500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LT1949-1EMS8TR Linear Technology IC PWM DC/DC CONV 1A SWTCH 8MSOP visit Linear Technology - Now Part of Analog Devices
LT1619EMS8 Linear Technology LT1619 - Low Voltage Current Mode PWM Controller; Package: MSOP; Pins: 8; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT1619ES8#TR Linear Technology LT1619 - Low Voltage Current Mode PWM Controller; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT1619ES8#PBF Linear Technology LT1619 - Low Voltage Current Mode PWM Controller; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT1619ES8#TRPBF Linear Technology LT1619 - Low Voltage Current Mode PWM Controller; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT1619ES8 Linear Technology LT1619 - Low Voltage Current Mode PWM Controller; Package: SO; Pins: 8; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy

pulse doppler radar

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: suited for pulse Doppler radar simulation. HP 8791 Model 11 with optional external upconverter HP , a traditional signal generator. The Model 200 radar simulator features various pulse modulations , Arbitrary control over AM, FM, ⌽M, pulse, and frequency hop Easy-to-use application-specific software , and pulse modulation data. This data is supplied to the agile carrier synthesizer, where it is , ), Frequency Agile Signal Simulators 1 High-Precision Signals for EW, Radar, and Advanced Communications Hewlett-Packard
Original

pulse doppler radar

Abstract: radar digital correlator Solutions Challenge in the domain of pulse Doppler radar. Our project deals with the pulse compression , in digital pulse compression (DPC) radar sub-systems. Presently, only an exhaustive search is able , technique used in pulsed coherent radar to increase the energy transmitted per pulse without sacrificing , . First of all, we learned a lot about radar fundamentals and Digital Pulse Compression. Moreover, it , .9 Fundamentals of Digital Pulse Compression . 10
Texas Instruments
Original

architecture of TMS320C50

Abstract: pulse doppler radar Solutions Challenge in the domain of pulse Doppler radar. Our project deals with the pulse compression , in digital pulse compression (DPC) radar sub-systems. Presently, only an exhaustive search is able , technique used in pulsed coherent radar to increase the energy transmitted per pulse without sacrificing , . First of all, we learned a lot about radar fundamentals and Digital Pulse Compression. Moreover, it , .9 Fundamentals of Digital Pulse Compression . 10
Texas Instruments
Original

circuit diagram of MOD 64 counter

Abstract: a6069 ADF4196 suitable for pulse Doppler radar applications. The ADF4196 consists of a low noise, digital phase , GSM/EDGE base stations PHS base stations Pulse Doppler radar Instrumentation and test equipment , eliminate the need for ping-pong solutions. It can also be used in pulse Doppler radar applications. The , time CLK high duration CLK low duration CLK to LE setup time LE pulse width Timing Diagram t4 , with a pulse width difference that is proportional to the phase difference between the inputs. The
Analog Devices
Original
circuit diagram of MOD 64 counter a6069 MO-220-VHHD-2 CP-32-2 ADF4196BCPZ ADF4196BCPZ-RL7 EVAL-ADF4193EBZ1 EVAL-ADF4193EBZ2
Abstract: ADF4196 suitable for pulse Doppler radar applications. The ADF4196 consists of a low noise, digital phase , GSM/EDGE base stations PHS base stations Pulse Doppler radar Instrumentation and test equipment , eliminate the need for ping-pong solutions. It can also be used in pulse Doppler radar applications. The , duration CLK low duration CLK to LE setup time LE pulse width Timing Diagram t4 t5 CLK t2 , with a pulse width difference that is proportional to the phase difference between the inputs. The Analog Devices
Original
GSM1800 ADF4193 D09450-0-12/11

pulse doppler radar

Abstract: 06333 settling feature makes the ADF4196 suitable for pulse Doppler radar applications. The ADF4196 consists of a , base stations PHS base stations Pulse Doppler radar Instrumentation and test equipment Beam-forming , solutions. It can also be used in pulse Doppler radar applications. The ADF4196 works on the basis of fast , CLK high duration CLK low duration CLK to LE setup time LE pulse width Timing Diagram t4 CLK , outputs with a pulse width difference that is proportional to the phase difference between the inputs. The
Analog Devices
Original
pulse doppler radar 06333 4 bit mod 16 d flip-flop d0945 VCO190-1843T D09450-0-10/11
Abstract: settling feature makes the ADF4196 suitable for pulse Doppler radar applications. The ADF4196 consists of a , base stations PHS base stations Pulse Doppler radar Instrumentation and test equipment Beam-forming , eliminate the need for ping-pong solutions. It can also be used in pulse Doppler radar applications. The , CLK high duration CLK low duration CLK to LE setup time LE pulse width Timing Diagram t4 CLK , down outputs with a pulse width difference that is proportional to the phase difference between the Analog Devices
Original
EV-ADF4196SD1Z D09450-0-1/13

doppler radar

Abstract: abstract for robotics project Pulse Compression and Doppler Digital Filtering. AXIR ( Automatic Xband Instrumentation Radar ) is a , Monopulse Doppler Radar SPRA299 Overview of the Calculation Figure 3. Digital Pulse Compression , Processing for Monopulse Doppler Radar Authors: P.H. Dezaux, X. Gilles, S. Marques EFRIE, France , . 23 Front-End Processing for Monopulse Doppler Radar Abstract FEPMR is standing for Front-End and Doppler Processing for Monopulse Doppler Radar. It is a PCB at the frontier between the RF
Texas Instruments
Original
doppler radar abstract for robotics project diagram radar circuit doppler sensor rf doppler sensor architecture of TMS320C50

doppler radar

Abstract: pulse doppler radar Pulse Compression and Doppler Digital Filtering. AXIR ( Automatic Xband Instrumentation Radar ) is a , Monopulse Doppler Radar SPRA299 Overview of the Calculation Figure 3. Digital Pulse Compression , Processing for Monopulse Doppler Radar Authors: P.H. Dezaux, X. Gilles, S. Marques EFRIE, France , . 23 Front-End Processing for Monopulse Doppler Radar Abstract FEPMR is standing for Front-End and Doppler Processing for Monopulse Doppler Radar. It is a PCB at the frontier between the RF
Texas Instruments
Original
Monopulse radar circuit component Ground Radar diagram radar dsp processor sensor doppler array pulse compression

doppler radar

Abstract: Types of Radar Antenna Monopulse Doppler Radar and DSP Teaching Authors: P-H Dezaux, X. Gilles, S. Marques, L. Fourdan , . 20 Digital Monopulse Doppler Radar and DSP Teaching Abstract In 1995 several teams of , (hardware and software) associated with a new class of a Digital Monopulse Doppler Radar. The study has , Circuit Board) 1) Front-End Processor (Digital Pulse Compression and Doppler Filtering) 2) Tracker , general instrumentation. Digital Monopulse Doppler Radar and DSP Teaching 7 SPRA342 This
Texas Instruments
Original
Types of Radar Antenna instrumentation and control schools projects DOPPLER circuit Doppler radar dsp processor Introduction to Radar texas instruments radar

sample project texas instruments radar

Abstract: how dsp is used in radar communicates through dual access memory with AXIR_A (Doppler processing) and AXIR_C (Radar Manager) projects , display. The AXIR is basically a monopulse Doppler ground base radar. Numerous AXIR civilian applications , are named: a) Front-end/Doppler Processing b) Digital Tracker (AXIR B) c) Adaptive Radar Manager d , Tracking Several Doppler measurements (coherent bursts) are operated with at least 3 different Pulse , calculated by the Radar Manager and only the central Doppler filter is used for the calculus of the
Texas Instruments
Original
TMS320C40 sample project texas instruments radar how dsp is used in radar motion sensor doppler effect motion sensor doppler motion DOPPLER SPRA301

motion sensor doppler

Abstract: how dsp is used in radar communicates through dual access memory with AXIR_A (Doppler processing) and AXIR_C (Radar Manager) projects , display. The AXIR is basically a monopulse Doppler ground base radar. Numerous AXIR civilian applications , are named: a) Front-end/Doppler Processing b) Digital Tracker (AXIR B) c) Adaptive Radar Manager d , Tracking Several Doppler measurements (coherent bursts) are operated with at least 3 different Pulse , calculated by the Radar Manager and only the central Doppler filter is used for the calculus of the
Texas Instruments
Original
motion sensor based on doppler effect radar block diagram radar sensor specification radar circuit schematic true beam sensor instrumentation projects

motion sensor doppler

Abstract: on off 555 timer using relay drive for signals S1 to S5, for one Doppler pulse and three pulses respectively c Status diagram of CMOS , : fully-equipped power stage and relay driver circuit. Right: the entire evaluation electronics with Doppler radar , .: Doppler module KMY 24: Radar sensor detects motion and direction. Components XXXI (1996) No. 3, pp. 30 to , Doppler module KMY 24: Motion makes a room light up Automatic light switches based on Doppler , patent is pending, was triggered off when the KMY 24 Doppler module became ready for largescale
Siemens
Original
on off 555 timer using relay drive lm 555 timer microwave RADAR motion sensors 555 timer project 4538A LIGHT ACTIVATED SWITCH CIRCUIT DIAGRAM

Types of Radar Antenna

Abstract: DRFM unique in that it doesn't require information from radar data buses: all the radar pulse/PRI/dwell , Multi-point target: from 1 to 32 returns/pulse â'¢ Up to 83K reflectors/target â'¢ Amplitude/delay/Doppler , ¡¡¡¡¡¡¡¡SYSTEM^ INC./ a HERLEy company DRFM-based Radar Environment Simulator Maximum versatility for radar testing and operating training. â'¢ Digital RF Memory-based waveform , radar performance verification, radar mode and ECCM technique development, radar production testing, and
-
OCR Scan
VME64 DRFM For remote control helicopter applications for doppler radar doppler Types of Radar herley drfm

police radar detector

Abstract: DOPPLER 10.525 ghz only a small fraction of the signal frequency. DOPPLER RADAR - A typical Doppler radar system consists , a Doppler radar system, one must first know: 1. The maximum range at which the target is to be , Doppler shift of 1568 Hz. A police radar's IF amplifier bandpass frequency should be approx imately 50 Hz , amplifier). The commercial Doppler systems, such as police radars and intrusion alarms usually operate with , for the mixer. Using this technique, the signal amplification will occur at the Doppler shift
-
OCR Scan
police radar detector DOPPLER 10.525 ghz radar detector detector FM TRANSMITTER CIRCUIT Gunn Diode at power supply circuit varactor diode for x band radar police radar detector receiver A01803

DRFM

Abstract: Chameleon /V/^7/7 SYSTEMS, INC.I a HERLEy company CHAMELEON II Radar Target and ECM Simulator Powerful , to DRFM memory, including digital receiver â'¢ Radar target modeling and clutter â'¢ Advanced ECM , features radar target modeling, clutter, and ECM signal generation using a full software GUI running under , '¢ Up to 8 memory files â'¢ User read/write to memory â'¢ 10 MHz Doppler at 0.5 Hz resolution â'¢ RF , , capture-delay modes â'¢ RF bypass modes â'¢ 4 coherent Doppler channels per DRFM â'¢ Maximum range delay >8
-
OCR Scan
Chameleon Chameleon Systems elint DOPPLER velocity log

code for gabor filter

Abstract: time-frequency spectrogram Radar .2 Dr. Victor C. Chen, Code 5360.1 Airborne Branch, Radar Division Naval Research Laboratory 4555 , Radar Inverse synthetic aperture radar (ISAR) is an imaging radar that uses the target's pitch, roll , time history series. The DFT of the time history series gives an N-point Doppler spectrum. Finally, by combining the M Doppler spectra from M range cells, the M-by-N ISAR image is formed. The range resolution of
National Instruments
Original
code for gabor filter time-frequency spectrogram ultrasonic radar ultrasonic generator 1 Mhz ultrasonic doppler economic industry and company analysis T15A0 T15A1

ARINC 708

Abstract: 34FAX -7708BRW Weather Radar Bench Test (78.6616 MHz) 1 Hz OUTPUT PULSE WIDTH Range 0 to 99 ms and 270 µs (fixed , issue3.qxd 02/Dec/2004 10:50 Page 1 Avionics RDX-7708 Weather Radar Test Set Comprehensive RF Test Set for ARINC 708 Solid State Coherent Weather Radar Systems · Endorsed by OEM Weather Radar System manufacturers Additional Features · Range reply selectable in 1 µs or 1 mile increments · Built-in Doppler shift · RF output adjustable in 1 dBm increments to -127 dBm ·
Aeroflex
Original
RDX-7708R ARINC 708 34FAX RDX-7708BRW weather radar arinc 708 RDX 7708

ZR34161

Abstract: zoran zr 1000 306 237 164 26 53 52 33 MAIN RADAR PULSE DATA Figure 1. Quadrature-receiver Doppler Application MEMORY BUFFER 1 LPF DECIMATION (-4 ) f \ J â' HftD I-C BUFFER B 128 PT. FFT DISPIA» PROCESSOR M AG SO (X I Figure 2. Radar Application 1 1 VSP , corresponds to the doppler frequency of interest Radar: The FFT is a key function in radars. new dimension , : â'¢ Performance Benchmarks Radar/Sonar Image Processing Communications Image/Data
-
OCR Scan
ZR34161 zoran zr ZR3416

doppler radar

Abstract: CS-4012 uses an unattended UHF clear-air Doppler radar to profile the upper winds with a maximum height of , Profiler System is different from S Band weather radars such as the Next Generation Weather Radar (NEXRAD) or Terminal Doppler Weather Radar (TDWS); S Band radars rely on the turbulence signature of water , order to detect clear air turbulence to a height of 16.25 Km, the CS-4012 radar receiver must be able , floor to full limiting Video Gain: 3.5 dB Max Safe RF Input: +20 dBm, CW & Pulse Image
Aeroflex Comstron
Original
4012 S 4012 R Comstron front-end radar
Showing first 20 results.