500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
PMP5530 Texas Instruments Interleaved Synchronous Buck (12V@30A (40Amax)) for Medical Applications visit Texas Instruments
OMAP1610 Texas Instruments Applications Processor visit Texas Instruments
OMAP1611 Texas Instruments Applications Processor visit Texas Instruments
OMAP310 Texas Instruments Applications Processor visit Texas Instruments
PTDC1000QPWQ1 Texas Instruments Ultrasonic Analog-Front-End 28-TSSOP visit Texas Instruments
STELLARIS-3P-ZHAW-INESPTP-PGRT Texas Instruments InES PTP v2 application visit Texas Instruments

medical application of ultrasonic waves

Catalog Datasheet MFG & Type PDF Document Tags

medical application of ultrasonic waves

Abstract: Application report: Baumer SONUS â'" The smallest and lightest ultrasonic sensors worldwide , Ultrasonic Technology and SONUS In contrast to electromagnetic waves, sonic waves can only propagate , characteristics. It is therefore given that ultrasonic waves can propagate themselves through solid, liquid and , human ear, sound www.baumerelectric.com waves generated by ultrasonic sensors are also reflected , than 1 cm. The use of ultrasonic technology in sensors can be described as representing the current
Baumer
Original

40KHz Ultrasonic Transducer

Abstract: .Applications This specification covers the water proof type ultrasonic ceramic transducer which are used for receiver and transmitter of ultrasonic waves. 2. Features 2.1) Open Structure and dual use 2.2 , prevention/crime prevention equipment 9) Data-processing equipment 10) Application of similar complexity , Midas Ultrasonic Sensors Part Number System MC US T 16 1 2 3 4 P 5 1 = = US: Ultrasonic Sensor 3 = T: Transmitter 4 = Diameter (e.g. 16 = 16mm) 5 = P: Plastic
Midas Sensors
Original

40khz 16mm ultrasonic receiver and transmitter

Abstract: ultrasonic sensor 40khz : Dual 1.Applications This specification covers the water proof type ultrasonic ceramic transducer which are used for receiver and transmitter of ultrasonic waves. 2. Features 2.1) Open Structure , equipment 9) Data-processing equipment 10) Application of similar complexity and/or reliability , Midas Ultrasonic Sensors Part Number System MC US T 16 1 2 3 4 P 5 1 = = US: Ultrasonic Sensor 3 = T: Transmitter 4 = Diameter (e.g. 16 = 16mm) 5 = P: Plastic
Midas Sensors
Original

00bc0w

Abstract: ba50bc0 capacitor will be shortest. P. 5 P. 7 Fig.15 Application drawing Description of operation The , ) Ultrasonic waves cleaning conditions Frequency : 28kHz Ultrasonic waves output : Max. 15W / litter Solvent , seconds (however, within 3 minutes in the case not to use ultrasonic waves.) Liquid temperature : Max. 40 , content (chloride content 0.2wt%) (2) Ultrasonic waves cleaning conditions Frequency : 28kHz Ultrasonic , use ultrasonic waves.) Liquid temperature : Max. 40°C · There shall be no resonance in the
ROHM
Original

ultrasonic 100 khz transmitter

Abstract: BPU1640IOAH12 .Applications This specification covers the water proof type ultrasonic ceramic transducer which are used for receiver and transmitter of ultrasonic waves. 2. Features 2.1) Open Structure and dual use 2.2 , prevention/crime prevention equipment 9) Data-processing equipment 10) Application of similar complexity , Midas Ultrasonic Sensors Part Number System MC US T 16 1 2 3 4 P 5 1 = = US: Ultrasonic Sensor 3 = T: Transmitter 4 = Diameter (e.g. 16 = 16mm) 5 = P: Plastic
Midas Sensors
Original

medical application of ultrasonic waves

Abstract: proximity sensor faucet is that a material capable of supporting shear and torsional mechanical waves at ultrasonic , design and application questions get a very quick, positive "yes" answer. Now, after seven years of , GAMING INDUSTRIAL & PROCESS CONTROL MEDICAL MILITARY/AEROSPACE PETROLEUM EXPLORATION & REFINING , RESISTANT POINT OF SALE ACTIVETOUCH TECHNOLOGY ActiveTouch patented touch-sensitive technology brings a whole new level of durability to switches, sensors and control systems. Whether you define
ITW ActiveTouch
Original
Abstract: Features MED-STETH implements a stethoscope application based Power on LED on the use of ultrasonic waves. This board is auxiliary in the design of applications using ultrasound in the detection of , compatible 3 mm Audio Output Medical Connector â'¢ Hardware-ready solution for ultrasound heart rate monitoring â'¢ Application software available â'¢ Designed for use with TWR-LCD, a 16-bit color screen , Board Connect the MED-STETH board to the TWR-K53N512 medical connector as shown in the image below -
Original
DRM132

DIODE c335

Abstract: C335 resistant as ultrasonic waves. Example : water Propagation speed Solvent density Frequency and wavelength , possible. 4) Move item being cleaned. Standing waves caused by the ultrasonic waves can cause stress to build up in part of the item being cleaned. Reference 2 × Ultrasonic output propagation × speed × , Capacitance Nominal capacitance in pF in 3 digits : 2significant figure representing the number of 0's. 2 , surface of a capacitor. Polarity : The polarity should be shown by bar. (on the anode side) Rated DC
ROHM
Original
DIODE c335 C335

transistor c5101

Abstract: medical application of ultrasonic waves waves caused by the ultrasonic waves can cause stress to build up in part of the item being cleaned , diode, so it is not as resistant as ultrasonic waves. Example : water Propagation speed Solvent , application circuit diagrams information, described herein are intended only as illustrations of such devices , significant figure representing the number of 0's. 2 Case code TCFG ······ D 5 Capacitance tolerance , should be given on the surface of a capacitor. Polarity Rated DC voltage Nominal capacitance [D
ROHM
Original
transistor c5101 medical application of ultrasonic waves C105 C5101-1 C5101-3 M705

transistor c5101

Abstract: TRANSISTOR a105 are larger than those of a transistor or diode, so it is not as resistant as ultrasonic waves , the ultrasonic waves can cause stress to build up in part of the item being cleaned. Reference Kin , application circuit diagrams information, described herein are intended only as illustrations of such devices , : 2significant figure representing the number of 0's. 2 Case code TCFG ····· A 5 Capacitance tolerance M , development Marking The indications listed below should be given on the surface of a capacitor. Polarity
ROHM
Original
TRANSISTOR a105 L 2605 CV a105 transistor Diode J106 transistor marking codes a01 J106

transistor a105

Abstract: a105 transistor those of a transistor or diode, so it is not as resistant as ultrasonic waves. Example : water , short as possible. 4) Move item being cleaned. Standing waves caused by the ultrasonic waves can cause , . Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and , and the malfunction of which would directly endanger human life (such as medical instruments , : 2significant figure representing the number of 0's. 2 Case code TCFG ····· B 5 Capacitance tolerance 3
ROHM
Original
10V-1F OP AMP 7505 ET 3528 G475

diode c335

Abstract: cleaning time as short as possible. 4) Move item being cleaned. Standing waves caused by the ultrasonic waves can cause stress to build up in part of the item being cleaned. Reference 2 × Ultrasonic , diode, so it is not as resistant as ultrasonic waves. Example : water Propagation speed Solvent density , . Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and , Capacitance Nominal capacitance in pF in 3 digits : 2significant figure representing the number of 0's. 2
ROHM
Original

medical application of ultrasonic waves

Abstract: OP AMP 7505 of a transistor or diode, so it is not as resistant as ultrasonic waves. Example : water , . Standing waves caused by the ultrasonic waves can cause stress to build up in part of the item being , : 2significant figure representing the number of 0's. 2 Case code TCFG ····· C 5 3 Rated Voltage Rated , on the surface of a capacitor. Polarity : The polarity should be shown by Rated DC voltage , Tangent of loss angle (Df, tan) Shall be satisfied the voltage on "Standard list" As per 4.8 JIS C
ROHM
Original
op amp 7343 100KHZ ULTRASONIC Transistor W03

a105 equivalent

Abstract: a105 transistor it is not as resistant as ultrasonic waves. Example : water Propagation speed Solvent density , ) Move item being cleaned. Standing waves caused by the ultrasonic waves can cause stress to build up in part of the item being cleaned. Reference Kin etic energy = 2 × × frequency × 2 × Ultrasonic , : 2significant figure representing the number of 0's. 2 Case code TCFG ····· A 5 Capacitance tolerance M , new product Marking The indications listed below should be given on the surface of a capacitor
ROHM
Original
a105 equivalent capacitor 2012 rohm J106 capacitor thermal safety A105

a105 transistor

Abstract: TRANSISTOR a105 are larger than those of a transistor or diode, so it is not as resistant as ultrasonic waves , the ultrasonic waves can cause stress to build up in part of the item being cleaned. Reference Kin , application circuit diagrams information, described herein are intended only as illustrations of such devices , : 2significant figure representing the number of 0's. 2 Case code TCFG ····· B 5 Capacitance tolerance 3 , development : New product Marking The indications listed below should be given on the surface of a
ROHM
Original
TCFGB0G227 C5101 602C 227 10K tantalum capacitors

sr 160 DIODE Equivalent list

Abstract: TRANSISTOR a105 . Standing waves caused by the ultrasonic waves can cause stress to build up in part of the item being , or diode, so it is not as resistant as ultrasonic waves. Example : water Propagation speed Solvent , : 2significant figure representing the number of 0's. 2 Case code TCFG ····· P 5 3 Rated Voltage Rated , size products line-up. Marking The indications listed below should be given on the surface of a , the small size of P case, a voltage code is used as shown below. Nominal capacitance Voltage Code
ROHM
Original
sr 160 DIODE Equivalent list chip resistor rohm 3216 A105 H63A

medical application of ultrasonic waves

Abstract: op amp 7343 caused by the ultrasonic waves can cause stress to build up in part of the item being cleaned , not as resistant as ultrasonic waves. Example : water Propagation speed Solvent density 1500m , application circuit diagrams information, described herein are intended only as illustrations of such devices , : 2significant figure representing the number of 0's. 2 Case code TCFG ····· C 5 3 Rated Voltage Rated , on the surface of a capacitor. Polarity : The polarity should be shown by Rated DC voltage
ROHM
Original
16V100uF transistor 6032

a105 transistor

Abstract: C5101-3 it is not as resistant as ultrasonic waves. Example : water Propagation speed Solvent density , ) Move item being cleaned. Standing waves caused by the ultrasonic waves can cause stress to build up in part of the item being cleaned. Reference Kin etic energy = 2 × × frequency × 2 × Ultrasonic , : 2significant figure representing the number of 0's. 2 Case code TCFG ····· B 5 Capacitance tolerance 3 , development : New product Marking The indications listed below should be given on the surface of a
ROHM
Original

medical application of ultrasonic waves

Abstract: transistor c5101 those of a transistor or diode, so it is not as resistant as ultrasonic waves. Example : water , . Standing waves caused by the ultrasonic waves can cause stress to build up in part of the item being , significant figure representing the number of 0's. 2 Case code TCFG ······ D 5 Capacitance tolerance , listed below should be given on the surface of a capacitor. Polarity Rated DC voltage Nominal , .DC Measuring circuit : DC Equivalent series circuit ±20% Tangent of loss angle (Df, tan) Shall be
ROHM
Original
D CASE TCFG Series

ultrasonic flowmeter transducer circuit

Abstract: medical application of ultrasonic waves utilizing ultrasonic waves is the esoteric directional nature of this technology, which can be focused , 2 Medical Instruments Overview Medical instruments are used in a wide range of , processing tasks. TI's wired and Medical Applications Guide Medical Instruments Table of Contents , . Ultrasonics Ultrasonic technology is not often thought of when leveraging ultra-highperformance analog and , administered drugs and skin/wound therapy. Ultrasonic waves are generated at a frequency above 20 kHz to
Texas Instruments
Original
TMS32064 ultrasonic flowmeter transducer circuit TXB010x digital blood pressure circuit diagram using microcontroller robotic arm pc controlled robot using zigbee interfacing rs232 to zigbee cc2500 C2000 C5000 D093008 SSZB143
Showing first 20 results.