500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
LM317KSTEELSTEEL/NOPB Texas Instruments IC VREG ADJUSTABLE POSITIVE REGULATOR, Adjustable Positive Single Output Standard Regulator
LM117KSTEEL/NOPB Texas Instruments 1.2 V-37V ADJUSTABLE POSITIVE REGULATOR, MBFM2, GREEN, METAL CAN, TO-3, 2 PIN
LM117K STEEL Texas Instruments Extended Temperature 1.5A Adjustable Linear Regulator with Short Circuit Protection 2-TO-3 -55 to 150
LM117K STEEL/NOPB Texas Instruments Extended Temperature 1.5A Adjustable Linear Regulator with Short Circuit Protection 2-TO-3 -55 to 150
LM117KSTEEL Texas Instruments 1.2 V-37V ADJUSTABLE POSITIVE REGULATOR, MBFM2, METAL CAN, TO-3, 2 PIN
LM109K STEEL Texas Instruments Extended Temperature 1A 5V Output Linear Regulator / LDO 2-TO-3 -55 to 150

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : KIT-HALL-EFFECT-SWITCHES Supplier : Infineon Technologies Manufacturer : Avnet Stock : - Best Price : - Price Each : -
Shipping cost not included. Currency conversions are estimated. 

effect of magnetic field on stainless steel

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: designed to be installed so that when a guard door is opened, the action of the magnetic actuator being , . The GS1 is housed in a stainless steel or brass housing. The GS2 offers the same characteristic as , more information on the EX version of the Ferrogard GS2. Operating Distance ­ Break GS1 GS2 23mm , GS1 Brass 0.75 mm2 (18AWG) 2 wire Grey PVC Jacket OD 6mm (0.24in) Stainless Steel 0.75 mm2 (18AWG , Stainless Steel or Brass Mounting Any Position M3 mounting security screws included. Weight (not -
Original
EN1088 AS4024 ferrogard 440N-G02049 440N-G02048 440N-A02057 FERROCODE EN60204 EN954-1 ISO13849-1 IEC/EN60204-1 NFPA79 ISO14119
Abstract: SCREWS Due to redirection of the magnetic field, the retraction force and release voltage decrease when screws constructed from a magnetic material (steel, etc.) are used for mounting of the plunger. Yoke Straight Magnet Steel screw The magnetic field is redirected along the screws and away from the , following shapes. For metal pins: rounded-head pin 2.1 2. EFFECT OF NEARBY MAGNETIC FIELDS TDK , in excess of 3.5N is possible (ON type). · Can be used as a mechanical component in small scale -
Original
MAGNETIC HEAD circuit audio Armature Voltage control audio MAGNETIC HEAD MAGNETIC HEAD circuit MAGNETIC HEAD circuit 7 pin MAGNETIC HEAD circuit audio stereo 2002/95/EC
Abstract: (6.35mm) stainless steel shaft and stainless steel pivot pins offer impressive strength and corrosion , generation of small magnetic joysticks and is meant as a replacement for older inductive coil joysticks , (6.35mm) diameter, stainless steel Handle: thermoset phenolic (model 100) Boot & Gasket: thermoplastic , Magnetic Joysticks PRODUCTS HFX Panel Mount Magnetic Joystick Information and Specifications , non-contacting Hall Effect sensors and solid magnets in a small, compact housing. A durable rubber boot and CH Products
Original
wheelchair joystick circuit automated wheelchair circuit HFX Magnetic Joystick 2 axis joystick inductive joystick circuit HFX-11D11
Abstract: USE OF PLUNGERS 2. EFFECT OF NEARBY MAGNETIC FIELDS TDK plungers are magnetic actuators that utilize , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Yoke Steel screw The magnetic field is redirected along the screws and away from the movable , component) within the drive coil bobbins (ON type). · Electric power consumption can be reduced due use of , , DVD-ROM drives. · Card lock for magnetic card readers. · Brake for prevention of tape wrap-up during , magnetic materials such as iron, stainless, etc. 0 0.5 1 1.5 I (mm) I -
Original
C131 MA-201-7 MA-307-26 pull type solenoid coils
Abstract: . Schematic description of the Hall effect 204 Selection guide electronic magnetic switches in smooth , from Bernstein are based on two different physical operating principles: the Hall effect and , non-sensitivity to mechanical influences. MR sensor technology The prime elements of MR sensors are magnetic field dependent, ferromagnetic thin-film resistors. The base material of such a unit is made from , , speed of rotation, position and magnetic fields. Detecting very low magnetic fields is possible with Altech
Original
MA-70 MA-62 MA-55 MA-52 MA-61 MA-63
Abstract: unshielded ones. From this size, almost all lines of magnetic field run from the sensor to the target , measuring principle is based on the extraction of energy from an oscillating circuit. This energy is , with an alternating current, causing a magnetic field to form around the coil. If an electricallyconducting object is placed in this magnetic field, eddy currents are induced which form a field according to Faraday's induction law. This field acts against the field of the coil, which also causes a MICRO-EPSILON
Original
32VDC DT3301 PSC30 DT3300 MBC300 ESC30
Abstract: diameter of the sensor for unshielded ones. From this size, almost all lines of magnetic field run from the , on the extraction of energy from an oscillating circuit. This energy is required for the induction of , current, causing a magnetic field to form around the coil. If an electricallyconducting object is placed in this magnetic field, eddy currents are induced which form a field according to Faraday's induction law. This field acts against the field of the coil, which also causes a change in the impedance of the MICRO-EPSILON
Original
coil eddy distance eddy current Sensor water level inductive sensor DT330 MCT304-SM MCT304 Y9761123-D010117MLO
Abstract: diameter of the sensor for unshielded ones. From this size, almost all lines of magnetic field run from the , on the extraction of energy from an oscillating circuit. This energy is required for the induction of , current, causing a magnetic field to form around the coil. If an electricallyconducting object is placed in this magnetic field, eddy currents are induced which form a field according to Faraday's induction law. This field acts against the field of the coil, which also causes a change in the impedance of the MICRO-EPSILON
Original
PS2010 PS300/12/5 240VAC 12VDC 230VAC 24VDC
Abstract: on the extraction of energy from an oscillating circuit. This energy is required for the induction of , current, causing a magnetic field to form around the coil. If an electricallyconducting object is placed in this magnetic field, eddy currents are induced which form a field according to Faraday's induction law. This field acts against the field of the coil, which also causes a change in the impedance of the , phase position of the sensor coil. electromagnetic field sensor housing coil eddy currents MICRO-EPSILON
Original
M16X0 Y9761123-D060129DGO
Abstract: -digit LCD meter with engineering unit ­ Stainless steel electronics housing ­ Wide selection of materials , % of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on , : In case of 11th code "D, E, L, F, M, N, P", PVC armored stainless steel. In case of 11th code "Q, R , stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe , mounting bracket> Capillary Mounting bracket Armor of capillary 1.5 m 304 Stainless steel PVC (*5 Fuji Electric
Original
JIS-10K-100A DN100 PN16 KB910 JIS-10K NE43 CISPR16-1 CISPR16-2 EN61326 IEC61000-4-2 1000MH IEC61000-4-3
Abstract: has unique features, and choice of technology must be based on application needs. The features chart , aircraft, ordnance, marine, mass transit, high performance industrial equipment Stainless steel housing , Position Sensors Severe Environment Proximity Sensors 200FW Series FEATURES Hall effect, magnetic , equipment Stainless steel housing, thick wall construction for effective shielding Leadwire or connector , Stainless steel Housing Stainless steel Stainless steel 0.4 V Current Consumption, max Honeywell
Original
390FW04A-10 405FW504-B 330FW04A-1 honeywell sensor 405fw504-b 405fw MIL-W-22759 112FW12-R1 30FW04A-1 15-5PH MIL-STD-704 MIL-STD-461
Abstract: stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe , stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: Cell's surface is , > Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None , -digit LCD meter with engineering unit ­ Stainless steel electronics housing 5. Burnout current flexibility , 0.05+0.05 % of span Span Stability: ± 0.1% of upper range limit (URL) for 3 years. Temperature effect Fuji Electric
Original
ASTM A194 4l ASTM A194 2H ASTM nut and bolt FKG4 ASTM Bolt M12 10th class date sheet 1/4-18NPT 1/2-14NPT 7/16-20UNF
Abstract: calibrated span per 1V RFI effect: Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field , indicator option 4.5kg for stainless steel housing option 1.0kg per 50mm extension of diaphragm , : An extra stainless steel tag with customer tag data is wired to the transmitter. Coating of cell , 200 Extra SS tag plate Stainless steel elec. housing Coating of cell None None None , stainless steel nut High accuracy type Low temperature effect type H+J Note 2: (*2 Fuji Electric
Original
JIS-10K-40A JIS-10K-50A JIS-30K-40A JIS-30K-50A JIS-20K-40A JIS-20K-50A flange size JIS-10K-50A flange size JIS-20K-50A
Abstract: hermetically sealed stainless steel housing, designed to meet the requirements of aerospace, ordnance, marine , or low output, depending on the sensor application. Features : l Magnetic field sensing l Small , used to detect magnetic fields passing in front of the sensing face. Once a target is detected, a , as actuators Hall Magnet High High Limited Stainless steel Current sinking, Normally open , fuels Sea level to + 21,212 m -54 to +100° C Stainless steel Special Features : EMI resistance Honeywell
Original
101MG7 212FW10-R 212FW10-4 211FW10-R 211FW10-4 MICRO SWITCH FREEPORT illinois MIL-STD-810-B HALL 550 sensor MIL-STD-810B
Abstract: -digit LCD meter with engineering unit ­ Stainless steel electronics housing ­ Wide selection of materials , (standard), or 316 stainless steel (SCS14 per JIS G5121), as specified. Capillary: In case of 11th code "D, E, F, L, M, N, P", PVC armored stainless steel. In case of 13th code "Q, R, S, T, V, W, X , 0.8kg for indicator option 4.5kg for stainless steel housing option 1.5kg per 50mm extension of , : An extra stainless steel tag for customer tag data is wired to the transmitter. Coating of cell Fuji Electric
Original
10K80A CISPR-16 difference between 304, 316 and 316L FCX dp cell JIS-10K-80A PN40 IEC61000-4-8 IEC61000-4-4 IEC61000-4-5 IEC61000-4-6
Abstract: Stainless steel electronics housing ­ Wide selection of materials 5. Burnout current flexibility (Under , Mounting bracket: 304 stainless steel. Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On , of the maximum span for better performance. 4 0 Wetted cell body 316 stainless steel 316 , : (*2) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate , Communicator ) ± 0.2% of upper range limit (URL) for 3 years. Temperature effect: Effect per 28 Fuji Electric
Original
ASTM A193 1450377PSI NACE MR-01-75
Abstract: " diameter pole piece is epoxy encapsulated in a stainless steel case measuring 0.75" Dia. x 3.5" L and is , . CONSTRUCTION: Epoxy Encapsulated 0.25" dia. sensor in 0.750" ±0.005" dia. #304 stainless steel case. PSAC application depends on the size, material, and spacing of the targets being sensed and the sensing distance , . position. When an external mass of magnetic material (target) approaches the sensing area, it shunts away a part of this field, causing the switch contact to transfer to the N.O. position. The distance, at Red Lion Controls
Original
LP0019
Abstract: either anodized aluminum or stainless steel which provides low specific application requirements. The sensing technique for magnetic field susceptibility. Our standard in-line amplifiers and these accelerometers is based on piezoresistive technology. Instrumentation may be used with the JTF Series , at 0 Hz · Low magnetic field due to case material Model JTF PERFORMANCE SPECIFICATIONS , , AG111 Anodized Aluminum Non-linearity and hysteresis ±1 % full scale Stainless steel Honeywell
Original
AG112 AG113 10-32 unf bolt 008727-1-EN
Abstract: specification Cylinder body _ Non magnetic stainless steel Piston rod _ Non magnetic stainless steel BS 304S11/12 SAE 304L Seals _Nitrile End caps , activated magnetically. When the sensor is subjected to the influence of a magnetic field the contacts close , pivoted 0.85 X L.E.D inside this off one when fitted Magnetic field 0 on on off SL , °C Note: Dimension A is the distance from the end cap face to the centre of the magnetic field in the end RS Components
Original
relay ZF 142 012 RP43P BS4862 303S21 TB 1226 EN xd 402 mf RP52P
Abstract: '™ For Global Switches â'" â'˜Prepared for global switches with magnetic piston and stainless steel , switches with magnetic piston and stainless steel tube.â'™ For Global Switches and reduced pressure , +250°F size) with either carbon steel or stainless steel tube; (+121°C) (depending on seal class). , change in polarity of the magnetic field as a piston with magnet moves through the cylinder. LED , format the cylinder tube. The switch will detect the polarity of the residual magnetic field created by Parker Hannifin
Original
HY04-AC1132-4/NA
Showing first 20 results.