NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
CC3000TYPEVKEM Texas Instruments Murata Type VK SimpleLink WiFi evaluation module ri Buy
LTK001ACJ8 Linear Technology IC THERMOCOUPL COMP& KIT 8DIP ri Buy
LTK001CJ8 Linear Technology IC THERMOCOUPL COMP& KIT 8DIP ri Buy

k type thermocouple

Catalog Datasheet Results Type PDF Document Tags
Abstract: T E M P E R AT U R E S E N S O R S K type thermocouple probe with lead RPL1-T NEW K type , operating temperature range · K type thermocouple · UKAS traceable calibration · -75°C to 250°C operating temperature range · K type thermocouple · UKAS traceable calibration L1 L1 OD L2 , (limited by cable type) K type thermocouple. (Other types available) 316 stainless steel BS EN 60584-2 , +250°C (limited by cable type) K type thermocouple. (Other types available) 316 stainless steel BS EN ... Original
datasheet

1 pages,
423.26 Kb

thermocouple length 60584 R type thermocouple wire Thermocouple Type K sensor Thermocouple Thermocouple Simplex type material Thermocouple Type K material j type thermocouple sensor simplex Thermocouple Type K material k type thermocouple sensor 60584-2 k type thermocouple datasheet abstract
datasheet frame
Abstract: identify the different operating conditions when using either a J or K type thermocouple. ITEM , any of the 4 input channels in any configuration. Temperature range K type thermocouple -100 , ) -148 (degF) to 1,112 (degF) Resolution of reading K type thermocouple 0.4 (degC) 0.6 (degF) J type thermocouple 0.3 (degC) 0.4 (degF) K type thermocouple -1,000 to 12,000 -1,480 , separate analog signals from 'K' and/or 'J' type thermocouples. FX Specification PARAMETER ... Original
datasheet

2 pages,
23.29 Kb

FX-4ad k type thermocouple J type thermocouple FX-HSI001A FX-HSI001A abstract
datasheet frame
Abstract: digital panel modules user guide OEM035KCS OEM035KCS 3.5 digit LCD K Type Thermometer Module features Accepts K type thermocouple Factory calibrated in degrees Celsius 12.7mm digit height Cold junction , optional mounting bezel DESCRIPTION The OEM035KCS OEM035KCS is a complete digital thermocouple meter module for measuring temperature from -50 to 1000OC 1000OC from a K type thermocouple. It is factory calibrated and no , ORDERING INFORMATION 3.5 Digit K Type Thermometer module MB501S MB501S Optional Black ABS Mounting Bezel ... Original
datasheet

1 pages,
137.58 Kb

thermocouple OEM035KC accuracy of K type thermocouple OEM035KCS digital tc thermometer thermocouple meter k type thermocouple Accuracy Digital Thermometer LCD 3.5-DIGIT 3.5-DIGIT lcd OEM035KCS abstract
datasheet frame
Abstract: digital panel modules user guide OEM035KC OEM035KC 3.5 digit LCD K Type Thermometer Module features Accepts K type thermocouple Factory calibrated in degrees Celsius 12.7mm digit height Cold junction , optional mounting bezel DESCRIPTION The OEM035KC OEM035KC is a complete digital thermocouple meter module for measuring temperature from -50 to 1000OC 1000OC from a K type thermocouple. It is factory calibrated and no , negative input +5V Power supply ORDERING INFORMATION OEM035KC OEM035KC 3.5 Digit K Type Thermometer module ... Original
datasheet

1 pages,
59.46 Kb

thermometer 351 power meter cold junction MB501 thermocouple Thermocouple Type K data sheet Thermocouple Type K k type thermocouple circuit with thermocouple application OEM035KC Cold Junction Compensation LCD 3.5-DIGIT thermocouple meter OEM035KC abstract
datasheet frame
Abstract: Thermocouple Temperature Sensing Stock Number Data Logger EL-1 Specification WindowsTM 3.1 Control Software Range Temperature ('K' type thermocouple) Stock Number - EL-WIN Easy to install and , Pluggable Links (Link 1) SHORTED A B BLUE On-Board Link (Link 2) OPEN "K" type thermocouple BROWN TEMPERATURE (with thermocouple) A 'K' type thermocouple can be connected directly to the ... Original
datasheet

2 pages,
165.13 Kb

mini voltage data logger 463-394 pH probe 251-1470E datasheet abstract
datasheet frame
Abstract: Range Temperature ('K' type thermocouple) Temperature (internal) Stock Number - EasyLink , Link (Link 2) OPEN SHORTED "K" type thermocouple + + - - 0-20V D.C. BROWN TEMPERATURE (with thermocouple) A 'K' type thermocouple can be connected directly to the EL-2. The range , Compensation For Thermocouple Temperature Sensing WindowsTM 3.1 Control Software Stock Number - EL-WIN ... Original
datasheet

2 pages,
140.48 Kb

Sonnenschein Lithium sl-750 X mini voltage data logger "Humidity Sensor" k type thermocouple Sonnenschein Lithium 2 AA BATTERY BOX datasheet abstract
datasheet frame
Abstract: seconds to 1 per 12 hours. Temperature ('K' type thermocouple) Voltage Stock Number - EasyLink , "K" type thermocouple BROWN TEMPERATURE (with thermocouple) A 'K' type thermocouple can be , Thermocouple Temperature Sensing WindowsTM 3.1 Control Software Stock Number Data Logger Stock ... Original
datasheet

2 pages,
174.97 Kb

lascar EL-1 Maxell pH probe sl-750 Sonnenschein Humidity and Temperature Probe Sonnenschein Lithium sl-750/S C 12 PH diode k type thermocouple Tadiran Batteries "Humidity Sensor" Data Logger Circuit Sonnenschein Lithium sl-750 X datasheet abstract
datasheet frame
Abstract: and K type thermocouple input 3-wire input 17.5 mm modular casing 0 10 VDC output Specifications Type Temperature convertor General characteristics Electrical characteristics Supply , Code 88 950 108 88 950 112 Input PT 1000 PT100 PT100 PT 100 PT 100 J thermocouple K thermocouple , Convertors current-voltage convertor for Millenium II+ input signals PWM-voltage convertor for Millenium II+ output signals Specifications Type Convertor 0-20 mA / 0-10 V Convertor PWM ... Original
datasheet

1 pages,
38.36 Kb

4 wire pt100 convertor PT1000 accuracy DATASHEET PT1000 thermocouple thermocouple pt 100 Thermocouple type J PT100 PT-1000 k type thermocouple millenium PT100 ma output Thermocouple type k PT100 PT1000 datasheet abstract
datasheet frame
Abstract: compensation. The AD849x is optimized to measure and amplify J and K type thermocouple signals for a linear 5 , thermocouple changes by 52 V/°C at 25°C and by 55 V/°C at 150°C. K type thermocouples tend to be much more , Ranges Thermocouple Type J K J K Part AD8494 AD8494 AD8495 AD8495 AD8496 AD8496 AD8497 AD8497 Max Error ±2°C ±2°C , reference pin connected to a K type thermocouple that reads 1 V), the correction procedure is as follows , connected to a K type thermocouple outputs 1 V. Using the 5 mV/°C transfer function, 1 V represents 200°C. ... Original
datasheet

4 pages,
114.58 Kb

320 702/1 diode Amplifier type K thermocouple AN-1087 cold junction Cold Junction Compensation Thermocouple Type K 4937 e 803 AD8496 Thermocouple Type K linearization k type thermocouple sensor Amplifier type t thermocouple AD849x AN-1087 abstract
datasheet frame
Abstract: Pomona ® Model 6374 Temperature Probe For Air/Gas Measurement FEATURES: · Stainless Steel baffle to protect thermocouple. · "K" type thermocouple with mini-connector for use with DMM's · Having temperature measurement capabilities. MATERIALS: Thermocouple ­ "K" Type, Chromel/Alumel Probe Sheath ­ (Outer) Stainless Steel 304, (Inner) Inconel Baffle ­ Stainless Steel 304. Cable ­ AWG #24, Type KX extension wire, insulation gray PVC. Connector Plug ­ Yellow Hytrel 4776 Handle ­ Gray Hytrel 5556. RATINGS: Temperature ... Original
datasheet

1 pages,
29.55 Kb

d6374 chromel alumel 815C k type thermocouple datasheet abstract
datasheet frame

Datasheet Content (non pdf)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2014): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
highly accurate (< ±0.3% accuracy) using a K type thermocouple (supplied). Both meters have a 1999 count
www.datasheetarchive.com/files/maplin/products/20/8/64prodd.htm
Maplin 28/02/2002 7.4 Kb HTM 64prodd.htm
Thermocouple Conditioner and Setpoint Controller Operates with Type K Thermocouple General junction compensates and amplifies a type J or K thermocouple input to derive an internal signal output (10 mV/C) directly from a type J or K thermocouple signal. It can also be used as a stand-alone temperature range recommended for type J thermocouples while the AD597 AD597 AD597 AD597 can accommodate -200C -200C -200C -200C to +1250C 1250C 1250C 1250C type K , or a lower ambient operating temperature is required, either the AD594 AD594 AD594 AD594 (J thermocouple) or AD595 AD595 AD595 AD595 (K
www.datasheetarchive.com/files/analog-devices/doc/productdescriptions/398.html
Analog Devices 2.23 Kb HTML 398.html
Description= Thermocouple Conditioner and Setpoint Controller Operates with Type K Thermocouple device cold junction compensates and amplifies a type J or K thermocouple input to derive an internal voltage output (10 mV/°C) directly from a type J or K thermocouple signal. It can also be used as a ) or AD595 AD595 AD595 AD595 (K thermocouple) should be considered. *Protected by U.S. Patent No. 4,029 includes a thermocouple failure alarm that indicates an open thermocouple lead when operated in the
www.datasheetarchive.com/files/analog-devices/gendesc/389.htm
Analog Devices 05/06/2003 2.3 Kb HTM 389.htm
junction compensates and amplifies a type J or K thermocouple input to derive an internal signal output (10 mV/°C) directly from a type J or K thermocouple signal. It can also be used as a stand-alone Thermocouple Conditioner and Setpoint Controller Operates with Type J Thermocouple General ) or AD595 AD595 AD595 AD595 (K thermocouple) should be considered. *Protected by U.S. Patent No. 4,029 a thermocouple failure alarm that indicates an open thermocouple lead when operated in the
www.datasheetarchive.com/files/analog-devices/doc/productdescriptions/397.html
Analog Devices 2.33 Kb HTML 397.html
device cold junction compensates and amplifies a type J or K thermocouple input to derive an internal voltage output (10 mV/°C) directly from a type J or K thermocouple signal. It can also be used as a Description= Thermocouple Conditioner and Setpoint Controller Operates with Type J Thermocouple ) or AD595 AD595 AD595 AD595 (K thermocouple) should be considered. *Protected by U.S. Patent No. 4,029 includes a thermocouple failure alarm that indicates an open thermocouple lead when operated in the
www.datasheetarchive.com/files/analog-devices/gendesc/388.htm
Analog Devices 05/06/2003 2.39 Kb HTM 388.htm
SPECIAL FUNCTIONS Thermocouple Compensators Home > Special Functions > Thermocouple Compensators > LTK001 LTK001 LTK001 LTK001 - Thermocouple Cold Junction Compensator /JAN S Products Silicon Oscillators Thermocouple Compensators Thermoelectric Cooler Controller Thermocouple Cold Junction Compensator and Matched Amplifier 0.75°C Initial Accuracy (A Version) Extremely Low Warmup Drift Preset Outputs for Type E, J
www.datasheetarchive.com/files/linear/c1010/c1073/p1181/p1181-v1.html
Linear 09/02/2007 7.61 Kb HTML p1181-v1.html
Initial Accuracy (A Version) Extremely Low Warmup Drift Preset Outputs for Type E, J, K, R, S SPECIAL FUNCTIONS Thermocouple Compensators Home > Special Functions > Thermocouple Compensators > LTK001 LTK001 LTK001 LTK001 - Thermocouple Cold Junction Compensator Oscillators Thermocouple Compensators Thermoelectric Cooler Controller Piezo Microactuator Driver Switched Cap Building Blocks LTK001 LTK001 LTK001 LTK001 - Thermocouple Cold Junction Compensator and
www.datasheetarchive.com/files/linear/c1010/c1073/p1181/p1181.html
Linear 21/11/2005 7.25 Kb HTML p1181.html
or 32 channels), the type of thermocouple that is implemented (type J or K), and the housing type FM3312-B310-0000 FM3312-B310-0000 FM3312-B310-0000 FM3312-B310-0000 Fieldbus Module, thermocouple, 12-channel, type K, PROFIBUS interface FM3312-B310-1000 FM3312-B310-1000 FM3312-B310-1000 FM3312-B310-1000 Fieldbus Module, thermocouple, 12-channel, type K, PROFIBUS interface FM3332-B310-0000 FM3332-B310-0000 FM3332-B310-0000 FM3332-B310-0000 Fieldbus Module, thermocouple, 32-channel, type K, PROFIBUS interface FM3332-B310-1000 FM3332-B310-1000 FM3332-B310-1000 FM3332-B310-1000 Fieldbus Module, thermocouple, 32-channel, type K, PROFIBUS interface
www.datasheetarchive.com/files/beckhoff/catalog/english/fieldbus_box/fm3312_fm3332.htm
Beckhoff 10/11/2009 10.86 Kb HTM fm3312_fm3332.htm
Thermocouple Conditioner and Setpoint Controller Operates with Type K Thermocouple Features Low Cost Operates with Type J (AD596 AD596 AD596 AD596) or Type K (AD597 AD597 AD597 AD597) Thermocouples Built-In Ice Point junction compensates and amplifies a type J or K thermocouple input to derive an internal signal output (10 mV/C) directly from a type J or K thermocouple signal. It can also be used as a stand-alone temperature range recommended for type J thermocouples while the AD597 AD597 AD597 AD597 can accommodate -200C -200C -200C -200C to +1250C 1250C 1250C 1250C type K
www.datasheetarchive.com/files/analog-devices/productdescriptions/398.html
Analog Devices 24/03/2005 2.76 Kb HTML 398.html
junction compensator for use with type E, J, K, R, S, and T thermocouples. It utilizes wafer level and thermocouple voltages of 60.9µV/°C (E), 51.7µV/°C (J), 40.3µV/°C (K, T) and 5.95µV/°C (R, S). All outputs are SPECIAL FUNCTIONS Thermocouple Compensators Home > Special Functions > Thermocouple Compensators > LT1025 LT1025 LT1025 LT1025 - Micropower Thermocouple Cold Junction Thermocouple Compensators Thermoelectric Cooler Controller Piezo Microactuator Driver Switched Cap
www.datasheetarchive.com/files/linear/c1010/c1073/p1232/p1232-viewall.html
Linear 21/11/2005 9.57 Kb HTML p1232-viewall.html