| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Small case, profile: 50.8 50.8 12.7 (2.00 2.00 0.50 in.) Overcurrent p
Top Searches for this datasheetFE008-Series Power Modules: dc-dc Converters; Inputs, Outputs, Small case, profile: 50.8 50.8 12.7 (2.00 2.00 0.50 in.) Overcurrent protection: unlimited duration Output overvoltage protection: Line load regulation: <0.2% maximum Short-circuit protection Remote on/off (FE008AJ1 only) Undervoltage lockout Input-to-output isolation external filtering required Operating ambient temperature range: Synchronization (FE008AJ3 only) FE008-Series Power Modules advanced surfacemount technology deliver high-quality, compact, dc-dc conversion economical price. Application Communication equipment networks with inputs Computer equipment Digital circuits Distributed power architecture 1950 Recognized, C22.2 950-95 Certified Within Class limit registered trademark Underwriters Laboratories, Inc. registered trademark Canadian Standards Association. Description FE008AJ, AJ1, Power Modules dc-dc converters that operate from nominal inputs provide precisely regulated outputs. outputs fully isolated from inputs, allowing versatile polarity configurations grounding connections. Each unit provides output power, with from output. Each device encapsulated nonconductive case, 50.8 long, 50.8 wide, 12.7 high (2.00 2.00 0.50 in.), that mounts board. FE008AJ1 identical FE008AJ except that remote on/off control. FE008AJ3 identical FE008AJ except that synchronized external clock logic signal. FE008-Series Power Modules: dc-dc Converters; Inputs, Outputs, Absolute Maximum RatingStresses excess absolute maximum ratings cause permanent damage device. These absolute stress ratings only. Functional operation device implied these other conditions excess those given operations sections data sheet. Exposure absolute maximum ratings extended periods adversely affect device reliability. Parameter Input Voltage: Continuous Transient second) Isolation Voltage Synchronization Voltage Operating Ambient Temperature ft./min. natural convection) Storage Temperature Symbol trans Vsync Tstg Unit Electrical SpecificationUnless otherwise indicated, specifications apply over operating input voltage, resistive load, temperature conditions. Table Input Specifications Parameter Operating Input Voltage Maximum Input Current max) Inrush Transient Input Reflected-ripple Current MHz, source impedance, Figure Design Considerations section.) Input Inductance (See Design Considerations section.) Input Ripple Rejection (120 Fusing Considerations CAUTION: This power module internally fused. input line fuse must always used. This encapsulated power module used wide variety applications, ranging from simple stand-alone operation integrated part sophisticated power architecture. preserve maximum flexibility, internal fusing included; however, achieve maximum safety system protection, always input line fuse. safety agencies require normal-blow fuse with maximum rating series with input (see Safety Considerations section). Based information provided this data sheet inrush energy maximum input current, same type fuse with lower rating used. Refer fuse manufacturer's data further information. Symbol 39.5 Unit mAp-p Tyco Electronics Corp. FE008-Series Power Modules: dc-dc Converters; Inputs, Outputs, Electrical Specifications (continued) Table Output Specifications Parameter Initial Output Voltage Point max; Output Voltage (over operating input voltage, resistive load, temperature conditions until life) Output Regulation (VO1, VO2): Line 39.5 Load max) Temperature Output Ripple Noise Voltage (with ceramic, bypass capacitor each output): Peak-to-peak MHz) Output Current: Output Output Total Outputs Output Current-limit Inception: -4.5 Output Short-circuit Current -250 Efficiency max; Figure Dynamic Response (IO/t A/10 °C): Load Change from max: Peak Deviation: Settling Time peak deviation): Load Change from max: Peak Deviation: Settling Time peak deviation): Symbol VO1, VO2, 4.85 -4.85 4.80 -4.80 5.00 -5.00 5.20 -5.20 5.25 -5.25 Unit 0.001 0.05 0.01 0.40 1.60 mVrms mVp-p Tyco Electronics Corp.3 FE008-Series Power Modules: dc-dc Converters; Inputs, Outputs, Electrical Specifications (continued) Table Isolation Specifications Parameter Isolation Capacitance Isolation Resistance 1200 Unit General SpecificationParameter Calculated MTBF max; Weight 7,240,000 Unit hours (oz.) (1.9) Feature SpecificationUnless otherwise indicated, specifications apply over operating input voltage, resistive load, temperature conditions. Parameter Remote On/Off (FE008AJ1 only) open collector equivalent compatible; signal referenced VI(-) terminal; Feature Descriptions section.): Logic Low-Module Logic High-Module Module Specifications: On/Off Current-Logic On/Off Voltage: Logic Logic High (Ion/off Open Collector Switch Specifications: Leakage Current During Logic High (Von/off Output Voltage During Logic (Ion/off Turn-on Time max; within steady state) Output Undervoltage Lockout: Unit Unit Output Overvoltage Protection (clamp) Synchronization Signal Specifications (FE008AJ3 only) (referenced VI(+) terminal): Frequency Logic-High State Voltage (sourcing Logic-Low State Voltage (sinking Rise/Fall Time Duty Cycle Symbol Unit Ion/off Von/off Von/off Ion/off Von/off VO1, clamp VO1, clamp -7.5 Tyco Electronics Corp. FE008-Series Power Modules: dc-dc Converters; Inputs, Outputs, Test ConfigurationTO OSCILLOSCOPE OSCILLOSCOPE LTEST IMPEDANCE Safety ConsiderationFor safety-agency approval system which power module used, power module must installed compliance with spacing separation requirements end-use safety agency standard, i.e., 1950, C22.2 950-95. input source non-SELV (ELV hazardous voltage greater than less than equal Vdc), module's output considered meeting requirements safety extra-low voltage (SELV), following must true: BATTERY 8-489(C).a Note: Input reflected-ripple current measured with simulated source impedance Capacitor offsets possible battery impedance. Current measured input module. input source provided with reinforced insulation from other hazardous voltages, including mains. grounded, both input output pins kept floating. input pins module operator accessible. Another SELV reliability test conducted whole system, required safety agencies, combination supply source subject module verify that under single fault, hazardous voltages appear module's output. Figure Input Reflected-Ripple Test Setup VI(+) SUPPLY LOAD VI(-) CONTACT RESISTANCE CONTACT DISTRIBUTION LOSSES 8-506(C) LOAD Note: ground either input pins module without grounding output pins. This allow non-SELV voltage appear between output pins ground. power module extra-low voltage (ELV) outputs when inputs ELV. input these units provided with maximum normal-blow fuse ungrounded lead. Note: Take measurements module terminals. When socketing, place Kelvin connections module terminals avoid measurement errors socket contact resistance. Design ConsiderationInput Source Impedance power module should connected low-acimpedance input source. Source impedances greater than affect stability power module. When source impedance exceeds mount electrolytic capacitor (ESR kHz) close module input pins. This also recommended minimize reflected-ripple current well conducted radiated electromagnetic interference (EMI). Figure Output Voltage Efficiency Measurement Test Setup Tyco Electronics Corp. FE008-Series Power Modules: dc-dc Converters; Inputs, Outputs, Feature DescriptionOutput Overvoltage Protection output overvoltage clamp consists control circuitry, independent primary regulation loop, that monitors voltage output terminals. control loop clamp point that higher than point primary loop (see Feature Specifications table). This provides redundant voltage-control that reduces risk output overvoltage. During logic high, maximum Von/off generated power module maximum allowable leakage current switch Von/off Note: trace between ON/OFF terminal VI(-) terminal used override remote on/off. Either user-supplied switch override jumper should wired into circuit individual traces common with power current path. Connect switch jumper power module terminals (see Figure Configuring switch connection this prevents noise from falsely triggering remote on/off. COMMON CONNECTION POINT Ion/off Von/off ON/OFF Overcurrent Protection provide protection fault (output overload) condition, unit equipped with internal current-limiting endure current limiting unlimited duration. point current-limit inception, unit shifts from voltage control current control. output voltage pulled very during severe fault, current-limit circuit exhibit tailout characteristics (output-current increase). unit operates normally once output current brought back into specified range. VI(+) VI(-) 8-598(C) Remote On/Off (FE008AJ1 only) turn power module off, user must supply switch control voltage between ON/OFF terminal VI(-) terminal (Von/off). switch open collector equivalent (see Figure logic Von/off during which module maximum Ion/off during logic switch should maintain logic-low voltage while sinking Figure Remote On/Off Wiring Configuration; View Synchronization (FE008AJ3 only) switching frequency FE008AJ3 synchronized external clock signal specified Feature Specifications table. signal referenced positive side input bus. minimize noise, clock signal ground should separately from power ground. With signal applied, module switches frequency lower than specified synchronization frequency, guaranteed meet specifications. Tyco Electronics Corp. FE008-Series Power Modules: dc-dc Converters; Inputs, Outputs, Outline DiagramDimensions millimeters (inches). Tolerances: (0.02 in.), x.xx 0.25 (0.010 in.) FE008AJ FE008AJ1 Power ModuleTop View FE008AJ1 ONLY 50.8 (2.00) FE008AJ3 Power Module View 50.8 (2.00) Lucent 50.8 (2.00) ON/OFF Lucent 50.8 (2.00) SYNC FE008AJ1 DC-DC Power Module IN:DC 48V, 0.20A OUT:DC 1.2A OUT2:DC -5V, 0.4A FE008AJ3 DC-DC Power Module IN:DC 48V, 0.23A OUT:DC 1.2A OUT2:DC -5V, 0.4A MADE Rheinland Rheinland MADE Side View 12.7 (0.50) Side View 12.7 (0.50) (0.11) 0.79 (0.031) PIN, 0.51 (0.020) (0.11) 0.79 (0.031) PIN, 0.51 (0.020) Bottom View Bottom View 35.3 (1.39) 20.32 (0.800) 35.3 (1.39) 20.32 (0.800) FE008AJ1 ONLY 5.08 (0.200) 5.08 (0.200) 2.54 (0.100) 7.62 (0.300) 22.9 (0.90) 12.70 (0.500) 22.9 (0.90) 5.08 (0.200) 2.54 (0.100) 7.62 (0.300) 12.70 (0.500) 10.16 (0.400) 8-613(C) 8-603(C) Tyco Electronics Corp.7 FE008-Series Power Modules: dc-dc Converters; Inputs, Outputs, Recommended Hole PatternComponent-side footprint. Dimensions millimeters (inches). FE008AJ FE008AJ1 Power ModuleFE008AJ1 ONLY MODULE OUTLINE FE008AJ3 Power Module MODULE OUTLINE 20.32 (0.800) 35.3 (1.39) 35.3 (1.39) 20.32 (0.800) 5.08 (0.200) 5.08 (0.200) 2.54 (0.100) 7.62 (0.300) 22.9 (0.90) 12.70 (0.500) 5.08 (0.200) 2.54 (0.100) 7.62 (0.300) 22.9 (0.90) 8-603(C) 12.70 (0.500) 10.16 (0.400) 8-613(C) Ordering Information Remote On/Off Logic Input Voltage Output Voltage Output Power Synchronization Device Code FE008AJ FE008AJ1 FE008AJ3 Comcode Discontinued Discontinued 106358948 Tyco Electronics Power Systems, Inc. 3000 Skyline Drive, Mesquite, 75149, +1-800-526-7819 FAX: +1-888-315-5182 (Outside U.S.A.: +1-972-284-2626, FAX: +1-972-284-2900) Tyco Electronics Corporation reserves right make changes product(s) information contained herein without notice. liability assumed result their application. rights under patent accompany sale such product(s) information. 2001 Tyco Electronics Corporation, Harrisburg, International Rights Reserved. Printed U.S.A. 2000 DS98-308EPS (Replaces DS91-057EPS) Printed Recycled Paper Other recent searchesUF2A - UF2A UF2A Datasheet UF2M - UF2M UF2M Datasheet HVM189S - HVM189S HVM189S Datasheet AL106-84 - AL106-84 AL106-84 Datasheet ADC1219112 - ADC1219112 ADC1219112 Datasheet 2SA0719 - 2SA0719 2SA0719 Datasheet 2SA0720 - 2SA0720 2SA0720 Datasheet 2SA719 - 2SA719 2SA719 Datasheet 2SA720 - 2SA720 2SA720 Datasheet 1827334 - 1827334 1827334 Datasheet
Privacy Policy | Disclaimer |