| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
SIngle triple output Rev.02.16.07 NFS40 Series Total Power:
Top Searches for this datasheetNFS40 Series SIngle triple output Rev.02.16.07 NFS40 Series Total Power: Input Voltage: 264VAC 370VDC Outputs: Single, triple Special Features inch package applications) Industry standard package Overvoltage short circuit protection with free convection EN55022, EN55011 conducted noise level safety approvals Available RoHS compliant year warranty Safety VDE0805/EN60950/ IEC950/IEC1010 File 10401-3336-0044 Licence 2559 UL1950 File E136005 C22.2 File LR41062C NFS40 series universal input ac-dc power supply card with maximum component height 1.2" applications. NFS40 series available with wide range models industry standard footprint proven itself highly reliable versatile product wide range communication industrial applications. NFS40 provides output power with free convection cooling which boosted with air. Standard features include short-circuit protection. series, with full international safety approval mark, meets conducted noise EN55022 level NFS40 series designed power data networking, computer, telecom industrial applications such hubs, routers, terminals, cable modems, PABX's, industrial PC's machine control. Specifications specifications typical nominal input, full load 25°C unless otherwise stated Rev.02.16.07 NFS40 Series OUTPUT SPECIFICATIONS Output voltage adjustability Line regulation Load regulation Transient response Temperature coefficient Overvoltage protection Output power limit Short circuit protection output triples Vout singles Main output Auxiliary outputs Main output Auxiliary outputs (1.5-3 outputs output Primary power limited Single outputs Multiple outputs ±5.0% ±5.0% ±0.2% ±1.0% ±2.0% ±5.0% ±120 max. dev. recovery ±0.02%/°C 125% ±15% Vout input power limit Continuous Short term GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Switching frequency Approvals standards (See Note Weight MTBF (See Note MIL-HDBK-217E Input/output Input/chassis Vac, Watts Vac, Watts typical 3000 1500 Variable VDE0805, EN60950 IEC950, IEC1010, UL1950 C22.2 (9.88 170,000 hours ENVIRONMENTAL SPECIFICATIONS Thermal performance (See Notes Operating Non-operating ambient temp., Convection cooled Forced cooling ambient Peak seconds) Relative humidity Altitude Vibration (See Note Non-condensing Operating Non-operating Derate linearly load 10,000 feet max. 40,000 feet max. peak INPUT SPECIFICATIONS Input voltage range Input frequency range Max. input surge current Safety ground leakage current CHARACTERISTICS Conducted emissions Radiated emissions contact Surge Fast transients Radiated immunity Conducted immunity EN55022, part EN55022 EN61000-4-2, level EN61000-4-2, level EN61000-4-5, level EN61000-4-4, level EN61000-4-3, level EN61000-4-6, level Level Level Perf. criteria Perf. criteria Perf. criteria Perf. criteria Perf. criteria Perf. criteria Vac, cold start Vac, cold start Vac, Vac, Universal input 85-264 120-370 47-440Hz max. max. 0.13 max. 0.32 max. Specifications Contd. OUTPUT VOLTAGE +5.1 +12.0 -12.0 +5.1 +12.0 -12.0 +5.1 +12.0 -5.0 +5.1 +15.0 -15.0 +5.1 +12.0 +15.0 +24.0 Notes Natural convection cooled, maximum. Peak output current lasting less than seconds with duty cycle less than 10%. During peak loading, outputs outside total regulation limits. Peak total power must exceed Forced air, atmosphere, maximum. Figure peak-to-peak. Output noise measured across bandwidth using inch twisted pair, terminated with capacitor. Total regulation defined static output regulation 25°C, including initial tolerance, line voltage within stated limits, load currents within stated limits, output voltages adjusted their factory settings. Also, 0.25<I(A)/I(B)<5.0 maintain stated regulation. This does apply NFS40-7628 power supply regulated auxiliary outputs. minimum load required output obtain full current from negative output. NFS40 offers possibility power sharing between outputs. Consult factory details. Derating curve application specific ambient temperatures >50°C, optimum reliability part heatsink should exceed semiconductor case temperature should exceed minimum load recommended achieve design MTBF. Caution: Allow minimum second after disconnecting power when making thermal measurements. Three orthogonal axes, sweep octave/minute, minute dwell four major resonances. NFS40-7628 separately linear regulated outputs. loading conditions Notes apply. This product only inclusion professional installers within other equipment must operated stand alone product. suffix indicates that these parts Pb-free (RoHS 6/6) compliant. RoHS (non Pb-free) compliant versions available special request, please contact your local sales representative details. NOTICE: Some models support options. Please contact your local Artesyn representative on-line model number search tool find suitable alternative. Rev.02.16.07 NFS40 Series OUTPUT CURRENTS 0.35 0.35 0.35 0.35 0.35 PEAK RIPPLE TOTAL REGULATION ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±5.0% ±2.0% +10%/-3.0% ±5.0% ±2.0% ±2.0% ±2.0% ±2.0% MODEL NUMBER (14,15,D) NFS40-7608J (5,6) NFS40-7628J (12) NFS40-7607J (5,6) NFS40-7610J (5,6) NFS40-7605J NFS40-7612J NFS40-7615J NFS40-7624J P1(C) CONNECTIONS -7608J, -7628J -7607J -7610J Live Live Live Neutral Neutral Neutral +5.1 +5.1 Return Return +5.1 +5.1 Return Return +5.1 +5.1 Return Return SINGLES Line Neutral +Vout +Vout +Vout Return Return Return Safety Ground DERATING CURVE (See Notes Output Power (Watts) FORCED COOLING NATURAL CONVECTION COOLING MIN. LOAD REQUIRED ACHIEVE DESIGN MTBF 10°C 20°C 30°C 40°C 50°C 60°C 70°C Rev.02.16.07 NFS40 Series Mechanical Notes order meet safety requirements, non-metallic stand-off mandatory hole specified mechanical drawing above. ground mounting hole near allows system grounding through metal stand-off. improve conducted noise, ground mounting hole near output connector should connected with ground mounting hole near metal stand-offs attached common metal chassis. This connection also significantly attenuates common mode noise. standard L-bracket cover available mounting which contains screws, connectors necessary mounting hardware. Order part number `NFS40 COVER KIT'. Americas 5810 Allen Carlsbad, 92008 Telephone: 4600 Facsimile: 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, United Kingdom Telephone: 1384 Facsimile: 1384 MAXIMUM COMPONENT HEIGHT inches 0.156 (3.96) Dia. Places) 5.00 (127.00) Asia (HK) 16th 17th Floors, Plaza Wing Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 NON-METALLIC STAND-OFF (SEE NOTE 3.00 (76.2) 3.15A, 250VAC (SEE NOTE 2.550 (64.8) global contact, visit: www.powerconversion.com While every precaution been taken ensure accuracy completeness this literature, Emerson Network Power assumes responsibility, disclaims liability damages resulting from this information errors omissions. 0.22 (5.59) 4.55 (115.8) 0.22 (5.59) DIMENSIONS INCHES (mm) Emerson Network Power. global leader enabling business-critical continuity. Power Connectivity Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring Services EmersonNetworkPower. Emerson Network Power Emerson Network Power logo trademarks service marks Emerson Electric ©2007 Emerson Electric Other recent searchesy96E - y96E y96E Datasheet TXC-21007 - TXC-21007 TXC-21007 Datasheet TXC-21107 - TXC-21107 TXC-21107 Datasheet STM-1 - STM-1 STM-1 Datasheet STS-3 - STS-3 STS-3 Datasheet STS-3c - STS-3c STS-3c Datasheet STS-1 - STS-1 STS-1 Datasheet SN74BCT244 - SN74BCT244 SN74BCT244 Datasheet SN54BCT244 - SN54BCT244 SN54BCT244 Datasheet SMPX140 - SMPX140 SMPX140 Datasheet RH27C - RH27C RH27C Datasheet LMH6611 - LMH6611 LMH6611 Datasheet LMH6612 - LMH6612 LMH6612 Datasheet 2SA985 - 2SA985 2SA985 Datasheet 2SA985A - 2SA985A 2SA985A Datasheet
Privacy Policy | Disclaimer |