500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
MSP430-3P-LSDM-M-BUS-DSGKT Texas Instruments M-Bus visit Texas Instruments
MSP430-3P-EMBED-M-XX-ADPT Texas Instruments M-xx Breadboard Units visit Texas Instruments
ISL6218CRZ-T Intersil Corporation Single Phase IMVP-IV Controller for Intel Pentium M; QFN40, TSSOP38; Temp Range: 0° to 70° visit Intersil Buy
ISL6218CRZ Intersil Corporation Single Phase IMVP-IV Controller for Intel Pentium M; QFN40, TSSOP38; Temp Range: 0° to 70° visit Intersil Buy
ISL6218CVZA Intersil Corporation Single Phase IMVP-IV Controller for Intel Pentium M; QFN40, TSSOP38; Temp Range: 0° to 70° visit Intersil Buy
ISL6218CVZ-T Intersil Corporation Single Phase IMVP-IV Controller for Intel Pentium M; QFN40, TSSOP38; Temp Range: 0° to 70° visit Intersil Buy

kwh meters

Catalog Datasheet MFG & Type PDF Document Tags

kwh meter

Abstract: ct kwh meter 3 phase KWhThree Phase KWh Meters Meters Single & Three Phase MKT Series with integral CT's AM , 's for the AM Series. All meters provide a pulsed output (100ms) AM type Three Phase KWh Meters MKT , meter, double tariff. Two electromechanical meters displaying kWh. Meter type ARM - ITF: 3 phase active & reactive energy meter. Two electromechanical meters displaying KWh and KVArh. Three phase , External unlimited CT ratio selection DIN rail or Panel Mounting or screw fixing KWh Meters Single &
Starkstrom
Original

kwh meters

Abstract: IEC521 KILOWATT HOUR METERS DESCRIPTION DIN96 meters for measuring kWh of individual machines or , Pulsed output (0.1, 1 or 10 per kWh) · Analogue output · Non standard pulse width · Calibration at temp. other than 23°C · Calibration at Hz 35-450 kWh meters are also available in DIN rail 100mm , systems. Savings can be made by monitoring and using electricity at the optimum time. 11840 D96 kWh METERS Dimensions (mm) Manufactured to BS5685, IEC521 with a class accuracy of 1% to IEC1036, and
Howard Butler
Original
kwh meters IEC 1036 iec 1036 kwh IEC-1036 DIN-96 UL94V0

kwh meters

Abstract: MANGANIN Ausgabe / Issue : 18/12/2001 Precision Resistors for kWh Meters Typ / type BVO Technische Daten / technical data Widerstandswerte resistance values siehe Tabelle 1 Toleranz tolerance Temperaturkoeffizient temperature coefficient ( tcr ) Temperaturbereich applicable temperature range refer to table 1 5% Belastbarkeit max. pulse power Innerer Wärmewiderstand , Ausgabe / Issue : 18/12/2001 Precision Resistors for kWh Meters Typ / type BVO Abmessungen ( mm
Rhopoint Components
Original
MANGANIN BVO-M-R0002-1
Abstract: Amprobe® Test Tools Page 1 of 1 search Keyword/Model Search Product Specials Model: SC-3000 Signal Clamp Clamp-ons Environmental Testers Ground Resistance Testers Home Features High Voltage Testers KWH Meters Megohmeters Used to induce tracing signal to pipes, wires or cables Accommodates cables and wires up to 4" in diameter Does not require direct connection to the bare metal of wire Multimeters Phase Seq/Motor Protection Power Quality Recorders Amprobe
Original
Abstract: Amprobe® Test Tools Page 1 of 1 search Keyword/Model Search Model: MTL-90B Set of Test Leads with Alligator Clips Product Specials Clamp-ons Environmental Testers Ground Resistance Testers Home Features High Voltage Testers KWH Meters Megohmeters High quality set of test leads with alligator clips Multimeters Phase Seq/Motor Protection Power Quality Recorders Remcon Relays Volt/Amp/Continuity Testers Wire Tracers Accessories Replacement Parts Amprobe
Original

C 4834 transistor

Abstract: ) Model Number Price Voltage Elements Wire CTs* KWH/Demand Meters: KWDM , 3 KWH Meters: KWM-4234/* 655 120/208 3 4 3 KWM-4834/* 655 277/480 3 4 3 KWM , Kilowatt Hour/ Demand Meters MADE IN USA KWM Series KWDM Series 655 $932 $ Basic Unit Basic Unit ß Microprocessor Based ß Remote Current Transformer Operated ß LED Operational Indicators ß No Multipliers ß KWM-4000 Includes 6 Digit Electro-mechanical Display for KWHr
Omega Engineering
Original
C 4834 transistor KWDM-7000 KWDM-7234/ KWDM-7834/ KWDM-7833/ KWDM-7433/ KWDM-7432G/

kwh meters

Abstract: neon bulb indicator Amprobe® Test Tools Page 1 of 1 search Keyword/Model Search Model: PY-1 AC/DC High Voltage Tester Product Specials Clamp-ons Environmental Testers Ground Resistance Testers Home Features High Voltage Testers KWH Meters Megohmeters AC Volts 115/220/277/400 DC Volts 125/300/400/600 Automatically indicates voltage of circuit under test Four neon bulb indicator lamps Multimeters Phase Seq/Motor Protection Power Quality Recorders Remcon Relays Volt/Amp/Continuity Testers
Amprobe
Original
neon bulb indicator Indicator Lamps testers ampro AMPROBE
Abstract: Amprobe® Test Tools Page 1 of 1 search Keyword/Model Search Model: RS-232 KIT2 Data Recording System for Digital Multimeters or Clampons Product Specials Clamp-ons Environmental Testers Ground Resistance Testers High Voltage Testers Home Accessories KWH Meters Megohmeters Download cable can be converted to USB with an optional RS-USB adapter (ordered separately) Software compatible with Windows 95/98/ME/NT/2000/XP Multimeters Phase Seq/Motor Protection Power Quality Amprobe
Original

ampro

Abstract: testers Amprobe® Test Tools Page 1 of 3 search Keyword/Model Search Model: VP-440 Non-Contact Volt Probe Product Specials Clamp-ons Environmental Testers Ground Resistance Testers Home Features High Voltage Testers KWH Meters Megohmeters Multimeters Phase Seq/Motor Protection Power Quality Recorders Remcon Relays Volt/Amp/Continuity Testers Wire Tracers Accessories Replacement Parts Detects AC Voltage (110 ­ 600V) Uses non-contact method of Voltage testing Totally
Amprobe
Original

product catalogue

Abstract: eltime.co kWh Meters 22 Meter Options 23-24 Dimensions Fax: +44 (0) 1621 855335 , Meters (kWh Meters) 20 Kilowatt hour meters are suitable for the monitoring of active energy , ) as DC systems. The panel mounting kWh meters are accurate to class 1 to IEC1036 and AC models have a , to data loggers, PLCâ'™s, building management systems or computers. i kWh Meters â'" for , 39.0 6.0 Terminals for EL96GT only Removable cover on kWh Meters Max. Panel Thickness
Eltime Controls
Original
product catalogue eltime.co FE72MIA BS7626 FE96MCA

ph a4 250V 2A

Abstract: EN50470-1 active electrical energy meters (see Annex MI-003). · Class 1 (kWh) according to EN62053-21 · Class , pulse. Outputs connectable to the energy meters (kWh/kvarh) 100ms < 120msec (ON), 120ms (OFF , contact 500k, open contact Selectable: · total and partial energy meters (kWh and kvarh) without digital inputs; · total and partial energy meters (kWh and kvarh) managed by time periods (t1-t2-t3-t4 , WATER (hotcold m3) or remote heating (kWh) meters; · total and partial energy meters (kWh and kvarh
-
Original
EN50470-3 ph a4 250V 2A EN50470-1 RH A4 2A 250V IEC62053-31 kwh meter a4 RS485 EN62053-23 230VAC 115VAC 48VAC/DC

kwh meter circuit diagram

Abstract: 0.001 to 10.00 kWh/kvarh per pulse. Outputs connectable to the energy meters (Wh/varh) TON , contact Working modes Selectable: â'¢ total and partial energy meters (kWh and kvarh) managed by , ) meters or external kWh meter; â'¢ total and partial energy meters (kWh and kvarh) managed by time , selection) and GAS (m3) or WATER (hot-cold m3) or remote heating (kWh) meters or external kWh meter; â'¢ total energy (kWh, kvarh) and GAS, WATER (hot-cold m3) and remote heating meters or external kWh
-
Original
kwh meter circuit diagram 260AC/VDC 230VAC/DC EM2696 30VDC

em24-din

Abstract: EN62053-21 680 100, closed contact 500k, open contact Selectable: · total and partial energy meters (kWh and kvarh) without digital inputs; · total and partial energy meters (kWh and kvarh) managed by time , ) and GAS (m3) or WATER (hotcold m3) or remote heating (kWh) meters; Note Insulation · total and partial energy meters (kWh and kvarh) managed by time periods (t1-t2), W dmd synchronisation , (hot-cold m3) or remote heating (kWh) meters; · total energy (kWh, kvarh) and GAS, WATER (hot-cold m3
Carlo Gavazzi
Original
EM24DINDS210706 em24-din kwh meter 3phase ct kwh meter 3 phase EN62052-31 kwh meter

AC ammeter and ct diagram

Abstract: hobut Pro-Din panel meters. 240° panel meters. kWh meters. Multi-function meters. Protective current , DIN RANGE PANEL METERS DESCRIPTION Available with moving iron or moving coil movements for a.c. or d.c. use, these DIN panel meters have been supplied worldwide and are recognised for their , (72mm & 96mm). · Rugged pivot and jewel movement. · Ammeters, Voltmeters, Frequency Meters, Power , largest independent UK manufacturers of panel meters and associated products. With over 80 years
Howard Butler
Original
D72SD D96SD AC ammeter and ct diagram hobut 240V A.C. to 30V D.C. transformer bs89 digital wattmeter circuit IEC51 D48SD DIN72 DIN48

MH5400

Abstract: TB13A MCH Series Drive 1 - 250 Hp DESCRIPTION The MCH Series variable frequency drive has been specifically designed for HVAC loads such as fans, pumps and cooling towers. The application specific keypad offers easy operation. Features especially useful for fan or pump applications include: · HOA keys to mimic traditional Hand, Off, and Auto functions · PID set point control · Hour and kWh meters · 32 , run time · kWh meter · 8 button keypad has the following functions: - Hand, Off, and Auto select
-
Original
MH575B MH4100B MH5150B MH2250B MH4400B MH4600B MH5400 TB13A siemens rs 1026 TB-13A siemens circuit breaker 200 A 480 v RS-485 MH210B MH410B MH510B MH220B MH420B

hobut

Abstract: D96MD rs 6 A to 50 A New HOBUT products include: · · · · · Pro-Din panel meters. 240° panel meters. kWh , DIN RANGE PANEL METERS DESCRIPTION A vailable w ith m o vin g iron or m o vin g coil m o vem ents , Rugged pivot and jewel movement. Ammeters, Voltmeters, Frequency Meters, Power Factor Indicators , manufacturers of panel meters and associated products. With over 80 years experience in the industry HOBUT , E PANEL METERS · DIGITAL PANEL METERS · HOURS CO U N TE RS · S E LE C TO R SW IT C HE S · PROTE CTIO
-
OCR Scan
D96MD HOBUT ac ammeter D48HZ D72HZ D96MC digital 3 phase voltmeter and ammeter S09002

WM40-96

Abstract: . Remote input disable. Interfacing with watt-hour meters (+kWh, +kvarh, -kWh, -kvarh). 20Hz max, duty , outputs â'¢ Total and partial energy meters (kWh and kvarh) without digital inputs; â'¢ Total and partial energy meters (kWh and kvarh) managed by time periods (t1-t2-t3-t4-t5-t6), W dmd , ) or remote heating (kWh) meters; â'¢ Total and partial energy meters (kWh and kvarh) managed by , tariff selection) and GAS (m3) or WATER (hot/cold/m3) or remote heating (kWh) meters; â'¢ Total
-
Original
WM40-96 NEMA12 RS232 10VDC EN62053-22

star delta starter 4.0 kw to 100 kw

Abstract: kwh meters accessories that can improve energy efficiency, like usage of variable speed drives, kWh meters or intelligent
GE Power Protection
Original
H-1340 star delta starter 4.0 kw to 100 kw star delta starter wiring IEC 60439-1 star delta starter current star delta motor starter 60439-1 B-9000 E/5361/E/EX

how to stop electronic domestic meter

Abstract: kwh meter circuit diagram 20A, 800P/kWh meters respectively 19.975ma and 39.95ma. These two meters can both start at 0.2 , DESCRIPTION BL0932 IC is the main chip widely used for single-phase anti-steal electronic watt-hour meters , electricity power. The watt-hour meters made of BL0932 have better reliability. BL0932 is a special large , shift. Now let us observe, using the anti potential shift logic, the start current of some meters and , electronic watt-hour meter has the constant: 5V, 1600P/Kwh, see its output at Pin8 in following three
Shanghai Belling
Original
BL0931 how to stop electronic domestic meter kwh meter IC 220V ac to 9V dc converter circuit clamp meter circuit diagram electricity meters error curve

230V ac to 36V dc converter circuit

Abstract: pulse rate meter circuit diagram (pulses per kWh) Meters nominal voltage Meters maximum current rating 495 default value, and can be , FEATURES + Provides a single chip solution for energy meters with a + + + + + + + + , for Class 1 AC Watt hour meters Less than 1% error over a dynamic range of 1:1000 Protected against , SAMES SA2002P provides a single chip solution for single phase mechanical counter based energy meters , SA2002P single phase kWh metering integrated circuit generates a pulse rate with a frequency proportional
Sames
Original
230V ac to 36V dc converter circuit pulse rate meter circuit diagram energy meter circuit diagram 230V ac to 36V dc converter circuit diagram 5v stepper motor convert 230v ac to 5v dc without using transformer
Showing first 20 results.