NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: range Packing unit Packaging unit bridge-type rectifier with protective circuit (varistor) GDME GB1 831 832-001 DIN EN 175 301-803-A A bridge-type rectifier varistor AC/DC 250 V 2 A (SEV ... | Original |
1 pages, |
AC-DC RECTIFIER SUPPRESSOR 301-803-A 831 832-001 301-803A controlled bridge rectifier en 175301-803 protective circuit varistor din en 175 301-803-A DIN 43650 varistor application Varistor HIRSCHMANN datasheet abstract |
| Abstract: Schutzbeschaltung (Varistor) und Funktionsanzeige (LED) Bridge-type rectifier with protective circuit (varistor) and function indicator (LED) Pont redresseur avec circuit de protection (varistance) et affichage des fonctions (DEL) LED Gleichrichter mit Schutzbeschaltung (Varistor) und Funktionsanzeige (LED) rectifier with protective circuit (varistor) and function indicator (LED) redresseur avec circuit de , bridge-type rectifier pont redresseur Varistor varistor varistance für LED für LED pour DEL ED rot LED ... | Original |
1 pages, |
Varistor PONT DIODE diode led 3 mm GDML varistor rectifier 731 531-002 gdml 2011 led rouge 3 mm diode led rouge 3 mm datasheet abstract |
| Abstract: Suitable cables Mounting Material bridge-type rectifier with protective circuit (varistor) GDML 2011 , EN 175 301-803-A black A bridge-type rectifier varistor 6.3 mm x 0.8 mm, 4.8 mm x 0.8 mm UC ... | Original |
2 pages, |
301-803-A SEV 1011 gdml 2011 varistor rectifier GDML datasheet abstract |
| Abstract: bearer material Housing material Environmental conditions bridge-type rectifier with protective circuit (varistor) GDML 2011 GB1 schwarz/black 932 329-100 grey housing, Order no. 932 329-106 2 + PE PG 11 max. 1.5 mm² DIN EN 175 301-803-A black A bridge-type rectifier varistor 6.3 mm x 0.8 ... | Original |
2 pages, |
varistor rectifier SEV 1011 gdml hirschmann 301-803-A datasheet abstract |
| Abstract: rectifier with protective circuit (varistor), gasket (captive) and central screw M3 (stainless steel ... | Original |
2 pages, |
301-803-A 3-mm LED GAN-DMFE7A-AG0200C1-XC607-AD GAN-DMFE7A-AG0200C1-XC607-AD abstract |
| Abstract: ), protective circuit (varistor), gasket (captive) and central screw M3 (stainless steel, Phillips cross-head ... | Original |
2 pages, |
varistor 301 hirschmann GDM 301-803-A 3-mm LED GAN-DLFE7X-AG0200C1-XC607-AD GAN-DLFE7X-AG0200C1-XC607-AD abstract |
| Abstract: bridge-type rectifier with protective circuit (varistor) GDML 2011 GB1 schwarz/black 932 329-100 grey , rectifier varistor 6.3 mm x 0.8 mm, 4.8 mm x 0.8 mm AC/DC 250 V 2 A (SEV 1011 : 1.5 A) AC / 1 A DC ... | Original |
2 pages, |
varistor 739 731 531-002 734-363-001 BRIDGE RECTIFIER 301-803-A GDM 3-21 Hirschmann 6 pin connector AEN 6 controlled bridge rectifier 803 329 734 363-001 GDML varistor 301 datasheet abstract |
| Abstract: bridge-type rectifier with protective circuit (varistor) GDML 2011 GB1 grau/grey 932 329-106 black housing , varistor 6.3 mm x 0.8 mm, 4.8 mm x 0.8 mm AC/DC 250 V 2 A (SEV 1011 : 1.5 A) AC / 1 A DC page 1 of ... | Original |
2 pages, |
varistor rectifier 731 531-002 gdml hirschmann HIRSCHMANN DIN 43650 HIRSCHMANN DIN 43650 3 pe 301-803-A varistor 301 gdml 2011 GDML SEV 1011 datasheet abstract |
| Abstract: (lampe témoin fluorescente) Brückengleichrichter mit Schutzbeschaltung (Varistor) Bridge-type rectifier with protective circuit (varistor) Pont redresseur avec circuit de protection (varistance , lampe témoin fluorescente Brückengleichrichter bridge-type rectifier pont redresseur Varistor varistor varistance Spannungsgleichrichter Voltage rectifier Redressement Schutz vor Spannungsspitzen ... | Original |
1 pages, |
DIN43650-A DIN43650 GDM 3011 varistance DIN43650-A abstract |
| Abstract: mVPP 150 mVPP Operation indicator green LED Output protective circuit varistor ... | Original |
2 pages, |
VDE 0470-1 EMG datasheet Varistor g24 Data Module "Green Led" -NZG/G24/SI -NZG/G24/SI abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| integrated high-quality protective circuit limits surge voltages both between the active cables "L" and "N", and between the protective conductor " " and the active cables. In all versions, the basic wiring consists of a combination of varistors and gas-filled surge voltage arresters. The varistors may be through the components and an associated temperature rise. The varistors are therefore thermally monitored and isolated from the AC supply before the temperature rise becomes too great. When the varistors are www.datasheetarchive.com/files/phoenix-contact/linien/ide07022.html |
Phoenix Contact | 03/03/2003 | 1.89 Kb | HTML | ide07022.html |
| , for example, in telecontrol engineering or in traffic light systems. The protective circuit contains a thermally monitored varistor in every protective path. A thermal fuse switches off the damaged varistor. At the same time, this is signalized visually by the corresponding LED on the front of the protective Pluggable Surge Voltage Protective Cascade for Higher Signal Voltages MCR-PLUGTRAB Pluggable Surge Voltage Protective Cascade for Higher Signal Voltages MCR-PLUGTRAB PT 2x1 VA is a www.datasheetarchive.com/files/phoenix-contact/linien/ide07201.html |
Phoenix Contact | 25/07/2002 | 1.54 Kb | HTML | ide07201.html |
| in traffic light systems. The protective circuit has a thermally monitored varistor in each of the protective paths "1" to "9". Frequent or excessive loads due to powerful transient surge voltages can "age" varistors for physical reasons. Varistors which have "aged" in such a way can be recognized as a result of -PLUS Strips, COMTRAB CT 10-9VA 10-9VA 10-9VA 10-9VA CT 10-9VA- 10-9VA- 10-9VA- 10-9VA-.AC is a pluggable, 9-channel protective device in COMTRAB damaged varistor. At the same time, a visual signal is given via the corresponding LED on the front of the www.datasheetarchive.com/files/phoenix-contact/linien/ide07222.html |
Phoenix Contact | 25/07/2002 | 3.82 Kb | HTML | ide07222.html |
| all switch ranges offering corresponding central plates. The PRT-S/./FM protective connector contains the classic circuit for device protection, consisting of temperature-monitored varistors protective connector, PRT-S-230/FM PRT-S-230/FM PRT-S-230/FM PRT-S-230/FM and the PRT-CD-AD1 outlet box. An overloading caused by surge voltage remotely to a central control system. The protective connector is available with a voltage level of either -free N/C contact. The remote indicator connection terminal blocks and the electric circuit connection www.datasheetarchive.com/files/phoenix-contact/linien/ide07012.html |
Phoenix Contact | 25/07/2002 | 2.36 Kb | HTML | ide07012.html |
| protection adapter SFP 1-10 contains a combined protective circuit for absorbing transient surge voltages and protective circuit for absorbing transient surge voltages and high-frequency interference voltages. COMBITRAB CBT-.SFP-10 SFP-10 SFP-10 SFP-10 has four protected positions. If the protective circuit is overloaded by surge voltages be exchanged. The varistors can be overloaded as a result of too high or too frequent loads consequence, a rise in temperature. The varistors are therefore monitored by a thermal disconnect device. The www.datasheetarchive.com/files/phoenix-contact/linien/ide07101.html |
Phoenix Contact | 25/07/2002 | 5.23 Kb | HTML | ide07101.html |
| . The protective circuit for the power supply consists of a varistor/gas arrester combination with the protection of telecommunications systems and termination devices. The protective circuit for the circuit in the event of an overload. WESTERNTRAB WT-RJ 45. are outlet boxes for surface and interfaces of data termination devices. DATATRAB D-TR1/ISDN-A/RJ45-BB D-TR1/ISDN-A/RJ45-BB D-TR1/ISDN-A/RJ45-BB D-TR1/ISDN-A/RJ45-BB is a protective adapter for ISDN protective adapter has a keyed modular jack RJ-45 RJ-45 RJ-45 RJ-45 (RJ-48 RJ-48 RJ-48 RJ-48) female connector as the connection at the input and www.datasheetarchive.com/files/phoenix-contact/linien/ide07601.html |
Phoenix Contact | 03/03/2003 | 8.78 Kb | HTML | ide07601.html |
| -capacity varistor - from the mains when this has become over-loaded due to excessively frequent or high energy surge voltages. An integrated error display on the front side of the protective connector signals the for insulation testing, and secondly, in the case of an overload, the protective connector can be designed for the header can be inserted. The header is coded when the protective connector is plugged in in connection with m.c.b.s and residual-current-operated circuit breakers) for single-phase or multi www.datasheetarchive.com/files/phoenix-contact/linien/ide07005.html |
Phoenix Contact | 16/09/2002 | 4.6 Kb | HTML | ide07005.html |
| control cabinets. The protective circuit in PT 2-PE/S. consists of a combination of varistors and protection level. The protective plug can be plugged into and unplugged from the header at any time, without interrupting operation of the device connected. The protective function of the circuit in the www.datasheetarchive.com/files/phoenix-contact/linien/ide07010.html |
Phoenix Contact | 25/07/2002 | 2.64 Kb | HTML | ide07010.html |
| or combined in a protective circuit because these components differ in terms of derivation and limitation data. Effective Protective Circuit The "effective protective circuit diagram. Surge voltage protection devices should be installed at all "Cable - Protective Circuit" intersections. The protective devices correspond to the nominal data of the relevant circuit type or interface of the device to be protected. This protects the area within the protective circuit, so that a surge www.datasheetarchive.com/files/phoenix-contact/linien/ide07.html |
Phoenix Contact | 07/04/2003 | 14.14 Kb | HTML | ide07.html |
| , there are various designs of surge voltage protection devices. The protective circuit for the analog device protection for the power supply unit consists of a circuit with thermally monitored varistors and protective device may also have trisil diodes with decoupling inductances. It is thus possible to attain a lines and earth. The fine protection elements have fail-safe characteristics, i.e. they short circuit on protect the contacts described in the circuit diagram. This multi-assignment means that the product is fit www.datasheetarchive.com/files/phoenix-contact/linien/ide07604.html |
Phoenix Contact | 23/01/2003 | 9.96 Kb | HTML | ide07604.html |