Abstract: Application Tooling Checking Terminal Crimp Height or Gaging Die Closure Conversion Guide For Miniature , be made to ensure crimped contact formation is consistent as shown in Figure 3. i A. Crimp Height , in ensuring optimum electrical and mechanical performance of the crimped terminal. The crimp height , the Same Crimp Height 0.13 [.005] (See Table) Max Wire Barrel Flash Section X-X , Crimp Height Flag Receptacle 0.25 [.010] (See Table) Y Max Wire Barrel Flash 0.38 ... Tyco Electronics
Original
datasheet

12 pages,
631.44 Kb

Tyco faston insulated crimp LR7189 faston flag receptacles crimp height faston flag receptacles 635X0 4-0827 DC2-1982 408-9640 Tyco 408-5842 TEXT
datasheet frame
Abstract: Checking Terminal Crimp Height or Gaging Die Closure Force Gage 92­100505 Heavy Duty Miniature , crimped receptacle. The crimp height must be within the dimensions provided in Figure 3. B. Conductor , ] Max Burr Wire Barrel Crimp Height Wire Barrel Flash 0.13 [.005] Max (Refer to Table on , Piggyback Receptacles RECEPTACLE 114-2082 WIRE SIZE (AWG) APPLIED WIRE BARREL CRIMP HEIGHT , Straight 1.96-2.06 [.077-.081] 22 250 Series Flag 14 CRIMP WIDTH (Ref) 1.73-1.83 ... Tyco Electronics
Original
datasheet

14 pages,
749.67 Kb

140-013 408-7432 408-8547 466500-3 565435-5 565435-5 repair 8039 application note 8040 instruction sheet general maintenance for applicators 90166-1 408-7424 408-8040 408-9640 PIGGYBACK 49710 90165-1 7432 faston flag receptacles crimp height AMPOMATOR CLS IV TEXT
datasheet frame
Abstract: FASTON Terminals CAUTION ! 114- 2123 Crimp height dimensions must not be applied directly to , Plus, and Ultra-Fast Plus Tab Series 110/125, 187, 205, and 250 Fully-Insulated FASTON Terminals , ] 250 250 Flag Terminals Figure 4 3.5. Crimp Requirements The terminal must be crimped in the , or flash-over as a result of this testing procedure. B. Crimp Height Because these terminals are fully insulated, crimp height readings cannot be measured over the insulation. Proper crimp height must ... Tyco Electronics
Original
datasheet

15 pages,
261.09 Kb

466778-4 567111-1 567142-1 5672 58268-1 06016 E9071003 AMP crimper 69710-1 408-2095 466778-6 Tyco (AMP) document 408-6976 UL-310 Tyco faston insulated crimp 408-9902 B 722 P Tyco AMP document 408-6976 408-6976 58080-3 466779 TEXT
datasheet frame
Abstract: WIDTH (REF) 1.77 [.070] 2.79 [.110] WIRE BARREL CRIMP HEIGHT +0.05 [+.002] SIZE 250 , Application Specification 114-2079 FASTON* Flag Receptacles with F" -Crimp Feature NOTE , applied crimp height. See Section 5, TOOLING. DO NOT nick, scrape, or cut the wire conductor during the , height must be within the dimension provided in Figure 3. B. Effective Crimp Length For optimum crimp , Must Both Be Visible In This 0.13 [.005] Figure 3 Table) Wire Barrel Crimp Height (See ... Tyco Electronics
Original
datasheet

12 pages,
662.74 Kb

Tyco faston 1338600-1 408-1851 408-7424 06016 49710 567006-3 567768 faston crimp height 565435-5 2082 tyco 114-2036 408-9640 faston flag receptacles crimp height 114-2079 TEXT
datasheet frame
Abstract: for crimp height. For use with miniature style applicators only. (Shown with optional Crimp Quality , applicators Wide range of optional equipment such as tool-less precision crimp height adjust, batch counter , inspection. It measures the crimp height of each termination, and evaluates the quality of each crimp. If a , of terminal without the need for frequent changeovers of applicators or adjustment of crimp height , [610] Height - 18 [457] Weight - 250 lb [113 kg] Electrical - 120 to 220 VAC, 50 or 60 Hz (217600 ... Tyco Electronics
Original
datasheet

6 pages,
246.38 Kb

Tyco faston insulated crimp AMP TYCO PLATFORM CRIMP TOOL crimp force faston 250 crimp height faston crimp height 296059 smema specifications smema control faston 110 board mount tabs Crimping micro applicator AMP UK 45 smema 59824-1 Tyco Amp faston flag receptacles crimp height AMPOMATOR CLS IV TEXT
datasheet frame
Abstract: Crimp Area Insulation 250-Series Fully-Insulated PIDG FASTON Receptacle (Typ) Color-Coded Insulation 250-Series PIDG FASTON Tab (Typ) Figure 1 2. REFERENCE MATERIAL 2.1. Revision Summary S , Corporation Rev A PIDG FASTON Tabs and Fully-Insulated Receptacles 114-13076 B. Crimp Height Procedure Because these contacts have insulated wire barrels, crimp height readings cannot be measured , Crimp Height or Gaging Die Closure Force Gage 92­100505 Hand Crimping Tool 90276­2 Miniature ... Tyco Electronics
Original
datasheet

11 pages,
587.21 Kb

408-7424* figure 6 faston 250 crimp height extraction tools tyco AMP crimper 56720 csa LR7189 E66717 59824-1 408-9640 59824-1 Tyco Amp Tyco 408-7424 7432 Tyco faston insulated crimp tyco crimp height chart for 24 awg wire crimp 408-7424 58433-3 general maintenance for applicators faston crimp height 59824-1 solder crimp height 408-7424 tyco crimp height chart TEXT
datasheet frame
Abstract: WIDTH CRIMP HEIGHT INSULATION BARREL CRIMP WIDTH 6.35 [.250] SERIES 4.06-5.33 [.160-.210 , Action Hand Tool 189508-1 Checking Terminal Crimp Height or Gaging Die Closure Force Gage 92-100505 , WIRE BARREL CRIMP WIDTH CRIMP HEIGHT INSUL BARREL CRIMP WIDTH 9.52 [.375] SERIES 12 10 8 , BARREL CRIMP WIDTH 2.16-3.18 [.085-.125] (2) 16 CRIMP HEIGHT 5.1-6.1 [.200-.240 , INSULATION DIAMETER STRIP LENGTH 114- 2025 CRIMP HEIGHT INSULATION BARREL CRIMP WIDTH WIRE ... Tyco Electronics
Original
datasheet

13 pages,
221.13 Kb

114-2025 408-7424 408-7432 46633 faston 250 crimp height LR7189 tyco crimp height chart Tyco faston 354500-1 tyco pull force chart TEXT
datasheet frame
Abstract: Checking Terminal Crimp Height Gaging Die Closure Hand Crimping Tool 90246-1 Crimping Die Assemblies , Receptacle Contacts 114-1002 D. Crimp Height Because these contacts are insulated, crimp height readings cannot be measured over the insulation. Therefore, to check for proper crimp height, a piece of , solder must be as stated in Figure 3. The height of the crimped solder must be checked against the crimp , .). CAUTION Crimp height dimensions must not be applied directly to the contact. Applying crimp ... OCR Scan
datasheet

14 pages,
314.78 Kb

Tyco faston insulated hand crimp 408-7278 59824-1 solder crimp height 187 series faston tab bellmouth 567200-2 59824-1, 408-7424 818380-1 59824-1 Tyco Amp amp 408-1559 TEXT
datasheet frame
Abstract: Corporation Rev D PIDG FASTON Receptacle Contacts 114- 1002 CRIMP HEIGHT INSPECTION WIRE SIZE , requirements for application of PIDG FASTON receptacle contacts. The contacts are available in Series 250 , 90185-1 Checking Terminal Crimp Height Gaging Die Closure Hand Crimping Tool 90246-1 Crimping Die , Corporation 3 of 13 PIDG FASTON Receptacle Contacts 114- 1002 3.3. Crimp Requirements NOTE , . See Figure 3. D. Crimp Height Because these contacts are insulated, crimp height readings cannot ... Tyco Electronics
Original
datasheet

13 pages,
245.5 Kb

59828-1 amp pidg CRIMPING E-66717 59824-1 solder crimp height 408-2823 408-7424 Tyco faston 59824-1 pull test 90185-1 108103 408-1559 checking terminal crimp height 408-7424 408-7278 59824-1 565435-5 59824-1 Tyco Amp 567200-3 567200-2 TEXT
datasheet frame
Abstract: Terminal Crimp Height Gaging Die Closure Force Gage 92-100505 For Testing FASTON Terminals Miniature , FASTON Receptacle Contacts 114- 13047 B. Crimp Height Procedure Because these contacts are fully , AWG) Mating End (250- Series) Insulation Barrel Yellow Budget FASTON Receptacle Contact , [.328-.296] COLOR CODING CRIMP HEIGHT (SOLDER DIAMETER) 3.18 [.125] 18 16 14 12 10 2.92 , [.250] 6 35 [ 250] POUNDS 8 57.8 13 89 RED NEWTONS 35.6 22 20 CRIMP PULL ... Tyco Electronics
Original
datasheet

11 pages,
251.98 Kb

59824-1 Tyco Amp 59824-1, 408-7424 59828-1 crimp dimension tolerance FASTON 408-7432 HAND TERMINAL CRIMPING TOOL tyco ELT 406 408-2823 567200-2 59824-1 pull test 408-2822 8082 codes crimp 408-7424 tensile strength crimping pull test faston crimp height Tyco 408-7424 408-7432 instructions 8082 UL-310 pull force requirements 408-7424 TEXT
datasheet frame

Archived Files

Abstract Saved from Date Saved File Size Type Download
No abstract text available
/download/56556195-592510ZC/price-32.zip ()
NEDIS 28/02/2001 1330.97 Kb ZIP price-32.zip
No abstract text available
/download/70930934-592513ZC/price-36.zip ()
NEDIS 27/02/2001 1382.44 Kb ZIP price-36.zip
No abstract text available
/download/40257067-592514ZC/price-37.zip ()
NEDIS 27/02/2001 1404.5 Kb ZIP price-37.zip
No abstract text available
/download/36597836-592511ZC/price-33.zip ()
NEDIS 28/02/2001 1229.25 Kb ZIP price-33.zip
No abstract text available
/download/29812670-592509ZC/price-31.zip ()
NEDIS 28/02/2001 1217.84 Kb ZIP price-31.zip
No abstract text available
/download/34406263-592512ZC/price-34.zip ()
NEDIS 28/02/2001 1229.15 Kb ZIP price-34.zip
No abstract text available
/download/2367491-592498ZC/price-06.zip ()
NEDIS 01/03/2001 2236.65 Kb ZIP price-06.zip
No abstract text available
/download/59539157-592504ZC/price-11.zip ()
NEDIS 28/02/2001 1026.63 Kb ZIP price-11.zip
No abstract text available
/download/4636711-592506ZC/price-13.zip ()
NEDIS 28/02/2001 1026.63 Kb ZIP price-13.zip
No abstract text available
/download/38266838-592491ZC/price-00.zip ()
NEDIS 28/02/2001 1026.63 Kb ZIP price-00.zip