NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
1X Magnetoresistive Wheel-Speed Sensor Honeywell Sensing and Control 1X Magnetoresistive Wheel-Speed Sensor, 4.5 Vdc to 16 Vdc supply voltage, rise time (10 % - 90 %) of 1.5 µs max., 1 pulse per pole pair ri Buy
1.5C Gear-Tooth Sensor Honeywell Sensing and Control 1.5C Gear-Tooth Sensor, 5,0 mm minimum tooth, 10,0 mm minimum slot, 2,0° ± 1.25° operate point ri Buy
1.5Q Gear-Tooth Sensor Honeywell Sensing and Control 1.5Q Gear-Tooth Sensor, 2,5 mm minimum tooth, 2,5 mm minimum slot, 0.5° ± 1.25° operate point ri Buy

methane gas sensor NDIR

Catalog Datasheet Results Type PDF Document Tags
Abstract: Note 1: Background to NDIR Gas Sensing Infrared Sensor Application Note 2: Signal Processing Infrared , , refer to Infrared Gas Sensor Application Note 1. The IR4xxx Series are the same as the IR3xxx Series , deleterious effects of condensation inside the sensor can be offset. At present, the IR42BC IR42BC for methane and , OPERATION To operate as NDIR gas sensors, the IR3xxx and IR4xxx Series must be interfaced to a suitable , the electronics and be positioned close to the gas sensor. Compensation for pressure changes can also ... Original
datasheet

5 pages,
71.21 Kb

benzene GAS SENSOR c2h4 construction of flame detector ACETYLENE GAS SENSOR ethylene gas sensor NDIR CO2 sensor NDIR sensor co2 EN61779-1 methane gas sensor NDIR electrochemical CO2 GAS SENSOR NDIR gas sensor electrochemical gas sensors datasheet abstract
datasheet frame
Abstract: A1A-IR15T A1A-IR15T_25T_Ser Version 6, July 2009 106640 Infrared Sensor Application Note 1: Background to NDIR Gas , (optional 0 ­ 5% vol.) and methane to LFL levels (optional 0 ­ 100% vol.) Diffused gas sampling Low power , * * * * * OPERATION To operate as NDIR gas sensors, the IR15T IR15T and IR25T IR25T Series must be interfaced to a suitable , technologies website, to explain more about NDIR gas sensing and provide advice for the end-user on interfacing , portable combustible gas detector or housed in a remote sensor housing. It has satisfied the requirements ... Original
datasheet

4 pages,
80.3 Kb

Pyroelectric Detectors electrochemical CO2 GAS SENSOR electrochemical gas sensors methane gas detector EN50303 IEC60079-11 A1A-IR15T IEC60079-0 NDIR gas sensor NDIR sensor circuit IR15TT IR15TT-M IR15TT abstract
datasheet frame
Abstract: Overview PerkinElmer has designed a new Natural Gas Alarm Sensor in response to OEMs' needs for highly reliable solution for natural gas detection. The Natural Gas Alarm sensor, as part of the Gas Sensor family, uses nondispersive infrared radiation (NDIR) and combines a robust IR source with a , lifetime as compared to other technology alternatives. The Natural Gas Alarm Sensor is the first low , IO N S Natural Gas Alarm Sensor PYM 151-1 / PYM 152-1 Features and Benefits Dual channel ... Original
datasheet

2 pages,
183.15 Kb

PROPANE sensor DTS0507 gas module sensor Gas sensor "response time" methane gas detector methane gas sensor methane sensor NDIR sensor circuit 6 pin gas sensor infrared gas sensors gas sensor NATURAL GAS SENSOR datasheet abstract
datasheet frame
Abstract: PORTABLE GAS ANALYZER DATA SHEET ZFY This unit is a simple and stable analyzer using a single-beam infrared-ray system. It is designed for measuring carbon dioxide gas (CO2), carbon monoxide (CO) or methane (CH4), and is used to measure atmospheric gases in agricultural vinyl greenhouse, carbon dioxide gas in rooms or carbon dioxide gas, carbon monoxide, ethane, etc., in thermal processing furnaces. FEATURES 1. Single-beam NDIR system is used for simple structure, providing excellent ... Original
datasheet

2 pages,
68.14 Kb

40VA NDIR sensor co2 Carbon Dioxide CO2 Gas Sensor MG-811 ndir CO2 Infrared carbon dioxide CO Gas sensor ndir methane CO2 methane gas sensor NDIR carbon dioxide sensor NDIR gas sensor NDIR carbon monoxide sensor NDIR CO sensor datasheet abstract
datasheet frame
Abstract: IR1xxx Series Miniature Infrared Gas Sensors for Hazardous Areas FEATURES * Configured for carbon dioxide (IR11BD IR11BD), hydrocarbons (IR12BD IR12BD, IR13BD IR13BD) and acetylene (IR14BD IR14BD) * Diffused gas , certification for the IR1xxx Series for use as part of an intrinsically safe portable combustible gas detector or housed in a remote sensor housing. It has satisfied the requirements of CSA standard C22.2 No. , OPERATION The ambient gas diffuses into the optical chamber through a particulate filter at one end of the ... Original
datasheet

5 pages,
76.69 Kb

methane CO2 methane gas detector gas sensor NDIR CO2 sensor E2V certificate application of pyroelectric sensor ir lamp methane CH4 gas detector 99ATEX1121U IR12BD NDIR sensor co2 NDIR gas sensor IR14BD IR11BD IR12BD IR11BD abstract
datasheet frame
Abstract: Overview The new IR Natural Gas Sensor by PerkinElmer was designed in response to OEMs' needs for a highly reliable natural gas detection solution. The IR Natural Gas Sensor, part of , , reliability and lifetime as compared to other technology alternatives. The IR Natural Gas Sensor is the , facilities D A T A S H E E T SENSOR SOLUTIONS IR Natural Gas Sensor PYM 151-1 / PYM 152-1 IR Natural Gas Sensor Product Specifications PYM 151-1 / 152-1 Unit Pre-Alert Level typ. 6% ... Original
datasheet

2 pages,
207.21 Kb

DTS0506P Ir sensor 6 pin pyroelectric infrared sensor PROPANE sensor NDIR sensor circuit AN METHANE SENSOR gas sensors methane sensor GAS SENSOR pyroelectric sensor thermopile array IR Sensor alarm circuit "Pyroelectric Detectors" datasheet abstract
datasheet frame
Abstract: MICROPROCESSOR BASED NDIR GAS ANALYZER DATA SHEET ZRF This NDIR gas analyzer features a , designation of "Z". NDIR TYPE INFRARED GAS ANALYZER (Standard single-component analyzer measuring ranges , Exclusive Zirconia O2 Sensor (to be purchased separately) For O2 correction, the gas analyzer ZRF can , of 250 ppm or more, etc.) may affect the life of the sensor. Gas inlet/outlet size: Rc1/4 Power , The signal from a zirconia O 2 sensor (ZFK3) or other O2 meter enables output of an O2 correction ... Original
datasheet

14 pages,
165.24 Kb

SUS304 methane CO2 motor operated valve for gas NDIR CO sensor NDIR DUAL CO CH4 NDIR gas analyzer cell NOx sensor so2 Gas sensor ndir methane gas sensor NDIR gas sensors AIR FLOW DETECTOR FULL REPORT NDIR gas sensor ndir alcohol sensor datasheet abstract
datasheet frame
Abstract: barometric pressure change. The pressure sensor port should not be connected to the sample gas path. Pressure sensor working range: pabs = 600­1250 hPa 5 EL6010 EL6010 Gas Analyzers in Category 2G 10/24 3.10 , sample gas, reference gas, purge gas and pressure sensor (optional for EL6010 EL6010 Magnos106): Internal flame , not used not used 1) Purge Gas Inlet 1) Purge Gas Outlet 2) Pressure Sensor (EL6010 EL6010 Magnos106 , Inlet 2) Purge Gas Outlet 3) Pressure Sensor Electrical Connections: Data Transmission Cable Feed ... Original
datasheet

16 pages,
199.08 Kb

methane sensor NDIR sensor circuit FFKM75 oxygen gas sensor helium concentration sensor Caldos17 CALDOS so2 Gas sensor ndir methane gas sensor NDIR dmt 01 atex e 037 EL6010-Uras NDIR CO sensor magnos106 EL6010 EL6010 EL6010 abstract
datasheet frame
Abstract: NDIR TYPE INFRARED GAS ANALYZER DATA SHEET ZRG This NDIR gas analyzer features high accuracy , signal from a zirconiz O2 sensor (ZFK3) or from any other O2 sensor, the gas analyzer is able to output , sensor is used for correcting the measured gas concentration into the value at standard O2 , items Note: (3) Data should be put on data code. 11 ZRG NDIR TYPE INFRARED GAS ANALYZER , the life of the sensor. Gas inlet/outlet size: Rc1/4 Power supply: 90 to 126V or 200 to 240V AC ... Original
datasheet

16 pages,
143.81 Kb

carbon dioxide sensor Carbon Monoxide co2 detector dry contact relay 220V Carbon Dioxide CO2 Gas Sensor MG-811 motor operated valve for gas NDIR carbon monoxide sensor AIR FLOW DETECTOR FULL REPORT using led so2 Gas infrared detector o2 sensor methane gas sensor NDIR NDIR CO sensor datasheet abstract
datasheet frame
Abstract: Gas Inlet 1) Purge Gas Outlet 1) Pressure Sensor 2) 24 VDC Connection Cable Opening Data , ) Analyzer Data Sheet ) Purge Gas Inlet 1) Purge Gas Outlet 1) Pressure Sensor 2) Data Transmission , corrosive gases the pressure sensor connection should not be joined with the sample gas path. Note the , (option) Pressure sensor for EL6010-Uras 14, -Magnos106 (option) and -Caldos17 The actual gas , The pressure sensor connection should not be joined with the sample gas path when measuring flammable ... Original
datasheet

82 pages,
3086.58 Kb

carbon monoxide ir sensor CALIBRATION CERTIFICATE F C4H10 ACETYLENE GAS SENSOR magnos 3g call flow methane gas sensor NDIR uras 14 so2 Gas infrared detector NDIR CO sensor EL6010-Uras magnos106 EL6010 EL6010 EL6010 abstract
datasheet frame