NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: Application Notes M16C/26A M16C/26A Group Sample Program (Lux Meter) 1. Summary This sample program provides the functionality of a lux, or illuminance meter by using the Renesas Starter Kit for , Program (Lux Meter) 3. Port Arrangement LCD P100 P91 P90 LCD D6 P61 10MHz LCD D7 , Program (Lux Meter) 5. Operational Specification (1)After reset switch depressed (1) The AD , of 16 M16C/26A M16C/26A Group Sample Program (Lux Meter) 6. Definition of the RSK Functionality and ... Original
datasheet

16 pages,
558.09 Kb

panasonic application luxmeter LM358 lux sensor M16C26A M30260F8A M30260F8AGP P100 32KHZ lux meter chip lux meter M16C/26A M16C/26A abstract
datasheet frame
Abstract: value for measurement as measured by the lux meter. · Typically, a better diffusion is obtained at , to 1600 nm. 5. Lux Meter · The equipment for lux measurement is a lux meter. · Example of the , received by both the lux meter and the ambient light sensor is uniform. For product information and a , light sensor. Proposed Test Setup SIDE VIEW OF TEST SETUP R ~= 3 TO 5 CM R >= 10 CM LUX METER POWER SUPPLY VCC VCC AVAGO TECHNOLOGIES AMBIENT LIGHT SENSOR 6 X 6 ARRAY OF WHITE ... Original
datasheet

3 pages,
332.86 Kb

konica application lux meter ambient light sensor "LIGHT Sensor" lux sensor lux meter light sensor receptor HLMP-FW67NP00 datasheet abstract
datasheet frame
Abstract: Foot Candle/Lux Meter Accurate light level measurements Plus analog output for capturing readins to a recorder Features: · Accurately displays light level in terms of Fc or Lux over three ranges: Fc (0-200, 0-2000 and 0-5000Fc) and Lux (0-2000, 0-20000, 0-50000Lux) · Resolution of 0.1Fc or 1Lux with 5% accuracy · Select fast (1 second) or slow (2 seconds) response · Monitor light levels using , Candle/Lux Meter 401025-NIST 401025-NIST .401025 with NIST Certificate 409996 .Vinyl ... Original
datasheet

1 pages,
165.16 Kb

lux meter datasheet abstract
datasheet frame
Abstract: Results Of Light Tube With 308 Pieces 3528 LED (Frosted Tube) Height: 1.95m Lux Meter : Point Extech Easy View 31 (LUX) . -100cm . -77.5cm . -55cm . -22.5cm 0 22.5cm Date 55cm 1/21 , 104 Pieces DomiPlus LED (Frosted Tube) Height: 1.95m Lux Meter : Point Center 337 Mini , 1 mc 5 3 1. Reference: Measurement Of Standard 36W Fluorescent Lamp Height: 1.95m Lux Meter : Point Center 337 Mini Lightmeter . -100cm . -77.5cm . -55cm . -22.5cm Date 55cm ... Original
datasheet

7 pages,
1810.98 Kb

0.5w led lumen output 3528 LEDs led 3528 T8 LED circuit LED tube T8 LED TUBE white 3528 5050 led lux t8 led tube 3528 led 60mW white LED 5050 LED TUBE LIGHT circuit T8/T10 T8/T10 T8/T10 abstract
datasheet frame
Abstract: Introduction. .3 Lux Meter , , Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 3 AN-32 AN-32 OPTICAL DESIGN LUX METER The lighting industry senses ambient light using a lux meter. The optics of a lux meter consists , eliminate "hot spots" that can provide wide shifts in meter output with subtle shifts in position of the appliance. The dome shape helps eliminate the cosine effect which affects the meter reading relative to the ... Original
datasheet

6 pages,
80.26 Kb

lux meter engineered diffusers angle position sensors LX1970IDU LX1971 LX1971IDU LX1972 LX1972IBC LX197X AN-32 optical sensor VISIBLE LIGHT pdf of light photo sensor light meter AN-32 abstract
datasheet frame
Abstract: Lux Output Measuring Condition The total illuminated area is 25 square meters. The vertical center beam at 1M and 2M distance is measured with a lux meter. 1M 2M Everlight Electronics Co. , values are measured by the TES 1336A lux meter. The above values are rounded and are for reference only. The margin of error in lux meter Everlight Electronics Co., Ltd. Device No. :DBM-0000051 DBM-0000051 5%. , Iliumination Lux Output* OL-Deluxe-BL2 HF LF 3000K 3000K 4000K 4000K 5000K 5000K 6000K 6000K 3000K 3000K 4000K 4000K ... Original
datasheet

5 pages,
338.44 Kb

TES 1336A t5 lighting Cobra led 6000k T5 LED TUBE t5 tube lux datasheet abstract
datasheet frame
Abstract: production Reference Lux Output Measuring Condition The total illuminated area is 25 square meters. The vertical center beam at 1M and 2M distance is measured with a lux meter. 1M 2M , 510 545 545 * The values are measured by the TES 1336A lux meter. The above values are rounded and are for reference only. The margin of error in lux meter Everlight Electronics Co. , Technical Data Sheet Iliumination Lux Output* OL-Deluxe-BL2 HF LF 3000K 3000K 4000K 4000K 5000K 5000K ... Original
datasheet

5 pages,
344.65 Kb

TES 1336A led 6000k T5 LED TUBE tes 1310 datasheet abstract
datasheet frame
Abstract: Lux Output Measuring Condition The total illuminated area is 25 square meters. The vertical center beam at 1M and 2M distance is measured with a lux meter. 1M 2M Everlight Electronics Co. , 305 * The values are measured by the TES 1336A lux meter. The above values are rounded and are for reference only. The margin of error in lux meter Everlight Electronics Co., Ltd. Device No. , Product Series (EU) Iliumination Lux Output* BL4 lux OL-Deluxe-TL2 HF LF 3000K 3000K 4000K 4000K ... Original
datasheet

5 pages,
335.96 Kb

t5 tube lux T5 LED TUBE everlight t5 datasheet abstract
datasheet frame
Abstract: meters. The vertical center beam at 1M and 2M distance is measured with a lux meter. The values are measured by the TES 1336A lux meter. The above values are rounded and are for reference only.The margin of error in lux meter 5%. Label Explanation Customer P/N Company , Technical Data Sheet Illumination Lux Output* OL-Wedge/ML2 HF LF 3000K 3000K 4000K 4000K 5000K 5000K 6000K 6000K 3000K 3000K 4000K 4000K 5000K 5000K 6000K 6000K Lux @ 1m 190 225 240 240 215 255 270 270 ... Original
datasheet

4 pages,
287.29 Kb

t5 tube lux LED TUBE LIGHT 220 VAC 2670K datasheet abstract
datasheet frame
Abstract: The vertical center beam at 1M and 2M distance is measured with a lux meter. The values are measured by the TES 1336A lux meter. The above values are rounded and are for reference only. The margin of error in lux meter 5%. Label Explanation Customer P/N Company , Data Sheet Iliumination Lux Output* HF OL-Flat/ML2 LF 3000K 3000K 4000K 4000K 5000K 5000K 6000K 6000K 3000K 3000K 4000K 4000K 5000K 5000K 6000K 6000K Lux @ 1m 190 230 250 250 220 260 280 280 ... Original
datasheet

4 pages,
295.38 Kb

t5 tube lux lux meter led lamp 230v simple circuit diagram light tube datasheet abstract
datasheet frame

Extended Electronics Archive (Experimental)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
Device Results CD Home | E-Power Meter - Light Sensor Device Datasheet Link Device @ E V = 100Lux (uA) Lux Range (Max) (Lux) Output Current @ E V = 100Lux (uA) Dark Current @ E V = 0Lux (uA) Rise Time (us) Fall Time (us) Delay Time, Rising Edge (us) Delay Time, Falling Edge (us 2.5 5.5 62 10000 60.5 0.15 105 @ 300Lux 170 @ 300Lux 165 @ 300Lux 65 @ 300Lux 2.1x2.0x0.7 Yes Yes 5 Ld DFN 5 Ld DFN T+R Eval Board
www.datasheetarchive.com/files/intersil/device_pages/parametric_application_5716.html
Intersil 17/09/2006 4.42 Kb HTML parametric_application_5716.html
Features Monolithic IC containing photodiode and amplifier 1lux to 8,000lux range Converts light ) 2.5 Supply Voltage (Max) (V) 5.5 Supply Current @ E V = 100Lux (uA) 62 Lux Range (Max) (Lux) 10000 Output Current @ E V = 100Lux (uA) 60.5 Dark Current @ E V = 0Lux (uA) .15 Rise Time (us) 105 @ 300Lux Fall Time (us) 170 @ 300Lux Delay Time, Rising Edge (us) 165 @ 300Lux Delay Time, Falling Edge (us) 65 @ 300Lux Package Dimensions (mm) 2.1x2.0x0.7 Pb-Free? Yes Enable Pin? Yes Application Block
www.datasheetarchive.com/files/intersil/device_pages/device_el7900.html
Intersil 07/09/2006 22.66 Kb HTML device_el7900.html
rejection 15-bit effective resolution Adjustable resolution: 3 to 15 counts per lux Simple output code, directly proportional to lux 0.3lux to10,000lux range 50Hz/60Hz rejection I 2 C interface 2.5V to 3 A) 280 Lux Range (max) (Lux) 10000 Counts per Lux (max) (Counts/Lux) 15 Output Interface I 2 C Output light meters Lighting controls HVAC Related Devices Parametric Table ISL29002 ISL29002 ISL29002 ISL29002 Light
www.datasheetarchive.com/files/intersil/device_pages/device_isl29001.html
Intersil 07/09/2006 21.33 Kb HTML device_isl29001.html
selectable Min. illuminance of Subject : 0,5 lux or less (F2.0 AGC ¨ON¨, output level of 50% S/N ratio supply a video signal up to 100 meters without amplification. Monitor : Any kind of black +/- 10 meters from the camera. #8;#8;#8;#8; #8; 04 Page 3 Page 1 Page 2 LUX REMARK LIGHT CONDITIONS SW1 SW2 Ambient 2 SW1 OFF ON OFF ON 4 3 6 5 1 2 1000.000 lux 10.000 90
www.datasheetarchive.com/download/71367907-609249ZC/vpc405ga.doc
Pacific 23/04/1999 335.5 Kb DOC vpc405ga.doc
1/3 Inch Monochrome Remote Head KP-MB30 KP-MB30 KP-MB30 KP-MB30 The KP-MB30 KP-MB30 KP-MB30 KP-MB30 is a two piece camera featuring an extremely compact remote head that is only 12.6 mm in diameter, by 41.5 mm in length. Designed for imaging requirements where space and weight are restricted, the camera head caan be seperated from the CCU by up to 30 meters of cable. The samll size head, and large distance between the head the CCU microlens Pixels: 768 x 494 Cell Size: 6.35 x 7.4 Resolution: 470 TV lines Min. Illum: 4.0 lux
www.datasheetarchive.com/files/hitachi/hdata/www_data/data/camera/kp/kpmb30.txt
Hitachi 28/10/1997 1.42 Kb TXT kpmb30.txt
2000 lux. 12) Minimum illumination: 8 lux approx. (f1.4, +18dB) (with micro lens) 2 lux approx.(f1.4 +30dB option. required to change software) 13 meter made by Rhode & Schwarz with GAMMA OFF, DTL OFF, MASK OFF, and CHROMA OFF under the standard shooting conditions. The noise meter is set as follows: LPF: 4.5MHz HPF
www.datasheetarchive.com/files/hitachi/hdata/www_data/data/camera/sk/sk2700w.txt
Hitachi 02/01/1998 8.51 Kb TXT sk2700w.txt
Hitachi 3 CCD Cameras 2 Piece, 3 CCD Color HV-C22 HV-C22 HV-C22 HV-C22 Designed for microscope, medical, and industrial applications, the HV-C22 HV-C22 HV-C22 HV-C22 achieves superb performance due to the 3 microlens CCD's mounted to a high performance prism. The camera accepts standard C-Mount opics, and is readily adaptable to microscope mounting. The camera head can be seperated from the CCU by up to 100 meters of cable, which : 5.5 lux at f1.8 S/N: 60 db AGC: Off/On selectable limit Shutter: 1/60-1/10000 or AES Lock Scan
www.datasheetarchive.com/files/hitachi/hdata/www_data/data/camera/hvc/hvc22.txt
Hitachi 28/10/1997 1.6 Kb TXT hvc22.txt
) under the lighting conditions of color temperature of 3200K 3200K 3200K 3200K and illuminance of 2000 lux. 12) Minimum illumination: 8 lux approx. (f1.4, +18dB) (with micro lens) 13) Signal-to-noise ratio: 60dB typical The signal-to-noise ratio is measured by the noise meter made by Rohde & Schwarz with GAMMA OFF, DTL OFF, MASK OFF, and CHROMA OFF under the standard shooting conditions. The noise meter is
www.datasheetarchive.com/files/hitachi/hdata/www_data/data/camera/sk/sk2600w.txt
Hitachi 29/10/1997 7.8 Kb TXT sk2600w.txt
and luminance of 2000 lux. 12) Minimum illumination: 8 lux -to-noise ratio is measured by the noise meter made by Rhode & Schwarz with GAMMA OFF, DTL OFF, MASK OFF, and CHROMA OFF under the standard shooting conditions. The noise meter is
www.datasheetarchive.com/files/hitachi/hdata/www_data/data/camera/sk/sk2700pw.txt
Hitachi 29/10/1997 9.96 Kb TXT sk2700pw.txt
conditions of color temperature of 3200K 3200K 3200K 3200K and illuminance of 2000 lux. 12) Minimum illumination: 8 lux approx. (f1.4, +18dB) (with micro lens) 13) Signal-to-noise ratio: 62d noise meter made by Rohde & Schwarz with GAMMA OFF, DTL OFF, MASK OFF, and CHROMA OFF under the standard shooting conditions. The noise meter is set as follows: LPF
www.datasheetarchive.com/files/hitachi/hdata/www_data/data/camera/sk/sk2060w.txt
Hitachi 01/12/1997 10.57 Kb TXT sk2060w.txt