 Price Each : $807.0400
Part : EFR-DI-DISPLAYPORT-SITE Supplier : Xilinx Manufacturer : Avnet Stock : - Best Price : $3880.00 Price Each : $3880.00
Part : EFR-DI-DPD-SITE Supplier : Xilinx Manufacturer : Avnet Stock : - Best Price : €15,046.0068 Price Each : €15,046.0068
Part : RDI-D-L Supplier : Honeywell Manufacturer : Newark element14 Stock : - Best Price : $217.14 Price Each : $248.73
Part : RDI-D-R Supplier : Honeywell Manufacturer : Newark element14 Stock : - Best Price : $217.14 Price Each : $248.73
Part : RDI-D-L Supplier : Honeywell Manufacturer : Master Electronics Stock : 2 Best Price : $146.68 Price Each : $168.00
Part : RDI-D-L Supplier : Honeywell Manufacturer : Sager Stock : - Best Price : - Price Each : -
Part : RDI-D-R Supplier : Honeywell Manufacturer : Sager Stock : - Best Price : - Price Each : -
Shipping cost not included. Currency conversions are estimated. 

rdid

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Instruction Codes Read Identification (3-byte addressing) RDID Read Identification JEDEC 9Fh 9Fh , The S25FL-S family supports standard READ-ID (90h), RDID (9Fh), and RES (ABh) device identification , MB. Table 2.3 Product Identification - READ-ID Device Primary Erase Block Size RDID Byte 0 Mfg ID RDID Byte 1 Device ID RDID Byte 2 Device ID RDID Byte 3 Extended Bytes RDID Byte 4 Extended Bytes RDID Byte 5 Reserved RDID Byte 6 Reserved S25FL032P 64 kB Spansion
Original
S25FL064P S25FL128P S25FL129P S70FL256P S25FL128S S25FL512S S25FL256 S25FL256s S25FL256P S25FL512 S25FL256S
Abstract: Table 1. COMMAND DEFINITION Command Set RDID 1st byte (fast read data) 4th byte , 5 REV. 1.5, NOV. 09, 2007 MX23L3254 COMMAND DESCRIPTION (1) Read Identification (RDID) The RDID instruction is for reading the manufacturer ID of 1-byte and is followed by Device ID of 2 , individual device ID of second-byte ID is:16h. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data is sent out on SO -> to end RDID operation which can use Macronix International
Original
MX23L3254MC-20G PM1246 IN3064 mxic 32M-BIT 16-PIN 16-SOP
Abstract: Table 1. COMMAND DEFINITION Command Set RDID 1st byte (fast read data) 4th byte , 5 REV. 1.5, NOV. 09, 2007 MX23L1654 COMMAND DESCRIPTION (1) Read Identification (RDID) The RDID instruction is for reading the manufacturer ID of 1-byte and is followed by Device ID of 2 , individual device ID of second-byte ID is:15h. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data is sent out on SO -> to end RDID operation which can use Macronix International
Original
MX23L1654MC-20G 16M-BIT PM1247
Abstract: . 1.7, NOV. 09, 2007 MX23L12854 Table 1. COMMAND DEFINITION Command Set RDID 1st byte , DESCRIPTION (1) Read Identification (RDID) The RDID instruction is for reading the manufacturer ID of 1 , issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data is sent out on SO -> to end RDID operation which can use CS# to be high at any time during data out. (see Figure 3) When CS# goes high, the device is at standby stage. Table of ID Definitions: RDID Macronix International
Original
MX23L12854MC-20G 128M-BIT PM1141
Abstract: Table 1. COMMAND DEFINITION Command Set RDID 1st byte (fast read data) 4th byte , 5 REV. 1.8, NOV. 09, 2007 MX23L6454 COMMAND DESCRIPTION (1) Read Identification (RDID) The RDID instruction is for reading the manufacturer ID of 1-byte and is followed by Device ID of 2 , individual device ID of second-byte ID is:17h. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data is sent out on SO -> to end RDID operation which can use Macronix International
Original
MX23L6454MC-20G 64M-BIT PM1127
Abstract: . Figure 1. Read Identification (RDID) Instruction Sequence and Data-Out Sequence S 0 1 2 3 , MSB MSB AI06809 The Read Identification (RDID) instruction, whose op-code is 9Fh, allows the , manufacturer-dependent data bytes. Table 1. Extended Read Identification (RDID) Data-Out Sequence Manufact Device , sequence is shown in Figure 1. The Read Identification (RDID) instruction is terminated by driving Chip , office for availability. Table 4. Read Identification (RDID) Data-Out Sequence for Current, and STMicroelectronics
Original
AN1996 M45PE32 M25PE32 M45PE64 M25PE64 M25PExx M25PXX 25PE16
Abstract: Action sets the (WEL) write enable latch bit WRDI (write disable) 04 Hex RDID (read , instructions: RDID, RDSR, READ, FAST_READ, RES, and REMS-the shifted-in instruction sequence is followed by a , ) instruction completion - Chip Erase (CE) instruction completion (3) Read Identification (RDID) The RDID , device ID of second-byte ID is as followings: 15(hex) for MX25L1605. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data out on SO -> to end RDID Macronix International
Original
MX25L1605ZM 25l1605 8x6mm 256-Byte MX25L1605ZMC-20G MX25L1605ZMI-20G PM1291
Abstract: 4th 5th Action sets the (WEL) write enable latch bit WRDI (write disable) 04 Hex RDID (read , the following instructions: RDID, RDSR, READ, FAST_READ, RES, and REMS-the shifted-in instruction , Chip Erase (CE) instruction completion (3) Read Identification (RDID) The RDID instruction is for , second-byte ID is as followings: 16(hex) for MX25L3205A. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data out on SO -> to end RDID operation can use CS Macronix International
Original
MXIC serial Flash OCT/13/2005 JUN/08/2006 NOV/06/2006 PM1243
Abstract: Action sets the (WEL) write enable latch bit WRDI (write disable) 04 Hex RDID (read , 0 and mode 3 is shown as Figure 3. 5. For the following instructions: RDID, RDSR, READ, FAST_READ , (CE) instruction completion (3) Read Identification (RDID) The RDID instruction is for reading the , followings: 15(hex) for MX25L1605. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data out on SO -> to end RDID operation can use CS# to high at any time during Macronix International
Original
MX25L1605M MX25L6405 C214P MX25L1605MC PM1168 MX25L3205
Abstract: 5th Action sets the (WEL) write enable latch bit WRDI (write disable) 04 Hex RDID , 0 and mode 3 is shown as Figure 3. 5. For the following instructions: RDID, RDSR, READ, FAST_READ , (CE) instruction completion (3) Read Identification (RDID) The RDID instruction is for reading the , followings: 15(hex) for MX25L1605. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data out on SO -> to end RDID operation can use CS# to high at any time during Macronix International
Original
JUL/15/2005 MAY/16/2006
Abstract: (write disable) 04 Hex RDID (read identification) 9F Hex reset the (WEL) write enable latch , 0 and mode 3 is shown as Figure 3. 5. For the following instructions: RDID, RDSR, READ, FAST_READ , (CE) instruction completion (3) Read Identification (RDID) The RDID instruction is for reading the , followings: 16(hex) for MX25L3205. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data out on SO -> to end RDID operation can use CS# to high at any time during Macronix International
Original
MXIC sequential PM1169 JUN/12/2006
Abstract: RDID Description Read Data Bytes Read Data Bytes at Higher Speed Read Identification One-byte , (RDID) The Read Identification (RDID) instruction allows the 8-bit manufacturer identification to be , the second byte (17h). The Read Identification (RDID) instruction should not be issued while the , Identification (RDID) instruction is terminated by driving Chip Select (S#) High at any time during data output , . Table 2. Read Identification (RDID) Data-Out Sequence Device Identification Manufacturer Identification Macronix International
Original
MX23L6454MC-20 MX23L6454MI-20G MAR/02/2005 MAR/09/2005 SEP/23/2005 SEP/27/2005
Abstract: Dummy Bytes 0 1 0 Data Bytes 1 to 1 to 1 to 3 FAST_READ Read Data Bytes at Higher Speed RDID Read Identification P/N: PM1141 6 REV. 1.6, NOV. 07, 2006 MX23L12854 Read Identification (RDID) The Read Identification (RDID) instruction allows the 8-bit manufacturer identification to be read , (18h). The Read Identification (RDID) instruction should not be issued while the device is in Deep , edge of Serial Clock (C). The instruction sequence is shown in Figure 4. The Read Identification (RDID Macronix International
Original
APR/06/2005 MAY/04/2005 OCT/21/2005 NOV/03/2005 NOV/07/2006
Abstract: 4th 5th Action sets the (WEL) write enable latch bit WRDI (write disable) 04 Hex RDID (read , the following instructions: RDID, RDSR, READ, FAST_READ, RES, and REMS-the shifted-in instruction , Chip Erase (CE) instruction completion (3) Read Identification (RDID) The RDID instruction is for , second-byte ID is as followings: 15(hex) for MX25L1605. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data out on SO -> to end RDID operation can use CS Macronix International
Original
BP200 ad20bit4
Abstract: sets the (WEL) write enable latch bit WRDI (write disable) 04 Hex RDID (read identification) 9F Hex , the following instructions: RDID, RDSR, READ, FAST_READ, RES, and REMS-the shifted-in instruction , Chip Erase (CE) instruction completion (3) Read Identification (RDID) The RDID instruction is for , second-byte ID is as followings: 16(hex) for MX25L3205. The sequence of issuing RDID instruction is: CS# goes low-> sending RDID instruction code -> 24-bits ID data out on SO -> to end RDID operation can use CS Macronix International
Original
25L3205
Abstract: shifted out. Table 1. Instruction Set Instruction READ FAST_READ RDID Description Read Data Bytes Read , REV. 1.4, NOV. 07, 2006 MX23L1654 Read Identification (RDID) The Read Identification (RDID , (RDID) instruction should not be issued while the device is in Deep Power-down mode. The device is first , instruction sequence is shown in Figure 4. The Read Identification (RDID) instruction is terminated by driving , that it can receive, decode and execute instructions. Table 2. Read Identification (RDID) Data-Out Macronix International
Original
MX23L1654MC-20 MX23L1654MI-20G DEC/05/2005
Abstract: (except RDID command and part of protection), also available in 0 to 70°C, see also M25PExx/M45PExx series SO8N instead of DIP, software compatible (except RDID command and part of protection), also , RDID command), also available in 0 to 70°C, see also M25PExx/ M45PExx series SO8N instead of DIP, software compatible (except RDID command), also available in 0 to 70°C, see also M25PExx/ M45PExx series Footprint compatible, software compatible (except RDID command), also available in 0 to 70°C, see also STMicroelectronics
Original
PM25LV040 PM25LV020 SO8w footprint MX25L8005M2C-15G MX25L8005M2C ICE25P05 CRSERFLASH0705
Abstract: . 8 9.1. READ IDENTIFICATION (RDID , 0011 03h FAST_READ Read Data Bytes at Higher Speed 0000 1011 RDID Read Identification 1001 1111 9.1. Read Identification (RDID) The Read Identification (RDID) instruction allows the 8 , (RDID) instruction is terminated by driving The Read Identification (RDID) instruction should not be , Identification (RDID) Data-Out Sequence Device Identification Manufacturer Identification Memory Type Generalplus Technology
Original
GPR26L080A JESD22-A114A
Abstract: Identification (RDID), the shifted-in instruction sequence is followed by a data-out sequence. Chip Select (S , Read Data Bytes at Higher Speed RDID Read Identification P/N: PM1246 6 REV. 1.4, NOV. 07, 2006 MX23L3254 Read Identification (RDID) The Read Identification (RDID) instruction allows the 8 , capacity of the device in the second byte (16h). The Read Identification (RDID) instruction should not be , in Figure 4. The Read Identification (RDID) instruction is terminated by driving Chip Select (S Macronix International
Original
MX23L3254MC-20 MX23L3254MI-20G
Abstract: MSB 2 17 D a ta 9.3 S h e e t ID RDID ID RDID1 ID 2 ID ID JEDEC Spansion , . 9.3 ID RDID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.4 ID READ_ID[RDID ]. . . . . . . . . . . . . . . . . . . . . . . , . . . . 17 ID RDID . . . . . . . . . . . . . . . . . . 18 READ_ID . . . . . . . . . . . . . . . , . . . . . . . .15 S25FL040A . . . . . . . . . . . . . . . . . . . . . . . . . .16 RDID . . . . -
Original
S25FL004A A42006 FL040A S25FL S25FL-A SA12 A2006 B02006 B12007 B22007
Showing first 20 results.