| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
LED-Based Linear Displacement Sensor with Complementary Discrete Outpu
Top Searches for this datasheetL-GAGE® Q50A Series with Complementary Discrete Outputs LED-Based Linear Displacement Sensor with Complementary Discrete Outputs TEACH-Mode Programming L-GAGE Q50A Complementary Discrete Output Sensor Features Cost-effective LED-based complementary-discrete sensor Fast, easy-to-use TEACH-Mode programming; potentiometer adjustments Models available with either millisecond response speed Models available with either visible infrared beam Teach sensing window switch points) teach single switch point (adjustable field mode) sensing ranges, depending model: (visible beam models), (infrared beam models) Good color sensitivity Remote TEACH input security convenience bicolor Status LEDs NOTE: Q50B models also available, with range Choose meter meter unterminated cable, swivel 5-pin Euro-style connector Rugged construction withstands demanding sensing environments; rated IP67, NEMA L-GAGE Q50A Complementary Discrete Output Sensor Models Model Number Q50AVN Q50AVNQ Q50AVNY Q50AVNYQ Q50AVP Q50AVPQ Q50AVPY Q50AVPYQ Q50AN Q50ANQ Q50ANY Q50ANYQ Q50AP Q50APQ Q50APY Q50APYQ (2.0" 7.9") (2.0" 5.9") Sensing Range Cable* 5-wire, (6.5') cable Supply Voltage Beam Output Response Time 5-pin Euro-style 5-wire, (6.5') cable 5-pin Euro-style 5-wire, (6.5') cable 5-pin Euro-style 5-wire, (6.5') cable 5-pin Euro-style 5-wire, (6.5') cable 5-pin Euro-style 5-wire, (6.5') cable 5-pin Euro-style 5-wire, (6.5') cable 5-pin Euro-style 5-wire, (6.5') cable 5-pin Euro-style Infrared Visible Complementary Complementary Complementary Complementary meter cables available adding suffix "W/30" model number cabled sensor (e.g., Q50AVN W/30). model with connector requires mating cable; page Printed 06/01 67417 L-GAGE Q50A Complementary Discrete Output Sensor Sensor Overview Q50A Complementary Discrete easy-to-use triangulation sensor which provides sophisticated, costeffective solution demanding applications. Q50A Series sensors feature compact, all-in-one design require separate controller. Each sensor discrete outputs (both both PNP). complementary output configured conditions: sensing window consisting switch points single switch point, with adjustable-field sensor Optical Triangulation function Q50A Sensor based optical triangulation (see Figure emitter circuitry optics create light source which directed toward target. light source bounces target, scattering some light through sensor's receiver lens position-sensitive-device (PSD) receiver element. target's distance from receiver determines light's angle receiver element; this angle determines where returned light will touch receiver element. position light receiver element processed through digital electronics analyzed microprocessor. microprocessor will compare target position taught window limits then change discrete outputs required. Receiver Element Signal Conditioning Circuitry Lenses Near Limit Limit Target Movement Microprocessor Output Circuitry Emitter Circuitry Emitter Programmed Sensing Window Figure Using optical triangulation determine sensing distance Teach/Output Indicator (yellow red) Range Indicator (red green) Programming Push Button fitting rotates hookup direction Figure L-GAGE Q50A sensor features Banner Engineering Corp. Minneapolis, U.S.A. page www.bannerengineering.com Tel: 763.544.3164 L-GAGE Q50A Complementary Discrete Output Sensor Using Q50A Complementary Discrete Output Sensor Q50A Response Times Note: Q50AV range Q50AVY range Response Speed Response speed either Fast Slow ms), depending model. Window Limits Window limits taught sensor either remotely (using gray wire) using sensor's Teach push button. Hysteresis (mm) Q50A Fast Response Q50A Slow Response sensor operates modes: TEACH programming) mode mode. NOTE: indicators momentarily when sensor changes state between TEACH modes. Indicator Status Conditions Indicator Status Range Green Target within sensing range (green/red) Target outside sensing range Flashing Green Discrete output overloaded Sensor Power Teach/Output (yellow/red) Yellow (window limits) Target within taught limits Yellow (fixed field) Target closer than cutoff limit Target outside taught window limits Sensor TEACH mode Target Position (mm) Note: Surface color does affect hysteresis black NOTE: white reflectance surfaces) Surface color does affect hysteresis black white reflectance surfaces). Figure L-GAGE Q50A (Complementary Discrete) Hysteresis Position Color Sensitivity (mm) Reflectance Kodak White Card Reflectance Black Card TEACH-Mode Programming Reflectance Kodak White Card Reflectance Grey Card Target Position (mm) NOTES: Color sensitivity independent response time Q50A.(infrared models) span 50-200 Q50AV. (visible models) span 50-150 Push-Button Procedure Teaching Window Limits (Complementary Outputs) Press hold Teach push button until Teach turns (depress button about seconds). This indicates sensor waiting first window limit. Position target first limit. Range should green, indicating valid target. Briefly "click" Teach push button. This will teach sensor first limit. Teach will flash acknowledge receiving first window limit; waiting second limit. Position target second limit "click" Teach push button again teach sensor second limit. Teach will return either yellow sensor returns mode. NOTE: yellow follows black wire output. Sensing Window with Complementary Outputs Window RANGE TEACH OUTPUT Figure L-GAGE Q50A Complementary Discrete Color Sensitivity Position (This represents expected change output when target color changed from reflectance Kodak White Card reflectance surface.) White Wire Conducting Black Wire Conducting White Wire Conducting Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Figure Programming single pair sensing window limits, complementary outputs page Sensing Range L-GAGE Q50A Complementary Discrete Output Sensor Push-Button Procedure Teaching Single Sensing Point (Complementary Outputs Adjustable-Field Style) black wire conducts when target inside programmed point. white wire conducts when target outside (away from) point (see Figure Press hold Teach push button until Teach turns (depress button approximately seconds). Position target sensing point. Range should green, indicating valid target. Briefly "click" Teach push button. This will teach sensor first limit. Teach will flash acknowledge receiving first window limit; waiting second limit. Maintain same target position "click" Teach push button again teach same window position. Teach will return either yellow sensor returns mode. Note: yellow will follow black wire output. Remote Programming function provided program sensor remotely disable/enable push button; this accomplished gray wire. Disabling push button prevents anyone production floor from adjusting programming settings. Connect gray wire Sensor with remote programming switch connected between them. NOTE: impedance remote teach input program, pulse wire illustrated Figure NOTE: duration each pulse (corresponding push button "click") 0.04 seconds. Mode NOTE: indicators momentarily when sensor changes state between TEACH modes. Range When sensor detects target within sensing range (either visible-beam models, infrared beam models) will solid green. absence target, Range solid red. Refer Indicator Status table page Teach/Output mode, Output yellow when target sensed within programmed window limits; otherwise Output red. Refer Indicator Status table page Dual Discrete Outputs complementary dual discrete outputs either both both PNP. outputs configured Teach procedure either single window fixed-field (single point) application. outputs short circuit-protected switch (resistive load). page Push Button Lockout Push Button Lockout Remote Teach Window Limits Teach First Window Limit Teach Second Window Limit 0.04 Figure Timing remote TEACH programming Single Sensing Point with Complementary Outputs TEACH OUTPUT RANGE Black Wire Conducting Sensing Range White Wire Conducting Figure Programming separate sensing point limits, complementary outputs Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 L-GAGE Q50A Complementary Discrete Output Sensor Installation Notes Some targets (those with stepped plane facing sensor, boundary line, rounded targets) pose specific problems sensing distances. such applications, Figure suggested mounting orientations. Recommended Recommended Figure Sensor orientations typical targets Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 page L-GAGE Q50A Complementary Discrete Output Sensor L-GAGE Q50A Complementary Discrete Output Sensor Specifications Sensing Range Supply Voltage Supply Protection Circuitry Delay Power-up Sensing Beam Output Rating Q50AV: (2.0" 5.9") Q50A: (2.0" 7.9") (10% maximum ripple); max. (exclusive load) Protected against reverse polarity transient overvoltages seconds Wave length Beam Size Q50AV: (typical) Q50AV: dia. (max.) Q50A: (typical) Q50A: dia. (max.) Complementary Discrete Output maximum, output OFF-state leakage current: Less than micro-amps ON-state saturation voltage: Less than less than 1.5V SPDT (complementary) solid-state switch. Choose (current sinking) (current sourcing) outputs. Protected against false pulse power-up continuous overload short circuit outputs 2-second delay power-up Fast: Slow: Figure Slow Response (Q50A): 0.5% sensing distance Fast Response (Q50A.Y): 1.0% sensing distance Figure Teach: Disable: Connect gray wire Connect gray wire open connection) Output Configuration Output Protection Output Response Time Output Hysteresis Sensing Repeatability Color Sensitivity (typical) Remote Teach Input Impedance Remote Teach Input Adjustments Indicators Sensing Window Limits: TEACH-mode programming near window limits using Teach push button remotely gray Teach wire. Range Indicator (green/red) Green Target within sensing range Target outside sensing range Flashing Green Outputs overloaded Sensor Power Yellow (window limits) Target within taught limits Yellow (fixed field) Target closer than cutoff limit Target outside taught window limits Sensor TEACH mode Distance Teach/Output Indicator (yellow/red) Minimum Taught Window (millimeters) Model Number Q50AV. Q50AV.Y Q50A. Q50A.Y Ambient Light Immunity <10,000 Banner Engineering Corp. Minneapolis, U.S.A. page www.bannerengineering.com Tel: 763.544.3164 L-GAGE Q50A Complementary Discrete Output Sensor L-GAGE Q50A Complementary Discrete Output Sensor Specifications (continued) Construction Environmental Rating Connections Operating Conditions Vibration Mechanical Shock Application Notes Hardware Housing: Molded ABS/Polycarbonate Window Lens: Acrylic IP67, NEMA 5-conductor PVC-covered attached cable 5-pin Euro-style quick disconnect Temperature: -10° +55°C (+14° +131°F) Max. Rel. Humidity: +50°C (non-condensing) models meet Mil. Std. 202F requirements. Method 201A (Vibration: 60Hz max. double amplitude 0.06", maximum acceleration 10G). Also meets 947-5-2 requirements: 30G, duration, half sine wave. Allow 15-minute warm-up maximum performance. hardware included. L-GAGE Q50A Dimensions RANGE 19.7 (0.77") TEACH OUTPUT 67.3 (2.65") (0.59") 49.8 (1.96") (0.13") Receiver NEAR Limits. Q50AVNQ Q50AVN RANGE: Bare Output Load Output 60.0 (2.36") 77.0 (3.03") Press hold Teach button until Teach light turns (RED) Adjust target limit position. Press Teach button. (Teach flashes) Adjust target limit position. Press Teach button (Teach turns off) (0.98") RANGE: 52.0 (2.05") Output Load Output 12-30V 12-30V Emitter Load Teach +5-30V Load +5-30V L-GAGE L-GAGE (0.59") (0.16") (0.16") 41.8 (1.65") L-GAGE Q50A Hookups Cabled Models Output Load Output Hookups Quick-Disconnect Models 12-30V Output Load Output Cabled Models Output Load Output Hookups Quick-Disconnect Models Output Load Output 12-30V 12-30V 12-30V Load +5-30V Bare Load Teach +5-30V Load +5-30V Bare Load Teach +5-30V Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 page L-GAGE Q50A Complementary Discrete Output Sensor Accessories Euro-Style Quick-Disconnect Cables Style Model MQDEC2-506 MQDEC2-515 MQDEC2-530 Length (6.5') (15') (30') Connector (0.6") max. (1.7") Pin-out 5-Pin Euro Straight White Wire Brown Wire Blue Wire max. (1.5") Black Wire Gray Wire 5-Pin Euro MQDEC2-506RA RightMQDEC2-515RA angle MQDEC2-530RA (6.5') (15') (30') (0.6") max. (1.5") Mounting Brackets SMBQ50 Right-angle bracket 14-ga., Stainless Steel 53.0 (2.09") (0.16") (0.16") 42.0 (1.65") (0.32") 15.0 (0.60") 67.0 (2.63") 66.7 (2.63") WARNING Used Personnel Protection (0.16") Never these products sensing devices personnel protection. Doing could lead serious injury death. These sensors include selfchecking redundant circuitry necessary allow their personnel safety applications. sensor failure malfunction cause either energized de-energized sensor output condition. Consult your current Banner Safety Products catalog safety products which meet OSHA, ANSI standards personnel protection. WARRANTY: Banner Engineering Corp. warrants products free from defects year. Banner Engineering Corp. will repair replace, free charge, product manufacture found defective time returned factory during warranty period. This warranty does cover damage liability improper application Banner products. This warranty lieu other warranty either expressed implied. (0.28") 38.8° 32.5 (1.28") (0.07") 10.0 (0.39") 20.0 (0.79") (0.17") (0.07") R24.1 (0.95") R2.25 (0.09") Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, 55441 Phone: 763.544.3164 www.bannerengineering.com Email: sensors@baneng.com Other recent searchesTPS795xx - TPS795xx TPS795xx Datasheet IVGC4251 - IVGC4251 IVGC4251 Datasheet EPC1011 - EPC1011 EPC1011 Datasheet AD8541 - AD8541 AD8541 Datasheet AD8542 - AD8542 AD8542 Datasheet AD8544 - AD8544 AD8544 Datasheet
Privacy Policy | Disclaimer |