| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
True-RMS-AC Ammeters with Built-in Current Transformers Built-in
Top Searches for this datasheetACA-20RM Series True-RMS-AC Ammeters with Built-in Current Transformers Built-in provide true-rms values complex waveforms Perfect measuring current applications Five ranges measure:0-0.2A, 0-2A, 0-20A, 0-30A 0-50A models features split-core easy installation Self-powered from 85-140Vac 170-264Vac Large, easy-to-read, display with 0.37" digits Reliable single-board construction Digital replacement analog meters recognized components DATEL's ACA-20RM Series world's first digital ac-ammeters incorporate built-in current transformer (CT) directly measure true-rms value complex, non-sinusoidal currents from bulky expensive "donut" required! Operation setup straightforward: simply pass load-carrying wire through on-board apply power, ammeter fully operational. Five input ranges measure 0-0.2 amps (0.1mA resolution), amps (0.001A resolution), 0-20 amps (0.01A resolution), 0-30 amps (0.1A resolution) 0-50 amps (0.1A resolution). model features oversized split-core current transformer that easily accommodates wires sizes (21.2mm2). power supply options available: 85-140V (47-63Hz), 170-264V (47-63Hz). models totally self-contained; external components required. Power consumption from nominal 120V 220V supply less than 50mA. And, precision autozeroing circuitry, super-stable components, rms-to-dc converter circuit combine achieve excellent performance when measuring complex, non-sinusoidal, currents found today's computer/telecom equipment. ACA-20RM Series ammeters feature full-size, 0.37" (9.4mm) high, digit, bright LED-displays built-in bezel/filter assembly that features metal fasteners. They panel-cutout compatible with DATEL's DMS-20 Series voltage frequency monitors, making ACA-20RM ammeters perfect replacements older, less reliable, analog panel meters today's sophisticated instrumentation. CAL. DIGIT CONVERTER RMS-to-DC CONVERTER DISPLAY (L1) POWER CONVERTER BUILT-IN CURRENT TRANSFORMER MEASURED LOAD CURRENT INPUT POWER Figure ACA-20RM Series Simplified Schematic DIGITAL PANEL METERS updated, full-size data sheets visit: www.cd4power.com MPM_ACA-20RM_A00 Page ACA-20RM Series Performance/Functional Specifications Typical +25°C, unless otherwise noted. Rated Full-Scale Current ACA-20RM-0-ACX-RL ACA-20RM-1-ACX-RL ACA-20RM-2-ACX-RL ACA-20RM-4-ACX-RL ACA-20RM-5-ACX-RL Overcurrent Rating Performance Sampling Rate Accuracy Measurement Type Temperature Drift 60°C) Zero-Current Reading (within sec.) Dielectric Withstanding Voltage Power Supply Voltage ACA-20RM-X-AC3-RL ACA-20RM-X-AC4-RL Power Supply Current ACA-20RM-X-AC3-XX ACA-20RM-X-AC4-XX Power Supply Terminal Block Wire Size Insulation Strip Length Screw Tightening Torque Rated Voltage Display Display Type Size Overrange Indication Decimal Point Physical/Environmental Operating Temperature Storage Temperature Humidity (non-condensing) Dimensions Weight: ACA-20RM-0,1,2-XXX-XX ACA-20RM-4-XXX-XX ACA-20RM-5-XXX-XX Digit LED, 0.37"/9.4mm high "1_" 16-22AWG, Solid stranded 0.250 inches pound-inches (0.4Nm) 310Vac -001 2000 samples second ±0.4%FS counts with 60Hz sine wave input responding, Crest Factors ±0.2 ±0.4 1.999 19.99 50.0 30.0 UNIT 199.9 mAmperes Amperes Amperes Amperes Amperes Ordering Information ACA-20RM- RoHS Color: Low-Power Power: 85-140Vac@50/60Hz 170-264Vac@50/60Hz Rated full-scale current Counts Input Range: 199.9mA 1.999A 19.99A 50.0A (with split-core flying-lead 30.0A (with flying-lead Accessories: DMS-20-CP Panel Cutout Punch Vac/47-63Hz Vac/47-63Hz mA/47-63Hz mA/47-63Hz TECHNICAL NOTES IMPORTANT! ensure safe reliable operation, ACA-20RM ammeters must installed serviced qualified technical personnel after reading this data sheet it's entirety. Contact DATEL there doubt regarding their installation operation. Measurement Type: ACA-20RM ammeters employ true-rms input circuitry measure stepped-down output their on-board current transformers (CT). Stated accuracy measured using sine-wave input close specified full scale input, nominal line frequency 60HZ. Calibration: Periodic recalibration ACA-20RM ammeters required under normal indoor environments. user calibration deemed necessary, must performed qualified technical personnel since potentially lethal voltages currents applied ACA-20RM during calibration process. Calibration performed with approximately specified full-scale current flowing through ammeter's built-in fully insulated, non-metallic adjusting tool must used adjust calibration potentiometer, located back ammeter (see Mechanical Specifications section). calibration potentiometer approximately turn rotation; force adjustment screw past stops. Contact DATEL additional information required regarding calibration, setup, other technical issue pertaining ACA-20RM ammeters. Wire Gauges Fusing: only wires specified under Functional Specifications Section when making connections ACA20RM Series ammeters. power supply load wiring must Fixed, model dependent (see full-scale input current) model dependent, sheets Ounces grams) nominal Ounces grams) nominal Ounces grams) nominal Footnotes Specified full-scale currents those passing through ammeter's built-in current transformer's primary load-circuit. Notes below additional model-specific information. overcurrent rating rated full-scale current continuous rating applies current passing through built current transformer only, does apply external circuit-wiring external loads. Accuracy guaranteed rated current level. Specified accuracy applies inputs with crest factors (CF) 2.0, where Vpeak/Vrms. Crest factors introduce additional error full scale. Ammeters calibrated with near full-scale 60Hz sine-wave current flowing through ammeter's built-in specified maximum power supply currents steady state; larger surge currents occur initial application line power. DIGITAL PANEL METERS www.cd4power.com MPM_ACA-20RM_A00 Page ACA-20RM Series adequately rated supply voltages currents they will carry, they must comply with code- application-mandated requirements pertaining user's installation. supply wires connected ACA-20RM ammeters must fused accordance with applicable regulatory codes. Also, wire insulation should stripped within +/-10% stated dimensions; wires should inserted into such that screw terminal does pinch their insulation. only used supplying power meter's internal circuitry; must used supply current external loads. AC-powered models draw minimal steady-state supply currents (less than 0.050A) they fused according supply wire's maximum amperage rating. However, these models draw higher surge currents brief periods microsecond range) when power initially applied. Supply Polarity Grounding: supply inputs, `B', ACA-20RM ammeters polarity sensitive, that they have designations. Also, ac-powered ACA-20RM ammeters include require connection earth/chassis ground. Connector Torque Ratings: sure tighten TB1's screw-terminals pound-inches (0.4Nm). Proper tightening will ensure reliable long-term operation. Isolation: on-board (L1) provides minimum 2000Vdc isolation between current-carrying load conductor passing through opening ammeter's power source that's connected TB1. course, this isolation rating applies only applications where load wire does connect directly indirectly TB1-A TB1-B (i.e., where different supplies involved). Split-Core (Clamp-on) Models: models feature split-core current transformer that clamped around current-carrying load conductor without having disconnect remove power from load's power source. This live-connection capability only used load's power source isolated (see technical note from ammeter's power source that's connected TB1. ammeter's power supply must always denergized before making connections TB1. Refer `Panel Installation' section this data sheet additional information. WIRING DIAGRAMS First pass carefully dress external load wire through then connect supply load wires shown. Ensure wires stripped properly tightened. accurate operation, make only pass with load wire through on-board (only primary turn). splitcore models, make sure fully engage CT's Locking mechanism BACK VIEW BACK VIEW FUSED POWER FUSED POWER LOAD LOAD FROM SUPPLY Figure Connections pc-board mounted CT's FROM SUPPLY Figure Connection flying lead CT's DIGITAL PANEL METERS www.cd4power.com MPM_ACA-20RM_A00 Page ACA-20RM Series PANEL INSTALLATIONS connections ACA-20RM Series ammeters must made after ammeter securely attached panel with associated load supply voltages de-energized (off). However, using extreme caution observing safety measures applicable user's installation, split-core models connected energized current-carrying load conductors, connections must always made with ammeter's power source off. Care should exercised when passing load-carrying conductor through meter's built-in CT-particularly when larger conductors used. installed wire-positions should such that minimal mechanical forces applied built-in TB1, ammeter itself. highvibration environments, strongly recommended that adequate strain reliefs used load supply wiring. Using Figure guide, carefully insert bezel/color filter assembly into panel opening. From rear panel, install four round plastic standoffs over bezel's threaded studs. Install pc-board assembly then attach securely tighten four nuts. only factory-supplied hardware substitute hardware could result unsafe installation and/or adversely affect reliability ammeter itself. recommended range panel thickness that used with supplied hardware 0.040 inches (1.0mm) 0.125 inches (3.2mm). Panel thickness outside this range will require additional user-supplied hardware and/or modifications. PANEL Figure Panel Installation BEZEL PANEL CUTOUT 0.187 (4.75) FRONT VIEW RECOMMENDED DRILL PANEL CUTOUT DIMENSIONS 0.55 (13.97) INTERNAL CORNER RADII: 0.032 (0.81) MAX. 0.116 (2.95) 1.280 (32.51) 1.07 (27.18) 0.838 (21.29) 1.336 (33.93) 0.145 (3.68) 1.826 (46.38) 1.626 (41.30) 0.093 (2.362) DIAMETER REQUIRED) DIGITAL PANEL METERS www.cd4power.com MPM_ACA-20RM_A00 Page ACA-20RM Series MECHANICAL SPECIFICATIONS MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES: ±0.02 (±0.51) ±0.010 (±0.254) 0.984 2.100 (53.34) 2.100 (53.34) 2.100 (53.34) 1.575 1.400 (35.56) 1.400 (35.56) 1.750 (44.45) Lead Length (127.0) min. 1.024 Lead Length (50.5) min. 0.551 0.35 (8.9) Diameter 1.575 (40.00) 0.40 (10.2) Diameter 0.984 (24.99) 0.26 (6.6) Diameter 0.250 (6.35) 1.024 (26.01) 0.250 (6.35) 0.480 (12.19) 1.00 (2.54) Models 0.250 (6.35) 0.480 (12.19) 0.551 (14.00) DIGITAL PANEL METERS www.cd4power.com MPM_ACA-20RM_A00 Page ACA-20RM Series updated, full-size data sheets visit: www.cd4power.com USA: Tucson (Az), Tel: (800) 2537, email: sales@cdtechno.com Canada: Toronto, Tel: (866) 1232, email: toronto@cdtechno.com United Kingdom: Milton Keynes, Tel: (0)1908 615232, email: mk@cdtechno.com France: Montigny Bretonneux, Tel: (0)1 email: france@cdtechno.com Technologies, Inc. Cabot Boulevard, Mansfield, 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.cd4power.com 9001 REGISTERED Germany: Tel: (0)89-544334-0, email: ped.munich@cdtechno.com Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@cdtechno.com Osaka, Tel: 6-6354-2025, email: sales_osaka@cdtechno.com Website: www.cd4power.jp DS-0561A 02/07 email: sales@cdtechno.com 2006 Technologies, Inc. Technologies, Inc. makes representation that products circuits described herein, other technical information contained herein, will infringe upon existing future patent rights. descriptions contained herein imply granting licenses make, use, sell equipment constructed accordance therewith. Specifications subject change without notice. DATEL logo registered Technologies, Inc. trademark. China: Shanghai, Tel: 3678, email: shanghai@cdtechno.com Guangzhou, Tel: 8066, email: guangzhou@cdtechno.com DIGITAL PANEL METERS MPM_ACA-20RM_A00 Page updated, full-size data sheets visit: www.cd4power.com Other recent searchesTH7887A - TH7887A TH7887A Datasheet MAX1003 - MAX1003 MAX1003 Datasheet LC573202A - LC573202A LC573202A Datasheet FW250R1 - FW250R1 FW250R1 Datasheet FW300R1 - FW300R1 FW300R1 Datasheet CMS18 - CMS18 CMS18 Datasheet BLF6G22-45 - BLF6G22-45 BLF6G22-45 Datasheet BAT54WPbF - BAT54WPbF BAT54WPbF Datasheet ADM3070E - ADM3070E ADM3070E Datasheet ADM3071E - ADM3071E ADM3071E Datasheet ADM3072E - ADM3072E ADM3072E Datasheet ADM3073E - ADM3073E ADM3073E Datasheet ADM3074E - ADM3074E ADM3074E Datasheet ADM3075E - ADM3075E ADM3075E Datasheet ADM3076E - ADM3076E ADM3076E Datasheet ADM3077E - ADM3077E ADM3077E Datasheet ADM3078E - ADM3078E ADM3078E Datasheet ADM3071E - ADM3071E ADM3071E Datasheet ADM3074E - ADM3074E ADM3074E Datasheet ADM3077E - ADM3077E ADM3077E Datasheet
Privacy Policy | Disclaimer |