Screwless clamping greatly contributes reduc- PYF@@S wiring


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Screwless Clamp Terminal Socket
Screwless clamping greatly contributes reduc-
PYF@@S
wiring time.
over under tightening cable connection
better contact reliability achieved.
Double wiring possible terminals,
easy bridge branch connections.
either solid stranded wires from
(AWG24 AWG16).
Safe terminal arrangement: Coil terminals sepa-
rated from contact terminals.
Unique ejector enables easy relay replacement. types nameplate available:
Legrand.
Finger-protection construction.
Ordering Information
4-pole Socket Nameplate Socket Bridge PYF14S R99-11 nameplate PYDM-14SR, PYDM-14SB PYDM-08SR, PYDM-08SB PYF08S PYCM-08S Clip Release Lever PYCM-14S 2-pole
Specifications
Item Relay Dimensions Rated voltage Rated carry current Applicable wires Series Series
PYF14S Series
PYF08S
Remarks
36.5 max.
23.2 36.5 max. with with
-VDE0627
with (see note) with (AWG24 AWG16) Solid wire Stranded wires
Number wire connec- wires terminal wire hole) tions Clamping force min. (0.2 mm2) min. (1.5 mm2)
-EN60999
Note:
used
Safety Standards
Standard File -E87929 Vol. LR31928
VDE0627 (IEC664, EN60999) UL508 (UL1059) C22.2 (CSA C22.2 158)
PYF@@S
PYF@@S
Dimensions
Note: units millimeters unless otherwise indicated.
PYF14S
36.5 max.
PYF08S
38.2 max. 36.5 max.
max.
23.2 max.
max.
max.
(5.3)
Terminal Arrangement
PYF14S
Common contacts Make contacts Break contacts
PYF08S
Coils
Note: Pole-2 pole-3 cannot used with type. pole-1 (terminal numbers: pole-4 (terminal numbers: 42).
Mounting Height (With Lever)
PYF14S
PYF08S
72.6 typ. 28.6
73.6 typ.
28.6
PYF@@S
PYF@@S
Accessories (Option)
Socket Bridge
Insulating coating
dia. conductor (See note
Note:
relationship between model number, length color insulating coating shown following table. Model number Length (mm) Color insulating coating Blue 19.7 Blue
positions ends insulating coating must vary more than characteristics socket bridge shown following table. Item Rated current Rated insulation voltage Temperature rise Dielectric strength max. 1,500 minute Characteristic
PYDM-14SR PYDM-14SB PYDM-08SR PYDM-08SB
27.5
insulating coating must able withstand voltage 1,500 minute. either material insulating coating.
Ambient operating temper- ature
PYF14S Lever
26.5 typ. 21.5 typ. typ.
PYF08S Lever
typ.
typ.
54.4 typ. typ. 52.5 typ. typ. 32.7 typ. 29.6 typ. typ. 6.41 typ.
Installation
Tools
flat-blade screwdriver should used mount cables.
Applicable Screwdriver
Flat-blade, Parallel-tip, diameter (3.0 max.)
Flat-blade, Parallel-tip
dia. (3.0 max.)
Flat-blade, Flared-tip
Cannot used.
Examples: FACOM AEF.2.5 VESSEL 9900-(-)2.5 WAGO 210-119 WIHA 260/2.5 (AEF. 75E) (No. 9900-(-)3 100) (260/3
*Chamfering driver improves insertion when used exclusive tool.
PYF@@S
PYF@@S
Applicable Wires
Applicable Wire Sizes
mm2, AWG24 AWG16
Applicable Wire Type
Solid wires, stranded wires, flexible wires, wires with ferules used. (See note Diameter (mm) (3.5: note Conductor diameter (mm) length sides (mm) Note: overall diameter wire less than insert wire past conductor. Refer following diagrams.
Wires with Ferules
overall diameter wire over will difficult double wiring.
Examples Applicable Wires (Confirmed Using Catalog Information)
Type wire Equipment wire 2491X BS6004 Switchgear BS6231 Switchgear BS6231 Tri-rated control switchgear Conduit UL1007 UL1015 UL1061 UL1430 Conductor type Flexible Solid Solid Flexible Flexible Stranded Flexible Flexible Flexible Flexible 18AWG 18AWG 16AWG 18AWG
note above.
Recommended wire sizes 0.5, 0.75, 0.5, 0.75 16AWG 18AWG, 16AWG 0.5, 0.75, 1.0,
note above.
Wiring
wires applicable sizes specified above. length exposed conductor should
Fig. Exposed Conductor Length
following wiring procedure. Insert specified screwdriver into release hole located beside wire connection hole where wire inserted.
Insert exposed conductor into wire connection hole.
Insert
Wire connection holes Release holes
Pull screwdriver.
Fig. Wire Connection Holes Release Holes
Wire connection hole Pull
Release hole Insert Screwdriver
Fig. Section Fig.
PYF@@S
PYF@@S
Precautions
Precautions Connection
move screwdriver down, from side side while inserted hole. Doing cause damage internal components (e.g., deformation coil spring cracks housing) cause deterioration insulation. insert screwdriver angle. Doing break side socket result short-circuit.
General Precautions
clip prevent relays floating falling socket. product been dropped ground. Dropping product adversely affect performance. Confirm that socket securely attached mounting track before wiring. socket mounted insecurely fall injure operator. Ensure that socket charged during wiring maintenance. doing result electric shock. pour water cleansing agents product. Doing result electric shock. socket locations subject solvents alkaline chemicals. socket locations subject ultraviolet light (e.g., direct sunlight). Doing result markings fading, rust, corrosion, resin deterioration. dispose product fire.
insert more wires hole. Wires come contact with spring causing temperature rise subject sparks. (There wiring holes each terminal.)
Removing from Mounting Rail
remove socket from mounting rail, insert screwdriver fixture rail, move direction shown below.
Screwdriver
Insert screwdriver along hole wall shown below.
Fixture rail Screwdriver
lubricating liquid, such oil, present screwdriver, screwdriver fall resulting injury operator. Insert screwdriver into bottom hole. possible connect cables properly screwdriver inserted incorrectly.
DIMENSIONS SHOWN MILLIMETERS.
convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527.
Cat. J122-E1-03
interest product improvement, specifications subject change without notice.
OMRON Corporation
Electronics Components Company Electronic Mechanical Components Division H.Q. General Purpose Relay Division Shiokoji Horikawa, Shimogyo-ku Kyoto, 600-8530 Japan Tel: (81)75-344-7089/Fax: (81)75-344-7049
Printed Japan 0901-2M (0300)

Other recent searches


SM10T - SM10T   SM10T Datasheet
PLL520-00D1 - PLL520-00D1   PLL520-00D1 Datasheet
MPFM014D - MPFM014D   MPFM014D Datasheet
MPC942C - MPC942C   MPC942C Datasheet
C8051F305 - C8051F305   C8051F305 Datasheet
BT10-915 - BT10-915   BT10-915 Datasheet
BT10-975 - BT10-975   BT10-975 Datasheet
1604250000 - 1604250000   1604250000 Datasheet
10m053420 - 10m053420   10m053420 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive