500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
ISL45042IRZ-TK Intersil Corporation LCD Module Calibrator; DFN8; Temp Range: -40° to 85°C visit Intersil Buy
ISL45042IRZ-T Intersil Corporation LCD Module Calibrator; DFN8; Temp Range: -40° to 85°C visit Intersil Buy
ISL45042IRZ Intersil Corporation LCD Module Calibrator; DFN8; Temp Range: -40° to 85°C visit Intersil Buy
ISL29033IROZ-T7 Intersil Corporation Ultra-Low Lux, Low Power, Integrated Digital Ambient Light Sensor with Interrupt Function; ODFN6; Temp Range: -40° to 85°C visit Intersil Buy
ISL29112IROZ-T7A Intersil Corporation Low Power, 100 Lux Optimized, Analog Output Ambient Light Sensor; ODFN6; Temp Range: -40° to 85°C visit Intersil
ISL29112IROZ-T7 Intersil Corporation Low Power, 100 Lux Optimized, Analog Output Ambient Light Sensor; ODFN6; Temp Range: -40° to 85°C visit Intersil

lux meter calibration

Catalog Datasheet MFG & Type PDF Document Tags

luxmeter

Abstract: 5908V0120 / Footcandle Meters MAVOLUX 5032C/B Features · Illuminance can be measured in Lux or Footcandles · Luminance can be measured in candles per square meter (cd/m²) or Footlamberts (fL) with optional luminance , eye · Rugged instrument design, easy operation · Leather ever-ready case included · Calibration , Technical Data Automatic / Manual Measuring Range Selection Either Lux or footcandles can be selected as a , Lichtmeßtechnik GmbH Technical Data MAVOLUX 5032C Meas. Quantity Measuring Range in Lux (lx) in
GOSSEN Foto- und Lichtme
Original
5908V0120 Z481B H997B luxmeter foto sensor lux meter calibration application luxmeter foto diode 5032/T7 5032B M491A M492A
Abstract: that temperature. For example, if the user uses CL-200 (color lux meter) to measure color temperature , corrected lux value to match the Lux Meter (CL-200 or T-10). The absolute gain can be changed to  , , Green and Blue as well as X, Y and Z corrected lux measurements and also performs interrupt functions , interface for exercising the device features. RGB Chroma Meter Setup The system (MCU, DUT) is powered , '¢ uv-xy table (Installer File) â'¢ CCM Calibration Worksheet (Installer File) â'¢ User Guide (Installer Intersil
Original
LM3940IMP-3 SN65220DBVR 1/16W CR0402-16W-00T CR0402-16W-102JT ERJ-2RKF1002X
Abstract: lux meter) to measure color temperature and certain lux level of an illuminant (3200K) then takes , averaging. 8. Allows user to change absolute gain of corrected lux value to match the Lux Meter (CL-200 or , , Green and Blue as well as X, Y and Z corrected lux measurements and also performs interrupt functions , exercising the device features. RGB Chroma Meter Setup The system (MCU, DUT) is powered directly from , '¢ uv-xy table (Installer File) â'¢ CCM Calibration Worksheet (Installer File) â'¢ User Guide (Installer Intersil
Original
L29125IROZ ERJ2RKF1003 CRCW0402300RFKED CR0402-16W-4701FT 1/10W ERJ-2RKF4990X

NORP12

Abstract: Light dependent resistors ranges. (Calibration should be made against an accurate meter.) Figure 10 Extremely sensitive light , and burglar alarm systems. Guide to source illuminations Light source Illumination (Lux , °K tungsten light source Parameter Cell resistance Conditions Min. Typ. Max. Units 1000 lux 400 10 lux 9 k Dark resistance 1.0 M Dark capacitance 3.5 pF Rise time 1 1000 lux 2.8 ms 10 lux 18 ms Fall time 2 1000 lux 48 ms 10 lux 120 ms 1. Dark to 110% RL 2. To 10 RL RL =
RS Components
Original
NORP12 Light dependent resistors application of light sensitive alarm VR1 100K preset light meter F1418 NSL19-M51 F14188

Light dependent resistors

Abstract: NSL-19M51 ranges. (Calibration should be made against an accurate meter.) Figure 10 Extremely sensitive light , and burglar alarm systems. Guide to source illuminations Light source Illumination (Lux , °K tungsten light source Parameter Cell resistance Conditions Min. Typ. Max. Units 1000 lux 400 10 lux 9 k Dark resistance 1.0 M Dark capacitance 3.5 pF Rise time 1 1000 lux 2.8 ms 10 lux 18 ms Fall time 2 1000 lux 48 ms 10 lux 120 ms 1. Dark to 110% RL 2. To 10 RL RL =
RS Components
Original
NSL-19M51 of preset vR1 200k NORP12 RS stock number 651-507 596-141 232-381 light sensitive alarm

NORP12

Abstract: RELAY 12V preset to give two overlapping ranges. (Calibration should be made against an accurate meter.) Figure , and burglar alarm systems. Guide to source illuminations Light source Illumination (Lux , °K tungsten light source Parameter Cell resistance Conditions 1000 lux 10 lux Dark resistance Dark capacitance Rise time 1 1000 lux 10 lux Fall time 2 1000 lux 10 lux Min. 1.0 - Typ. 400 9 3.5 , characteristics Parameter Cell resistance Conditions 10 lux 100 lux Dark resistance 10 lux after 10 sec
RS Components
Original
IN4148 2N3053 BC107 RELAY 12V 12v relay PRESET VR1 50K vr1 2.2k NORP-12

lux meter calibration

Abstract: light dependent resistors Min. Typ. Max. Units automatic lighting control, batch counting and burglar Cell resistance 1000 lux -400 W alarm systems. 10 lux - 9 - kW Dark resistance -1.0 - - MW Dark capacitance 3.5 pF Guide to source illuminations - - Rise time 1 1000 lux -2.8 -ms Light source Illumination (Lux) 10 lux -18 -ms Moonlight _ 0.1 Fall time 2 1000 lux -48 -ms 60W bulb at 1m _ 50 10 lux -120 -ms 1W MES bulb at 0.1m _ 100 1. Dark to 110% R L
RS Components
Original
light sensitive alarm circuit of VR preset 200k norp12 cds NSL-19M51RS
Abstract: lux and 30â'™000 lux. [5] After user calibration. Additional angle related deviation of ± 0.01° per , ) Calibration cycle Not applicable  Not applicable Maximum altitude 3000 m 3000 m 3000 m , /distance Fluke 424D, 419D, and 414D Distance Meters Laser Distance Meter Laser Distance Meter Laser Distance Meter All models include: Laser distance meter, two AAA batteries, users manual on CD, quick reference guide, vinyl carrying pouch, and three-year warranty Why use a distance meter? 2 Fluke FLUKE
Original
3028711E

ultrasonic distance meter

Abstract: A23 battery / Distance Meter Light Meter Function MT940 Range Lux Range Foot Candles Light Basic Accuracy , CELL MEASUREMENT OFF LUX LUX Light Meter MT 940 £39.95 Ultra-sonic Distance , IECP UKA IEC 2P TECC 40 44 www.socketandsee.co.uk Calibration: The microprocessor is self-calibrating, no other form of calibration is necessary This product is EMC and LVD compliant WHAT , ) Current consumption:
Socket & See
Original
EN1010 ultrasonic distance meter A23 battery HD308 MEW-001 32A plug 60/TCN MT470 EN61010-1 EN61010-2-031

Si1120

Abstract: simple proximity detector , yields the final calculated lux value. Without any calibration, it should be possible to arrive within , Typically 50 cm meter proximity High EMI immunity without range with single pulse shielded packaging , proximity ranges ­40 to +85 °C 3 dc ambient ranges Typical 10 µA current 1 calibration mode , = 3.7 V (Mode 3) - 48 - mW/cm2 Calibration Mode PRX Pulse Width Tpwcal VDD = 3.3 , LED current Proximity, 50 mA LED current, high reflectance range Offset calibration (proximity mode
Silicon Laboratories
Original
Si1120 simple proximity detector LED LEVEL METER DRIVER PRX50 Si11

iAC2.0

Abstract: APDS-9900 2000 1000 0 0 1000 2000 3000 4000 5000 Meter LUX 6000 7000 8000 Figure 2. Spectral Response 1600 1400 1200 Avg Sensor LUX 1000 800 600 400 200 0 0 300 600 900 Meter LUX 1200 1500 Figure 3a. ALS Sensor LUX vs. Meter LUX using Fluorescent Light 0.1 0.08 Avg Sensor LUX 0.06 0.04 0.02 0 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Meter LUX 0.1 Figure 3b. ALS Sensor LUX vs. Meter LUX using Incandescent Light Figure 3c. ALS Sensor LUX vs. Meter LUX using Low Lux Fluorescent Light 1.2
Avago Technologies
Original
APDS-9900 APDS-9901 iAC2.0 digital lux meter circuit with ldr sensor LDR diagram simple circuit design of ldr sensor APDS-9900/9901 AV02-2867EN

iAC2.0

Abstract: APDS-9900 2000 1000 0 0 1000 2000 3000 4000 5000 Meter LUX 6000 7000 8000 Figure 2. Spectral Response 1600 1400 1200 Avg Sensor LUX 1000 800 600 400 200 0 0 300 600 900 Meter LUX 1200 1500 Figure 3a. ALS Sensor LUX vs. Meter LUX using Fluorescent Light 0.1 0.08 Avg Sensor LUX 0.06 0.04 0.02 0 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Meter LUX 0.1 Figure 3b. ALS Sensor LUX vs. Meter LUX using Incandescent Light Figure 3c. ALS Sensor LUX vs. Meter LUX using Low Lux Fluorescent Light 1.2
Avago Technologies
Original
LDR sensor circuit and implementation high lux LDR 10 ohm ldr photodiode ADC ldr sensor FOR LIGHT SENSING MBC604

B5102ES

Abstract: B5103ES lux level required using a calibrated lux meter, once the "room" being measured is complete. This is , TWN-LUX Light Sensor. Light Intensity (LUX) Sensor and 3 Wire Output Transmitter. I REG 1 900 S ISOP P L I U E R The TWN-LUX incorporates a silicon photodiode light sensor, in a , ST E RE D Description. Standard Calibration: 0~1000lux Nominal. Specifications. Input , based on Standard Calibration Unit, unless otherwise specified. Note 2. Due to ongoing research and
Vespo Marketing Associates
Original
B5102ES B5103ES lux sensor Next lux Photodiode as light sensor Trimpot 300 49-VESPO 36-VESPO

61-682

Abstract: 61-494 cFrequency cLifetime Warranty cDiode Protected cAuto Calibration cPocket Size, Low Cost Analog Meter , Grade 947-1722. 61-722. True RMS, frequency, peak hold Digital Multimeters Digital Light Meter , Meters Low Battery Indicatorc cPeak Hold cDigital/Analog Output Features cFoot Candle and Lux Measurement c2000 A Current Capability cRange Up to 20,000 Foot Candles or Lux cBroad Frequency Response — 40 , . 61-681. Stick Light Meter .EACH 161.85 Power Circuits cOutput Jacks for Recording
Allied Electronics Catalog
Original
61-682 61-494 61-702 61-635 DM-5300

lux meter calibration

Abstract: . For example, a comparison of received light for a given output image versus the factory calibration , during calibration and printing the correct amount of ink is being deposited onto the paperâ'"an , gauge color with light levels as low as 0.005 lux to handle dark environments, such as operation under IR glass, but still cope with intensities of up to 10,000 lux in applications where the glass , processor to continuously adjust the lux range and ensure that the display maintains consistent perceived
Intersil
Original
ISL29125 ISL29125EVAL1Z
Abstract: Temperature Meter The Amprobe TMD-10 is a completely portable, dual input thermometer. With a digital dual , thermocouple probes TH-1 Compact Probe Style Relative Humidity Meter Take Amprobeâ'™s TH-1, a small portable RH/Temp meter, anywhere for those quick comfort-level measurements. Offers an easy-to-read dual , Meter with Wet Bulb and Dew Point Amprobeâ'™s THWD-5 psychrometer is a microprocessor-based unit , measurements in one meter B Relative Humidity, Temperature, Dew Point and Wet Bulb B Extended probe for easy Amprobe
Original
877-AMPROBE

LDR sensor circuit and implementation

Abstract: WAVELENGTH (nm) 900 1000 0 1100 1000 2000 3000 4000 5000 Meter LUX 6000 7000 , 200 0 0 Figure 3a. ALS Sensor LUX vs. Meter LUX using Fluorescent Light Figure 2. Spectral Response Avg Sensor LUX 6000 0 300 600 900 Meter LUX 1200 0 1500 Figure 3b. ALS Sensor LUX vs. Meter LUX using Incandescent Light 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Meter LUX 0.1 Figure 3c. ALS Sensor LUX vs. Meter LUX using Low Lux Fluorescent Light 1.2
Avago Technologies
Original

PRX400

Abstract: infrared photodiode , yields the final calculated lux value. Without any calibration, it should be possible to arrive within 50 , Typically 50 cm meter proximity High EMI immunity without range with single pulse shielded packaging Seven , ranges ­40 to +85 °C 3 dc ambient ranges Typical 10 µA current 1 calibration mode consumption Low-noise , V µW/cm2 mW/cm2 mW/cm2 us µA mA mA %/°C µs Lx kLx kLx Calibration Mode PRX Pulse Width Tpwcal TXO , , high reflectance range Offset calibration (proximity mode, no LED current) Visible ambient (10 klux
Silicon Laboratories
Original
PRX400 infrared photodiode PRX50H C8051F931

381626

Abstract: 381275 . Foot candle/lux meter .EACH 169.00 631-0063. 445603. Humidity , Meter cMeasures to 600°F without Contact kHz with a Sample Rate of 1 Million cSuper Large LCD Display , 2.8 ¥ 1.5") Candles or Lux Plus Four Lighting Surface Applications cMultiMeter Display: 4000 Count , Trigger Voltage/Current, Resistance, c cPocket Size Meter Complete with Batteries Capacitance, Frequency , Calibration Bottles cAutoranging with Data Hold and Range Hold Functions cData Hold for Freezing the LCD
Allied Electronics Catalog
Original
IEC1010-1 381626 381275 IEC-1010-1 clamp-on SW810 RS232 RS-232
Abstract: Meter LUX 25000 30000 Figure 3a. ALS Sensor LUX vs. Meter LUX using White Light 1200 0.08 , 600 900 Meter LUX 1200 0 1500 Figure 3b. ALS Sensor LUX vs. Meter LUX using Incandescent Light 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 Meter LUX 1.15 1.20 1.10 Normalized IDD @ 3V 1.20 1.30 Normalized IDD @ 3 V 25° C 0 Figure 3c. ALS Sensor LUX vs. Meter , (without front glass) thus eliminating the need for factory calibration of the end equipment or Avago Technologies
Original
APDS-9930 AV02-3190EN
Showing first 20 results.