500 MILLION PARTS FROM 12000 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
HD3SS3220IRNHR Texas Instruments 10Gbps USB 3.1 Type-C 2:1 Mux with DRP Controller 30-WQFN -40 to 85 ri Buy Buy
HD3SS3220RNHT Texas Instruments 10Gbps USB 3.1 Type-C 2:1 Mux with DRP Controller 30-WQFN 0 to 70 ri Buy
HD3SS3220RNHR Texas Instruments 10Gbps USB 3.1 Type-C 2:1 Mux with DRP Controller 30-WQFN 0 to 70 ri Buy Buy

drp 240-1 Datasheet

Part Manufacturer Description PDF Type Ordering
DRP-240-1 Lambda Electronics Over 600 obsolete distributor catalogs now available on the Datasheet Archive - Industrial DIN Rail Power Supply, 24V Output, 240W
ri

1 pages,
92.34 Kb

Scan Buy
datasheet frame

drp 240-1

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Agency Approvals Non Periodic Overvoltage Lambda's 2 Year Warranty Lambda's new NES & DRP Series, Din , brown outs, typical of factory settings, the NES & DRP Series power supplies are in compliance with , NES & DRP Series power supplies feature worldwide safety approvals including: UL1950 UL1950, EN60950 EN60950 and the CE Mark. Through Lambda's advanced design techniques and global support, the NES & DRP Series power , (47-63Hz). DRP: -1 Model - Single Phase 110/230VAC 110/230VAC, 47-63HZ 47-63HZ. -3H Models - "Three Phase 480VAC 480VAC, 47- 63Hz ... OCR Scan
datasheet

2 pages,
73.54 Kb

RAIL en50022 DRP-480-1 EN55022-B 24v to 230vac inverter circuit EN60950and overcurrent inverter protection IEC1000-4 NES60-24 drp-120-1 DRP480-1 en50022 drp-240-1 EN6095 LAMBDA drp drp 240-1 ORP12 TEXT
datasheet frame
Abstract: Warranty Low Profile or Less Panel Space Lambda's new NES & DRP Series, Din Rail Mountable power , factory settings, the NES & DRP Series power supplies are In compliance with IEC1000-4 IEC1000-4 (-2, -3, -4, -5, -6 , regulation, AC noise immunity and hold-up time. With the global market in mind, the NES & DRP Series power , 's advanced design techniques and global support, the NES & DRP Series power supplies will prove to be the , AC In p u t. NES: 85-265VAC 85-265VAC continuous (47-63Hz). DRP: -1 ... OCR Scan
datasheet

2 pages,
84.53 Kb

DRP-480-1 IEC1000-4 UL1950 EN60950 TEXT
datasheet frame
Abstract:  DRP INPUT Input voltage range: Continuous operation: Input current: Inrush current: DIN , time: DRP-60 to 240: 85-132/176-264VAC 85-132/176-264VAC selectable by front panel switch DRP-480-1:184-264VAC 184-264VAC only DRP-480-1AR: 85-132/176-264VAC 85-132/176-264VAC Autorange DRP-480-3: 3 Phase AC 400V, -15%, +20% (340479VAC 340479VAC) DRP480-3H DRP480-3H: 3 Phase AC 480V, -15% +20% (408-576VAC 408-576VAC) DRP-720-3 & DRP-120-3: 3 Phase 340-576VAC 340-576VAC DRP-960-3:3 Phase 340-575VAC 340-575VAC 47-63Hz SuitaPle for IT Power Systems 160-375VDC 160-375VDC: DRP-60 210-375VDC 210-375VDC: DRP-120/240 270-370VDC 270-370VDC: DRP ... OCR Scan
datasheet

7 pages,
502.18 Kb

CSA950 EN61000-4-2 VDE0160 DRP-720-3 Siemens SN 29500 DRP240-1 DRP-960-3 3 phase pfc DRP12 DRP480-1 DRP-480-1AR DRP-960C-3 DRP-120-1 lambda DRP DRP-480-1 ORP60 drp-240-1 Siemens norm SN 29500 lambda DRP960-3 drp 240-1 TEXT
datasheet frame
Abstract: Series DRP INPUT Input voltage range: Continuous operation: 160-375VDC 160-375VDC: DRP-60 210-375VDC 210-375VDC: DRP-120/240 270-370VDC 270-370VDC: DRP-480-1 450-700VDC 450-700VDC: DRP-480-3 550-820VDC 550-820VDC: DRP-480-3H 450-820VDC 450-820VDC: DRP-120-3, DRP-720-3 450-810VDC 450-810VDC: DRP-960 Input current: 60-1080 DRP-60 to 240: 85-132/176-264VAC 85-132/176-264VAC selectable by front panel switch DRP-480-1: 184-264VAC 184-264VAC only DRP-480-1AR: 85-132/176-264VAC 85-132/176-264VAC Autorange DRP-480-3: 3 Phase AC 400V, -15%, +20% (340-479VAC 340-479VAC) DRP-480-3H: 3 Phase AC 480V, -15% +20% (408-576VAC 408-576VAC) DRP ... Lambda Electronics
Original
datasheet

7 pages,
267.74 Kb

184-264VAC drp 240-1 DRP-60-1 DRP-720-3 DRP120 DRP480-1 DRP-960-3 drp-240-1 Siemens SN 29500 DRP-480-1 DRP-480-1AR Siemens norm SN 29500 DRP-120-1 TEXT
datasheet frame
Abstract: ¥3.62 657.09 638.58 NES/DRP Series Industrial JFS Series DIN Rail Power Supplies High Power Bulk cAC Input: NES — 85-265 VAC Continuous (47-63 Hz); AC-DC Power Supplies DRP (-1/-1AR Models) — 110/230 VAC, 47-63 Hz; DRP (-3H Model) — Three Phase 480-576 VAC, 47-63 Hz; cUniversal AC Input: 85-265 VAC, 47-63 Hz DRP(-3 Model) — Three Phase 340-576 VAC, 47-63 Hz 24 V (20.0-29.0) Output 24 V , DRP-60-1 ¥ 60 2.5 2.5 — — 4.88 ¥4.00 ¥1.93 171.77 166.94 1000 41.6 41.6 41.6 31.2 20.8 13.21 ¥4.88 ... Allied Electronics Catalog
Original
datasheet

1 pages,
92.34 Kb

412.88 831-4300 831-6120 drp-120-1 DRP-240-1 DRP-960-3 JWS50 lambda 1500-48 NES240-24 drp 240-3 30A15 JFS-1500-48 831-6130 41288 RS232 RS485 RS232 RS232 RS485 RS485 TEXT
datasheet frame
Abstract: Operating Temperature Range Storage Temperature Range Symbol VIN AVDD SRC SW, DRP, DRN RSTIN, DLY, CTL, FB , Oscillator frequency DRP Leakage Current Soft-Start Time Gate Shading Function (GSOUT) DLY Source Current DLY , AGND1 15 RSTIN AVDD DRP 6 5 14 FBP 10 Positive Charge pump AVDD AGND2 DRP 2 , name INP INN VCOM AGND1 AVDD DRP DRN CTL RST FBP FBN VREF VIN AGND2 RSTIN COMP FB PGND1 PGND2 SW RE , RSTIN 16 15 13k VCOM 1uF 4 3.9k 10nF AVDD 5 AGND1 AVDD DRP VREF DRN CTL RST FBP FBN ... ROHM
Original
datasheet

18 pages,
703.55 Kb

BD8184 BD8184MUV 11035EBT19 TEXT
datasheet frame
Abstract: Operating Temperature Range Storage Temperature Range Symbol VIN AVDD SRC SW, DRP, DRN RSTIN, DLY, CTL, FB , Oscillator frequency DRP Leakage Current Soft-Start Time Gate Shading Function (GSOUT) DLY Source Current DLY , AGND1 RSTIN AVDD DRP 6 5 14 FBP 10 Positive Charge pump AVDD AGND2 DRP 2 1 , AGND1 AVDD DRP DRN CTL RST FBP FBN VREF VIN AGND2 RSTIN COMP FB PGND1 PGND2 SW RE GSOUT SRC DLY , RSTIN 16 15 13k VCOM 1uF 4 3.9k 10nF AVDD 5 AGND1 AVDD DRP VREF DRN CTL RST FBP FBN ... ROHM
Original
datasheet

18 pages,
636.75 Kb

BD8184MUV 11035EBT19 TEXT
datasheet frame
Abstract: Dissipation Operating Temperature Range Storage Temperature Range Symbol VIN AVDD SRC SW, DRP, DRN RSTIN, DLY , Oscillator frequency DRP Leakage Current Soft-Start Time Gate Shading Function (GSOUT) DLY Source Current DLY , AGND1 15 RSTIN AVDD DRP 6 5 14 FBP 10 Positive Charge pump AVDD AGND2 DRP 2 , name INP INN VCOM AGND1 AVDD DRP DRN CTL RST FBP FBN VREF VIN AGND2 RSTIN COMP FB PGND1 PGND2 SW RE , RSTIN 16 15 13k VCOM 1uF 4 3.9k 10nF AVDD 5 AGND1 AVDD DRP VREF DRN CTL RST FBP FBN ... ROHM
Original
datasheet

18 pages,
704.51 Kb

BD8184MUV D8184 BD8184 TEXT
datasheet frame
Abstract: Operating Temperature Range Storage Temperature Range Symbol VIN AVDD SRC SW, DRP, DRN RSTIN, DLY, CTL, FB , FBP Input Bias Current Oscillator frequency DRP Leakage Current Soft-Start Time Gate Shading Function , AGND1 AVDD AGND1 RSTIN AVDD DRP 6 5 14 FBP 10 Positive Charge pump AVDD AGND2 DRP 2 1 6 13 INN INP DLY CTL VCOM AGND1 3 VIN 10 24 8 RST FBP 21 , 23 24 Pin name INP INN VCOM AGND1 AVDD DRP DRN CTL RST FBP FBN VREF VIN AGND2 RSTIN COMP FB PGND1 ... ROHM
Original
datasheet

18 pages,
652.67 Kb

BD8184MUV 11035EAT18 TEXT
datasheet frame
Abstract: transceivers is accessible though logic that communicates to the DRP port of the GTX transceiver. This allows , accumulate the number of words and error received. DRP and Port Access IBERT also provides flexibility for users to change GTX transceiver ports and attributes. DRP interface logic is included in the IBERT , Acronym CPRI DFE DRP FF FPGA IBERT I/O ILA ISE JTAG LUT MMCM MHz PCS PLL PMA PRBS RAM RX TX XAUI ... Xilinx
Original
datasheet

8 pages,
206.52 Kb

zynq cpri ethernet software example kintex7 ChipScope IBERT prbs pattern generator using vhdl XC7K325T user guide XC7K325T- kintex 7 XC7K325T specification XC7K325T XC7K325T-2FFG900 DS855 TEXT
datasheet frame

Archived Files

Abstract Saved from Date Saved File Size Type Download
No abstract text available
/download/42652172-393173ZC/mplabalc30v2_05.tgz
Microchip 09/11/2006 11568.47 Kb TGZ mplabalc30v2_05.tgz
No abstract text available
/download/46713865-484035ZC/gnu_tsc.bz2
Motorola 16/02/2000 22032.79 Kb BZ2 gnu_tsc.bz2