500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
PT1000-2050-VM API Delevan General Purpose Inductor, 1000uH, 15%, 1 Element, Iron-Core, RADIAL LEADED visit Digikey Buy
PT100R-1260-VM API Delevan General Purpose Inductor, 100uH, 15%, 1 Element, Iron-Core, RADIAL LEADED, ROHS COMPLIANT visit Digikey Buy
PT1000-1750HM API Delevan 1 ELEMENT, 1000uH, POWDERED IRON-CORE, GENERAL PURPOSE INDUCTOR, RADIAL LEADED visit Digikey Buy
PT100R-1100-VM API Delevan General Purpose Inductor, 100uH, 15%, 1 Element, Iron-Core, 9560, RADIAL LEADED, ROHS COMPLIANT visit Digikey Buy
PT100-1000-VM API Delevan General Purpose Inductor, 100uH, 15%, 1 Element, Iron-Core, 9560, RADIAL LEADED visit Digikey Buy
PT1000R-1750-VM API Delevan General Purpose Inductor, 1000uH, 15%, 1 Element, Iron-Core, RADIAL LEADED, ROHS COMPLIANT visit Digikey Buy

pt100 jis

Catalog Datasheet MFG & Type PDF Document Tags

pt100 jis

Abstract: FLUKE 725 724 Fluke 724 - . . . , . / , . 25% 100%. . 24.000 . 24.000 . 24 . 100.00 . 30.000 . - 20.000 .-.10.000. 0 3200 J, K, T, E, R, S, B, L, U, N Ni120; Pt100 (3926); Pt100 (JIS); Pt100, 200, 500, 1000 (385) A M M B M S M M S M S M S M S . . . . , . . . . (18°C - 28
-
Original

CJ1W-PTS52

Abstract: CJ1W-AD04U Configuration CS1W-PTS16 Two resistance thermometer inputs (Pt100 (JIS, IEC), JPt100, Pt50, or Ni508 , Pt100 (JIS, IEC), JPt100, Pt50, Ni508.4 Sensor type, input range, and scaling to industrial units are , Configuration CJ1W-PTS52 Four platinum resistance thermometer inputs (Pt100 (JIS, IEC), JPt100) 20 , resistance Warmup time Conversion period 4 Pt100 (JIS, IEC), JPt100 Sensor type, input range, and scaling to , (Isolated-type inputs for each input Resistance Thermometer Input Units) Resistance thermometer: Pt100, JPt100
OMRON
Original
CJ1W-PH41U CJ1W-AD04U CJ1W-PTS51 CJ1W-PDC15 CJ1W-PTS16 pt50 jis omron f300 CJ1W-PTS/PDC/PH41U/AD04U PH41U AD04U

D20400

Abstract: CJ1W-PTS52 . 1 0 System Configuration CS1W-PTS16 Two resistance thermometer inputs (Pt100 (JIS, IEC , Temperature sensor type Pt100 (JIS, IEC), JPt100, Pt50, Ni508.4 Sensor type, input range, and scaling to , Configuration CJ1W-PTS52 Four platinum resistance thermometer inputs (Pt100 (JIS, IEC), JPt100) 20 , Temperature sensor type Pt100 (JIS, IEC), JPt100 Sensor type, input range, and scaling to industrial units , : Pt100, JPt100, Pt50, Ni508.4 Conversion speed: 10 ms/ 2 inputs, Resolution: 1/64,000
OMRON
Original
D20400 CJ1W-PTS d2059 power supply circuit diagram omron sysmac c200h pt100 jis Ni508.4

7MF4997-1DB

Abstract: Siemens PT100 temperature sensor RTD · DIN IEC 751 Pt100 (DIN IEC 751) · Acc. to JIS C 1604-81 or PC/laptop with SIMATIC PDM , Pt100 (JIS C1604-81) · Acc. to DIN 43760 Temperature-linear, resistance-linear or , specifications") Pt100 (DIN IEC) Pt100 (JIS) Ni100 (DIN) -200 . +850 °C -200 . +649 °C -60 . +250 , circuit operation) J03 Y60 Failure signal Pt100 (DIN IEC) Pt100 (JIS) -200 . +850 °C -200 , (1.1) 100 1.0 (1.8) 100 1.0 (1.8) DIN IEC 751 · Pt10 · Pt50 · Pt100 · Pt200 · Pt500
-
Original
7MF4997-1DB Siemens PT100 temperature sensor RTD siemens a5e00 7MF4997-1DA 7MF4997-1AB 7MF4997-1AH
Abstract: Mode Accuracy in °C 4-wire input 2-wire/3-wire input Pt10 385 Pt50 385 Pt100 385 Pt200 385 Pt500 385 Pt1000 385 Pt100 JIS Range Output - 200 to , C.A 1621 C.A 1623 C.A 1631 Measurement and simulation of all your process and temperature signals Calibrators C.A 1621 Calibrator for J, K, T, E, R, S, B and N thermocouple probes C.A 1623 Calibrator for Pt 10, Pt 50, Pt 100, Pt 200, Pt 500, Pt 1000 and Pt 100(JIS) platinum probes COSINUS Messtechnik
Original
P01654621 P01654623 P01654402 P01103057

circuit diagram of pid controller

Abstract: motor PT100 connected diagram to be the same one. 1) Input Specifications Accuracy RTD (Pt100, IEC), (Pt100, JIS) (@ 25 , 95 Input Specifications (cont.) Compensation RTD TC Input RTD ranges Probe: Pt100 (IEC) Probe: Pt100 (JIS) Input TC ranges Probe: TC-B Probe: TC-E Probe: TC-J Probe: TC-K Probe , : TC inputs: B, E, J, K, L, N, R, S, T, U RTD inputs: Pt100 C: 0/4 to 20 mADC V: 0/1 to 5 VDC W
-
Original
PDI95A circuit diagram of pid controller motor PT100 connected diagram PDI 95 PID controller control valve RS485

manual omron E5CN-Q2MTc-500

Abstract: SYS-CONFIG V2.0 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 E5AN E5AN , -1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 E5EN E5EN Specifications J RATINGS Supply , -1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100 , JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 E5GN E5GN Specifications , 600 500 400 300 200 100 0 ­100 ­200 Platinum resistance thermometer Pt100 JPt100 Note: Lightly
-
Original
E5AN-Q3HMTC-500 E5AN-C3MTC-500 GCTC13 manual omron E5CN-Q2MTc-500 SYS-CONFIG V2.0 E5CN-R2MTC-500 E5EN-R3MTC-500 UL3121-1 E5EN-C3MTC-500 E5AN-R3MTC-500 AC100-240 E5AN-R3HMTC-500 E5AN-Q3MTC-500

jPT100

Abstract: E5GN-Q1TC manual , E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 0 9 10 ­100 ­200 0 0 0 , 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 ­100 ­200 Pt100 , Platinum resistance thermometer: Pt100, JPt100 Non-contact temperature sensor: 10 to 70_C, 60 to 120
OMRON
Original
jPT100 E5GN-Q1TC manual rtd pt100 sensor JIS C1604 JIS C1604-1989 E5GN-Q1TC AC100-240 7 segment digital display AC/DC24 1-800-55-OMRON

OMRON E5CN-R2MTC-500

Abstract: E5CN-Q2MTC-500 , J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate default settings , 700 600 500 400 300 200 100 0 ­100 ­200 Pt100 850 500.0 500.0 100.0 1 , 4 VA/3 W Thermocouple: K, J, T, E, L, U, N, R, S, B Platinum resistance thermometer: Pt100
-
Original
E5CN-QMP-500 E5CN-R2MP-500 E5CN-Q2MTC-500 E5CN-Q2MP-500 E5CN-RMTC-500 E5CN-RMP-500 OMRON E5CN-R2MTC-500 omron e5cn E53-COV10

E5GN-Q1TC manual

Abstract: DIN 43710-1985 , E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate default settings. 0 , 300 200 100 0 ­100 ­200 Pt100 850 500.0 500.0 100.0 1 0.0 ­199.9 0 , resistance thermometer: Pt100, JPt100 Non-contact temperature sensor: 10 to 70_C, 60 to 120_C, 115
-
Original
DIN 43710-1985 PT100 Platinum Resistance Thermometer C1602 E5GN-Q1TC pt100 sensor JIS C1604 range M type A

pt100 jis

Abstract: motor PT100 connected diagram (Pt100, IEC), (Pt100, JIS) (@ 25°C ± 5°C, R.H. 60%) TC (B, E, J, K, L, N, R, S, T, U, 0 to 50 mV) (@ , : Pt100 (IEC) Probe: Pt100 (JIS) Input TC ranges Probe: TC-B Probe: TC-E Probe: TC-J Probe , , L, N, R, S, T, U 50/60 Hz, RTD inputs: Pt100 24 VDC -10% +10% 1) C: 0/4 to 20 mADC with
Carlo Gavazzi
Original
EN 60730-1 extruder PID code for DC Motor control PT100 IEC B PDI45A

E5GN-Q1TC manual

Abstract: PT100 Platinum Resistance Thermometer : JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate default settings. Note: The ES1A , 200 100 0 ­100 ­200 Pt100 850 500.0 500.0 100.0 1 0.0 ­199.9 0 100.0 , , E, L, U, N, R, S, B 4 VA/2.5 W Platinum resistance thermometer: Pt100, JPt100
-
Original
ES1A OMRON relay k115

dehumidifier

Abstract: PT100 omron SENSOR the Sensor for an extended period at a humidity of 90% or more. 4. Pt100 (JIS C 1604-1989) is used for the measuring elements. Set Pt100 for input sensor type of the Temperature Controller , output Pt100: 3 wire (See note 4.) Class JIS class B 4 dia. Communications cable 5 m
OMRON
Original
dehumidifier PT100 omron SENSOR omron pt100 Pt100 3 wire resistive Humidity Sensor ES2-THB

PT100 omron SENSOR

Abstract: omron pt100 . 3. Do not use or store the Sensor for an extended period at a humidity of 90% or more. 4. Pt100 (JIS C 1604-1989) is used for the measuring elements. Set Pt100 for input sensor type of the , resistance thermometer Temperature detection range 0 to 55 C Temperature output Pt100: 3 wire
OMRON
Original
omron temperature sensor pt100 PT100 omron PT100 omron temperature SENSOR Pt 100 sensor connection MAX HEATER ES2T

E5CN-R2MP-500

Abstract: E5CN-R2MTC-500 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 , 1100 1000 900 800 700 600 500 400 300 200 100 0 ­100 ­200 Pt100 850 500.0 , , U, N, R, S, B 4 VA/3 W Platinum resistance thermometer: Pt100, JPt100 Non-contact
-
Original
E5CN-QMTC-500 E5CN-CMTC-500 E5CN-CMP-500 E5CN-C2MP-500 E53-CNHB E53-CNB E5CN-c2Mtc-500 E53-CNH03 E5Cn E5CN-C2MTC-500

OMRON E5CN-R2MTC-500

Abstract: E5CN-R2MTC-500 17 3 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 0 9 10 ­100 ­200 1 0 0 ­100 60 L K10 to , 1100 1000 900 800 700 600 500 400 300 200 100 0 ­100 ­200 Pt100 JPt100 Note , Platinum resistance thermometer: Pt100, JPt100 Non-contact temperature sensor: 10 to 70_C, 60 to 120
-
Original
PT100 temperature sensor data sheet omron ct E54-CT1 E54-CT1 rtd pt100 sensor PT100 4 wire temperature sensor E53-CN03

E5CN-R2MTC-500

Abstract: E5CN-R2MP-500 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 , 1100 1000 900 800 700 600 500 400 300 200 100 0 ­100 ­200 Pt100 850 500.0 , , E, L, U, N, R, S, B 4 VA/3 W Platinum resistance thermometer: Pt100, JPt100 Non-contact
-
Original
E5CN-R2

E54-CT1

Abstract: E5AN-Q3HMTC-500 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 , , T, E, L, U, N, R, S, B Pt100, JPt100 10 to 70°C, 60 to 120°C, 115 to 165°C, 160 to 260°C 0 to 50 , 600 500 400 300 200 100 0 -100 -200 Set value Pt100 JPt100 850 500.0 500.0
OMRON
Original
E5AN-Q3HMP-500 E5AN type s thermocouple omron temperature controller e5cn digital thermometer using pt100 E5AN-R3HMP-500 E5AN-Q3MP-500 E5AN-C3MP-500 RS-485 RS-232C

omron e5cn

Abstract: E5CN-R2T input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded , 24 VAC, 50/60 Hz/24 VDC 3 VA/2 W K, J, T, E, L, U, N, R, S, B Pt100, JPt100 K10 to 70°C, K60 to , 600 500 400 300 200 100 0 -100 -200 Set value Pt100 JPt100 850 500.0 500.0
OMRON
Original
P3GA-11 E5CN-R2T E5cN-QTC E5CN-R1TCU PT100 ma output E5CN-R2TC e5cn circuit diagram with relay P2CF-11 H109-E1-02 75-344-7080/F
Abstract: : ANSI, IEC 584, DIN IEC 584, JIS C 1602-1981; Type N: Nicrosil-Nisil, IEC 584, DIN IEC 584; Type C W5%-R/W-26%; J DIN, T DIN: DIN 43760 * Only available on RD260A models and RD266-RTD. Pt100: JIS C 1604-1989, JIS C 1606-1989, IEC 751, DIN IEC 751, JPt100 JIS C 1604-1981, JIS C 1606-1989 S-32 S 3 , Pt100 JPt100 Memory Backup: Lithium battery to preserve setup parameters Life: approx. 10 years Omega Engineering
Original
RD260 RS-422A RD261 RD262 RD263 RD263A-A2-S4
Showing first 20 results.