500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
SENSOREVAL Texas Instruments Eval Board Software For Hardware Monitors And Digital Temperature Sensors visit Texas Instruments

k type thermocouple sensor

Catalog Datasheet MFG & Type PDF Document Tags

k type thermocouple sensor

Abstract: Amplifier k thermocouple texas , depending on the temperature range of interest. In this respect, the type K thermocouple with its lower , compensation circuitry for a particular thermocouple type such as the J or K in one IC. These chips replace , lower output of a type K thermocouple. Measuring a Thermocouple over the 1-Wire Figure 4 illustrates , /articles/0102/29/main.shtm JANUARY 2002 SENSOR TECHNOLOGY AND DESIGN The 1-Wire Thermocouple A standard thermocouple can be combined with a lithium ion monitor chip to create a smart sensor that
Dallas Semiconductor
Original

2N2222 transistor

Abstract: Amplifier type t thermocouple 550 R, S 9000 5500 B Any Any Table /. Maximum Gain vs. Sensor Temperature and Thermocouple Type à , thermocouple amplifiers in use have a gain of 110 for type J, 90 for type K, and 220 for type T, then Rj = , circuits in the 2B56, and is a function of thermocouple type and the temperature range (at the sensor) over , Compensation of Other Thermocouple Types: Compensation for type J, K, and T thermocouples is built into the , . For either sensor type, and for all thermocouple types, each millivolt of calibration error will
-
OCR Scan

ABB Pt100 3 wire

Abstract: pt100 temperature sensor circuit diagram -wire Voltage 1) 2 Measuring range Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple , 0.2 K p. a. Thermocouple e. g. type K voltage measurement -100 mV.+1200 mV - 75 mV.+ 75 mV , (100 % humidity with isolated terminals only) Condensation permitted Thermocouple e. g. type K , Pt100 sensor and thermocouple Type of test Burst to signal/ data lines Static disgarge contact
ABB Automation
Original

Resistance characteristic Ni1000

Abstract: ABB Pt100 3 wire - and 4-wire Voltage 1) 2 Measuring range Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T , resistance measurement 0.500 W 0.4000 Thermocouple e. g. type K voltage measurement -100 mV , Thermocouple e. g. type K voltage measurement -100 mV.+1200 mV - 75 mV.+ 75 mV Additional influence of , accordance with NAMUR Thermocouple measurement > 5 k Voltage measurement > 5 k 2 x AI (s) other
ABB Automation
Original

Pt 100 RTD Siemens

Abstract: Thermocouple Type L 0.2 K 0.2 K 0.8 K 0.8 K 0.2 K 0.2 K Thermocouple type C Thermocouple type D 0.+2300 °C (+ 32.+4172 °F) 0.+2300 °C (+ 32.+4172 °F) 0.8 K 0.8 K DIN 43710 Thermocouple type L Thermocouple type U ­100.+ 900 °C (­148.+1652 °F) ­200.+ 600 °C (­328.+1112 °F) 0.2 K 0.2 K , type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R , ) ± 0.2 K resistance measurement 0.400 ± 0.05 0.4000 ± 0.4 Thermocouple e. g. type K
ABB Automation
Original

thermocouple passive sensor

Abstract: Seebeck generator temperature range. For example, a Type K thermocouple has an average sensitivity of approximately 41 uV/°C , sensors are categorized into different calibration types (i.e. type K, type J, etc.) based on types of dissimilar metals which are used to form the thermocouple junction. Based on calibration type, the , taken. This physical property, called the Seebeck effect, is the basis of the thermocouple sensor , design uses a temp sensor on board, why not just use that in place of the thermocouple? That goes back
National Semiconductor
Original

k type thermocouple

Abstract: 60584-2 T E M P E R AT U R E S E N S O R S K type thermocouple probe with lead RPL1-T NEW K type , °C operating temperature range · K type thermocouple · UKAS traceable calibration · -75°C to 250°C operating temperature range · K type thermocouple · UKAS traceable calibration L1 L1 OD L2 , (limited by cable type) K type thermocouple. (Other types available) 316 stainless steel BS EN 60584-2 , +250°C (limited by cable type) K type thermocouple. (Other types available) 316 stainless steel BS EN
-
Original

c1740 transistor

Abstract: C1740 transistor specsheet : Sub-miniature L: Lumberg D: Din C: Cable Tailed B: Bipole E: Lemo/MCX Sensor Type K: Type K thermocouple T: Type T thermocouple X: Thermistor (PST) P: PT100 P K 24 M Example Sequential code , °C 116 to 154°C 160 to 199°C 204 to 260°C Cable ties in pack of 50 Sensor type Type K Type K , *IP23L K Probes with type K and T thermocouple sensors also have mineral insulated. semi-flexible , . SENSOR TYPE Choose a sensor best suited to your needs for measurement range, accuracy and response time
-
Original
c1740 transistor C1740 transistor specsheet C1740 C9001 thermometer comark n9001 thermometer C9011 comark PK32M SK26M AK26M IK26M IT23M IT23L
Abstract: to 95% relative humidity OM-SP1700 SERIES THERMOCOUPLE LOGGER Input Type: thermocouple, type J, K , chart below Thermocouple Accuracy Chart (°C) Temperature Range Point Thermocouple Type J K T E , readily-available thermocouple probes in J, K, T, E, R and S types. Each logger is calibrated during manufacture , accessory current probes Resolution: see thermocouple resolution chart below Input Impedance: >500 K , TEMPERATURE SENSOR (Integral) Sensor: precision calibrated NTC thermistor; 100 K Ohms @25°C Accuracy:  Omega Engineering
Original
OM-SP4000 OM-SP1700-200 OM-SP1700-300 OM-SP1700-500 OM-SP2000 OM-SP4000-1CW

chromel seebeck Table

Abstract: monograph 175 accurate thermocouple circuit is achievable by using the circuit shown in Figure 15. A Type K thermocouple , instrumentation amplifier would be 43.72mV for the combination of the Type K thermocouple offset at 750°C (per , 41.276 TABLE 6: Type K thermocouple output voltage look-up table. All values in the table are in , . Thermocouple Type E J K R S T Range 0° to 1000°C 0° to 760°C 0° to 500°C -50° to , Thermocouple Type Conductors E Application Environments TABLE 1: Common thermocouple types-The
Microchip Technology
Original
chromel seebeck Table monograph 175 IPTS90 MCP601 comparator Golden motor 10kw D2063 AN684 AN679 DS00684A-

ABB KENT-TAYLOR transmitter

Abstract: pt 100 temperature sensor RTD abb MIN SPAN IEC 584-1 Sensor Thermocouple Type B Thermocouple Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type S Thermocouple Type T Thermocouple Type N , INPUT TYPE Connection entry for integrally mounted sensor TERMINAL CONNECTION Thermocouple , °F) 50°C (90°F) 100°C (180°F) DIN 43710 Thermocouple Type L Thermocouple Type U - 100 to + 900 , Thermocouple Type W3 Thermocouple Type W5 INPUT SOURCE Standard IEC 751 / DIN43760 ( = 0.00385) +
-
Original
ABB KENT-TAYLOR transmitter pt 100 temperature sensor RTD abb calibration certificate of k type thermocouple Thermocouple Type L ABB thermocouple calibration procedure for thermocouple AN0239 SS/653T

RS 610-067

Abstract: BS4937 review the type N thermocouple is not merely an For these reasons type K thermocouples are improved , type K but any nickel characteristics of a particular melt. Consequently, based thermocouple. there , K and N but with type N a simple vary from thermocouple to thermocouple. Unknown solution is , type K but are the best combination of elements giving optimum results for a thermocouple based on , formation of silicates on the surface of the wires, these form 4 E15248 Type K, N and J thermocouple
RS Components
Original
BS4937 BS1843 RS 610-067 RS 611-234 150004 158-525

chromel seebeck Table

Abstract: MTS102 - silicon temperature sensor Figure 15. A Type K thermocouple is chosen for this circuit because of its stable Seebeck Coefficient , input of the instrumentation amplifier would be 43.72mV for the combination of the Type K thermocouple , combination of the Type K thermocouple and the thermistor error correction circuitry. The inverting input of , 40.494 40.885 41.276 TABLE 6: Type K thermocouple output voltage look-up table. All values in , % Rhodium) (+) Platinum (-) 0 to 1480 7uV/°C oxidizing, inert Thermocouple Type Conductors
Microchip Technology
Original
MTS102 - silicon temperature sensor second order low pass filter advantage and disadvantages ntc thermistor 10k thermistor ntc characteristic 40k MTS105 RTD CIRCUITS QS-9000

2N2222 transistor

Abstract: k thermocouple amplification circuit diagram DEVICES_Signal Conditioner 2B50 FEATURES Accepts J, K, T, E, R, S or B Thermocouple Types Internally Provided , jumper programmed to provide cold junction compensation for thermocouple types J, K, T, and B, or , compensation. An integral reference junction sensor is provided for direct thermocouple connections, or an external reference sensor (2N2222 transistor) may be used in applications having remote thermocouple termination. Compensating networks for thermocouple types J, K, and T are built into the 2B50. A fourth
-
OCR Scan
2B50B 2N2222 transistor k thermocouple amplification circuit diagram ZB50 trim pot 200k Amplifier type K thermocouple 220V to 12V transformer

pt100 atex

Abstract: AGLF Sensor wire break monitoring in accordance with NAMUR Thermocouple measurement > 5 k Voltage , dependent on the Ex supply unit Resistance 10/11-8.69 EN Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S , 0.4000 Thermocouple e. g. type K voltage measurement -120 mV.+1200 mV - 75 mV.+ 75 mV ± 0.1 K , Sensor wire break detection 3-wire resistance measurement > 35 4-wire resistance measurement > 3.7 k
ABB Automation
Original
NGV220-NO pt100 atex AGLF NGV220-EX ABB Pt100 3 wire agsfd Thermocouple Type K TF202/TF202-E NGV220-E TF202

k type thermocouple

Abstract: thermocouple linearity FEATURES FUNCTIONAL BLOCK DIAGRAM REF APPLICATIONS J or K type thermocouple temperature measurement , AD8495 AD8496 AD8497 ThermoCouple Type J K J K Optimized Temperature Range Ambient , AD8494 AD8495 AD8496 AD8497 Thermocouple Type J K J K Max Error ±2°C ±2°C ±2°C ±2°C , basic connection for the AD849x, with a J type or K type thermocouple input. The AD849x can be , Pretrimmed for J or K type thermocouples Internal cold junction compensation High impedance differential
Analog Devices
Original
AD8495ARMZ k type thermocouple thermocouple linearity AD8495-ARMZ AD8494/AD8495/AD8496/AD8497 AD8494/AD8495/ AD8496/AD8497 10-07-2009-B AD8494ARMZ AD8494ARMZ-R7

AD8495ARMZ-R7

Abstract: Analog Devices, Inc ESD AND OVP A1 SENSE Figure 1. APPLICATIONS J or K type thermocouple temperature , sensing Table 1. Device Temperature Ranges ThermoCouple Type J K J K Optimized Temperature Range , nonlinearity of the thermocouple. Table 7. AD849x ±2°C Accuracy Temperature Ranges Thermocouple Type J K J K , Figure 33 shows an example of a basic connection for the AD849x, with a J type or K type thermocouple , FEATURES Low cost and easy to use Pretrimmed for J or K type thermocouples Internal cold junction
Analog Devices
Original
AD8495ARMZ-R7 Analog Devices, Inc Catalytic Converter MO-187-AA AD8494CRMZ AD8494CRMZ-R7 AD8495CRMZ AD8495CRMZ-R7

k thermocouple amplification circuit diagram

Abstract: 2N2222 transistor ANALOG DEVICES Isolated, Thermocouple Signal Conditioner MODEL 2B50 FEATURES Accepts J, K, T , compensation for thermocouple types J, K, T, and B, or resistor programmed for types E, R, and S. The high , Thermocouple Types Jumper Configurable Compensation J, K, T, or B * Resistor Configurable Compensation R, S , sensor is provided for direct thermocouple connections, or an external reference sensor (2N2222 , thermocouple types Jl, K, and T are built into the 2B50. A fourth compensation (X) may be programmed with a
-
OCR Scan
220V AC to 5V DC transformer Model 2B50B 2B50A thermocouple application AC1218 2B50 2B50IS

MTL 188

Abstract: mtl ANALOG OUTPUT BARRIER THERMOCOUPLE TEMPERATURE TRANSMITTERS Models 2B52 and 2B53 accept a type J, K or T thermocouple input and , Type Select Temperature 01 through 06 Range No. 01 02 03 04 OS 06 Thermocouple Types, J, K , available; order 2B52-CUSTOM or 2B53-CUSTOM and specifYboth thermocouple type and temperature range. CUSTOM modules can provide for thermocouple types J, K, T, E, R, Sand B.There is an additional charge for custom , calibration is desired, the thermocouple type and zero and span temperatures (in °C) must be specified. When
Analog Devices
Original
2B59A MTL 188 mtl ANALOG OUTPUT BARRIER rtd 392 platinum 28serie 4-20 mA 1997 sensor AD590 2B52/2B53 2B57A- 00S27 2B57A-I

AD8496

Abstract: ad8495 FEATURES FUNCTIONAL BLOCK DIAGRAM SENSE APPLICATIONS J or K type thermocouple temperature , AD8495 AD8496 AD8497 ThermoCouple Type J K J K Optimized Temperature Range Ambient , Thermocouple Type J K J K Max Error ±2°C ±2°C ±2°C ±2°C Ambient Temperature Range 0°C to 50 , , with a J type or K type thermocouple input. The AD849x can be configured as a standalone Celsius , Pretrimmed for J or K type thermocouples Internal cold junction compensation High impedance differential
Analog Devices
Original
OVEN* temperature sensor Cold Junction Compensation Linear Thermometer ic thermocouple reference oven temperature sensors measurement of thermocouple response time AD8496ARMZ AD8496ARMZ-R7 AD8496CRMZ AD8496CRMZ-R7 AD8497ARMZ AD8497ARMZ-R7
Showing first 20 results.