| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Highly Visible Display with 2-color (Red Green) LEDs Contact, NPN
Top Searches for this datasheetFrequency/Rate Meter Highly Visible Display with 2-color (Red Green) LEDs Contact, NPN, PNP, voltage pulse input. Front-panel operation easy setting. Average processing function suppresses flicker. Includes scaling, auto-zero time, startup compen- K3MA-F sation time functions. Easy confirmation max/min display. Short 80-mm depth (measured from edge face plate). Finger protective cover (standard equipment) guards against electric shock. Water- dust-proof NEMA4X (IP66 equivalent) front panel. Recognized U.S. Canadian requirements under Component Recognition Program with marking. Ordering Information Input type Rotary pulse Supply voltage VAC/VDC None None Output Model K3MA-F 100-240VAC K3MA-F 24VAC/VDC relay contact outputs (SPST-NO) K3MA-F-A2 100-240VAC relay contact outputs (SPST-NO) K3MA-F-A2 24VAC/VDC Model Number Legend: K3MA-F-@ Input Type Rotary pulse Output Type None: output relay contact outputs (SPST-NO) Supply Voltage 100-240VAC: 24VAC/VDC: VAC/VDC K3MA-F K3MA-F Specifications Ratings Model K3MA-F 100-240VDC, K3MA-F-A2 100-240VAC 110% rated supply voltage max. K3MA-F 24VAC/VDC, K3MA-F-A2 24VAC/VDC VAC/VDC max. VAC) max. VDC) Supply voltage Operating voltage range Power consumption (under maximum load) Insulation resistance min. VDC) between external terminal case. Insulation provided between inputs, outputs, power supply. Dielectric withstand voltage 2,000 between external terminal case. Insulation provided between inputs, outputs, power supply. Noise immunity 1,500 power supply terminals normal common mode. square-wave noise with Vibration: Acceleration: m/s2 power supply terminals normal mode. 1,500 common mode. square-wave noise with Vibration resistance Shock resistance Ambient temperature Approved safety standards each directions sweeps. m/s2 (100 m/s2 relay contact outputs) times each axes, directions. Operating: Storage: -10C (with condensation icing) -25C (with condensation icing) UL3121, conforms EN61010-1 (Pollution degree 2/overvoltage category Conforms VDE0106/P100 (finger protection) (EMI) Emission Enclosure: Emission Mains: (EMS) Immunity ESD: Immunity RF-interference: Electrical Fast Transient Noise: Immunity Burst Noise: Immunity Surge: Immunity Conducted Disturbance: Immunity Voltage Dip/Interrupting: EN61326+A1 Industry CISPR Group class CISRP16-1/-2 CISPR Group class CISRP16-1/-2 EN61326+A1 Industry EN61000-4-2: 4-kV contact discharge 8-kV discharge EN61000-4-3: (amplitude-modulated, GHz) EN61000-4-4: (power line) line line (I/O signal line) EN61000-4-5: (power line) 2-kV line ground (power line) EN61000-4-6: (0.15 MHz) EN61000-4-11: cycle, 100% (rated voltage) Weight Approx. Input/Output Ratings Relay Contact Output Item Rated load Rated carry current Max. contact voltage Max. contact current Max. switching capacity Min. permissible load level, reference value) Mechanical life Electrical life ambient temperature Resistive load (cos VAC, max. terminal) VAC, terminal) 1,250 5,000,000 times min. switching frequency 1,200 times/min) 100,000 times min. rated load switching frequency times/min) Inductive load (cos 0.4, VAC, Measuring Ranges Input Measuring range Measuring accuracy Displayable range -19999 99999 (with scaling function) No-voltage Contact/Open Collector Inputs No-voltage contact max.) with 0.05 30.00 ON/OFF pulse width min. Open collector max.) with 0.05 5000.0 pulse width min. 0.1% digit max. 235C) K3MA-F K3MA-F Characteristics No-voltage contact max., ON/OFF pulse width: min.) Voltage pulse max., ON/OFF pulse width: min., voltage: V/OFF voltage: Input signal Open collector max., ON/OFF pulse width min.) Connectable Sensors residual voltage: leakage current: Load current: Measuring accuracy Measurement method Max. displayed digits Display Polarity display Zero display Scaling function Hold function Hysteresis setting Other functions max. max. Must have switching capacity min. Must able dependably switch load current max. 0.1%FS digit 235C) Cycle measurement digits 19999 99999) 7-segment digital display, Character height: 14.2 displayed automatically with negative input signal. Leading zeros displayed. Programmable with front-panel inputs (range display: 19999 99999). decimal point position desired. hold (maximum value), hold (minimum value) Programmable with front-panel inputs (0001 9999). Scaling teach function Display color change (green (red), green, (green), red) type change (upper limit, lower limit, upper/lower limit) Average processing (simple average OFF/2/4/8 operations) Auto-zero time Startup compensation time Setting change lockout Parameter initialization Display auto-return time Relays: SPST-NO max. Front panel: NEMA4X indoor (equivalent IP66) Rear case: standard IP20 Terminals: standard IP00 finger protection (VDE0106/100) Non-volatile memory (EEPROM) (possible rewrite 100,000 times) Output Delay comparative outputs Enclosure ratings Memory protection K3MA-F K3MA-F Nomenclature Operation indicators Main indicator Level indicator MAX/MIN LEVEL MODE SHIFT MAX/MIN Level Mode Shift Name Main indicator Opera- tion indi- cators Level indicator MAX/MIN Level Mode Shift when output when output when value being displayed changed. Functions Displays current values, parameters, values. when main indicator showing value. when main indicator showing value. when teaching function operable. Blinks while teaching function operating. Displays current level that K3MA-F (See below details.) Used display values when measurement value being displayed. Used change level. Used allow main indicator indicate parameters sequentially. Used enable value changed. When changing value, this used move along digits. Used change value. Used clear forced-zero function when measurement value being displayed. Level Protect Operation Initial setting Advanced-function setting Level indicator Operation Main Functions Frequency range (setting parameter) Function Selects pulse input signal. Input range (setting parameters) 0.05 0.05 Setting range Displayable from 19999 99999 with scaling function. position decimal point desired. Input Types Ranges Pulse frequency selection Pulse Frequency Selection Parameter Setting value Meaning 0.05 measurement range 0.05 measurement range Note: initial value "0.05 (B)." K3MA-F Scaling K3MA-F When desired display value corresponding input, value will displayed line between points determining zero point. Parameter Setting value Meaning Input value Display value Parameter Setting value Meaning Display four digits after decimal point Display three digits after decimal point Display digits after decimal point Display digit after decimal point decimal point Display value DISPLAY decimal point optionally displayed. When displaying decimal point, consider number digits follow decimal point prior setting scaling display value. INPUT Input value Teaching with actual values possible. Instead setting inputting with Shift Key, current values input scaling input values teaching. This useful making settings while checking operation status K3MA-F. Convenient Functions Scaling Teach parameter (@EG) K3MA-F's initial setting level using actual input values with teaching function. After displaying parameter, actual input settings made with following operation. Teaching mode Monitor mode flashes. register shift monitor mode. shift next parameter without registering. lights indicate that parameter valid teaching. Normal change turns OFF. Next parameter Types (Comparative Output Models Only) operate three following modes accordance with compared values: Upper limit (High Acting): output turned when measurement value greater than value. Lower limit (Low Acting): output turned when measurement value less than value. Upper lower limits (Outside Band Acting): upper limit value) lower limit value) independently. output turned when measurement value greater than upper-limit value less than lower-limit value. K3MA-F Upper Limit (High Acting) Lower Limit (Low Acting) Upper Lower Limits (Outside Band Acting) OUT1 upper-limit value Measurement value Hysteresis OUT1 lower-limit value Output K3MA-F OUT1 value Measurement value Hysteresis Measurement value OUT1 value Hysteresis Hysteresis Output Output three types output operations shown above combined desired. following examples possible combinations. Upper Limit 2-stage Output Threshold Output OUT2 upper-limit value Combination Upper Limit Upper/Lower Limits Measurement value OUT2 upper-limit value OUT1 value Measurement value OUT2 lower-limit value OUT2 value Measurement value OUT1 upper-limit value OUT1 lower-limit value OUT2 lower-limit value OUT1 value OUT2 OUT1 OUT2 OUT1 OUT2 OUT1 Parameter Initialization This function returns parameters their initial values. Parameter @E@Q Setting value Meaning -Initializes parameters. Auto-zero Time This function sets time display return zero when input pulses stop. time longer than expected input pulse cycle (the interval between input pulse next). Proper measurement possible time shorter than input pulse cycle. Startup Compensation Time startup compensation time cancels measurement predetermined time when turning power prevent unwanted output temporary input fluctuations. Display Lower limit setting (OUT2) Startup compensation time this reset K3MA-F after returning factory-set condition. Average Processing Average processing stabilizes display minimizing pulsating flicker caused fluctuations pulse width sensor input eccentricity rotating shafts. 00000 displayed Power supply OUT2 output Time Hysteresis (Comparative Output Models Only) hysteresis comparative outputs prevent chattering output when measurement value fluctuates finely near value. Changing Display Color color value displayed either green. comparative output models, display color change from green red, from green, according status comparison criterion. Upper limit (high acting) value Measurement value Hysteresis OUT1 value Green 113.36 100.05 OUT2 value Output 8.781 K3MA-F Display Auto-return Time This function automatically returns display operation level's current value keys pressed preset time (called display auto-return time). K3MA-F MAX/MIN Display maximum minimum measurement (display) values from time power turned until current time stored displayed. This useful, example, when measuring maximum value. Current value Move-to-Protect-Level Time time required shift protect level desired. MAX/MIN MAX/MIN LEVEL MODE SHIFT value MAX/MIN MAX/MIN LEVEL MODE SHIFT value MAX/MIN MAX/MIN LEVEL MODE SHIFT External Connections Terminal Arrangement Power supply Output terminals Input terminals Sensor power supply Models with comparative output 100- 240-VAC type 24-VAC/VDC type polarity 24-VDC connection.) OUT1 OUT2 Note: Refer Input Circuits page Terminal Name Operation power Description Connects operation power supply. No-voltage contact/open collector input Outputs relay outputs. power supply sensors. Pulse input Outputs Sensor power supply K3MA-F K3MA-F Input Circuits Pulse Input NPN, contact input Pulse detection circuit Voltage detection circuit PNP, voltage pulse input Voltage pulse negative pole sensor power supply connected internally. Block Diagram Input Input circuit Microcomputer Display Output circuit Contact output (See note.) EEPROM Constant voltage circuit Power supply circuit Note: Relay output models only. K3MA-F K3MA-F Levels "Level" refers grouping parameters. following table lists operations that possible each levels, diagram tells move between levels. There some parameters that displayed certain models. Level name Protect Operation Initial setting Advanced-function setting Setting lockouts. Displaying current values, setting values. Function Continue Continue Measurement Making initial settings input type, scaling, output operating Stopped tion, other parameters. Setting average processing, display color settings, other Stopped vanced-function parameters. Power Operation level Time user (See note.) min. Protect level min. min. Flashing stops released. -1234.5 Continue press min. Indicates change level. Initial setting level Password "-0169" min. Advanced-function setting level Note: move-to-protect-level time advanced-function setting level. K3MA-F K3MA-F Parameters Note: Some parameters displayed certain models. K3MA-F will stop measurement level changed initial setting level advanced-function setting level. input range changed, some parameters default values. Therefore, input range first. Settings displayed reversed colors initial settings. Power Operation level Current value models with comparative output function. MODE OUT1 value MODE these. OUT1 upper-limit value MODE OUT1 lower-limit value MODE OUT2 value MODE these. OUT2 upper-limit value MODE OUT2 lower-limit value MODE K3MA-F K3MA-F Press Level more than Initial setting level Press Level less than Pulse frequency MODE Scaling input value Press Level less than Advanced-function setting level Pulse frequency Enter password "-0169" Scaling Parameter initialization Unit: times Comparative hysteresis MODE Average processing MODE Models with comparative output function OUT1 hysteresis MODE Scaling display value MODE OUT2 hysteresis MODE Decimal point position MODE Auto-zero time MODE OUT1 type Upper Limit Lower Limit Upper/Lower Limits MODE Startup compensation time Models with comparative output function MODE OUT2 type Upper Limit Lower Limit Upper/Lower Limits MODE Green (red) Display color change Green (green) MODE Move advancedfunction setting level MODE Display auto-return time MODE MODE Move-toprotectlevel time Unit: MODE Unit: Settings displayed reversed colors initial settings. K3MA-F Press Operation level Press Level than preset time. Mode more Level Mode more than K3MA-F Protect level Operation/adjustment lockouts MODE Setting level lockouts MODE Setting change lockout MODE Operation/Adjustment Lockouts Restricts operations operation level adjustment level. Parameter Setting Operation level Current value display value display Allowed Allowed Prohibited Initial Settings Power F2GQ Allowed Allowed Allowed Press Level level. min. move initial setting Initial setting This displayed models with comparative output function. Select pulse frequency measurement. scaling values type required. Setting Level Lockouts Restricts shifting initial setting level advanced-function setting level. Parameter Setting Shift initial setting level Shift advancedfunction setting level Allowed Prohibited Prohibited Press Level operation level. less than min. return required, shift advanced-function setting level number measurements average processing, hysteresis values, auto-zero time, startup compensation time, display color change, display auto-return time, move-toprotect-level time. @4GQ Allowed Allowed Prohibited Setting Change Lockout Restricts setting changes operation. When this lockout set, longer possible shift setting change mode. Parameter Setting Setting change operation Allowed Prohibited Measurement starts. Specify value SQGQ However, protect level parameters still changed. K3MA-F K3MA-F Select maximum input frequency K3MA-F. pulse frequency selection either kHz. example, this because conveyor belt turning slow speed. Parameter: (pulse frequency), Setting value: scaling. relationship between display value input value shown following equation. Rotations (rpm) E2E-X5E1 Proximity Sensor Setting Example Initial Settings settings following example shown here. Example: Display conveyor belt feed speed Frequency input/No. pulses rotation Cycle speed (m/min) Rotations roll circumference pulses rotation Frequency (Hz) Roller diameter MAX/MIN LEVEL MODE SHIFT K3MA-F-A2 100-240VAC Here, conveyor belt feed speed displayed units m/min. Proximity Sensor: E2E-X5E1, output pulse/rotation, roller diameter Display value When input conditions applied this equation, obtain following: Display value input display value 18.8495 (m/min). scaling settings K3MA-F must integers. Also, decrease error, scaling value multiplied 1,000, obtain input 1000 display value 18850. However, because display value this case displayed first decimal place, scaling shown following example that 18850 displayed input 18850 Input value Parameter Setting value (scaling input value) (scaling display value) (decimal point position) Note: decimal point position here refers position number after scaling. When setting scaling display value, necessary consider number digits displayed past decimal point. Application Examples Monitoring rotations mixer churner Inverter Displaying conveyor belt feed speed K3MA-F Displaying monitor output from inverter rotations line speed m/min K3MA-F K3MA-F Gear Proximity sensor Mixer churner Voltage pulse Motor Note: monitor output from inverter analog, such K3MA-J. Monitoring line speed reflow furnace Displaying feed speed food processing, conveying, sintering Mixers resin molding Powdering/pelleting machines, centrifugal separators Monitoring conveyor speed Machining equipment (grinders, polishers) K3MA-F K3MA-F Dimensions 101.2 Finger protective cover (provided) Main indicator character size 14.2 Panel cut-out min. MAX/MIN LEVEL MODE SHIFT Optional Parts (Order Separately) Name Splash-proof Soft Cover Shape K32-49SC Model Hard Cover Installation Insert K3MA-F into panel cut-out hole. waterproof installation, insert rubber gasket onto body K3MA-F. adaptor into grooves left right sides rear case, then push until contacts panel secure K3MA-F. min. 92+0.5 +0.5 44.8 K32-49HC Wiring Precautions crimp terminals. Tighten terminal screws torque approximately avoid influence noise, route signal lines power lines separately. Wiring following crimp terminals. max. max. K3MA-F K3MA-F Unit Markings (Provided) unit markings attached K3MA-F. Select desired markings from provided sheet. Note: scales gauges, unit markings that specified relevant laws regulations. Precautions !Caution touch terminals while power being supplied. Doing result electric shock. Locations subject direct radiant heat from heating equipment. Locations subject exposure water, oil, chemicals. Locations subject direct sunlight. Locations subject dust corrosive gases (particularly sulfuric ammonia gas). Locations subject severe changes temperature. Locations subject icing condensation. Locations subject shock vibration. block heat dissipation around product, i.e., provide sufficient space heat dissipation. Ensure that rated voltage reached within seconds after power turned Conduct aging minutes min. after power turned correct measurement. touch slit sections terminals while power being supplied prevent product from being affected static electricity. heavy objects product during storage. Doing deform deteriorate product. paint thinner cleaning. commercially available alcohol. Mounting Mount product panel that thick. Install product horizontal position. crimp terminals that match screw sizes. Noise Prevention Install product possible from devices that generate strong, high-frequency fields (such high-frequency welders sewing machines) surges. Install surge absorbers noise filters nearby devices that generate noise (particularly motors, transformers, solenoids, magnet coils, other devices that have high inductance component). Line filter Power supply input !Caution disassemble product touch internal components product while power being supplied. Doing result electric shock. !Caution allow pieces metal wire clippings enter product. Doing result electric shock, fire, malfunction. !Caution Perform correct settings product according control application. Failure cause unexpected operation, resulting damage product injury. !Caution Take safety measures, such installing separate monitoring system, ensure safety even product fails. Product failure prevent comparative outputs from being generated, resulting serious accidents. Observe following precautions ensure safety. Maintain power supply voltage within range specified specifications. Maintain load within ratings specified specifications. Check each terminal correct number polarity before connecting Incorrect reverse connections damage burn internal components product. Tighten terminal screws securely. recommended tightening torque 0.43 0.58 Loose screws cause fire malfunction. connect anything unused terminals. Provide switch circuit breaker that operators easily turn power supply when necessary. Also provide appropriate indications such devices. attempt disassemble, repair, modify product. product where flammable combustible gases present. Frequency /Rate Meter Signal input Frequency /Rate Meter Power supply input Surge absorber Application General Precautions product following locations: K3MA-F prevent inductive noise, separate terminal block wiring product from high-voltage high-current power lines. route wiring product parallel with bundle with power lines. When using noise filter power supply, check voltage current install close possible Frequency/Rate Meter. install product near radios, television sets, wireless devices. Doing cause reception interference. Increasing Service Life K3MA-F product locations where temperature humidity exceeds ratings where condensation occur. When installing product panel, sure that temperature around product (not temperature around panel) does exceed ratings. product service life depends ambient temperature. higher ambient temperature, shorter service life. extend product service life, lower temperature inside Frequency/Rate Meter. store product within temperature humidity ranges given specifications. When gang-mounting Frequency/Rate Meters arranging them vertically, heat generated Frequency/Rate Meters will cause internal temperature rise, reducing service life. such cases, consider forced cooling methods, such using circulate around Frequency/Rate Meters. not, however, allow only terminals cooled. Doing will increase measurement error. life output relays greatly affected switching capacity switching conditions. these relays within their rated load electrical life. contacts fuse burn they used past their electrical life. Troubleshooting When error occurs, error details will displayed main indicator. Confirm error from main indicator take appropriate countermeasures. Level display Main indicator Error contents memory error EEPROM memory error Countermeasures Repair necessary. Consult your OMRON sales representative. When this error displayed, press Level seconds, settings will restored factory settings. error cannot recovered, repair necessary. Consult your OMRON sales representative. Promptly change input value that falls within specified range. scaling value inappropriate. Review scaling value initial setting level. Flashes scaling display value lower than -19999. Promptly change input value that falls within specified range. scaling value inappropriate. Review scaling value initial setting level. Flashes scaling display value exceeds 99999. DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. Cat. N107-E1-01 interest product improvement, specifications subject change without notice. OMRON Corporation Industrial Automation Company Measuring Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku Kyoto, 600-8530 Japan Tel: (81)75-344-7108/Fax: (81)75-344-7189 Printed Japan 1001-1M (1001) Other recent searchesW91580 - W91580 W91580 Datasheet U3745BM - U3745BM U3745BM Datasheet U2745B - U2745B U2745B Datasheet SUD50N04-8m8P - SUD50N04-8m8P SUD50N04-8m8P Datasheet PE43204 - PE43204 PE43204 Datasheet 1737000000 - 1737000000 1737000000 Datasheet
Privacy Policy | Disclaimer |