NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
LS2D3N Honeywell Sensing and Control Series HDLS Stainless Steel Non Plug-in: Top Roller Plunger; 1NC Direct-Acting; 0.75 in - 14NPT conduit ri Buy
LS2A4LX-FP Honeywell Sensing and Control Series HDLS Stainless Steel Non Plug-in: Side Rotary - Lever Not Included; 2NC 2NO Double-Pole, Double Throw, Snap-Action, Double-Break; 12-foot Cable ri Buy
LS2A4KC Honeywell Sensing and Control Series HDLS Stainless Steel Non Plug-in: Side Rotary - Lever Not Included; 1NC 1NO Single-Pole, Double Throw, Snap-Action, Double-Break; 6-foot Cable ri Buy

effect of magnetic field on stainless steel

Catalog Datasheet Results Type PDF Document Tags
Abstract: Stainless steel electronics housing ­ Wide selection of materials 5. Burnout current flexibility (Under , bracket: 304 stainless steel. Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm , steel 316 stainless steel 316 stainless steel Notes: Sensor O-rings: Viton Availability of above , Description Note Extra SS tag plate Stainless steel elec. housing Coating of cell None , number can be engraved on standard stainless steel name plate. If extra tag plate is required, select ... Original
datasheet

6 pages,
103.15 Kb

SCS14 NE43 MR-01-75 G5121 1450377PSI CISPR16-2 ASTM nut and bolt ASTM A193 ASTM A194 2H datasheet abstract
datasheet frame
Abstract: hermetically sealed stainless steel housing, designed to meet the requirements of aerospace, ordnance, marine , or low output, depending on the sensor application. Features : l Magnetic field sensing l Small , used to detect magnetic fields passing in front of the sensing face. Once a target is detected, a , as actuators Hall Magnet High High Limited Stainless steel Current sinking, Normally open , fuels Sea level to + 21,212 m -54 to +100° C Stainless steel Special Features : EMI resistance ... Original
datasheet

3 pages,
108.93 Kb

skydrol 200FW 211FW10-4 211FW10-R 212FW10-4 101MG7 HALL 550 sensor MICRO SWITCH FREEPORT illinois MIL-STD-810-B 212FW10-R datasheet abstract
datasheet frame
Abstract: On presenting the actuator to the switch, the high intensity magnetic field from the actuator , designed to be installed so that when a guard door is opened, the action of the magnetic actuator being , The GS1 is housed in a stainless steel or brass housing. The GS2 offers the same characteristic as , more information on the EX version of the Ferrogard GS2. Operating Distance ­ Break GS1 GS2 23mm , GS1 Brass 0.75 mm2 (18AWG 18AWG) 2 wire Grey PVC Jacket OD 6mm (0.24in) Stainless Steel 0.75 mm2 (18AWG 18AWG ... Original
datasheet

4 pages,
81 Kb

GuardMaster safety switch GuardMaster CONTROL UNIT ISO14119 NEC field effect Catalogue sliding door GS1 QQ3 A0205 440N-H02047 440n Allen-Bradley en60204-1 GuardMaster Catalogue SAFETY SWITCH ferrogard gs2 GuardMaster EN954-1 ISO13849-1 EN954-1 abstract
datasheet frame
Abstract: SCREWS Due to redirection of the magnetic field, the retraction force and release voltage decrease when screws constructed from a magnetic material (steel, etc.) are used for mounting of the plunger. Yoke Straight Magnet Steel screw The magnetic field is redirected along the screws and away from the , following shapes. For metal pins: rounded-head pin 2.1 2. EFFECT OF NEARBY MAGNETIC FIELDS TDK , in excess of 3.5N is possible (ON type). · Can be used as a mechanical component in small scale ... Original
datasheet

6 pages,
111.93 Kb

pull type solenoid coils MAGNETIC HEAD circuit audio stereo MAGNETIC HEAD circuit 7 pin MAGNETIC HEAD circuit audio MAGNETIC HEAD Armature Voltage control MAGNETIC HEAD circuit audio 2002/95/EC 2002/95/EC abstract
datasheet frame
Abstract: 5-digit LCD meter with engineering unit ­ Stainless steel electronics housing ­ Wide selection of , for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on , on standard stainless steel name plate. If extra tag plate is required, select "Yes". 7 , digit code "1", "2", "3". In case of stainless steel bolt with 5th digit code "3", static pressure , for 6th digit code 3, 5, 6, 8. Temperature effect: Effects per 28°C change between the limits of ­ ... Original
datasheet

12 pages,
144.49 Kb

teflon gasket ASTM A193 bolts M10 bolts M10 different materials date sheet of 10th class G5121 MR-01-75 NE43 33J 4KV ASTM nut and bolt 22J 1KV fkc fuji datasheet abstract
datasheet frame
Abstract: They operate on the principle of sensing magnetic fields, so they are essentially immune to dust, oil , is mounted on a shaft and spun past a suitable magnetic pickup. The Hall effect sensor element in , to work together for a wide variety of targets, the need for magnetic engineering on the part of , passes in front of the sensor, the magnetic field drops. By setting a suitable threshold level, the , spacing. Measuring the magnetic field gradient at the face of the sensor, however, provides an ... Original
datasheet

5 pages,
130.45 Kb

CHERRY VN101501 hall effect sensor for measure above 10 hall sensor field measuring GS100501 hall effect sensor for measure magnetic pickup Comparison of stainless steels opto-interrupters magnetic flow meter circuit diagram hall effect sensor ignition magnetic speed sensor circuit diagram datasheet abstract
datasheet frame
Abstract: magnetic field, as illustrated in Figure 1. In metals, this effect is very small and very difficult , effect speed sensor. The ring magnet is mounted on a shaft and spun past a suitable magnetic pickup. , need for magnetic engineering on the part of the user has been largely eliminated. Two problems are , field as seen by the sensor element. When a valley passes in front of the sensor, the magnetic field , principle of sensing magnetic fields, so they are essentially immune to dust, oil and other sources of ... Original
datasheet

5 pages,
165.62 Kb

VN101501 HE645 hall effect shunt GS100501 magnetic pickup hall effect sensor ignition HE6450 magnetic pickup speed sensor datasheet abstract
datasheet frame
Abstract: USE OF PLUNGERS 2. EFFECT OF NEARBY MAGNETIC FIELDS TDK plungers are magnetic actuators that utilize , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Yoke Steel screw The magnetic field is redirected along the screws and away from the movable , component) within the drive coil bobbins (ON type). · Electric power consumption can be reduced due use of , , DVD-ROM drives. · Card lock for magnetic card readers. · Brake for prevention of tape wrap-up during , magnetic materials such as iron, stainless, etc. 0 0.5 1 1.5 I (mm) I ... Original
datasheet

5 pages,
211.22 Kb

pull type solenoid coils MAGNETIC HEAD circuit MA-307-26 MA-201-7 C131 Armature Voltage control datasheet abstract
datasheet frame
Abstract: : 1. Operating Air Gap is dependant on magnetic properties of target. A high grade A2 steel target was , 65035 Hall effect stud sensor detects the presence of a ferrous material and provides a switched output. , removed. The sensor is built into a threaded stainless steel tube and contains a single element Hall , 65035 HIGH RELIABILITY BACK BIASED HALL EFFECT STUD, SWITCHING OUTPUT WITH CABLE MICROPAC , Wide operating temperature range -55 ºC to +150ºC High magnetic sensitivity Wide operating voltage ... Original
datasheet

3 pages,
212.07 Kb

schematic hall proximity sensor RS103 CS115 CS114 RTCA DO-160 waveform of hall effect sensor MIL-STD-461E, RS103 datasheet abstract
datasheet frame
Abstract: stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe , stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: Cell's surface is , Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None Note3 , D F Y B C E M N P Q Costomer tag number can be engraved on standartd stainless steel , LCD meter with engineering unit ­ Stainless steel electronics housing 5. Burnout current flexibility ... Original
datasheet

8 pages,
136.03 Kb

NE43 MR-01-75 G5121 ASTM Bolt M12 ASTM nut and bolt ASTM A194 2H ASTM A194 4l datasheet abstract
datasheet frame

Datasheet Content (non pdf)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2014): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
No abstract text available
www.datasheetarchive.com/download/11730034-169555ZC/tempsens.zip (sens.xls)
Infineon 07/09/2000 50.43 Kb ZIP tempsens.zip
No abstract text available
www.datasheetarchive.com/download/58958483-169544ZC/pressens.zip (sens.xls)
Infineon 07/09/2000 54.34 Kb ZIP pressens.zip
No abstract text available
www.datasheetarchive.com/download/53998691-169539ZC/magnsens.zip (sens.xls)
Infineon 07/09/2000 50.36 Kb ZIP magnsens.zip
No abstract text available
www.datasheetarchive.com/download/11007971-571026ZC/daq1b.ppt
National Instruments 15/07/1998 1140 Kb PPT daq1b.ppt
No abstract text available
www.datasheetarchive.com/download/65302873-16676ZD/content7_e.xml
Epcos 22/10/2002 106.36 Kb XML content7_e.xml
No abstract text available
www.datasheetarchive.com/download/86555338-16680ZD/content9_e.xml
Epcos 22/10/2002 97.62 Kb XML content9_e.xml
No abstract text available
www.datasheetarchive.com/download/70932984-16612ZD/content.xml
Epcos 22/10/2002 500.99 Kb XML content.xml
capacitance. Figure 5: Effect of cable capacitance on signal driving 100 1-Wire devices. The 100m cable adds shows the effect charging the parasite power capacitance has on different numbers of 1-Wire devices at voltage of Q1, the transistor begins to turn on. The effect of the transistor turning on with C5 across again turns on the half-wave rectifier diode. This concept of "stealing" power from the data line by a dimes. The two-piece stainless steel package acts as both protective housing and electrical connection
www.datasheetarchive.com/files/maxim/0001/tb1.htm
Maxim 02/05/2002 96.27 Kb HTM tb1.htm