500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
5962-9088801MRA Intersil Corporation DATACOM, MANCHESTER ENCODER/DECODER, CDIP20, CERDIP-20
HD1-6409/883 Intersil Corporation DATACOM, MANCHESTER ENCODER/DECODER, CDIP20, CERDIP-20
7802901JA Intersil Corporation DATACOM, MANCHESTER ENCODER/DECODER, CDIP24, CERDIP-24
HD1-15530-8 Intersil Corporation DATACOM, MANCHESTER ENCODER/DECODER, CDIP24, CERDIP-24
78029013A Intersil Corporation DATACOM, MANCHESTER ENCODER/DECODER, CQCC28, CERAMIC, LCC-28
HD3-6408-9 Intersil Corporation CMOS Asynchronous Serial Manchester Adapter (ASMA); CERDIP24, PDIP24; Temp Range: -40° to 85°C

manchester

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Application Note: CoolRunner® CPLDs R XAPP339 (v1.2) Jaunary 10, 2001 Manchester , and Verilog source code for a Manchester Encoder Decoder. The reasons to use Manchester code are , 6 for instructions. Introduction Manchester code is defined, and the advantages relative to Non-Return to Zero code are given. Target applications of Manchester code are discussed. Verilog and VHDL implementations of the Manchester Encoder-Decoder are available from the Xilinx website. The decoder and encoder Xilinx
Original
vhdl code manchester encoder vhdl code for manchester decoder vhdl code for clock and data recovery manchester verilog decoder manchester encoder manchester code verilog XC9572 XCR3064XL
Abstract: Application Note: CoolRunner® CPLDs R XAPP339 (v1.1) April 17, 2000 Manchester , and Verilog source code for a Manchester Encoder Decoder. The reasons to use Manchester code are , 6 for instructions. Introduction Manchester code is defined, and the advantages relative to Non-Return to Zero code are given. Target applications of Manchester code are discussed. Verilog and VHDL implementations of the Manchester Encoder-Decoder are available from the Xilinx website. The decoder and encoder Xilinx
Original
line code manchester vhdl manchester vhdl code for nrz Manchester code xilinx uart verilog code cyclic redundancy check verilog source
Abstract: INTEGRATED CIRCUITS AN070 Verilog implementation of a Manchester Encoder/Decoder in Philips , implementation of a Manchester Encoder/Decoder in Philips CPLDs AN070 In this application note, Manchester , applications of Manchester code are discussed. A verilog implementation of the Manchester Encoder­Decoder is , functions in CPLDs. In NRZ, only one level/data cell is required, while in Manchester, two levels are , frequency response for NRZ then ranges from DC to clock/2. The frequency response of Manchester code Philips Semiconductors
Original
philips application manchester manchester encoder an070
Abstract: Philips Semiconductors Application note Verilog implementation of a Manchester Encoder/Decoder in Philips CPLDs AKJn_n ANU U INTRODUCTION In this application note, Manchester code is , Manchester code are discussed. A verilog implementation of the Manchester Encoder-Oecoder is given, along , . In NRZ, only one level/data cell is requited, while in Manchester, two levels are required. A DC , then ranges from DC to clock/2. The frequency response of Manchester code ranges from clock/2 -
OCR Scan
MD1010
Abstract: HD-6409 S E M I C O N D U C T O R CMOS Manchester Encoder-Decoder March 1997 Features Description · Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED) is a high speed , , the MED converts Non return-to-Zero code (NRZ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies , converts the most commonly used code (NRZ) to Manchester code, the advantages of using Manchester code Harris Semiconductor
Original
HD3-6409-9 HD9P6409-9 HD1-6409-9 manchester code encoder diagram hd-6409-9 differential manchester encoder 5962-9088801MRA
Abstract: INTEGRATED CIRCUITS AN070 Verilog implementation of a Manchester Encoder/Decoder in Philips , implementation of a Manchester Encoder/Decoder in Philips CPLDs AN070 In this application note, Manchester , applications of Manchester code are discussed. A verilog implementation of the Manchester Encoder­Decoder is , functions in CPLDs. In NRZ, only one level/data cell is required, while in Manchester, two levels are , frequency response for NRZ then ranges from DC to clock/2. The frequency response of Manchester code Philips Semiconductors
Original
philips application manchester verilog verilog code for uart communication manchester verilog
Abstract: HD-6409 CMOS Manchester Encoder-Decoder March 1997 Features Description · Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED) is a high speed, low power device , return-to-Zero code (NRZ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies inherent in , commonly used code (NRZ) to Manchester code, the advantages of using Manchester code are easily realized Intersil
Original
HD4-6409-9 5962-9088801M2A ISO9000
Abstract: signal integrity for the entire system. Manchester encoding is a method used to combine data and a clock to form a single self-synchronizing data stream, while Manchester decoding is to retrieve the , perform the clock data recovery. The Differential Manchester code is an alternative to the standard Manchester code. Both have their advantages and are being used in different application areas. One of the , Manchester code, Differential Manchester code will operate in the same manner if the signal is inverted Lattice Semiconductor
Original
RD1051 vhdl code for PLL differential manchester system design using pll vhdl code Manchester block diagram LCMXO2-1200HC-6TG100CES LCMXO1200E-3T100C LFXP2-5E-5FT256C 1-800-LATTICE
Abstract: HD-6409 ® Datasheet July 29, 2005 CMOS Manchester Encoder-Decoder Features The HD-6409 Manchester Encoder-Decoder (MED) is a high speed, low power device manufactured using self-aligned silicon , Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies inherent in Nonreturn-to-Zero code. For instance , Manchester code, the advantages of using Manchester code are easily realized in a serial data link Intersil
Original
FN2951 HD9P6409-9Z96 HD9P6409-9Z manchester coding
Abstract: Application Note: CoolRunnerTM CPLDs R XAPP339 (v1.3) October 1, 2002 Manchester , and Verilog source code for a Manchester Encoder Decoder. The reasons to use Manchester code are , Download, page 6 for instructions. Introduction Manchester code is defined, and the advantages relative to Non-Return to Zero code are given. Target applications of Manchester code are discussed. Verilog and VHDL implementations of the Manchester Encoder-Decoder are available from the Xilinx website Xilinx
Original
vhdl code for uart communication vhdl code for frame synchronization XILINX XC9572 generation circuit of manchester verilog code for 8 bit shift register verilog code for digital clock XC2C64
Abstract:  SEMICONDUCTOR PRODUCTS DIVISION Of HARRIS CORPORATION HD-6409 CMOS Manchester Encoder-Decoder (MED) Features â'¢ CONVERTER OR REPEATER MODE â'¢ INDEPENDENT MANCHESTER ENCODER AND DECODER , TEMPERATURE RANGE â'¢ 20 PIN PACKAGE Description The HD-6409 Manchester Encoder-Decoder (MED) is a high , MED converts Non Return to Zero code (NRZ) into Manchester code and decodes Manchester code into Non Return to Zero code. For serial data communication, Manchester code does not have some of the -
OCR Scan
HD-6431 HD-6433 HD-6495 decoding of return to zero format manchester code encoder diagram state NON RETURN TO ZERO Biphase decoder TYPJ-30
Abstract: HD-6409 TM CMOS Manchester Encoder-Decoder March 1997 Features Description · Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED) is a high speed, low power , converts Non return-to-Zero code (NRZ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the deficiencies , converts the most commonly used code (NRZ) to Manchester code, the advantages of using Manchester code Intersil
Original
CODER MANCHESTER DIFFERENTIAL srst 15
Abstract: ~ 7^75^ , error detection, the BUS-1555 Manchester II Decoder Module avails itself to a wide range o f , decoder. The BUS-1555 w ill sample Manchester II inpu t data at 16 MHz, which im proves b it recognition , Manchester II phasing errors. Control logic outputs include Line Active, Frame, Sync Detector, Sync Type and , include both ground and on board avionics system. · ERROR FLAGS FOR SYNC MANCHESTER II ERROR HIGH AND -
OCR Scan
td 1555 MIL-STD-1553 MIL-STD1553 BUS-63105 BUS-8559 IL-STD-1553
Abstract: trademarks or requested trademarks of their respective holders. manchester-nrz_ds_19feb13 Teledyne , Manchester and NRZ Configurable Protocol Decode Quickly decode serial buses that use Manchester , help verify bus performance and debug â'¢ U #7; ser definable protocol decoding of Manchester and , color-coded decode is overlaid directly on physical layer waveform The Configurable Manchester and , Manchester or NRZ based The physical layer specs like bit rate, industry standard buses like PSI5, S Teledyne LeCroy
Original
LM10Z 1-800-5-L
Abstract: MANCHESTER '0' MANCHESTER '1' I MANCHESTER'1' | MANCHESTER'0' | MANCHESTER '0' | FIGURE 11. 5-36 HARRIS , T S/V b I HARRIS SEMICOND SECTOR HS rri DE| 4305271 GG11131 1 T-ys-si HD'6409 § CO CMOS Manchester ô Encoder-Decoder (MED) x Features â'¢ Converter or Repeater Mode â'¢ Independent Manchester , +125C Description The HD-6409 Manchester Encoder-Decoder (MED) Is a high speed, low power device , Nonreturn-to-Zero code (NRZ) into Manchester code and décodés Manchester code into Nonreturn-to-Zero code. For -
OCR Scan
CTS Electronic Components converter 1011134 CMOS nrz Level Converter harris 6409 HD-6409-2/-8
Abstract: bit in Manchester-encoded data can become confusing, because each binary data bit encoded results in , Manchester-encoded data stream does require two levels for each transition, because by definition the information is , as many logic-level states to encode data in Manchester. However, the use of the phrase "Manchester , data bit or a Manchester-encoded bit. The term chip is often used to describe the level periods on , 5 shows an example of a Manchester-encoded serial-input data stream and the resulting output data Maxim Integrated Products
Original
MAX1470 MAX1471 MAX1472 MAX1479 MAX7033 AN3435 hardware implementation of bpsk example manchester
Abstract: this article, Manchester. Also it should be mentioned that we are simply looking at coding digital , Manchester Coding Basics When beginning to work with communication systems, it is important to , our communication system. Manchester Coding Basics Application Note 1. Modulation Modulation , or interference will not be detected without some form of data integrity checks. 2 Manchester Coding Basics 9164A­AUTO­09/09 Manchester Coding Basics 2.2 BiPhase BiPhase adds a level of Atmel
Original
utilizes Manchester Bi-Phase Biphase U2270 CS11
Abstract: 04897 D T"7S~S7 ILC DATA DEVICE CORPORATION _ BUS-1555 MIL-STD-1553 MANCHESTER II DECODER FOR TEST , capability and precise message error detection, the BUS-1555 Manchester II Decoder Module avails itself to a , compatible with this decoder. The BUS-1555 will sample Manchester II input data at 16 MHz, which improves , , odd parity and Manchester II phasing errors. Control logic outputs include Line Active, Frame, Sync , include both ground and on board avionics system. ERROR FLAGS FOR SYNC MANCHESTER II ERROR HIGH AND LOW -
OCR Scan
UT 63105 RDO-RD15 63105 7S57 C3C30 4B78769 VII-10
Abstract: (Manchester_Decoding_ook.c / XGATE_Manchester_decoding_ook.cxgate), or FSK modulation (Manchester_decoding_fsk.c , of the core that will be performing the Manchester decoding is in Manchester_Decoder_General.h. , peripherals and internal RAM. The process of decoding Manchester-coded signals requires intensive interrupt , application note discusses a proposed implementation to decode Manchester-coded signals using the XGATE. The , process. Only one timer channel is needed. When a Manchester-encoded signal is sampled in a channel with Freescale Semiconductor
Original
AN3015 HCS12X M68EVB908Q M68EVB908Q 1.2 HCS12x microcontroller Manchester CODING DECODING PROCESS CONTROL TIMER BASED TOPICS
Abstract: HD-6409 Semiconductor March CMOS Manchester Encoder-Decoder 1997 Features Description â'¢ Converter or Repeater Mode The HD-6409 Manchester Encoder-Decoder (MED) is a high speed , mode, the MED converts Non return-to-Zero code (NRZ) into Manchester code and decodes Manchester code into Nonreturn-to-Zero code. For serial data communication, Manchester code does not have some of the , converts the most comm only used code (NRZ) to Manchester code, the advantages of using Manchester code -
OCR Scan
Showing first 20 results.