500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
SENSOREVAL Texas Instruments Eval Board Software For Hardware Monitors And Digital Temperature Sensors visit Texas Instruments
TMP275DGK Texas Instruments Switch/Digital Output Temperature Sensor, DIGITAL TEMP SENSOR-SERIAL, 12BIT(s), 1.5Cel, MSOP-8 visit Texas Instruments
LM94021BIMGX Texas Instruments Analog Temperature Sensor, ANALOG TEMP SENSOR-VOLTAGE, 1.36V, 2.70Cel, RECTANGULAR, SURFACE MOUNT, SC-70, 5 PIN visit Texas Instruments
HDC1000YPAR Texas Instruments Low Power, 3% Accuracy Digital Humidity Sensor with Integrated Temperature Sensor 8-DSBGA -40 to 125 visit Texas Instruments
HDC1008YPAT Texas Instruments Low Power, 4% Accuracy Digital Humidity Sensor with Integrated Temperature Sensor 8-DSBGA -40 to 125 visit Texas Instruments
HDC1080DMBR Texas Instruments HDC1080 Low Power, High Accuracy Digital Humidity Sensor with Temperature Sensor 6-WSON -40 to 125 visit Texas Instruments

ptc temperature sensor 400c

Catalog Datasheet MFG & Type PDF Document Tags

manual gefran 2300

Abstract: gefran 200 4T 48 / 4T 96 TEMPERATURE INDICATOR with CONFIGURABLE INPUT Main features Main applications , Pt100, Pt100J (japanese standard) 2 / 3 wire · PTC and NTC themistors · Linear inputs 0 to 60/12 to , TECHNICAL DATA INPUTS Accuracy 0,2% f.s. ±1digit. Sampling time 120msec for temperature sensors , . Configurable decimal point position for linear inputs, for TC, RTD, PTC and NTC inputs, only one decimal , (3 digit display with sign) with indication of open circuit thermocouple or RTD, PTC or NTC in open
GEFRAN
Original

manual gefran 2300

Abstract: gefran 200 , C · Resistance thermometers Pt100, Pt100J (japanese standard) 2 / 3 wire · PTC and NTC themistors , temperature sensors, configurable for linear inputs down to a minimum of 15msec with reduction of the resolution to 2000 steps. Configurable decimal point position for linear inputs, for TC, RTD, PTC and NTC , RTD, PTC or NTC in open or short circuit, indication of overand under-range for linear inputs. TC , 1750°C / 32 to 3182°F S 0 to 1750°C / 32 to 3182°F T -200 to 400°C / -328 to 752°F B 44 to 1800
GEFRAN
Original

manual gefran 2300

Abstract: gefran 200 (japanese standard) 2 / 3 wire · PTC and NTC themistors · Linear inputs 0 to 60/12 to 60mV, 0 to 20/4 to , for temperature sensors, configurable for linear inputs down to a minimum of 15msec with reduction , , PTC and NTC inputs, only one decimal digit is allowed in the maximum display range of -199.9 to , sign) with indication of open circuit thermocouple or RTD, PTC or NTC in open or short circuit , 3182°F S 0 to 1750°C / 32 to 3182°F T -200 to 400°C / -328 to 752°F B 44 to 1800°C / 111 to 3272
GEFRAN
Original

namur ne43

Abstract: Ni100 sensor DIN rail mounting Application: Electronic temperature measurement with resistance sensor or thermocouple sensor. · Ex barrier for temperature sensors, potentiometers and current / voltage signals. · , Pt100/Ni100 sensor, or externally with a constant temperature. If internal compensation is selected, a terminal with a built-in temperature sensor must be ordered separately (PR type no. 5910 and 5913). , standard version can be programmed either for a temperature or a current / voltage input. This means that
PR Electronics
Original

namur ne43

Abstract: Ni100 sensor -channel versions Loop supply > 18 V in Ex zone 0 Application: Electronic temperature measurement with resistance sensor or thermocouple sensor. · Ex barrier for temperature sensors, potentiometers, and current , Pt100 / Ni100 sensor, or externally with a constant temperature. If internal compensation is selected, a connector with a built-in temperature sensor must be ordered separately (PR type no. 5910 and , the standard version can be programmed either for a temperature or a current / voltage input. This
PR Electronics
Original

IEC-60751

Abstract: RH -005c RELAY window. · Sophisticated sensor error surveillance, where one relay holds the state immediately prior to the sensor error, thus allowing the process to continue. The other relay can be set for sensor error alarm so that the defect sensor can be replaced immediately. TC 21 Supply: 33 · A green , . 60 dB (0.100 kHz) Response time (0.90%, 100.10%): Temperature input . 1 s mA / V input. 400 ms Calibration temperature
-
Original

IEC-60751

Abstract: IEC60751 Linearised, electronic temperature measurement with RTD or TC sensor. RTD and lin.R TC Connection , junction compensation (CJC) CJC via external sensor in connector 5910 (based on ambient temperature). < ±1.0 °C ±0.02 °C/ °C CJC via internal sensor (based on temperature inside encl.) . < ±2.0 °C ±0.2 °C , . 60 dB (0.100 kHz) Response time (0.90%, 100.10%): Temperature input . 1 s mA / V input . 400 ms Calibration temperature
PR Electronics
Original

Crouzet Timer 814 manual

Abstract: MUR1 crouzet : underground temperature sensors Underfloor heating Dual-energy water heater Heat control and domestic , inputs Motor Speed setpoint Cutting to length on woodworking machine Temperature controller / Timer / Safety relay Controlling the temperature of the nozzles and mould Automatic management , / Ratemeter P. 32-35 Temperature controller P. 36-37 Safety relay P. 38-39 www.crouzet.com b Counters / Ratemeters Control relay b b b b b b b b b b b Temperature controllers P
Crouzet
Original

JUMO iTRON 08 manual

Abstract: PT100 temperature sensor JUMO manual 0- 0.4% 0.4% 0.4% 0.4% 0.4% 0.4% 0.4% 0.4% 0.4% + 900°C +1200°C + 600°C + 400°C +1372°C +1300°C +1768°C +1768°C 1820 °C Cold junction Ambient temperature error 100 ppm/°C , accuracy Ambient temperature error Pt 100 EN 60 751 2-/3-wire -200 to +850°C 0.1% 50 , 1.0% 50 ppm/°C KTY11-6 2-wire Sensor lead resistance max. 20 per lead for 2- and 3 , signal input Designation Range Measurement accuracy Ambient temperature error Voltage 0
-
Original
JUMO iTRON 08 manual PT100 temperature sensor JUMO manual itron 08 jumo itron 702042 JUMO itRON 08 JUMO iTRON 16 manual

hall effect sensor based non contact tachometer f

Abstract: hall effect sensor based non contact tachometer for electrical motors speed measurements density available to actuate a sensor and the reversible temperature coefficient. Temperature Effects , (-400C) adds flux density to the magnet, while the positive temperature (850C) reduces flux density , Gauss and a minimum BRP of -90Gauss over the temperature range of -400C to 850C. Due to the temperature , , and has pioneered the next generation of programmable sensors and sensor interfaces. This section , programmable sensors and sensor interfaces. It is intended to be useful for the novice as well as the expert
Melexis
Original
hall effect sensor based non contact tachometer f hall effect sensor based non contact tachometer for electrical motors speed measurements u18 sensor hall hall sensor u18 FLUXGATE MLX90237 MLX90308 MLX90215

ABB MP200

Abstract: ABB sattcon 35 channel. MP Measures temperature with a Pt100 sensor. MP is linearized. Six ranges. PIOS/RCA Basic rack PIOS35 with address panel, power supply PSF and 200-RACN/A. MN Measures temperature , Temperature stability Influence of conductor resistance Sensor current (typical) MP160 MN80 MR1000 , modules are for galvanic isolation (MCVG), differential input (MCV200), temperature measurement (MP, MN , temperature stability. If the LED input (current) is used, the intensity of the LED varies with the value
ABB Automation
Original
ABB MP200 ABB sattcon 35 sattcon ABB MP100 SattCon 05 sattcon IBA 200-RANN 200-RACN 89/336/EEC 73/23/EEG

PT100 temperature sensor JUMO

Abstract: PT1000 table % 0.4% 0.4% 0.4% 0.4% Pt 100 internal + 900°C +1200°C + 600°C + 400°C +1372°C +1300°C 1768°C 1768°C 1820 °C Ambient temperature error 100 ppm/°C 100 ppm/°C 100 ppm/°C 100 ppm/°C 100 ppm , temperature error 50 ppm/°C 50 ppm/°C 50 ppm/°C 20 max. per lead for 2- and 3-wire circuit 250µA Not , process value correction. Sensor lead resistance Measurement current Lead compensation Standard , % 0.1% 0.1% 0.1% Ambient temperature error 100 ppm/°C 100 ppm/°C 100 ppm/°C 100 ppm/°C 100
JUMO
Original
PT100 temperature sensor JUMO PT1000 table jumo itron PT100 JUMO signal conditioning circuit for pt100 4-20 mA PROCESS CONTROL TIMER 1-800-554-JUMO

jumo itron

Abstract: PT100 temperature sensor JUMO 900°C +1200°C + 600°C + 400°C +1372°C +1300°C 1768°C 1768°C 1820 °C Cold junction Ambient temperature error 100 ppm/°C 100 ppm/°C 100 ppm/°C 100 ppm/°C 100 ppm/°C 100 ppm/°C 100 , Connection type Range Measurement accuracy Ambient temperature error Pt 100 EN 60 751 2 , 0.1% 50 ppm/°C -50 to +150°C 1.0% 50 ppm/°C KTY11-6 2-wire Sensor lead resistance , Ambient temperature error Voltage 0 - 10V, input resistance RE > 100k 2 - 10V, input resistance
JUMO
Original
jumo ITRON 702043 PT1000 temperature sensor JUMO data sensor KTY11-6 JUMO ITRON 04 PROCESS CONTROL TIMER using relay PT1000 temperature sensor

fuji step motor

Abstract: Reference position Position detection sensor [LS] Target stop point This function is effective in , the Equipment an ambient air temperature of 40ûC and under the load maintenance warning , control with speed range sensor Speed
Fuji Electric
Original
fuji step motor MEH655

Z-SCH230

Abstract: temperature Certification mark Max. line length to the sensor 45 mm 17.5 mm DIN rail II â'"25 °C â , Installation width Mounting Protection class Ambient temperature Max. line length to the sensor 45 mm , Temperature range Total contact gap Contact material *) 240/415 V AC 8 A AC 900 W (cos Ï = 0.45 , (Uimp = 4 kV) Rated insulation voltage Ui Nominal thermal current = Ith 400C 600C Utilisation , Type of connection Terminal capacity Tightening torque Temperature range Operation position
EATON
Original
Z-SCH230 SEACA0102004

rtd 2668

Abstract: power amplifier 3000W with PCB sensor: Type K thermocouple sensor: Temperature Range 0°C to 400°C 0°C to 200°C, 0°C to 400°C Price Each , replacement for an IR32. All types have two sensor inputs, selecteable bewteen NTC, PTC and PT1000, ideal for , Temperature Controller Ì Ì Ì Ì Ì Ì 1 or 2 NTC or PTC input options 1 or 2 independent controllers Up to 3 , Plantinel thermocouples, PT100 2/3 wire, -5 to 56mV, 0 to 10V, 0 to 20mA Sensor Options NTC or PTC Sensor , Sensor type Model 01 Model 02 Temperature ranges PT100 types Thermocouple types Display Offset accuracy
Element14 Catalog
Original
rtd 2668 power amplifier 3000W with PCB ZENER h48 IR32Z relay 3500 2231 021 MTL5018 DM3600U/S1 DM3600U/S2

2XPT100

Abstract: Thermocouple type PT100 jumo JTB/TW Temperaturbegrenzer und -wächter Temperature limiter and monitor Limiteurs et contrôleurs de température B 70.1140.0 Betriebsanleitung Operating Instructions Notice de mise en service , - Thermoelement / Doppel-Thermoelement 11 Analogeingänge Widerstandsthermometer oder KTY11-6 PTC in , Pt 100 DIN EN 60751 Pt 1000 DIN 601 KTY11-6 PTC Fühler in Zweileiterschaltung 003 , -200 . +850 °C 0,1% KTY11-6 PTC -50 . 150 °C 1% Pt 1000 DIN -200 . +850 °C 0
-
Original
2XPT100 Thermocouple type PT100 jumo 2XPT100 JUMO 90D239-F03 Pt30Rh-Pt6Rh 701140 98/ME/NT4 0/2000/XP

phoenix contact 24v 8 channel Relay board with contact details

Abstract: FL20A2MA /ASCII RS485 OI Touchscreen Automation Software Temperature Controller Pentra with Radio , transmission. PLCs Automation Software VFD Temperature Controller Power Supplies Sensors Communication , (NTC/PTC) ­ 12-bit (0-4000) PLCs FC4A-K2C1 2 (2 outputs) ­ -10 to 10V DC, 4-20mA , Operating Temperature Storage Temperature Relative Humidity Altitude Pollution Degree Corrosion Immunity , Inrush Current Power Supply Wire Operating Temperature Storage Temperature Relative Humidity Altitude
IDEC
Original
FC4A-D20RK1 phoenix contact 24v 8 channel Relay board with contact details FL20A2MA KIT-PENTRA-24-HG2G-TE Ni1000 CONVERSION TABLE FC5A-D12 FC41-K4A1 800-262-IDEC 16RS1 FC5A-D32K3 FC5A-D32S3 FC4A-D20RS1

eq7 instruction manual

Abstract: submersible motor winding formula °C - 25 °C . + 75 °C - 25 °C . + 75 °C Temperature Humidity 50.95 %, without
Teco-Westinghouse Motor
Original
eq7 instruction manual submersible motor winding formula
Showing first 20 results.