NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
1X Magnetoresistive Wheel-Speed Sensor Honeywell Sensing and Control 1X Magnetoresistive Wheel-Speed Sensor, 4.5 Vdc to 16 Vdc supply voltage, rise time (10 % - 90 %) of 1.5 µs max., 1 pulse per pole pair ri Buy
1.5P Gear-Tooth Sensor Honeywell Sensing and Control 1.5P Gear-Tooth Sensor, 2,5 mm minimum tooth, 5,0 mm minimum slot, 3.0° ± 1.25° operate point ri Buy
1.5Q Gear-Tooth Sensor Honeywell Sensing and Control 1.5Q Gear-Tooth Sensor, 2,5 mm minimum tooth, 2,5 mm minimum slot, 0.5° ± 1.25° operate point ri Buy

helium gas sensor module

Catalog Datasheet Results Type PDF Document Tags
Abstract: the flow sensor module. The integral gas feed cannot be installed when the internal gas lines are , filter, capillary tube and flow sensor modules · or a flow sensor module. Electrical Interfaces The , The pressure sensor is located in the sample gas path if hoses are used as the internal gas lines. If stainless-steel tubing is used for internal gas lines the pressure sensor is routed to the , barometric pressure change The pressure sensor is located in the sample gas path. Pressure sensor working ... Original
datasheet

30 pages,
308.22 Kb

gas sensor CO2 electrochemical sensor CO CO Gas sensor galvanized steel thermal conductivity solenoid valve pump ao2 oxygen AO2000-Magnos CALDOS EL3040 Caldos27 oxygen sensor bypass electrochemical gas sensors datasheet EL3000 EL3020 EL3000 abstract
datasheet frame
Abstract: gas path (if applicable) within the AO2060- AO2060-. analyzer module is factory-tested with helium at a , Purge Gas Inlet 1) Purge Gas Outlet 1) Pressure Sensor (AO2060-Caldos17, -Magnos106 1) Electrical , ) Data Sheet ) Purge Gas Inlet 1) Purge Gas Outlet 1) Pressure Sensor Electrical Connections , The actual gas connection layout of a delivered AO2060- AO2060-. analyzer module will be shown in the , The pressure sensor connection should not be joined with the sample gas path. Continued on next page ... Original
datasheet

44 pages,
939.67 Kb

Uras14 manual ABB AO2000 uras HPA-40 Caldos17 Caldos15 ao2060 AO2060-Caldos17 magnos106 AO2040 AO2000 AO2060-Uras14 abb advance optima AO2060- datasheet abstract
datasheet frame
Abstract: an option. Magnos206 The pressure sensor is installed in the gas analyzer as an option. It is , measuring ranges the connection of the pressure sensor and the sample gas outlet are to be connected to , ). Caldos27 The pressure sensor is installed in the gas analyzer as standard. It is connected to a gas port (flame barrier) via an FPM tube as an option. Caldos25 No pressure sensor is installed in the gas analyzer. Information for the Safe and Correct Operation of the Pressure Sensor If ... Original
datasheet

66 pages,
795.95 Kb

CR2032 HPA-40 standard RJ45 female dimension drawing air Oxygen Analyzer Magnos206 CALDOS 17 ex uras26 manual EL3060-Magnos206 Uras26 EL3060-Caldos27 Magnos206 Caldos27 EL3060 EL3060-Uras26 EL3060 abstract
datasheet frame
Abstract: Analyzer Module MultiFID14 NMHC 26 Laser Analyzer Module LS25 28 Electrochemical Oxygen Sensor 32 Pneumatics Module 33 Gas Connections Uras26, Limas11 34 Gas Connections Limas11 , Laser Analyzer Module Each analyzer module consists of the sensor and associated electronics having , · I/O module equipment · Interfaces + Analyzer modules (see pages 6­33) · Gas path design · Gas connections · Type of installation · Analyzer-specific data Analyzer module Analyzer ... Original
datasheet

48 pages,
577.56 Kb

infrared gas analyzer GAS SENSOR for oxygen oxygen sensor bypass gas calibration certificate carbon monoxide ir sensor abb advance optima ZO23 AO2000 MultiFID14 magnos206 Uras26 AO2020 AO2000 abstract
datasheet frame
Abstract: Gas Outlet Housing Purge Gas Outlet Pressure Sensor 1) End-Point Gas Inlet (with pneumatics module , module consists of the sensor and associated electronics having its own processor. The analyzer modules , pneumatics module (see below). The oxygen sensor is always associated with an analyzer module and is controlled and monitored by the latter's sensor electronics components. Pneumatics Module The pneumatics , controlled and monitored by the latter's sensor electronics components. Electronics Module The ... Original
datasheet

52 pages,
933.54 Kb

magnos LIYCY ZO23 abb fid 14 ao2 oxygen Caldos15 CALDOS Magnos17 MultiFID14 Limas11 gas analyzer 590 AO2040 ABB AO2000 AO2040 AO2000 abb ao2040 AO2000 abstract
datasheet frame
Abstract: an unheated platinum sensor inside the gas flow. The heating power required for maintaining the , heated sensor element, which can thus be used to compensate the temperature dependency on gas , Direct measurement of gas mass flow - No additional pressure and temperature compensation required , Factory-calibrated, with (optional) DKD calibration certificate - Process-calibrated with clean gases and gas , (hot-film anemometer) allows the direct determination of mass flow and gas temperature. Taking the standard ... Original
datasheet

28 pages,
1312.02 Kb

FCM2000 Integrated circuits burner MASS flowmeter MOD112 DN100 pressure transducer 100 hPa stainless steel aisi 430 properties DIN EN ISO 5167-1 EN 10204 3.1 fm transmitter 12 KM circuit diagram FMT500-IG G00829 anemometer 41-EN FMT500-IG 41-EN abstract
datasheet frame
Abstract: testing per MIL standard MIL-STD-750 MIL-STD-750, Method 1071( , sensor, TO8 Package, Peltier TEC SPMMicro3020X05 SPMMicro3000: Silicon Photomultiplier, 20µm (8640 microcells), 3mm x 3mm sensor, TO5 Package SPMMicro3020X13 SPMMicro3000: Silicon Photomultiplier, 20µm (8640 microcells), 3mm x 3mm sensor, Ceramic Package, Epoxy Fill SPMMicro3035X08 SPMMicro3000: Silicon Photomultiplier, 35µm (3640 microcells), 3mm x 3mm sensor, TO8 Package, Peltier TEC ... Original
datasheet

6 pages,
698.68 Kb

TO5 package spma4 SPMMicro1020X13 metal detector sensors metal detector sensor MAGNETIC PARTICLE INSPECTION To5 transistor header spmmicro3000 photomultiplier sensor pulse metal detector 4 PIN TO46 package APDS helium gas sensor module MIL-STD-750 MIL-STD-750 abstract
datasheet frame
Abstract: world-leading APD technology in a variety of miniature, 750, Method 1071( , DESCRIPTION SPMMicro1020X08 SPMMicro1000: Silicon Photomultiplier, 20m (848 microcells), 1mmx1mm Sensor , ), 1mmx1mm Sensor, TO46 Package SPMMicro1020X13 SPMMicro1000: Silicon Photomultiplier, 20m (848 microcells), 1mmx1mm Sensor, Ceramic Package, Epoxy Fill SPMMicro1035X08 SPMMicro1000: Silicon Photomultiplier, 35m (400 microcells), 1mmx1mm Sensor, TO8 Package, Peltier TEC SPMMicro1035X18 SPMMicro1000 ... Original
datasheet

6 pages,
455.24 Kb

to18 package T018 MA220 geiger tubes helium sensor 3-pin IR sensor United Detector Technology Photodiodes TO8 socket TO52 package SPMMicro3035x13 pmt amplifier circuit Metal Detector photomultiplier MIL-STD750 MIL-STD750 abstract
datasheet frame
Abstract: certificate EN 10204-3.1.B of helium leakage test of the sensor module Inspection certificate EN 10204-3.1.B , certificate EN 10204-3.1.B of helium leakage test of the sensor module Inspection certificate EN 10204-3.1.B , the sensor module C4 Inspection certificate EN 10204-3.1.B of the pressure test C5 Certificate of , stage according to DIN 25410 Inspection certificate EN 10204-3.1.B of helium leakage test of the sensor , leakage test of the sensor module Inspection certificate EN 10204-3.1.B of the pressure test Certificate ... Original
datasheet

32 pages,
573.46 Kb

han harting catalog DN25 DIN IEC 60068-2-27 ABB 261GC harting catalog han 8U SS/261GC/AC 2600T 261GC/GG/GJ/GM/GN 261AC/AG/AJ/AM/AN SS/261GC/AC abstract
datasheet frame
Abstract: according to DIN 25410 Inspection certificate EN 10204­3.1.B of helium leakage test of the sensor module , gases, steam and liquids. It measures differential pressure and absolute pressure from a single sensor , 2 = mass flowrate = discharge coefficient = velocity of approach factor = gas expansion factor , SS/269CS SS/269CS_4 Density of fluids Gas expansion factor It corrects for density differences between , density of fluids for changes in temperature and/or pressure as follows: The gas expansion factor is ... Original
datasheet

20 pages,
509.89 Kb

269CS pitot sensor Orifice plate nace group marking y1 t4 C0920 harting catalog han 8U venturi meter harting han 8U D-32425 2600T ABB pressure transmitter series 2600T A470 helium gas sensor module SS/269CS 2600T SS/269CS abstract
datasheet frame