500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

namur

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: NAMUR DIN EN 60947-5-6 T M 5; 25 mm length /non-flush Part number Wiring diagram (page , .) Electrical and mechanical data for NAMUR inductive sensors M 8 x 1; 32 mm length 1 mm (0.04˝ ) l/â'" NAMUR / B KIB-M05EA/ 001-2 658.1699.009 263/8 l/â'" 1.5 mm (0.06 ˝ ) l/â'" NAMUR / A , functions Model description M 12 x 1; 30 mm length 2 mm (0.08 ˝ ) â'"/l NAMUR / A KIN-M08EA/ 002-2 658.1601.002 263/8 â'"/l 2 mm (0.08 ˝ ) l/â'" NAMUR / A KIB-M12EA/ 002-2 658.1624.004 Altech
Original
KIB-M08EA/ 67/NEMA KIN-M12EA/ KIB-M18EA/ KIN-M18EA/ KIB-M30EA/
Abstract: Sensing distance: 40 mm · Power supply: 8.2 VDC (NAMUR) 24 VDC · Output: Namur (DIN 19234) Transistor , NAMUR DIN 19 234. Sturdy ABS housing. EI 8040 NPOP DJ 40 Type Selection Housing diameter Rated operating dist. (Sn) Ordering no. NAMUR Ordering no. Transistor NPN Make switching , EI 8040 PPOP EI 8040 PPCP 1) For non-flush mounting in metal Specifications NAMUR Rated , (cont.) NAMUR Dependent on amplifier relay 0.9 x Sn Sr 1.1 x Sn 0.8 x Sr Su 1.2 x Sr 1 to 15 Carlo Gavazzi
Original
PPCP SS TRANSISTOR transistor BU 210 npn transistors,pnp transistors transistor BU 110 transistor DJ marking DJ40/EI
Abstract: voltage 5 . 30 VDC, output current 10 mA max. - Ausführung gemäss NAMUR (DIN 19234) - Exécution selon NAMUR (DIN 19234) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft , Mounting (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie , Wiederholgenauigkeit Betriebsspannungsbereich UB (NAMUR - Bedingungen) Betriebsspannungsbereich UB (nicht NAMUR CONTRINEX
Original
DW-AD-305-03 DW-AS-305-03 DW-AS-303-03 DW-AD-303-03 DW-AS-302-03 DW-AS-301-03 02-MDM
Abstract: max. - Ausführung gemäss NAMUR (DIN 19234) - Exécution selon NAMUR (DIN 19234) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der , Normmessplatte Wiederholgenauigkeit Betriebsspannungsbereich UB (NAMUR - Bedingungen CONTRINEX
Original
DW-AD-425-065-400 DW-AD-423-065-400 DW-AD-423-065 DW-AS-423-065-001 namur standard DW-AD-425-065 DW-AD-421-065
Abstract: gemäss NAMUR (DIN 19234) - Exécution selon NAMUR (DIN 19234) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie , Eigenschaften: Einbau Montage Mounting (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in , service UB (NAMUR - Bedingungen) (conditions NAMUR) Betriebsspannungsbereich UB (nicht Tension de -
Original
DW-AS-421-065-001 DW-AD-422-065 DW-AD-424-065 DW-AS-422-065-001 DW-AS-424-065-001 DW AD 621 065
Abstract: VDC, output current 1 / 2,2 mA* - Ausführung gemäss NAMUR (DIN 19234) - Exécution selon NAMUR (DIN 19234) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemein s chaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemein , Mounting (NAMUR = Normen-Arbeitsgemein s chaft für Mess- und Regeltechnik in der chemischen , Wiederholgenauigkeit Reproductibilité Betriebsspannungsbereich UB Tension de service UB (NAMUR - Bedingungen CONTRINEX
Original
DW-AS-405-04 DW-AD-403-04 DW-AD-401-04 40404 DW-AS-403-04 DW-AS-401-04 DW-AD-404-04 DW-AD-405-04 DW-AD-405-04K
Abstract: NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemein s chaft für Mess- und Regeltechnik in der chemischen Industrie) - Exécution selon NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemein s chaft für Mess- und Regeltechnik in der chemischen Industrie) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemein s chaft für Mess- und Regeltechnik in der chemischen Industrie , Wiederholgenauigkeit Betriebsspannungsbereich UB (NAMUR - Bedingungen) Betriebsspannungsbereich UB (nicht NAMUR CONTRINEX
Original
DW-AS-403-M5 DW-AS-404-M5 DW-AD-404-M5 DW-AD-40 DW-AS-402-M5 DW-AS-401-M5 DW-AD-405-M5 DW-AS-405-M5 400-M5
Abstract: Ausführung gemäss NAMUR (DIN 19234) - Exécution selon NAMUR (DIN 19234) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie , Wiederholgenauigkeit Betriebsspannungsbereich UB (NAMUR - Bedingungen) Betriebsspannungsbereich UB (nicht NAMUR CONTRINEX
Original
DW-AD-403-M5 DW-AD-401-M5 DW-AD-402-M5 IEC 61000-4-3 level
Abstract: 5 . 30 VDC, output current 1 / 2,2 mA* - Ausführung gemäss NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der che m ischen Industrie) - Exécution selon NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der che m ischen Industrie) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemein s chaft für Mess , ) Bemessungsschaltabstand sn Hysterese Normmessplatte Wiederholgenauigkeit Betriebsspannungsbereich UB (NAMUR - CONTRINEX
Original
DW-AV-403-C5-276 DW-AD-403-C5 DW-AD-402-C5 DW-AD-404-C5 DW-AV-404-C5-276 19234 DW-AD-405-C5 DW-AS-405-C5 08-MDM
Abstract: Stiftleiste. · Klemme 2 ist jetzt wieder für den Anschluss von NAMUR-Sensoren vorbereitet. 4 5 , MCR-f-UI-DC bn 2-Draht-DC NAMUR-Sensor MCR-f-UI-DC 2-Draht-DC (mechanischer Kontakt) MCR-f-UI-DC , . Darstellung im Einstellbereich y t Frequenzeingang für NAMUR-Sensoren mit Drahtbruch und , PNP-Transistorausgänge · NPN-Transistorausgänge · NAMUR-Initiator · potentialfreier Relaiskontakt (dry contact) · , être raccordée à des détecteurs NAMUR. 36 37 4 GND1 NPN 5 PNP 6 +15 V 7 U IN 7 U IN Phoenix Contact
Original
encodeur incremental TRANSISTOR SUBSTITUTION MCR-F-UI-DC engranaje analogique Convertisseur Tension Frequence D-32823 CISPR11
Abstract: NAMUR Hazardous Location Sensors Sensor Systems NAMUR refers to the standards committee of , therefore are compatible with the NAMUR requirements. NAMUR sensors are typically used for hazardous , O/P FAIL Ch 2 that require extremely compact sensors. Namur Sensors are not stand-alone , sensors, the Namur Sensor uses very low voltage as a source and changes the current passed through as a function of how close the Housing Length target is to the sensing coil. Namur sensors are used with Namco Controls
Original
ET112-00310 ET112-10310 ET112-20310 ET212-20310 ET112-21310 ET212-21310
Abstract: on the input side The input options are as follows NAMUR sensors Frequency generators Dry , NPN PNP 0-10 V 7 NPN PNP DC DC Namur IN DC MCR-f-UI-DC GND ! with , 0.1 Hz.120 kHz · NPN/PNP transistor outputs · NAMUR sensor · Electrically isolated relay contact , NAMUR IN 3 f IN 4 GND1 NPN 5 PNP 6 +15 V 1 +8,2 V 2 NAMUR IN 3 f IN bu 4 GND1 NPN 5 , NPN 5 PNP 6 +15 V I input (DC current) 1 +8,2 V 2 NAMUR IN 3 f IN MCR-f-UI-DC 1 +8,2 Phoenix Contact
Original
phoenix contact MCR R I 4v EN50081-2 generator 4.20 mA
Abstract: R Schaltverstärker NAMUR EN 50227 N 00219 107 22 42 2-kanalig [EEx ia / ib] IIC Normen und Richtlinien 87 35,5 Steuerstromkreis zugelassen für Zone 0 102 NAMUR Schaltverstärker NV 0201 Befestigung auf Tragschiene Der NAMUR-Verstärker NV 0201 erfüllt alle Anforderungen , von NAMUR-Sensoren. · Er liefert die eigensichere Versorgungsspannung für die Sensoren, · wertet , NAMUR. · Il fournit l'alimentation en tension sécurité intrinsèque pour les efector. · évalue les IFM Electronic
Original
N00219 efector namur out put nv0201 EFECTOR proximity 5501 led display DB-FORM--PZD/02/06/95
Abstract: Adjustable Namur Current Output · Low Power Dissipation: 5mW @ 5V The CAN404 is a universal multipurpose , voltage-to-current interface according to the Namur norm is implemented. With only a few external components, the , 18 V Namur: not active, VSET = VM ICC Typ. 5 Supply Voltage Range Min. Namur , k Temperature Coefficient ICC TKICC Tamb = ­25 . 85°C, Namur: active ±200 ppm/°C Namur Output Stage analog microelectronics VM V March 99 2/6 Converter IC for Analog Microelectronics
Original
namur output R01 filters SO20
Abstract: * - Ausführung gemäss NAMUR (DIN 19234) - Exécution selon NAMUR (DIN 19234) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen , Betriebsspannungsbereich UB Tension de service UB (conditions NAMUR) (NAMUR - Bedingungen) Betriebsspannungsbereich UB Tension de service UB (conditions en dehors de NAMUR) (nicht NAMUR) Arbeitswiderstand NAMUR Résistance CONTRINEX
Original
DW-AD-305-M4 DW-AS-305-M4 DW-AD-304-M4 DW-AD-301-M4 DW-AD-303-M4 30X0 DW-AV-301-M4-276 300-M4
Abstract: Ausführung gemäss NAMUR (DIN 19234) - Exécution selon NAMUR (DIN 19234) - Configuration according to NAMUR (DIN 19234) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie) (NAMUR = Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik in der chemischen Industrie , Wiederholgenauigkeit Betriebsspannungsbereich UB (NAMUR - Bedingungen) Betriebsspannungsbereich UB (nicht NAMUR CONTRINEX
Original
DW-AD-425-M8 DW-AS-425-M8-001 DW-AS-423-M8-001 DW-AD-423-M8 DW-AS-421-M8-001 DW-AS-422-M8-001 Contrinex dw-ad-423
Abstract: . - Supply voltage 5 . 30 VDC, output current 10 mA max. - Exécution selon NAMUR (DIN 19234) - Câble de raccordement en PUR - Configuration according to NAMUR (DIN 19 234) Caractéristiques , Tension de service UB (conditions NAMUR) Tension de service UB (conditions en dehors de NAMUR) Résistance de charge NAMUR Résistance recommandée pour UB = 5.10V / 10.20 V / 20.30 V Ondulation , distance sn Hysteresis Standard target Repeat accuracy Supply voltage range UB (NAMUR conditions CONTRINEX
Original
DW-AD-405-M5E INDU400E DW-AD-403-M5E DW-AD-404-M5E DW-AD-401-M5E DW-AD-404-04E DW-AD-403-04E 01-MDM
Abstract: used for intrinsic safety applications. They transfer digital signals (NAMUR sensors/mechanical , applications. It is a universal frequency converter that changes input (NAMUR sensors/mechanical contacts) into , with Trip Values Switch Amplifier Switch Amplifier Switch Amplifier Dry Contact/NAMUR Dry Contact/NAMUR Dry Contact/NAMUR Dry Contact/NAMUR Dry Contact/NAMUR (1 In 2 out) Dry Contact/NAMUR Relay (2) Relay RS Components
Original
UPR-03 KFD2-STC4-EX2 KFD2-STC4-Ex1 kfd2-eb2 namur driver kfd2-stc4 kfd2
Abstract: sizes: 3.5, 5, 6, 10 mm · Power supply: 8.2 VDC (NAMUR) 24 VDC · Output: NAMUR (DIN 19234 , or made in accordance with NAMUR DIN 19234. Sturdy ABS housing. Type Slot size Output type Slot size mm Ordering no. NAMUR Ordering no. Transistor NPN Make swithcing 3.5 5 6 10 DU 3.5 DU 5 DU 6 DU 10 DU 10 E Type Selection DU 6 E DU 10 E Specifications NAMUR , Specifications (cont.) NAMUR Repeat accuracy (R) Effective operating dist. (Sr) Usable operating dist. (Su Carlo Gavazzi
Original
transistor BU 102 bk 101 transistor DIN19234
Abstract: in a singlepiece compact housing â'¢ Epoxy encapsulated â'¢ Available in AC, DC, and Namur , standard 10-30 VDC output, one with 80-250 VAC, and the other a Namurstyle for hazardous location use , Protected 4mm SENSING RANGE NAMUR 2 m Cable 2 m Cable 2 W NAMUR 2 W NAMUR Round Face Flat Face , -pin euro 2 W NAMUR 2 W NAMUR Round Face Flat Face ET912-43351 ET912-53351 4.5V@ 200mA 4.5V , 200mA 11V @ 200mA Max. Load Current @ 25°C 200mA Leakage Current 10ÂuA NAMUR 5-25V DC Namco Controls
Original
Namco ET912-43310 ET912-53310 180/400H 1-800-NAMTECH
Showing first 20 results.