500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LM134H-6 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN visit Linear Technology - Now Part of Analog Devices
LM134H-3 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN visit Linear Technology - Now Part of Analog Devices
LTC2997HDCB#TRMPBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: High visit Linear Technology - Now Part of Analog Devices
LTC2997IDCB#TRPBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2997CDCB#TRPBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: Commercial visit Linear Technology - Now Part of Analog Devices
LTC2997IDCB#PBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: Industrial visit Linear Technology - Now Part of Analog Devices

pt 100 temperature sensor RTD abb

Catalog Datasheet MFG & Type PDF Document Tags

pt100 rtd rosemount

Abstract: pt 100 temperature sensor RTD abb 3 Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD , programmable, Pt 100 (RTD), thermocouples, electrical isolation Level 0: Information Input ­ , 100 (RTD), thermocouples, electrical isolation 10/11 8.54 EN Technical data Sensor short-circuit < 5 (for RTD) Output Sensor break (temperature/resistance measurement 2, 3, 4 wire , TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11 8.54 EN
ABB Automation
Original

SENSORS TEMPERATURE Pt-100-DIN 43760

Abstract: PTB 01 ATEX 2035 Rail mounted Temperature Transmitter TS102/TS102-Ex programmable, Pt 100 (RTD), thermocouples , programmable, Pt 100 (RTD), thermocouples, electrical isolation Input ­ Resistance thermometer (2-, 3 , TS102/TS102-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11-8.50 EN , . Influences Influence effect of temperature acc. to IEC 68-2-2 Pt 100/resistance measurement3) ME , programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11-8.50 EN Connection diagram 11 +
ABB Automation
Original

Pt 100 RTD Siemens

Abstract: Thermocouple Type L diagnostics Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS PA, Pt 100 (RTD), Thermocouples , Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS PA, Pt 100 (RTD), Thermocouples, 1 or 2 , mm2 3 Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS PA, Pt 100 (RTD , Temperature 2 + Status Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS PA, Pt 100 (RTD , PA, Pt 100 (RTD), Thermocouples, 1 or 2 independent channels Input ­ Resistance thermometer (2
ABB Automation
Original

Resistance characteristic Ni1000

Abstract: ABB Pt100 3 wire Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD , disabled 3 Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD , Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD , * * * * * Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD , FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent channels Input ­ Resistance
ABB Automation
Original

ABB Pt100 3 wire

Abstract: pt100 temperature sensor circuit diagram Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent , ) Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples , FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent channels Input ­ Resistance , time < 0.5 s Influence of ambient temperature Pt 100 resistance measurement 0.500 W 0.4000 , 61000-4-6 10 V 3 Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus H1, Pt 100
ABB Automation
Original

abb ts202

Abstract: SENSORS TEMPERATURE Pt-100-DIN 43760 Field mounted Temperature Transmitter TS202/TS202-Ex programmable, Pt 100 (RTD), thermocouples , ) 7 Field mounted Temperature Transmitter TS202/TS202-Ex programmable, Pt 100 (RTD , programmable, Pt 100 (RTD), thermocouples, electrical isolation Input ­ Resistance thermometer (2-, 3 , Transmitter TS202/TS202-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11-8.62 EN , Transmitter TS202/TS202-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation Power supply
ABB Automation
Original

rosemount 1144

Abstract: rosemount pt 100 rtd No. 7 Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD , HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Level 0: Information , Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical , shock Influences Influence of ambient temperature Pt 100/resistance measurement2) ME , , Pt 100 (RTD), thermocouples, electrical isolation 10/11 8.64 EN Displays (option) Digital
ABB Automation
Original

th202

Abstract: ABB Hart Temperature Transmitter TH202 Temperature Transmitter TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation , Field mounted Temperature Transmitter TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples , programmable, Pt 100 (RTD), thermocouples, electrical isolation Input ­ Resistance thermometer (2, 3, 4 , 100 (RTD), thermocouples, electrical isolation 10/11-8.64 EN Technical data Sensor short-circuit < 5 (for RTD) Output Sensor break (temperature/resistance measurement 2, 3, 4 wire
ABB Automation
Original

V11518

Abstract: PT-100 RTD 4 wire sensor - rosemount diagnostics Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, Pt 100 (RTD , No. 7 Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, Pt 100 (RTD , distance) Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, Pt 100 (RTD , Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical , programmable, Pt 100 (RTD), thermocouples, electrical isolation Level 0: Information Input ­
ABB Automation
Original

th02-ex

Abstract: transmitter TH02-Ex Temperature Transmitter TH02/TH02-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation , ) 3 Head mounted Temperature Transmitter TH02/TH02-Ex HART programmable, Pt 100 (RTD , mounted Temperature Transmitter TH02/TH02-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical , mounted Temperature Transmitter TH02/TH02-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical , , Pt 100 (RTD), thermocouples, electrical isolation Input ­ Resistance thermometer (2-, 3-, 4
ABB Automation
Original

contrans ts 11

Abstract: pt 100 temperature sensor RTD abb Temperature Transmitter TS02/TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation Power , Temperature Transmitter TS02/TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation , Temperature Transmitter TS02/TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation 10 , Head mounted Temperature Transmitter TS02/TS02-Ex programmable, Pt 100 (RTD), thermocouples , programmable, Pt 100 (RTD), thermocouples, electrical isolation Input ­ Resistance thermometer (2-, 3
ABB Automation
Original

pt100 atex

Abstract: AGLF Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 , ) Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD , Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 , Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent channels Input ­ Resistance thermometer , V/m EN 61000-4-6 10 V Influences Influence of ambient temperature acc. to IEC 68-2-2 Pt 100
ABB Automation
Original

PT-100 RTD 3 wire transmitter

Abstract: pt 100 temperature sensor RTD abb Head-mounted temperature transmitter, programmable via push-button, Pt 100 2/3-wire (RTD) 10/11-8.16 EN , TS 04 Head-mounted temperature transmitter, programmable via push-button, Pt 100 2/3-wire (RTD) 10/11-8.16 EN s Input ­ Pt 100 resistance thermometer (2-wire or 3-wire) s Output ­ 2 , transmitter converts the temperature-dependent resistance value of a connected Pt 100 sensor directly into a , , programmable via push-button, Pt 100 2/3-wire (RTD) 10/11-8.16 EN Technical data Output
ABB Automation
Original

ANSI MC96.1

Abstract: difference between 304, 316 and 316L Temperature Measurement Products Heavy Duty Spring Loaded Sensor - Series V10186 Model Number V10186- Sensor 1 x Pt 100, 2-wire 1 x Pt 100, 3-wire 1 x Pt 100, 4-wire 2 x Pt 100, 3-wire 1 x Type K 1 x , Duty Spring Loaded Sensor Assemby with Transmitter Series V10186 Temperature Measurement Products , Threaded Without Thermowell Temperature Measurement Products Heavy Duty Spring Loaded Sensor - , specification. 3 Temperature Measurement Products Heavy Duty Spring Loaded Sensor - Series V10186
ABB Automation
Original
D-TS-V10186 ANSI MC96.1 difference between 304, 316 and 316L 60584 Inconel 600 pt 100 temperature sensor RTD abb BUZH, Aluminum

potenciometro 500

Abstract: potentiometre PT 10 thermometer for PT 10, PT 100, PT 1000 Signal d'entrée: G(+) - H(-) Capteur de température résistif pour , Convertisseur universel pour signaux de température, gamme CC ABB Stotz-Kontakt GmbH Hauptstr. 14-16 78132 , .3 on on off off SW2.6 PT 10 PT 100 PT 1000 keine Funktion SW2.4 Auswahl der Linearisierung PT 10 T < 650 °C off on off PT 10 T > 650 °C off on off PT 100 PT 1000 off off , Eingangssignal: G - J - H Widerstandsthermometer für PT 10, PT 100, PT 1000 Ausgangssignale: A(+) - C(-
ABB Automation
Original
potenciometro 500 potentiometre PT 10 potenciometro termoresistor sensor resistivo pt 100 to92 sensor resistivo PT 1000 SOT223

653sy

Abstract: ABB 600T transmitters are supplied as follows : Standard configuration - Sensor type (RTD): IEC 751 Pt 100 3-wire ( = , external CJC with Ni 100 or Pt 100 : Tamb from -40°C to +135°C. Temperature coefficient · type E, J, K, L , °C or ± 0.1% Pt 50/200/500 : ± 0.2°C or ± 0.1% Ni 100 : ± 0.2°C or ± 0.1% Sensor current nom. 0.2 mA , : Linear with temperature - Broken sensor drive : Upscale Optional LCD meter : 0 to 100% linear , Type W3 Thermocouple Type W5 IEC 751 / DIN43760 ( = 0.00385) Resistance thermometer Pt 100 2
-
Original
653sy ABB 600T ABB KENT-TAYLOR transmitter ABB 653s IEC 584-1 PT100-1000 RTD AN0239 SS/653S

ABB KENT-TAYLOR transmitter

Abstract: pt 100 temperature sensor RTD abb Input resistance 10 M RTD INPUT Basic accuracy ± 0.2°C Sensor current nom. 0.2 mA Temperature coefficient · span 100°C : ± 0.01%/°C Effect of sensor cable resistance (3/4 , °F) Resistance thermometer Pt 100 2 wires Resistance thermometer Pt 100 3 wires Resistance thermometer Pt 100 4 , with true temperature for THC and RTD. Optional output meter LCD : 3 1/2 digit (±1999 counts) with , ± 0.1% Temperature coefficient ± 0.01 / °C or ± 0.01% / °C Sensor current nom. 0.2 mA Effect
-
Original
calibration certificate of k type thermocouple Thermocouple Type L ABB thermocouple calibration procedure for thermocouple PT-100 ABB Thermocouple Type B SS/653T

IEC 584-1

Abstract: Thermocouple Type t °C Sensor current 0.2 mA to 0.4 mA Temperature coefficient span , Sensor current nom. 0.2 mA Temperature coefficient · span 100°C : ± 0.01 , (CJC) : < ± 1.0°C · external CJC with Ni 100 or Pt 100 : Tamb from -40°C to +135°C. Temperature , 0.1°C or ± 0.1% Pt 50/200/500 : ± 0.2°C or ± 0.1% Ni 100 : ± 0.2°C or ± 0.1% Sensor current nom , digital communications. Programmable parameters include temperature range, response time and sensor
-
Original
Thermocouple Type t 600t SMART Differential Pressure Transmitter abb PT100 IEC 751 BS4937 600t SMART temperature Transmitter abb Thermocouple Type K SS/652

267CS

Abstract: abb temperature Transmitter (160 " H2O) 100 bar (1500 psi) · Process Temperature Measurement (Pt 100 RTD) ± 0.3º C (0.54º , ) Ambient Temperature Effect DP Sensor Between the temperature of -10ºC to +60ºC (14ºF to +140ºF , Data Sheet 2101155-AI XMV Multi-Variable Transmitter Overview INTRODUCTION The ABB XMV (267CS/269CS) measures Static Pressure, Differential Pressure, and Process Temperature in a vapor or , current draw is approximately 11.7 mA per XMV. This unit is designed to operate with the ABB Totalflow
ABB Automation
Original
267CS 269CS abb temperature Transmitter XMV 269Cs wiring with transmitter 269cs abb pt pressure transmitter flow orifice

transformador

Abstract: potenciometro ajustable 2k 7 - PA + 7 PA 8 9 A00187 Abb. 4 Sensor- u , A00190 + - Abb. 7 13 1 x RTD, 4-Leiterschaltung und Thermoelement (Sensorbackup / Redundanz , D ia ia ia J A B C A00126 Abb. 11 A Sensor C Speisetrenner [EEx ia] B , Abb. 12 A Sensor C Speisetrenner [EEx ib] B Messumformer TTF350 D HMI-Schnittstelle für , A00128 Abb. 13 A Sensor C Speisetrenner [EEx ib] B Messumformer TTF350 D HMI-Schnittstelle
ABB Automation
Original
transformador potenciometro ajustable 2k TTH300 POTENCIOMETRO 2k NORMAS ATEX PARA CONTROL DE PROCESOS Carimbo CI/TTF350-X1 3KXT221002R4493
Showing first 20 results.