| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Order on-line www.datel.com ACA5-20PC Series E156931 Di
Top Searches for this datasheetOrder on-line www.datel.com ACA5-20PC Series E156931 Digital-Readout LED-Display 50-2000A Ammeters ACA5-20PC Series Ammeters designed scale digitally display output standard, 5A-output current transformers (50:5A, 500:5A, 1000:5A, etc.). Simply pass secondary/output wires "primary" through ACA5-20PC's on-board apply power meter, you're instantly measuring currents over ranges from 0-50A (with 100mA resolution) 0-2000A (with resolution). Because they accept outputs from previously installed high-current CT's, ACA5-20PC's instantly bring modern digital precision older ammeters. functionally complete ACA5-20PC ammeters incorporate scaling/interface circuitry mate on-board precision digit) converter. A/D's output directly drives meters' large (0.37"/9.4mm digit height), easy-to-read, displays. models employ auto-zero circuits, precision bandgap references, super stable metal-film resistors unsurpassed accuracy (±0.15%FS) stability. ACA5-20PC meters either (120/220/277Vac 50/60Hz 120Vac 400Hz) (+5V, +5-40V, +36-75V) powered. models powered same supply whose current they monitoring. ACA5-20PC's provide 2000Vdc isolation between measured current their power supply, models UL/CSA recognized. Each meter housed subminiature, 1.38" 0.88", epoxy-encapsulated package whose behind-the-panel installation depth inches. Display color options include standard red, high-intensity red, standard green. Each meter supplied with plastic bezel assembly with sealing gaskets (DATEL DMS-BZL4). Features Scales displays output 50:5A 2000:5A current transformers ranges (0-50 0-2000 Amp) options, power options, models Functionally complete: On-board current transformers Scaling/interface circuitry Precision converters Bright green displays Subminiature, 1.38" 0.88" package Easy-to-read, 0.37"/9.4mm digits powered models: 120Vac 400Hz, 120/220/277Vac 50/60Hz models "self-powered" powered models: +5V, +5-40V, +36-75V 2000V isolation; UL/CSA recognized Digital replacements analog ammeters CAL. DIGIT CONVERTER PRECISION FULL-WAVE RECTIFIER DISPLAY (L1) POWER CONVERTER BUILT-IN 0-5A CURRENT TRANSFORMER OUTPUT FROM 50:5A 2000:5A EXTERNAL CURRENT TRANSFORMER INPUT POWER Figure ACA5-20PC Series Simplified Schematic DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E-mail: sales@datel.com Internet: www.datel.com ACA5-20PC Series Performance/Functional Specifications Typical 25°C, unless otherwise noted. Rated Full-Scale Current Models Overcurrent Rating Performance Sampling Rate Accuracy Measurement Type Temperature Drift +60°C) Zero-Current Reading Dielectric Withstanding Voltage Power Supply Voltage ACA5-20PC-X-AC1-XX ACA5-20PC-X-AC2-XX ACA5-20PC-X-AC3-XX ACA5-20PC-X-DC1-XX ACA5-20PC-X-DC2-XX ACA5-20PC-X-DC3-XX Power Supply Current ACA5-20PC-X-AC1,3-XX ACA5-20PC-X-AC2-XX ACA5-20PC-X-DC1,2-XX ACA5-20PC-X-DC3-XX Power Supply Terminal Block Wire Size Type Insulation Strip Length Screw Tightening Torque Maximum Rated Voltage Display Display Type Size Overrange Indication Display Reading/Decimal Point Physical/Environmental Operating Temperature Storage Temperature Humidity (non-condensing) Case Material Dimensions Weight (all models) +4.75 +4.75 -001 2000 Min. Typ. Order on-line www.datel.com Max. Units Amps Ordering Information rated full-scale current samples second ±0.15%FS counts Sine wave input, full-wave averaging, calibrated ±0.2 ±0.4 +5.25 +120 Counts/°C Counts Vac@47-99Hz Vac@350-450Hz Vac@47-99Hz mA@47-99Hz mA@350-450Hz mAdc mAdc ACA5 20PC Input Range: 50.0A 75.0A 100.0A 150.0A 199.9A 250A 300A 400A 500A 600A 750A 1000A 1500A 1999A Color: Standard High-Intensity Red* Green Standard* Available "DC3" Power Supply: 85-264Vac@50/60Hz 85-140Vac@400Hz 240-310Vac@50/60Hz +5-40Vdc +36-75Vdc +5Vdc powered models only Accessories: DMS-20-CP Panel cutout punch DMS-BZL4 bezel assembly with sealing gasket supplied with each ammeter. Technical Notes IMPORTANT! ensure safe reliable operation, ACA5-20PC ammeters must installed serviced qualified technical personnel. Contact DATEL there doubt regarding ammeter installation and/or operation. Measurement Type: ACA5-20PC ammeters employ full-waverectified, average responding, rms-calibrated circuit measure stepped-down output their built-in current transformer (CT) Stated accuracy specifications measured using sine-wave current close full-scale input level, nominal line frequency. Calibration: Periodic recalibration ACA5-20PC ammeters required under normal, indoor operating environments. user calibration necessary, should performed qualified technical personnel. Calibration performed with potentially lethal voltages applied ACA5-20PC associated wiring, with specified full-scale current flowing through ammeter's built-in current transformer. plastic, fully-insulated adjusting tool must used access recessed calibration potentiometer located back meter (see Mechanical Specifications). Contact DATEL additional information required regarding calibration, setup, other technical issue pertaining ACA5-20PC ammeters. Wire Gauges Fusing: Wires specified Functional Specifications section must used making connections ACA520PC Series ammeters. power-supply load wiring must rated supply voltages currents they will conduct must comply with code application-mandated requirements pertaining user's specific installation. 16-22AWG (solid stranded) 0.25 inches pound-inches (0.4Nm) 310Vac digit LED, 0.37"/9.4mm digit height Model dependent. Ordering Info. Polycarbonate 1.38"W 0.88"H Depth model dependent (see Mechanical Specifications) ounces grams) specified Full-Scale Current current carried single wire passing through center hole ACA5-20PC's on-board load current ultimately being measured. Overcurrent Rating continuous rating that applies Full-Scale Current. does apply circuitry external meter. Listed accuracy specifications apply over range Rated Full-Scale Current over frequencies 45-450Hz. Maximum reverse polarity protection "DC1" models -40Vdc, -50Vdc "DC2" models. "DC3" models provide reverse polarity protection. specified maximum power supply currents steady-state. AC-powered models draw larger surges initial turn DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E-mail: sales@datel.com Internet: www.datel.com ACA5-20PC Series supply wires connected both meter load must fused according current rating wire gauge being used, accordance with applicable regulatory codes. Also, wire insulation should stripped within +/-10% stated dimensions, wires should inserted into such that their insulation pinched screw terminal. used only powering meter's internal circuitry. must used supply current external loads. AC-powered models draw minimal steady-state supply currents (50mA max.), most applications, they fused according supply wire's maximum amperage rating. However, these models draw significantly higher surge currents brief periods when line voltage initially applied. Supply Polarity Grounding: supply inputs, TB1-A TB1-B, ac-powered ACA5-20PC ammeters themselves polarity sensitive, that they have internal designations. Also, ac-powered ACA5-20PC ammeters include require connection earth/chassis ground. Connector Torque Ratings: important tighten TB1's, screwterminals their rated torque specification pound-inches (0.4Nm). Proper tightening will minimize connector losses ensure safe, reliable operation. DC-Powered Models: DC-powered models draw minimal supply currents (120mA max.) most applications fused according supply wire's maximum amperage rating. However, sure check comply with applicable codes regulations ensure proper installation operation. Isolation: on-board (L1) provides minimum 2000Vdc Panel Installation connections ACA5-20PC Series ammeters must made after ammeter securely attached panel with load supply voltages de-energized (off). Care should exercised when passing conductors through ammeter's built-in installed wire positions should such that minimal forces applied built-in TB1, ammeter itself. high-vibration environments, proper strain reliefs used load supply wiring. ensure secure panel-mount installation, DATEL recommends Step PANEL isolation between current-carrying conductor passing through primary circuit ammeter supply voltage connected TB1. This isolation rating only applies applications which load wiring (i.e., wire passing through L1's center hole) does connect directly indirectly TB1-A TB1-B. Precautions: normal operation, current transformer's secondary circuit operates very voltage closed-loop operation burden resistance. However, still generate potentially lethal voltages output current suddenly interrupted. example, loose secondary connections cause condition referred "inductive kick". Inductive kick generate extremely high voltages across intermitent secondary connections. Therefore, implementing connections current transformer's output leads must only performed with zero load-current, that with power applied load circuit. Connections Grounding: Some applications require connecting external CT's output leads earth/chassis ground. USA, consult latest revision National Electrical Code (NEC) more information regarding grounding. After mechanical assembly completed, connect output leads external each other after they through L1's center hole. Pressure-style connectors (commonly refered "wire nuts") acceptable long they rated number conductors voltage invloved. Replacing Analog Panel Meters: ACA5-20PC ammeters used direct replacements analog panel meters driven CT's. wiring operations must performed with both load supply power sources completely de-energized. using DMS-BZL4 bezel assembly (with sealing gasket) supplied with each ammeter. Mechanical Specifications detailed cutout ammeter dimensions. Following four-step sequence shown Figure -being careful apply excessive force twisting motions-insert ammeter into panel opening. When using DMS-BZL4, install sealing gasket positioned between ammeter's front flange panel front surface (see Mechanical Specifications). sure securely tighten four screws supplied with bezel assembly. Step Step PANEL Step PANEL BEZEL PANEL GASKET (optional) Figure Panel Installation DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E-mail: sales@datel.com Internet: www.datel.com ACA5-20PC Series Typical Wiring Diagrams First pass carefully dress output wire from external through on-board (L1). Then connect supply shown. required, verify that correct line-power polarities applied external load (see Technical Note Ensure wires stripped terminals torqued correctly. proper operation, pass only single wire through on-board CT's center hole. POWER SUPPLY ACA5-20PC-X-ACX LOAD 0-5A OUTPUT EXTERNAL 5A-OUTPUT CURRENT TRANSFORMER Figure ACA5-20PC AC-Powered Models First pass carefully dress output wire from external through on-board (L1). Then connect powersupply wires TB1, observing correct positive ("+") negative ("-") polarities. Ensure wires stripped terminals torqued correctly. proper operation, pass only single wire through on-board CT's center hole. ACA5-20PC-X-DCX POWER SUPPLY LOAD 0-5A OUTPUT EXTERNAL 5A-OUTPUT CURRENT TRANSFORMER Figure ACA5-20PC DC-Powered Models DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E-mail: sales@datel.com Internet: www.datel.com ACA5-20PC Series Mechanical Specifications Mechanical Dimensions: Inches (mm) Tolerances: ±0.02 (±0.51), ±0.010 (±0.254) BEZEL INSTALLATION Hole Diameter: 0.27 (6.9) min. 2.01 (51.1) 0.040 (1.02) 1.00 (25.4) PANEL 0.040 (1.02) 1.30 (33.0) 1.38 (35.1) 0.040 (1.02) 0.80 (20.3) 0.88 (22.4) 1.32 (33.5) FRONT VIEW BACK VIEW GASKET (optional) BEZEL CAL. DMS-BZL4 BEZEL #2-56 INSERT 0.156 (3.96) DEEP FRONT VIEW 0.187 (4.75) RECOMMENDED DRILL PANEL CUTOUT DIMENSIONS 0.093 (2.362) DIAMETER REQUIRED) ONLY WHEN USING SUPPLIED BEZEL ASSEMBLY INTERNAL CORNER RADII: 0.032 (0.81) MAX. 0.116 (2.95) 1.280 (32.51) 1.07 (27.18) 0.838 (21.29) 1.336 (33.93) 0.145 (3.68) 1.826 (46.38) 1.626 (41.30) 9001 REGISTERED DS-0446A 05/2000 DATEL, Inc. Cabot Boulevard, Mansfield, 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: sales@datel.com DATEL (UK) LTD. Tadley, England Tel: (01256)-880444 DATEL S.A.R.L. Montigny Bretonneux, France Tel: 01-34-60-01-01 DATEL GmbH Germany Tel: 89-544334-0 DATEL Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-354-2025 DATEL makes representation that products circuits described herein, other technical information contained herein, will infringe upon existing future patent rights. descriptions contained herein imply granting licenses make, use, sell equipment constructed accordance therewith. Specifications subject change without notice. DATEL logo registered DATEL, Inc. trademark. Other recent searchesSQM40N10-30 - SQM40N10-30 SQM40N10-30 Datasheet PDNL-30-500 - PDNL-30-500 PDNL-30-500 Datasheet MC68HC912DG128 - MC68HC912DG128 MC68HC912DG128 Datasheet ISL5729 - ISL5729 ISL5729 Datasheet EPM3128A - EPM3128A EPM3128A Datasheet 1SS369 - 1SS369 1SS369 Datasheet
Privacy Policy | Disclaimer |