| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
1999 Checked Quality Assurance Div. Module Specificatio
Top Searches for this datasheet1999 Checked Quality Assurance Div. Module Specification Final Revision Checked Design Engineering Div. ******* Prepared Type Table Contents General Specifications Electrical Specifications.3 Optical Specifications Terminal.8 Test.10 Appearance Standards.11 Code System Production Type Number.14 Applying Precautions Precautions Relating Product Handling.15 Warranty.16 Revision History Rev. Date Page Comment DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 1/16 General Specif ications Operating Temp. min. max. min. max. *LED power condition min. max. characters lines dots character 123.2 23.0 146.0 43.0 14.0 max. max. NSD-7567 Yellow-mode Transflective 12:00 Backlight Yellow-green Apply water vaporproof material (HUMISEAL 1B31 producted CONCOAT) Holder Ground Connected Soldering. Dimensional Outline UE-32969A Storage Temp. Display Format Display Fonts Viewing Area Outline Dimensions Weight Type Viewing Angle Backlight Additional Spec. Drawings DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 2/16 2.Electrical Specif ications 2.1.Absolute Maximum Ratings VSS=0V Parameter Supply Voltage (Logic) Supply Voltage (LCD Drive) Input Voltage -0.3 VCC+0.3 VCC-VEE 13.0 Symbol VCC-VSS Conditions Min. -0.3 Max. Units 2.2.DC Characteristics Ta=25, VSS=0V Parameter Supply Voltage (Logic) Supply Voltage (LCD Drive) High Level Input Voltage Level Input Voltage High Level Output Voltage Level Output Voltage Supply Current VCC-VEE=8.4V VCC-VSS=5.0V IOL=1.2mA IOH=-0.205mA VCC=5.0V±10% -0.3 VCC=5.0V±10% VCC-VEE Shown Symbol VCC-VSS Conditions Min. Typ. Max. Units DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 3/16 2.3.AC Characteristics VCC=5.0V±10% Parameter Enable Cycle Time Enable Pulse Width Enable Rise/Fall Time Address Setup Time Address Hold Time Write Data Setup Time Write Data Hold Time Read Data Delay Time Read Data Hold Time Symbol Conditions Fig.1, Fig.1, Fig.1, Fig.1, Fig.1, Fig.1 Fig.1 Fig.2 Fig.2 Min. Max. Units tCYC PWEH tEr, tDSW tDHW tDDR tDHR PWEH tDSW DB0DB7 tDHW Valid Data tCYC Fig.1 Write Operation Timing PWEH tDDR DB0DB7 tDHR Valid Data tCYC Fig.2 Read Operation Timing DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 4/16 2.4.Lighting Specifications 2.4.1.Absolute Maximum Ratings Ta=25 Parameter Foward Current Reverse Voltage Symbol Conditions Note Min. Typ. Max. Units Power Dissipation Note Refer foward current derating curve. (mA) 2.4.2.Operating Characteristics Ta=25 Parameter Foward Voltage Luminance Symbol Conditions IF=300mA IF=300mA*1 Min. Typ. Max. Units Backlight Surface Take measurement unit only. DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 5/16 3.Optical Specif ications 3.1.LCD Driving Voltage Parameter Recommended Driving Voltage Note VCC-VEE Symbol Conditions Ta=25 Ta=50 Min. Typ. Max. Units Ta=70 Note Voltage (Applied actual waveform Module) best contrast. range minimum maximum shows tolerance operating voltage. specified contrast ratio response time guaranteed over entire range. 3.2.Optical Characteristics Ta=25, 1/16 Duty, Bias, VD=8.4V (Note Parameter Contrast Ratio Viewing Angle Response Rise Note Note Symbol Conditions Min. Typ. Max. Units Shown Time Decay Note TOFF Note Contrast ratio definded follows. LOFF Luminance segments LOFF Luminance segments Note time that luminance level reaches saturation level from when signal applied. Note time that luminance level reaches saturation level from 100% when signal applied. Note Definition Driving Voltage Assuming that typical driving waveforms shown below applied Panel Duty Bias Duty Number, Bias Number Driving voltage definded follows. (Vth1+Vth2) Vth1 voltage VO-P that should provide saturation level luminance segment which signal applied Vth2 voltage VO-P that should provide saturation level luminance segment which signal applied VO-P VO-P SIGNAL SIGNAL DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 6/16 3.3.Definition Viewing Angle Optimum Viewing Area Point shows point where contrast ratio measured. Driving condition 1/16 Duty, Bias, VD=8.4V, fF=84.4Hz Area shows typ. 3.4.System Block Diagram Temperature Chamber Rotation Table Photometer #1980A Optical Fiber Computer Control Unit Waveform Generator Halogen bulb DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 7/16 4.I/O Terminal 4.1.Pin Assignment Symbol LED, LED, Level Power Supply (0V, GND) Power Supply Logic Power Supply Drive Register Select Signal Read/Write Select Signal Read Write Enable Signal pull-up Resister) Data Line Non-connection 4-bit operation Data Line Non-connection 4-bit operation Data Line Non-connection 4-bit operation Data Line Non-connection 4-bit operation Data Line Data Line Data Line Data Line Cathode Terminal Anode Terminal Function 4.2.Example Power Supply recommended apply potentiometer contrast adjust tolerance driving voltage temperature dependence. MODULE (+Voltage) (-Voltage) VR=1020K (0V) DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 8/16 4.3.Block Diagram LCDP characters lines Control HD44780 equivalent Column Driver NJU6417 equivalent Bias Circuit LED, Backlight LED, DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 9/16 5.Test change display operation under following test condition. Parameter High Temperature Operating Temperature Operating High Temperature Storage Temperature Storage Damp Proof Test Vibration Test Conditions 70±2, 96hrs (operation state) -20±2, 96hrs (operation state) 70±2, 96hrs -20±2, 96hrs 40±2, 9095%RH, 96hrs Total fixed amplitude 1.5mm Vibration Frequency 1055Hz cycle seconds directions each minutes Shock Test measured after dropping from 60cm high concrete surface packing state. Notes 60cm Concrete Surface Dropping method corner dropping corner once Edge dropping B,C,D edge once Face dropping E,F,G face once Note Unless otherwise specified, tests will conducted under following condition. Temperature 20±5 Humidity 65±5% Note Unless otherwise specified, tests will conducted under functioning state. Note condensation observed. Note function test shall conducted after hours storage normal temperature humidity after removed from test chamber. Note Vibration test will conducted product itself without putting container. DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 10/16 6.Appearance Standards 6.1.Inspection conditions shall inspected under white fluorescent light. distance between eyes sample shall more than 30cm. directions inspecting sample should within against perpendicular line. 6.2.Definition applicable Zones Zone Zone Zone Bezel Flame Zone Active display area Zone Area from outside Zone" validity viewing area Zone Rest parts Zone Zone Validity viewing area DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 11/16 6.3.Standards Parameter Black White Spots, Foreign Substances Dimension (mm) Long Short Line Shape Zone X(mm) 2.0L 1.0L 1.0L Y(mm) 0.02W 0.03W 0.04W 0.05W 0.05W Acceptable Number same Disregard Round Shape Zone Disregard Acceptable Number Criteria Length Width Total defects shall exceed Bubbles (between glass polarizer) Dimension (mm) 0.15 0.15 Disregard Total defects shall exceed Zone Acceptable Number DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 12/16 Parameter Shape Shape (with Dent) 0.15 Criteria sketch left hand. Shape (with Projection) Should connected next dot. Hole (X+Y) 20.2mm (Less than 0.1mm counted.) Total defects shall exceed Polarizer Scratches Polarizer Dirts conspicuous defects. stains removed easily from LCDP surface, module defective. Color Variation conspicuous defects. DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 13/16 7.Code System Production production module specified follows. Factory Number (Numeral) Factory Code (Alphabet) Production Week (15) Production Month (19, Production Year (Lower digits) 8.Type Number type number module specified back module follows. Stamp Etching Printing 9.Applying Precautions Please contact when questions and/or problems specified this specifications arise. DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 14/16 10.Precautions Relating Product Handling Following precautions will guide handling product correctly. Liquid crystal display devices liquid crystal display device panel used liquid crystal display module made plate glass. Avoid strong mechanical shock. Should glass break handle with care. polarizer adhering surface made soft material. Guard against scratching Care liquid crystal display module against static electricity discharge. When working with module, sure ground your body electrical equipment using. strongly recommend anti static mats made rubber protect work tables against hazards electrical shock. Avoid work clothing made synthetic fibers. recommend cotton clothing other conductivity-treated fibers. Slowly carefully remove protective film from module, since this operation generate static electricity. When module alone must stored long periods time: Protect modules from high temperature humidity. Keep modules direct sunlight direct exposure ultraviolet rays. Protect modules from excessive external forces. module with power supply that equipped with overcurrent protector circuit, since module provided with this protective feature. ingest fluid itself should leak damaged module. Should hands clothing come contact with fluid, wash immediately with soap. Conduc1tivity guaranteed models that metal holders where solder connections between metal holder used. Please contact discuss appropriate ways assure conductivity. models which CFL: High voltage 1000V greater applied cable connector area. Care should taken touch connection areas avoid burns. Protect cables from rubbing against unit thus causing wire jacket become worn. CFLs extended periods time temperatures will significantly shorten their service life. DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 15/16 models which touch panels: stack modules since they damaged components neighboring modules. place heavy objects product. This could cause glass breakage. models which COG,TAB,or COF: mechanical strength product since chip faces unprotected from rear. sure protect rear chip from external forces. Given fact that rear chip left exposed, order protect unit from electrical damage, avoid installation configurations which rear chip runs risk making electrical contact. Models which flexible cable, heat seal, TAB: order maintain reliability, touch hold connector area. Avoid bending, pulling, other excessive force, which result broken connections. 11.Warranty This product been manufactured your company's specifications part your company's general electronic products. guaranteed perform according delivery specifications. other apart from general electronic equipment, cannot take responsibility product used medical devices, nuclear power control equipment, aerospace equipment, fire security systems, other applications which there direct risk human life where extremely high levels reliability required. product used above applications, will need enter into separate product liability agreement. cannot accept responsibility defect, which arise from additional manufacturing product (including disassembly reassembly), after product delivery. cannot accept responsibility defect, which arise after application strong external force product. cannot accept responsibility defect, which arise application static electricity after product passed your company's acceptance inspection procedures. When product models, service life brightness will vary according performance inverter used, leaks, etc. cannot accept responsibility product performance, reliability, defect, which arise. cannot accept responsibility industrial property, which arise through your product, with exception those issues relating directly structure method manufacturing product. Optrex will held responsible quality guarantee issue defect products judged Optrex-origin longer than (two) years from Optrex production 1(one) year from Optrex, Optrex America, Optrex Europe, Display delivery which ever comes later. DMC20203NYJU-SLY-D-2 (AJ) No.99-0276 OPTREX OPTREX CORPORATION Page 16/16 Other recent searchesXRO2LMR40DRV - XRO2LMR40DRV XRO2LMR40DRV Datasheet uPD23C32082L - uPD23C32082L uPD23C32082L Datasheet SN74ALVC7814 - SN74ALVC7814 SN74ALVC7814 Datasheet SN74ACT7804 - SN74ACT7804 SN74ACT7804 Datasheet SN74ACT7806 - SN74ACT7806 SN74ACT7806 Datasheet SN74ACT7814 - SN74ACT7814 SN74ACT7814 Datasheet QB-144GJ-EA-02S - QB-144GJ-EA-02S QB-144GJ-EA-02S Datasheet PIC16C92x - PIC16C92x PIC16C92x Datasheet nAD1001-18 - nAD1001-18 nAD1001-18 Datasheet CM312V1 - CM312V1 CM312V1 Datasheet 2SA1761 - 2SA1761 2SA1761 Datasheet
Privacy Policy | Disclaimer |