Input LED-Display 50-2000A Ammeters E156931 Scales displays


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



ACA5-20PC Series
Input LED-Display 50-2000A Ammeters
E156931
Scales displays output 50:5A 2000:5A current transformers ranges (0-50 0-2000 Amp) Power options, models Functionally complete: On-board current transformers Scaling/interface circuitry Precision converters Bright green displays Subminiature, 1.38" 0.88" package Easy-to-read, 0.37"/9.4mm digits powered models: 120/220Vac 50/60Hz models "self-powered" +5-40V powered model 2000V isolation; UL/CSA recognized Digital replacements analog ammeters
ACA5-20PC Series Ammeters designed scale digitally display output standard, 5A-output current transformers (50:5A, 500:5A, 1000:5A, etc.). Simply pass secondary/output wires "primary" through ACA5-20PC's on-board apply power meter, you're instantly measuring currents over ranges from 0-50A (with 100mA resolution) 0-2000A (with resolution). Because they accept outputs from previously installed high-current CT's, ACA5-20PC's instantly bring modern digital precision older ammeters. functionally complete ACA5-20PC ammeters incorporate scaling/interface circuitry mate on-board precision digit) converter. A/D's output directly drives meters' large (0.37"/9.4mm digit height), easy-to-read, displays. models employ auto-zero circuits, precision bandgap references, super stable metal-film resistors unsurpassed accuracy (±0.15%FS) stability. ACA5-20PC meters either (120/220Vac 50/60Hz) (+5-40V) powered. models powered same supply whose current they monitoring. ACA5-20PC's provide 2000Vdc isolation between measured current their power supply, models UL/CSA recognized. Each meter housed subminiature, 1.38" 0.88", epoxy-encapsulated package whose behind-the-panel installation depth inches. Display color options include standard red, high-intensity red, standard green. Each meter supplied with plastic bezel assembly with sealing gaskets (DATEL DMS-BZL4-C).
CAL.
DIGIT CONVERTER
PRECISION FULL-WAVE RECTIFIER
DISPLAY
(L1)
POWER CONVERTER
BUILT-IN 0-5A CURRENT TRANSFORMER
OUTPUT FROM 50:5A 2000:5A EXTERNAL CURRENT TRANSFORMER
INPUT POWER
Figure ACA5-20PC Series Simplified Schematic
DIGITAL PANEL METERS
updated, full-size data sheets visit: www.cd4power.com
MPM_ACA520PC_D00 Page
ACA5-20PC Series
Performance/Functional Specifications Typical 25°C, unless otherwise noted. Full-Scale Current Models Overcurrent Rating Performance Sampling Rate Accuracy Measurement Type Temperature Drift +60°C) Zero Reading Dielectric Withstanding Voltage Power Supply Voltage ACA-20PC-X-AC1-RL (47-99Hz) ACA-20PC-X-DC1-RL Power Supply Current ACA-20PC-X-AC1-RL (47-99Hz) ACA-20PC-X-DC1-RL Power Supply Terminal Block Wire Size Type Insulation Strip Length Screw Tightening Torque Display Display Type Size Overrange Indication Decimal Point Physical/Environmental Operating Temperature Storage Temperature Humidity (non-condensing) Case Material Dimensions Weight: (All models) +4.75 Min. Typ. Max.
Units Amps
Ordering Information
rated full-scale current reading second ±0.15%FS Counts Sine wave input, full-wave averaging, calibrated "-001" 2000 ±0.2 "000" ±0.4 "001" Cnts/°C Counts mAdc
ACA5 20PC
Input Range: (45-450Hz) 50.0A 75.0A 100.0A 150.0A 199.9A 250A 300A 400A 500A 600A 750A 1000A 1500A 1999A RoHS Partno. 7020-01036-0 7020-01037-0 7020-01038-0 7020-01039-0 7020-01040-0 7020-01041-0 39-3681407 39-3681408 39-3681409 7020-01042-0 7020-01043-0 7020-01044-0 7020-01045-0 7020-01046-0 RoHS Compliant Color: Standard Power Supply: 85-264Vac@50/60Hz +5-40Vdc
Accessories: DMS-20-CP Panel cutout punch 16-22AWG (solid stranded) 0.25 inches pounds/inches (0.4Nm) digit, 0.37"/9.4mm high Model dependent. Ordering Info.
DMS-BZL4 bezel assembly with sealing gasket supplied with each ammeter. Matching Current Transformers: current transformers ACA5-20PC ammeters available from DATEL nominal cost. technical information, visit www.cd4power.com, select Digital Panel Meters, then Accessories.
TECHNICAL NOTES
IMPORTANT! ensure safe reliable operation, ACA5-20PC ammeters must installed serviced qualified technical personnel. Contact DATEL there doubt regarding ammeter installation and/or operation. Measurement Type: ACA5-20PC ammeters employ full-wave-rectified, average responding, rms-calibrated circuit measure steppeddown output their built-in current transformer (CT) Stated accuracy specifications measured using sine-wave current close full-scale input level, nominal line frequency. Calibration: Periodic recalibration ACA5-20PC ammeters required under normal, indoor operating environments. user calibration necessary, should performed qualified technical personnel. Calibration performed with potentially lethal voltages applied ACA5-20PC associated wiring, with specified full-scale current flowing through ammeter's built-in current transformer. plastic, fullyinsulated adjusting tool must used access recessed calibration potentiometer located back meter (see Mechanical Specifications). Contact DATEL additional information required regarding calibration, setup, other technical issue pertaining ACA5-20PC ammeters. Wire Gauges Fusing: Wires specified Functional Specifications section must used making connections ACA5-20PC Series ammeters. power-supply load wiring must rated supply voltages currents they will conduct must comply with code application-mandated requirements pertaining user's specific installation.
Polycarbonate 1.38"W 0.88"H. Depth model dependent (see mechanical specification) Ounces grams)
specified Full-Scale Current current carried single wire passing through center hole ACA5-20PC's on-board load current ultimately being measured. Overcurrent Rating continuous rating that applies Full-Scale Current. does apply circuitry external meter. Listed accuracy specifications apply over range Rated Full-Scale Current over frequencies 45-450Hz. Maximum reverse polarity protection "DC1" models -40Vdc. specified maximum power supply currents steady-state. AC-powered models draw larger surges initial turn
DIGITAL PANEL METERS
www.cd4power.com
MPM_ACA520PC_D00 Page
ACA5-20PC Series
supply wires connected both meter load must fused according current rating wire gauge being used, accordance with applicable regulatory codes. Also, wire insulation should stripped within +/-10% stated dimensions, wires should inserted into such that their insulation pinched screw terminal. used only powering meter's internal circuitry. must used supply current external loads. AC-powered models draw minimal steady-state supply currents (50mA max.), most applications, they fused according supply wire's maximum amperage rating. However, these models draw significantly higher surge currents brief periods when line voltage initially applied. Supply Polarity Grounding: supply inputs, TB1-A TB1-B, ac-powered ACA5-20PC ammeters themselves polarity sensitive, that they have internal designations. Also, ac-powered ACA5-20PC ammeters include require connection earth/chassis ground. Connector Torque Ratings: important tighten TB1's, screw-terminals their rated torque specification pound-inches (0.4Nm). Proper tightening will minimize connector losses ensure safe, reliable operation. DC-Powered Models: DC-powered models draw minimal supply currents (120mA max.) most applications fused according supply wire's maximum amperage rating. However, sure check comply with applicable codes regulations ensure proper installation operation.
Isolation: on-board (L1) provides minimum 2000Vdc isolation between current-carrying conductor passing through primary circuit ammeter supply voltage connected TB1. This isolation rating only applies applications which load wiring (i.e., wire passing through L1's center hole) does connect directly indirectly TB1-A TB1-B. Precautions: normal operation, current transformer's secondary circuit operates very voltage closedloop operation burden resistance. However, still generate potentially lethal voltages output current suddenly interrupted. example, loose secondary connections cause condition referred "inductive kick". Inductive kick generate extremely high voltages across intermitent secondary connections. Therefore, implementing connections current transformer's output leads must only performed with zero load-current, that with power applied load circuit. Connections Grounding: Some applications require connecting external CT's output leads earth/chassis ground. USA, consult latest revision National Electrical Code (NEC) more information regarding grounding. After mechanical assembly completed, connect output leads external each other after they through L1's center hole. Pressure-style connectors (commonly refered "wire nuts") acceptable long they rated number conductors voltage invloved. Replacing Analog Panel Meters: ACA5-20PC ammeters used direct replacements analog panel meters driven CT's. wiring operations must performed with both load supply power sources completely de-energized.
PANEL INSTALLATION
connections ACA5-20PC Series ammeters must made after ammeter securely attached panel with load supply voltages de-energized (off). Care should exercised when passing conductors through ammeter's built-in installed wire positions should such that minimal forces applied built-in TB1, ammeter itself. high-vibration environments, proper strain reliefs must used load supply wiring. ensure secure panel-mount installation, DATEL recommends using DMS-BZL4-C bezel assembly (with sealing gasket) supplied with each
Step
PANEL
ammeter. Mechanical Specifications detailed cutout ammeter dimensions. Following four-step sequence shown Figure being careful apply excessive force twisting motions insert ammeter into panel opening. When using DMS-BZL4-C, install sealing gasket positioned between ammeter's front flange panel front surface (see Mechanical Specifications). sure securely tighten four screws supplied with bezel assembly.
Step
PANEL
Step
PANEL
Step
BEZEL
PANEL
GASKET (optional)
Figure Panel Installation
DIGITAL PANEL METERS
www.cd4power.com
MPM_ACA520PC_D00 Page
ACA5-20PC Series
TYPICAL WIRING DIAGRAMS
First pass carefully dress output wire from external through on-board (L1). Then connect supply shown. required, verify that correct line-power polarities applied external load (see Technical Note Ensure wires stripped terminals torqued correctly. proper operation, pass only single wire through on-board CT's center hole.
POWER SUPPLY
ACA5-20PC-X-ACX
LOAD
EXTERNAL 5A-OUTPUT CURRENT TRANSFORMER
0-5A OUTPUT
Figure ACA5-20PC AC-Powered Models
First pass carefully dress output wire from external through on-board (L1). Then connect powersupply wires TB1, observing correct positive ("+") negative ("-") polarities. Ensure wires stripped terminals torqued correctly. proper operation, pass only single wire through on-board CT's center hole.
ACA5-20PC-X-DCX
POWER SUPPLY
LOAD
EXTERNAL 5A-OUTPUT CURRENT TRANSFORMER
0-5A OUTPUT
Figure ACA5-20PC DC-Powered Models
DIGITAL PANEL METERS
www.cd4power.com
MPM_ACA520PC_D00 Page
ACA5-20PC Series
MECHANICAL SPECIFICATIONS
Tolerances inches (mm): ±0.02 (±0.51), ±0.010 (±0.254)
Hole Diameter: 0.27 (6.9) min.
BEZEL INSTALLATION
2.01 (51.1)
0.040 (1.02)
1.00 (25.4)
0.040 (1.02)
1.30 (33.0) 1.38 (35.1)
0.040 (1.02)
0.80 (20.3) 0.88 (22.4)
1.32 (33.5)
PANEL
FRONT VIEW
BACK VIEW
CAL.
BEZEL
GASKET (optional)
BEZEL INSTALLATION RECOMMENDED DRILL PANEL CUTOUT
DMS-BZL4-C BEZEL DMS-BZL4 BEZEL
#2-56 INSERT 0.156 (3.96) DEEP FRONT VIEW 0.187 (4.75)
RECOMMENDED DRILL PANEL CUTOUT DIMENSIONS
0.093 (2.362) DIAMETER REQUIRED) ONLY WHEN USING SUPPLIED BEZEL ASSEMBLY INTERNAL CORNER RADII: 0.032 (0.81) MAX. 0.116 (2.95)
1.280 (32.51)
1.07 (27.18)
0.838 (21.29)
1.336 (33.93)
0.145 (3.68)
1.826 (46.38)
1.626 (41.30)
DIGITAL PANEL METERS
www.cd4power.com
MPM_ACA520PC_D00 Page
ACA5-20PC Series
updated, full-size data sheets visit: www.cd4power.com
USA: Tucson (Az), Tel: (800) 2537, email: sales@cdtechno.com Canada: Toronto, Tel: (866) 1232, email: toronto@cdtechno.com United Kingdom: Milton Keynes, Tel: (0)1908 615232, email: mk@cdtechno.com France: Montigny Bretonneux, Tel: (0)1 email: france@cdtechno.com
Technologies, Inc. Cabot Boulevard, Mansfield, 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.cd4power.com
9001 REGISTERED
Germany: Tel: (0)89-544334-0, email: ped.munich@cdtechno.com Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@cdtechno.com Osaka, Tel: 6-6354-2025, email: sales_osaka@cdtechno.com Website: www.cd4power.jp China: Shanghai, Tel: 3678, email: shanghai@cdtechno.com Guangzhou, Tel: 8066, email: guangzhou@cdtechno.com
email: sales@cdtechno.com
DS-0446D 01/2007
2006 Technologies, Inc. Technologies, Inc. makes representation that products circuits described herein, other technical information contained herein, will infringe upon existing future patent rights. descriptions contained herein imply granting licenses make, use, sell equipment constructed accordance therewith. Specifications subject change without notice. DATEL logo registered Technologies, Inc. trademark.
DIGITAL PANEL METERS
MPM_ACA520PC_D00 Page
updated, full-size data sheets visit: www.cd4power.com

Other recent searches


TM9937 - TM9937   TM9937 Datasheet
TCD-9-1W+ - TCD-9-1W+   TCD-9-1W+ Datasheet
STP03D200 - STP03D200   STP03D200 Datasheet
SNC21300A - SNC21300A   SNC21300A Datasheet
IDT54 - IDT54   IDT54 Datasheet
74FCT245T - 74FCT245T   74FCT245T Datasheet
AD9122 - AD9122   AD9122 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive