| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Advanced sensor with plastic fiber optics Expert Features Ea
Top Searches for this datasheetExpert- Dual Discrete Outputs Advanced sensor with plastic fiber optics Expert Features Easy-to-set automatic Expert-style TEACH options* including static, dynamic, single-point programming plus manual adjustment fine-tuning 16-bit microcontroller 12-bit Analog-to-Digital converter highperformance, low-contrast sensing Easy-to-read 4-digit display TEACH signal strength readout, plus indicators continuous readout operating status (user configurable) discrete outputs, Four-mode power speed selection with automatic cross-talk avoidance circuitry Selectable OFF-delay options Gate input wire used selectively inhibit sensor outputs from switching Models available with visible (680 visible green (525 sensing beam Models available with (6.5' 30') cable integral quick-disconnect Sleek, ultra-slim housing, mounts standard rail U.S. Patent #5,808,296 Expert Models Models Beam D10DNFP D10DNFPQ D10DPFP D10DPFPQ Green Beam D10DNFPG D10DNFPGQ D10DPFPG D10DPFPGQ Cables* (6.5') Cable 6-pin Pico-style (6.5') Cable 6-pin Pico-style Discrete Outputs (30') cables available adding suffix "W/30" model number cabled sensor (e.g., D10DNFP W/30). model with connector requires mating cable (see page 12). Printed 08/01 64154 rev. Expert Fiber-Optic Sensor Expert Description Expert Sensor high-performance plastic fiber-optic sensor whose many configuration (TEACH-mode) options make suitable demanding applications. Even with features, extremely easy use. Advanced 16-bit microcontroller technology makes this possible. Expert provides high-performance sensing low-contrast applications, with Expert TEACH setup with static, dynamic single-point programming plus manual fine adjustment, remote programming lockout. slender, stylized housing large digital display visible beneath clear cover easy programming status monitoring during operation. sensor mounts directly standard rail using supplied mounting bracket. sensor features outputs with independent set-points: either PNP, depending model. Built-in crosstalk avoidance protocol provides trouble-free operation multiple sensors area. Dual-Discrete Outputs Output Indicator Output Indicator 4-Digit Display Output Select Indicators Lock Icon Clock Icon Light/Dark Operate Icon Static Programming Push Button Dynamic Programming Push Button Figure indicators Specifications Required Fiber-Optic Cable Sensing Beam Supply Voltage Current Supply Protection Circuitry Output Configuration Output Rating Banner P-Series plastic fibers Visible red, Visible green, depending model (10% maximum ripple) less than exclusive load Protected against reverse polarity transient voltage. Specify Model: maximum load OFF-state leakage current: ON-state saturation voltage: 1.5V load 2.5V load Protected against false pulse power-up continuous short-circuit Programmable, microseconds, microseconds, millisecond, milliseconds NOTE: millisecond delay power-up; outputs conduct during this time. Push-button remote programming response time, OFF-delay, light-dark operate, display Four-digit digital display plus indicators active channel, push-button lockout, OFF-delay light/dark operate selection. backlight (red Program mode green mode) indicates Power amber output indicators Black ABS/polycarbonate alloy (UL94 rated) housing, clear polycarbonate cover. NEMA IP50 PVC-jacketed (6.5' 30') 6-wire integral cable integral 6-pin Pico-style quick-disconnect Temperature: -20° +55°C (-4° +131°F) Storage Temperature: -20° +80°C (-4° +175°F) Max. Rel. Humidity: 50°C (non-condensing) Number Devices, Stacked Installation Certifications rail included mounting bracket Ambient Temperature Rating 55°C 50°C 45°C Load Specification Output Protection Circuitry Output Response Time Adjustments Indicators Construction Environmental Rating Connections Operating Conditions page Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Dual-Discrete Outputs Expert Fiber-Optic Sensor Programming Options Light/Dark Operate Selection OFF-Delay Timing Selection Display Selection Power Level/Speed Selection Response* Repeatability Color Fiber PIT16U PIT26U PIT46U PIT66U PBT16U PBT26U PBT46U PBT66U PIT16U PIT26U Green PIT46U PIT66U PBT16U PBT26U PBT46U PBT66U Tracking Feature Toggle select condition which each output will conduct: when target present when target absent. Programmable OFF-delay pulse stretcher: milliseconds Discrete Output: signal value excess signal Super High-Speed High-Speed 1000 High-Power 1000 1700 Super High-Power 1200 2400 Maximum Range* Sets Output identical settings Output Output settings then revised desired. (See Advanced Setup procedure, page following settings preset factory; revert sensor factory defaults using Advanced Setup procedure (page Light operate (lo) Output displayed Analog: full scale delay High Speed (HS); response Discrete: switch-point positioned signal value (1234) Maximum power setting middle range Factory Default Settings Diffuse mode performance based reflectance white test card. bifurcated fiber recommended these speed settings. Contact Banner Applications more information. note page Programming Programming Procedures push buttons, Dynamic Static (-), used access programming parameters. remote programming, connect switch digital input gray wire; length individual pulses equal value 0.04 seconds seconds Returning mode TEACH SETUP modes each exited ways: exercising 60second time-out, cancelling process. TEACH mode, sensor will return mode without saving settings; SETUP mode, sensor will return mode save settings. cancel TEACH mode, press hold Static button seconds; cancel SETUP mode, press hold both Static Dynamic buttons seconds. Output set-point(s) each output independently another (see Super-HighSpeed Operation). However, functional range available output dictated automatic power gain settings established output Whenever output taught, output also must retaught. Applications hint: teach weakest signal output first. page Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Expert Fiber-Optic Sensor Active Channel Select Selects which channel teach displays channel configuration information. Action Push Button Display Shows Dual-Discrete Outputs Single-Click Single-click both Dynamic Static buttons concurrently. Pointer icon: moves other channel indicator. Remote Triple-pulse remote line. Static TEACH Two-point TEACH single threshold. Threshold adjustable using buttons (see Manual Adjust, page Action Remote Push Button Remote Push Button Press Hold Display Shows Press hold Static button. action required; sensor automatically ready TEACH condition. Single-Click flashes "1st" background turns Present Output target. Click Static button. flashes "2nd" Present Output target. Single-pulse remote line. TEACH conditions acceptable: background turns green flashes "pass," followed Present Output target. number (denoting contrast); Click Static button. table right. Sensor returns mode with settings. TEACH conditions unacceptable: flashes "fail" returns "1st" background remains Present Output target. After seconds, sensor returns Single-pulse remote line. mode (LCD background turns green) without changing settings. Contrast Values Excellent Good Marginal Push Button Single-Click Remote page Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Dual-Discrete Outputs Dynamic TEACH Expert Fiber-Optic Sensor TEACH on-the-fly; sets single threshold. Threshold adjustable using buttons (see Manual Adjust, page Action Push Button Press Hold Display Shows Press hold Dynamic button. shows "dyn" background turns Hold remote line ground). Push Button Remote Hold Present Output ON/OFF conditions. Continue hold Dynamic button. Present Output ON/OFF conditions. Continue hold remote line ground). TEACH conditions acceptable: background turns green flashes "pass," followed number (denoting contrast); table left. Sensor returns mode with settings. TEACH conditions unacceptable: flashes "fail" background remains Sensor returns mode (LCD background turns green) without changing settings. Excellent Good Marginal Push Button Contrast Values Remote Release Release Dynamic button. Remote Release remote line/switch. Single-Point Static TEACH Used single condition. other conditions (both lighter darker) will result output. Target condition sensitivity adjustable using buttons (see Manual Adjust, page Action Push Button Press Hold Display Shows Press hold Static button. flashes "1st" background turns Remote Present target learn, single-pulse remote line. flashes "2nd" background turns TEACH conditions acceptable: background turns green flashes "sngl," then "pt" twice Sensor returns mode with settings. TEACH conditions unacceptable: flashes "fail" returns "1st" background remains After seconds, sensor returns mode (LCD background turns green) without changing settings. Push Button Double-Click Present target learn, double-click Static button. Remote Double-pulse remote line. Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 page Expert Fiber-Optic Sensor Manual Adjust Dual-Discrete Outputs used time sensor mode, fine-tune sensing thresholds adjust sensitivity singlepoint target conditions. Action Single-Click Display Shows Click increase, click decrease, threshold set-point value Click increase, click decrease, tolerance single-point target condition. available with remote programming. Push Button display briefly flashes threshold set-point value being changed. display flashes "inc" "dec" single-point tolerance adjusted. Single-Click Remote Setup Configure sensor display operating parameters. Click Dynamic double-pulse remote line select option. Click Static single-pulse remote line advance. Changes updated instantly. Action Push Button Press Hold Display Shows Press hold both Dynamic Static buttons concurrently. background turns Double-pulse remote line. Remote Select Light/Dark Operate SingleClick Click Single- Click Dynamic toggle between selections. Click Static save selection advance "OFF-Delay." Double-pulse remote line toggle between selections. Single-pulse remote line save selection advance "OFF-Delay." Push Button Light Operate: display flashes "lo" icon Dark Operate: display flashes "do" icon Remote Select OFF-Delay Timing Enable SingleClick SingleClick Click Dynamic toggle between selections. Click Static save selection advance "Display." Double-pulse remote line toggle between selections. Single-pulse remote line save selection advance "Display." Push Button OFF-Delay): Clock icon OFF-Delay: 10," 15," 20," 30," 40," 60," 80," "t100" Clock icon Remote page Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Dual-Discrete Outputs Setup (continued) Action Select Display Parameters SingleClick SingleClick Expert Fiber-Optic Sensor Display Shows Click Dynamic toggle between selections. Click Static save selection advance "Power/Speed." Double-pulse remote line toggle between selections. Single-pulse remote line save selection advance "Power/Speed." Push Button signal value: 1234 Percent excess signal: 123P Remote Select Power Speed Combination SingleClick SingleClick Click Dynamic toggle between selections. Click Static save selection return mode. Double-pulse remote line toggle between selections. Single-pulse remote line save selection return mode. Push Button Super-high-speed (50-µs response) High-speed (200-µs response) High-power (1-ms response) Super-high-power (2.5-ms response) Remote Super-High-Speed Operation Note: Under most operating conditions, D10's discrete outputs operate independently another. However, extremely fast microsecond response time, D10's outputs become complementary when operating Super-High-Speed. Only channel then taught adjusted; channel automatically becomes complementary Specifically, output will conduct when sensor sees taught condition, output conducts state. invert these conditions (output condition output ON), toggle light/dark operate SETUP menu (page Push-Button Lockout Prevents unwanted adjustments tampering push buttons. Push buttons enabled disabled only from remote line only during normal mode. Action Push Button Display Shows Push Buttons Disabled: flashes "loc" Padlock icon appears Sensor remains mode Push Buttons Enabled: flashes "uloc" Padlock icon disappears Sensor remains mode available with pushbutton programming. Quad-pulse remote line while mode toggle between selectons. Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Remote page Expert Fiber-Optic Sensor Advanced Setup Dual-Discrete Outputs Advanced adjustments previously configured sensor display operating parameters. Quad-click Static quadpulse remote line before exiting "Power Speed" settings enter this mode. Click Dynamic double-pulse remote line select option. Click Static single-pulse remote line advance. Changes updated instantly. Action Enter SETUP Mode (from "Power Speed" mode) Push Button Quad-Click Display Shows Quad-click Static button. background remains displays "Tracking Enable" option. Remote Quad-pulse remote line. Tracking Enable (sets output identical output Click Dynamic toggle between selections. Click Static save selection advance "Factory Default." Double-pulse remote line toggle between selections. Single-pulse remote line save selection advance "Factory Default." Push Button SingleClick Click Single- Tracking disabled: display shows Tracking enabled: display shows Remote page Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Dual-Discrete Outputs Advanced Setup (continued) Action Factory Default Settings (returns sensor factory default settings) Expert Fiber-Optic Sensor Display Shows SingleClick SingleClick Click Dynamic toggle between selections. Click Static advance "Display Orientation." Push Button Factory Default Settings Selected: display shows Factory Default Settings Selected: display shows Remote Double-pulse remote line toggle between selections. Single-pulse remote line advance "Display Orientation." Display Orientation (inverts display read "upside-down") Push Button Normal: example: 1234 1234 NOTE: Icons channel indicators invert page Inverted: example: SingleClick Click Single- Click Dynamic toggle between selections. Click Static return mode. Double-pulse remote line toggle between selections. Single-pulse remote line return mode. Remote Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Expert Fiber-Optic Sensor Dimensions Dual-Discrete Outputs 61.3 (2.42") 68.1 (2.68") (0.30") 35.9 (1.41") 10.0 (0.39") Mounting Bracket (included) Slide Release Fibers (0.39") 16.4 (0.64") Plastic Fiber Emitter Port Plastic Fiber Receiver Port 78.4 (3.09") 84.4 (3.32") (0.34") 10.0 (0.39") (0.20") (0.14") (0.20") (0.10") 35.1 (1.38") 15.2 (0.60") 16.0 (0.63") 25.4 (1.00") (0.13") 10.0 (0.39") (0.13") C'sink (0.31") (0.13") deep (0.18") thru page Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 Dual-Discrete Outputs Hookups D10DNFP(Q) Load Load 12-24V Teach Gate Expert Fiber-Optic Sensor D10DPFP(Q) Load Load 12-24V Teach Gate NOTE: Hookups identical. Dynamic TEACH Adaptive Thresholds Dynamic TEACH used program sensitivity during actual machine conditions. During Dynamic TEACH, takes multiple samples light dark conditions automatically sets sensitivity optimum level. Dynamic TEACH activates sensor's adaptive threshold system, which continuously tracks minimum maximum signal levels, automatically maintains centering switch point between light dark conditions. adaptive threshold system remains effect during mode automatically adjust changes light dark conditions. adaptive routine saves non-volatile memory least once hour. When Dynamic TEACH mode used program sensitivity, output state (light dark operate) will remain last programmed. change either light dark operate, SETUP mode (see page Sensitivity adjusted time when sensor mode clicking buttons. However, when manual adjustment made, adaptive threshold system disabled (cancelled). Self-Diagnostic Error Modes unlikely event that setup parameters lost become corrupt, display will continuously scroll: Error." Reteach sensor recover. problem persists, contact your Banner representative further information. Gate Input D10's pink wire configured gate input. When this wire pulled (i.e., sensor ground), inhibits outputs from switching, while other functions continue enabled. This feature useful controlling when outputs allowed change states. Gate input function response time millisecond. Banner Engineering Corp. Minneapolis, U.S.A. www.bannerengineering.com Tel: 763.544.3164 page Expert Fiber-Optic Sensor Accessories Pico-Style Quick-Disconnect Cables Cable: jacket, polyurethane connector body, snap-lock coupling Conductors: high-flex stranded, gold-plated contacts Temperature: -40° +90°C (-40° +194°F) Voltage Rating: ac/36V Dual-Discrete Outputs Style 6-Pin Straight Model PKG6Z-2 PKG6Z-9 PKW6Z-2 Length (6.5') (30') (6.5') Dimensions max. (0.4") Pin-out max. (1.1") Brown Wire Gray Wire White Wire Blue Wire Black Wire max. (1.0") (0.8") Pink Wire 6-Pin Right-angle PKW6Z-9 (30') max. (0.5") Repairs NOTE: attempt repairs D10. contains field-replaceable components. Return sensor factory warranty repair replacement. ever becomes necessary return factory, please following: Contact Banner Factory Application Engineering Group address numbers listed bottom back page. They will attempt troubleshoot system from your description problem. they conclude that component defective, they will issue (Return Merchandise Authorization) number your paperwork, give proper shipping address. Pack carefully. Damage which occurs return shipping covered warranty. WARNING Used Personnel Protection Never this product sensing device personnel protection. Doing could lead serious injury death. This product does include self-checking redundant circuitry necessary allow personnel safety applications. sensor failure malfunction cause either energized de-energized sensor output condition. Consult your current Banner Safety Products catalog safety products which meet OSHA, ANSI standards personnel protection. WARRANTY: Banner Engineering Corp. warrants products free from defects year. Banner Engineering Corp. will repair replace, free charge, product manufacture found defective time returned factory during warranty period. This warranty does cover damage liability improper application Banner products. This warranty lieu other warranty either expressed implied. Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, 55441 Phone: 763.544.3164 www.bannerengineering.com E-mail: sensors@baneng.com Other recent searchesZX30-20-4+ - ZX30-20-4+ ZX30-20-4+ Datasheet ZFx86 - ZFx86 ZFx86 Datasheet VN2010L - VN2010L VN2010L Datasheet BS107 - BS107 BS107 Datasheet HYMD264G726D - HYMD264G726D HYMD264G726D Datasheet HV7100 - HV7100 HV7100 Datasheet HDLx-2416 - HDLx-2416 HDLx-2416 Datasheet DS1673 - DS1673 DS1673 Datasheet CS5342 - CS5342 CS5342 Datasheet
Privacy Policy | Disclaimer |