| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
3G3JV miniature high-efficiency frequency inverter with excellent pric
Top Searches for this datasheet3G3JV inverter 3G3JV miniature high-efficiency frequency inverter with excellent price- performance relationship. generous dimensions power section ensure high starting torque susceptibility overload which increases machine reliability. many programmable inputs outputs, integrated potentiometer speed control various monitor functions provide inverter with high versatility flexibility. multifuntion inputs either NPN. analog inputs 0.10 4.20 0.20 Features exceptionally compact design integrated reference value potentiometer modbus interface, optional fixed frequencies multifunction digital inputs multifunction digital output multifunction analog output Approval: System architecture comply with relevant guidelines imperative frequency inverters operated with line filters. Voltage supply Shielding Contact surfaces metal plate Cabinet assembly metal plate Line filter, footprint type Shielding 3G3JV inverter Product overview Max. motor output Output current Rated voltage Product number Standard type Single phase 0,25 0,55 Three phase 3G3JV-AB001 3G3JV-AB002 3G3JV-AB004 3G3JV-AB007 3G3JV-AB015 3G3JV-A2001 3G3JV-A2002 3G3JV-A2004 3G3JV-A2007 3G3JV-A2015 3G3JV-A2022 3G3JV-A2040 3G3JV-A4002 3G3JV-A4004 3G3JV-A4007 3G3JV-A4015 3G3JV-A4022 3G3JV-A4030 3G3JV-A4040 0,25 0,55 Three phase 0,37 0,55 Accessories Line filter, braking resistors, ferrite rings, track mounting bracket Inverter 3G3JV-AB001 3G3JV-AB002 3G3JV-AB004 3G3JV-AB007 3G3JV-AB015 3G3JV-A2001 3G3JV-A2002 3G3JV-A2004 3G3JV-A2007 3G3JV-A2015 3G3JV-A2022 3G3JV-A2040 3G3JV-A4002 3G3JV-A4004 3G3JV-A4007 3G3JV-A4015 3G3JV-A4022 3G3JV-A4030 3G3JV-A4040 Product number Line filter (footprint filter) 3G3JV-PFI1010-E 3G3JV-PFI1010-E 3G3JV-PFI1010-E 3G3JV-PFI1020-E 3G3JV-PFI1020-E 3G3JV-PFI2010-E 3G3JV-PFI2010-E 3G3JV-PFI2010-E 3G3JV-PFI2010-E 3G3JV-PFI2020-E 3G3JV-PFI2020-E 3G3JV-PFI2030-E 3G3JV-PFI3005-E 3G3JV-PFI3005-E 3G3JV-PFI3010-E 3G3JV-PFI3010-E 3G3JV-PFI3010-E 3G3JV-PFI3020-E 3G3JV-PFI3020-E Ferrite rings 3G3IV-PFO OC/1 3G3IV-PFO OC/1 3G3IV-PFO OC/1 3G3IV-PFO OC/1 3G3IV-PFO OC/2 3G3IV-PFO OC/1 3G3IV-PFO OC/1 3G3IV-PFO OC/1 3G3IV-PFO OC/1 3G3IV-PFO OC/2 3G3IV-PFO OC/2 3G3IV-PFO OC/2 3G3IV-PFO OC/1 3G3IV-PFO OC/1 3G3IV-PFO OC/1 3G3IV-PFO OC/2 3G3IV-PFO OC/2 3G3IV-PFO OC/2 3G3IV-PFO OC/2 track mounting bracket 3G3IV-PZZ08122A 3G3IV-PZZ08122A 3G3IV-PZZ08122A 3G3IV-PZZ08122B 3G3IV-PZZ08122B 3G3IV-PZZ08122A 3G3IV-PZZ08122A 3G3IV-PZZ08122A 3G3IV-PZZ08122A 3G3IV-PZZ08122B 3G3IV-PZZ08122B 3G3IV-PZZ08122C 3G3IV-PZZ08122B 3G3IV-PZZ08122B 3G3IV-PZZ08122B 3G3IV-PZZ08122B 3G3IV-PZZ08122B 3G3IV-PZZ08122C 3G3IV-PZZ08122C 3G3JV inverter Technical data class Single phase: 3G3JV-AB Three phase: 3G3JV-A2 Maximum allowed motor output Output data Inverter output Output rated current Max. output voltage Output frequencies Supply Rated input voltage frequency Max. voltage variation Max. frequency variation AB001 A2001 0,12 200.240 50/60 AB002 A2002 0,25 AB004 A2004 0,55 (0,4*) AB007 A2007 (0,75*) AB015 A2015 (1,1*) A2022 11,0 A2040 17,5 proportional input voltage: 0.240 With single phase connection JV-A2 type class Three phase: 3G3JV-A4 Maximum allowed motor output Output data Inverter output Output rated current Max. output voltage Output frequencies Supply Rated input voltage frequency Max. voltage variation Max. frequency variation A4002 0,37 3-phase, 380.460 50/60 A4004 0,55 A4007 A4015 A4022 A4030 A4040 proportional input voltage: 0.460 With single phase connection JV-A2 type 3G3JV inverter Technical data (continued) General data Control functions Control method Output frequency range Frequency precision Resolution frequency reference value Resolution output frequency Overload capacity Frequency reference value Braking torque (short-time peaks) Sinusoidal PWM, terminal Volts/Hertz control 0,1.400 digital reference value: ±0,01 (-10.+50° analogue reference value: ±0,5% ±10° digital reference value: 0,01 (<100 Hz), (>100 analogue reference value 1/1000 maximum frequency 0,01 150%/60 0.10 4-20 (250 0-20 (250 550W, >1,5 Protective functions Motor overload protection Instantaneous overcurrent protection Overload protection Overvoltage protection Undervoltage protection Momentary power interruption compensation (selection) Cooling overheating Ventilator control Grounding protection Functions Digital inputs Digital outputs Analog output Braking acceleration times Display Ambient conditions Type protection Cooling Ambient temperature humidity Storage temperature Assembly Position height Ambient conditions Vibration resistance 150% 100% Sustained braking torque approx. without, 150% with external braking resistor electronically adjustable motor protection stops approx. 250% rated output current stops 150% rated current min. stops when maincircuit voltage approx. stops when maincircuit voltage approx. stops more setting inverter momentary power interruption mode, operation continued power restored within approx. sec. detects electronic protection against blocking protection rated output current level multifunction digital input multifunction digital output multifunction analog output (0.10 0,0.999 frequency, current reference value selection error status IP20, wall installation separate cooler 0,75 (200 open installation: wall installation: -20° +60° cabinet, free dust corrosive gases max. 1000 -10° -10° (without condensation) 3G3JV inverter Connections diagram remains free with single-phase equipment Voltage supply 200.240 VAC, 50/60 single-phase Line filter L1(R) L2/N Forwards-Start-Stop Multifunction input Multifunction input Multifunction input Multifunction input Reference potential Multifunction inputs Multifunction analog output 0.10 Multifunction relay output Closer Opener Common contact (+12 VDC) Frequency reference value 0.10 4.20 3G3JV inverter Dimensions (mm) 3G3JV Product number Product number Line filter 3G3JV-PFI_ Product number 1010E 1020E 2010E 2020E 2030E 3005E 3010E 3020E 3G3JV inverter Parameters Parameter number n001 Default setting MODBUS address 101H Name Adjustment range Parameter write prohibit selection/ parameter initialization Only adjusted n01-079 altered reset error memory used initializes parameters default values 2-wire sequence initializes parameters default values 3-wire sequence Operator console Multifunction inputs modbus (option card needed) integrated potentiometer parameter n021 0.10 4.20 0.20 modbus (option card needed) Stop ramp (n017) Coast stop Reverse enabled Reverse disabled Stop button n02= enabled Stop button n02= disabled integrated potentiometer digital operator (n024) complete input with ENTER ENTER necessary n002 102H Operation mode selection n003 103H Frequency reference selection n004 n005 n006 n007 n008 n009 n010 n011 n012 n013 n014 n015 n016 60.0 60.0 10.0s 104H 105H 106H 107H 108H 109H 10AH 10BH 10CH 10DH 10EH 10FH 110H Stop method Backwards direction rotation Operator stop button Reference value local mode Reference value input local mode Maximum output frequency Max. output voltage Corner frequency Middle output frequency Output voltage middle output frequency Minimum output frequency Output voltage minimum output frequency Acceleration time 50,0.400 1.255 0,2.400 0,1.399,9 0,1.255 0,1.10 0.1.50 0,0.999 3G3JV inverter parameters (continued) Parameter number n017 n018 n019 n020 Default setting 10.0s 10.0s 10.0s MODBUS address 111H 112H 113H 114H Name Adjustment range Braking time Acceleration time Braking time curve slide braking/ accelerating 0,0.999 0,0.999 0,0.999 curve n021 n022 n023 n024 n025 n026 n027 n028 n029 n030 n031 n032 n033 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 6.00 100% depending model 115H 116H 117H 118H 119H 11AH 11BH 11CH 11DH 11EH 11FH 120H 121H Frequency reference value Frequency reference value Frequency reference value Frequency reference value Frequency reference value Frequency reference value Frequency reference value Frequency reference value frequency Max. reference value limit Min. reference value limit Motor rated current simulation motor protection switch Simulation motor protection switch Thermal motor time constant Function ventilator inverter) Multifunction input 0,0.400 0,0.400 0,0.400 0,0.400 0,0.400 0,0.400 0,0.400 0,0.400 0,0.400 0.110 0.110 0.120% relation inverter rated current Standard motor with standard rated data Standard motor short-time operation thermal protection only runs during after STOP) always runs reverse/stop (2-wire) external error (NO) external error (NC) Error reset Multi-step speed reference Multi-step speed reference Multi-step speed reference Jogging Acc./dec. time change over external base block (NO) external base block (NC) Speed search max. frequency Speed search assigned frequency Acc./dec. prohibit Local/Remote change-over Serial change-over/operator Fast stop error (NO) Fast stop alarm (NO) Fast stop error (NC) Fast stop alarm (NC) Change rotation direction (3-wire) otherwise n036 n034 n035 n036 8min 122H 123H 124H 60min n037 n038 n039 125H 126H 127H Multifunction input Multifunction input Multifunction input n036 down comment Self-test otherwise n036 3G3JV inverter Parameters (continued) Parameter number n040 Default setting MODBUS address 128H Name Adjustment range Multifunction output (relay) Fault Inverter operation Reference value reached Zero frequency reached Output frequency n058 Output frequency Over-torque (NO) Over-torque (NC) Alarm Base block mode Ready operation active during error reset under-voltage recognised Reverse direction Speed search Data transfer ModBus n041 n042 n043 n044 n045 n046 100% 0.1s 129H 12AH 12BH 12CH 12DH 12EH Reinforcement analog input Offset analog input Filter time analog input Analog input holding Analog input reinforcement Clock frequency 0.255% -99.99% 0.00.2.00s Output frequency Motor current motor frequency motor frequency motor frequency Error signal Error signal after >0.5 Operation continued 0,00.2,00 n047 12FH Operation after short voltage breakdown start attempts after error Gating frequency Gating frequency Bandwidth gating frequencies Current d.c. braking d.c. braking time Stop d.c. braking time Start Protection against sweep braking Level protection against sweep accelerating Level protection against sweep during operation Frequency recognition level Over-torque recognition n048 n049 n050 n051 n052 n053 n054 n055 n056 n057 n058 n059 0.5s 0.5s 170% 160% 130H 131H 132H 133H 134H 135H 136H 137H 138H 139H 13AH 13BH 0.10 0,0.400 0,0.400 0,0.25,5 0.100 inverter rated current 0,0.25,5 0,0.25,5 Enabled Disabled (braking resistor!!) 30.200% rated current 30.200% rated current 0,0.400 Disabled Detection only when speed coincides operation continues Detection only when speed coincides output shut Always detection, issues alarm Always detection, output shut 3G3JV inverter Parameters (continued) Parameter number n060 n061 n062 n063 n064 n065 n066 n067 n068 n069 Default setting 160% 0.1s depending model depending model 2.0s MODBUS address 13CH 13DH 13EH 13FH 140H 141H 142H 143H 144H 145H Name Adjustment range Level torque recognition Time torque recognition Storing reference value during motor poti operation Torque boost Rated slip no-load current Slip compensation reinforcement Delay time slip compensation Slip compensation braking Setting unit transmission frequence reference frequency monitor Slave address Baud rate 30.200% 0,1.10 stored after STOP Stored after STOP 0,0.2,5 0,0.20.0 0.99% 0,0.2.5 0,0.25,5 2400 Kbaud 4800 Kbaud 9600 Kbaud 19200 Kbaud straight straight parity control RS422A, link Function disabled Function enabled Read prohibited Read allowed Disabled Enabled 0,01 30000 max. frequency n070 n071 146H 147H n072 148H Parity n073 n074 n075 n077 10ms 149H 14AH 14BH 14DH Send waiting time control speed carrier frequency reduction Select prevent accidently overwriting constants stored EEPROM digital operator Error memory Software number 10.65 n078 n079 14EH 14FH Other recent searchesSi6924AEDQ - Si6924AEDQ Si6924AEDQ Datasheet OAT6224S-OLT-V2-A1-10 - OAT6224S-OLT-V2-A1-10 OAT6224S-OLT-V2-A1-10 Datasheet NII51017-10 - NII51017-10 NII51017-10 Datasheet LHY13433-PF - LHY13433-PF LHY13433-PF Datasheet DB11-DBO - DB11-DBO DB11-DBO Datasheet CPT-230 - CPT-230 CPT-230 Datasheet CM9100 - CM9100 CM9100 Datasheet 0398700709 - 0398700709 0398700709 Datasheet
Privacy Policy | Disclaimer |