NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: inputs Number 2 Type Thermocouple Pt100 Sensor connection S 2-wire technique S 2-wire , you select the 2-wire technique, you must jumper terminals M1+ and IC1 or M2+ and IC2. Measurement , influence of the cable length (resistance) on the measurement result will be suppressed. 2-wire technique , information. .you will find supplementary information on analog LOGO! Expansion module AM2 PT100 (order no. , information. Short description of the expansion module AM2 PT100 The analog expansion module AM2 PT100 is ... Original
datasheet

6 pages,
30 Kb

PT100 4 wire temperature sensor siemens Logo with analog input output siemens pt100 siemens Logo 6ed1 manual siemens Logo manual Siemens PT100 w siemens thermocouple Thermocouple type PT100 PT100 thermocouple AM2 Siemens LOGO AM2 pt100 program 050-1AA00-0BE4 PT100 050-1AA00-0BE4 abstract
datasheet frame
Abstract: Local interface Al 1 LI Box header; LI plug connector with ribbon cable 2-wire measuring , Input circuit 1 potential free input for circuit with a temperature sensor of the type PT100 Measuring method: 3-wire / 2-wire with external jumper Measuring input: -50 to +200°C Terminals , influence: Temperature influence: 0.02% / °C Switching point correction necessary (only 2-wire , G2TI1 PT100 Temperature measurement with PT100 sensors (2- and 3-wire connection) Sensor failure ... Original
datasheet

3 pages,
350.15 Kb

pt100 sensor 2-wire interface PT100 4 wire temperature sensor pt100 temperature 3 wire pt100 sensors PT100 class A Pt100-element PT100 2 wire temperature sensor PT100 3 wire temperature sensor PT100 resistance table PT100 PT100 abstract
datasheet frame
Abstract: current output (2-wire output): Range 4.20 mA _ _ Sensor error: Selected value NAMUR NE43 , / voltage signals. · Ex power supply for 2-wire transmitters in zone 0, 1, 2, 20, 21 and 22. · , a 3- or 4-wire connection. At a 2-wire connection the cable resistance can be entered or measured , offset. 50% of selec. max. value Load (min.) . 500 k 2-wire , [] Max. external 2-wire supply . 29 VDC Effect of external 2-wire supply voltage change ... Original
datasheet

4 pages,
375.05 Kb

PT100 standard IEC 60751 accuracy 5114A Pt100 transmitter 4.20 mA NE43 LIMIT SWITCH namur 43 5114B1 namur ne43 Ni100 sensor datasheet abstract
datasheet frame
Abstract: PRetrans 5131 2-WIRE PROGRAMMABLE TRANSMITTER Input for RTD, TC, mV, linear resistance, mA , Conversion of current signals from supplied transmitters to 2-wire 4.20 mA signals. · Amplification of mV , norm DIN 43760. Automatic cable compensation at a 3 or 4-wire connection. At a 2-wire connection, the , : _ Specify range : _ RTD connection: CJC: 2-wire, no compens. 2-wire, fixed line res. , connection: 2-wire, no compensation: 2-wire, fixed line resistance 3-wire compensation: 4-wire ... Original
datasheet

4 pages,
289.65 Kb

pr-electronics PT100 3 wire connected diagram PT100 DIN pt100 LR DIN 43710 current transmitter 4.20 mA 5131Y LIMIT SWITCH namur 43 DIN EN 50014 STANDARD for thermocouple e988 namur NE 43 NE43 5131B datasheet abstract
datasheet frame
Abstract: ±0.2°C Shortest span Sensor lead resistance - for 3-, 4-wire connection - for 2-wire connection , Programmable 2-wire transmitter for use with resistance thermometers and thermocouples, for fitting into terminal head Form B to DIN 43 729 Brief description The 2-wire transmitter uses a resistance , resistance per conductor Resistance thermometer in 2-wire circuit 3 6 RL 11 RL = lead , recalibration (fine calibration) - lead resistance for 2-wire circuit 4.00/00383981 If no power supply ... Original
datasheet

5 pages,
243.34 Kb

Thermocouple type PT100 namur NE 43 MoRe5-MoRe41 PT100 temperature sensor JUMO datasheet abstract
datasheet frame
Abstract: 3-/4-wire 2-wire Ambient temperature error Pt100 EN 60751 2-wire / 3-wire / 4-wire -200 to +850°C 0.05% 0.4% 50ppm/°C Pt500 EN 60751 2-wire / 3-wire / 4-wire -200 , +850°C 0.1% 0.8% 50ppm/°C Pt100 GOST 6651-94 2-wire / 3-wire / 4-wire -200 to , logic outputs, and a supply voltage for a 2-wire transmitter. Three expansion slots can be filled with , outputs Supply for 2-wire transmitter Option 1 k Configurable process display text (max. ... Original
datasheet

7 pages,
225.3 Kb

W3Re-W26Re cu100 jumo TTL RS232 converter KTY11-6 PT100 temperature sensor JUMO PT1000 RTD probe pt1000 type thermocouple sensor transmitter pt100 jumo RTD PT100 jumo USB TTL "7 segment display" relay 230v Cu50 RTD 315-697-JUMO 1-800-554-JUMO 315-697-JUMO abstract
datasheet frame
Abstract: 3-/4-wire 2-wire Ambient temperature error Pt100 EN 60751 2-wire / 3-wire / 4-wire -200 to +850°C 0.05% 0.4% 50ppm/°C Pt500 EN 60751 2-wire / 3-wire / 4-wire -200 , +850°C 0.1% 0.8% 50ppm/°C Pt100 GOST 6651-94 2-wire / 3-wire / 4-wire -200 to , logic outputs, and a supply voltage for a 2-wire transmitter. Three expansion slots can be filled with , outputs Supply for 2-wire transmitter Option 1 k Configurable process display text (max. ... Original
datasheet

7 pages,
230.37 Kb

PT1000 JUMO jumo pt500 PT500 JUMO PT500 RTD PT1000 temperature sensor PT1000 table pt100 temperature probe circuit diagram pt100 temperature display jumo 5 digit 7 segment display PT500 temperature sensor PT1000 temperature sensor JUMO converter modbus to profibus chromel-copel 315-697-JUMO 1-800-554-JUMO 315-697-JUMO abstract
datasheet frame
Abstract: 2-wire supply > 16 V FM-approved for installation in Div. 2 Output for current and voltage Universal , movements with attached potentiometer. · Power supply and signal isolator for 2-wire transmitters. 41 , : 2-wire supply (terminal 44.43) . 25.16 VDC / 0.20 mA Max. wire size , Application: · Linearised, electronic temperature measurement with RTD or TC sensor. RTD and lin.R TC , characteristics: · Communications interface for modification of operational parameters in 4114. · LCD ... Original
datasheet

2 pages,
95.29 Kb

Pt100 transmitter 4.20 mA namur NE 21 e988 60584 DIN 43710 IEC60751 IEC-60751 datasheet abstract
datasheet frame
Abstract: , allowing the designer to implement a 2-wire interface for distances up to 2 meters. References 1. PTS , to lead wire resistance. OUT1 and OUT2 both source a 200uA current. The 2-wire technique of Figure , while lowering its self-heating error, it can be connected to the ADC directly, even in a 2-wire , drops in the wires of a 2-wire sensing technique can produce errors at the ADC. To estimate the errors in a 2-wire circuit, multiply the total length of the extension leads times the resistance per foot ... Original
datasheet

9 pages,
286.19 Kb

T100 T1000 PT1000 temperature sensor circuit maxim pt100 interface PT1000 385 pt1000 adc PT100 temperature sensor JUMO pt100 smd 1206 PT100 standard IEC 60751 accuracy pts1206 free IR circuit diagram pt100 multiplexer pt1000 voltage to temperature formula PT100 PT1000 PT100 abstract
datasheet frame
Abstract: Zweidraht-Messumformer Programmable 2-wire transmitter B 95.6550 Betriebsanleitung Operating Instructions 10.02 , JdTRANS T01 Programmable 2-wire transmitter B 95.6550 Operating Instructions Type designation JUMO dTRANS T01 (1) Basic version 956550 programmable 2-wire transmitter 956552 programmable 2-wire transmitter installed in rail-mounting housing1 xx xx (2) Input (programmable) 888 , ­6 Resistance thermometer in 2-wire circuit 3 6 Resistance thermometer in 3-wire ... Original
datasheet

36 pages,
3129.87 Kb

transmitter pt100 jumo testo rs232 cable sonde type k sonde pt100 PT100 DIN jumo TTL RS232 converter CAPTEUR PT100 F-57075 datasheet abstract
datasheet frame

Extended Electronics Archive (Experimental)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
input PT100 (RTD) The IE3202 IE3202 IE3202 IE3202 analog input module allows resistance sensors to be PT100 sensors in 4-wire connection. Sensor malfunctions such as broken wires are indicated by error  Beckhoff IE3202 IE3202 IE3202 IE3202 | 4-channel analog input PT100 (RTD 3 | GNDs 4 | GND P 4-wire 3-wire 2-wire Power supply feed Power supply down PT100, PT200 PT200 PT200 PT200, PT500 PT500 PT500 PT500, PT1000 PT1000 PT1000 PT1000, Ni100, Ni120, Ni1000 resistance measurement (e.g. potentiometer
www.datasheetarchive.com/files/beckhoff/catalog/english/fieldbus_box/ie3202.htm
Beckhoff 10/11/2009 9.78 Kb HTM ie3202.htm
4-wire 3-wire 2-wire EP3204-0002 EP3204-0002 EP3204-0002 EP3204-0002 | 4-channel analog input PT100 (RTD) The EP3204 EP3204 EP3204 EP3204 EtherCAT Box with analog inputs allows resistance sensors to be connected directly. The ohms. The module's standard settings are: resolution 0.1°C in the temperature range of PT100 sensors in Sensor types PT100, PT200 PT200 PT200 PT200, PT500 PT500 PT500 PT500, PT1000 PT1000 PT1000 PT1000, Ni100, Ni120, Ni1000 resistance measurement (e  Beckhoff EP3204 EP3204 EP3204 EP3204 | 4-channel analog input PT100 (RTD
www.datasheetarchive.com/files/beckhoff/catalog/english/fieldbus_box/ep3204.htm
Beckhoff 10/11/2009 10.56 Kb HTM ep3204.htm
the Ex area into a 4.20 mA signal. 2-wire PT100 sensors are connected to the "+" and "-" connections on the PI-EX-TB base terminal block. For applications with 3-wire PT100 sensors, the PROCESS INTERFACE Temperature Ex Temperature Measuring Transducer PROCESS INTERFACE Temperature Ex Temperature Measuring Transducer Intrinsically transducer converts signals from sensors in the Ex area with linear mV or resistance curves into 4.20 m
www.datasheetarchive.com/files/phoenix-contact/linien/ide060302.html
Phoenix Contact 21/02/2003 4.15 Kb HTML ide060302.html
: Thermocouples: ±0.2°C ±1/2 lsd; RTD: Pt100 ±0.2°C ±1/2 lsd 10 ohm Cu ±1°C : Thermocouples: J, K, T, E, R, S, B, C, N, and J-DIN; RTD: Pt100, 500, 1000 with 385 or 0.05°C/°C • Output: RS-485 RS-485 RS-485 RS-485, 2-Wire (half duplex 0.05°C/°C • Output: RS-485 RS-485 RS-485 RS-485, 2-Wire (half duplex : Thermocouples: J, K, T; Pt100 RTD: a = 0.00385 • Display: 4
www.datasheetarchive.com/files/omega/newport/products/temprtur/index.htm
Omega 20/06/2000 74.1 Kb HTM index.htm
, and a sensor or a transducer (thermocouple, strain gauge, PT100 RTD 1 , etc , which change with the cable's length. Current transmission also allows a single 2-wire cable -distance transmission without amplitude loss Detection of offline sensors, broken transmission lines, and other failures Inexpensive 2-wire cables Lower EMI sensitivity linear in a range, including 273°K (0°C). PT100, for example, is a member of an RTD family
www.datasheetarchive.com/files/maxim/0012/view_032.htm
Maxim 04/04/2001 47.56 Kb HTM view_032.htm
/Prediction TC670 TC670 TC670 TC670 TC650/1/2/3 TC650/1/2/3 TC650/1/2/3 TC650/1/2/3 integrated temp sensor TC654/55/64/65 TC654/55/64/65 TC654/55/64/65 TC654/55/64/65 2-wire interface TC642/6/7/8/9B TC642/6/7/8/9B TC642/6/7/8/9B TC642/6/7/8/9B fan auto . Sensor Demo Board MCP355X MCP355X MCP355X MCP355X Sensor App. Dev Board MCP4XXX Daughter Board Interface Online Info P/N: TC642EV TC642EV TC642EV TC642EV This presentation gives a brief overview of all Microchip Technology Analog & Interface products
www.datasheetarchive.com/files/microchip/analog/treelink/aipd-treelink_10-06.pps
Microchip 07/11/2006 20959.5 Kb PPS aipd-treelink_10-06.pps
-ended, 16 bit EL3201 EL3201 EL3201 EL3201 | ES3201 ES3201 ES3201 ES3201 EtherCAT Terminal, 1-channel input PT100 (RTD) for resistance sensors, 16 bit EL3202 EL3202 EL3202 EL3202 | ES3202 ES3202 ES3202 ES3202 EtherCAT Terminal, 2-channel input PT100 (RTD) for resistance sensors, 16 bit EL3204 EL3204 EL3204 EL3204 | ES3204 ES3204 ES3204 ES3204 EtherCAT Terminal, 4-channel input PT100 (RTD) for resistance sensors, 16 bit EL3311 EL3311 EL3311 EL3311 Ether digital input 24 V DC, 8 x 24 V DC, 3.0 ms filter, 2-wire connection EL1809 EL1809 EL1809 EL1809 EtherCAT Terminal 01 I/O interface card for Servo Drive AX2000 AX2000 AX2000 AX2000 AX2090-MD20 AX2090-MD20 AX2090-MD20 AX2090-MD20 Motor choke for Servo Drive AX2
www.datasheetarchive.com/files/beckhoff/catalog/english/beckhoff/pindex.htm
Beckhoff 10/11/2009 272.66 Kb HTM pindex.htm
sensitivity at room temperature. Compared to 0.4 W /°C for a Pt100, this is quite high. Upper range of measurements, unlike RTDs. 2-wire measurements are adequate. The physical size of thermistors is quite small of the main advantages of IC sensors is that they are easy to interface to. The drawbacks include Sensor Fundamentals Tuesday Aug 25, 10:15-11:15 a.m. and 11:30-12:30 p.m. Lavaca (6B) Bakul Damle, Evan Hubbard, Mark Whittington Hardware Engineers Sensor Fundamentals Bakul Damle - RTDs
www.datasheetarchive.com/download/11007971-571026ZC/daq1b.ppt
National Instruments 15/07/1998 1140 Kb PPT daq1b.ppt