The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Oxygen Sensor Interface Boards Accurate oxygen measurement Oxymac


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Oxymac50, DE800 Elecdit
Oxygen Sensor Interface Boards Accurate oxygen measurement
Oxymac Elecdit DE800 sensor interface boards control measurement devices Honeywell's range dynamic highly accurate oxygen sensors. ability these sensors operate without reference makes them ideal many applications including combustion environmental control. Honeywell oxygen sensors using zirconia based sensing elements require external connection electronic measuring circuit control sensor operation signal processing. heating element sensor produces required ZrO2 achieve operational temperature. These interface boards supply sensor with necessary circuits provide this control processing, while also providing sensor calibration. DE800 interface also includes heater supply, Oxymac50 Elecdit require external heater power supply Oxymac50 recently upgraded interface that offers similar performance Elecdit board operates from power supply. DE800 interface offers features Oxymac50 also contains heating element power source. Elecdit interface developed Industrial applications offers level noise protection. operates from supply. Oxymac50 DE800 recommended interfaces applications. interfaces supplied ready mounting into customers' enclosures. Oxymac50 15-pin type connector, DE800 screw connector block Elecdit (0.1 connector.
FEATURES
Provides necessary circuits control Honeywell oxygen sensors Functional testing calibration ambient board format Linear output measured oxygen content voltage current format power consumption
BENEFITS
Removes need implement sensor control circuits within customers' equipment Removes effects barometric application pressure changes sensor drift best accuracy Ease mounting access calibration Flexible interconnection Lower running costs
TYPICAL APPLICATIONS
Heating boiler control Industrial process control Combustion systems Compost systems Environmental control Medical Aerospace
Oxymac50, DE800 Elecdit
TECHNICAL DATA
Oxymac50 Measuring range Power source Other inputs Power consumption (interface) Outputs Accuracy Resolution Operating temperature Storage temperature Dimensions Connector Mates with type mounting holes male connector Calibration, Sensor Pump, Sense Common, Test <250 mA(1) DE800 oxygen (standard) oxygen (option) Calibration, Sensor Pump, Sense, Common, Heater, Test <500 full scale 0.04 mounting holes Screw connector block GMS-10, KGZ-10, KGZ-12 2,5mm Calibration, Sensor Pump, Sense Common <250 Elecdit
V(1), Pulse drive
Notes: warm time other sensor characteristics refer datasheet 100470-EN Factory voltage current output
OPERATING CALIBRATION NOTES Oxymac50
Reset Oxymac50 possible putting power off/on. output signal output signal factory solder bridge JP1. proper operation connected sensor electronic circuit tested with test switch with external signal. After switching test function output signal should indicate lower value. indication proper sensor operation indicated blinking Calibration sensor Oxymac circuit calibrated normal air. After loss power Oxymac50 circuit stores calibration value.
DE800
Heater adjustment heater voltage sensor adjusted with meter PC419. Test function after pressing test button, output lower output signal. Testing with external signal possible terminal Calibration sensor calibrated normal with calibration button. Calibration lost after power loss. sensor functioning properly, blinking. Signal sensor functioning properly pulse signal measured terminal
Elecdit
Adjustment/calibration procedure. interface factory set, sensor replacement follow these instructions. Adjust with Pot1 (internal Adjust with Pot2 reference ±0.2 After approx impulse (blinking) signal should present Apply sensor mbar air, adjust with Pot5 Then apply sensor 1013 mbar adjust with Pot3 Uout Adjust with Pot4 Adjust with Pot5 Uout
www.honeywell.com/sensing
Oxygen Sensor Interface Boards
MOUNTING DRAWINGS, REFERENCE ONLY OXYMAC50 DE800
System pulse Test System Black Blue Yellow Yellow
OXYMAC
TEST
PC419
TEST
Power supply voltage
Measuring result
(Blue) (Red) (Black)
SENSOR (GMS-10)
Calibration Test
SENSOR
Heater voltage
(Yellow)
ELECDIT
ORDER GUIDE
Oxymac 50.V.1 Oxymac 50.V.2
Oxymac50 circuit, output 10V, measuring range Oxymac50 circuit, output 10V, measuring range Oxymac50 circuit, output 20mA, measuring range Oxymac50 circuit, output 20mA, measuring range DE800 circuit, output 10V, measuring range DE800 circuit, output 10V, measuring range DE800 circuit, output 20mA, measuring range DE800 circuit, output 20mA, measuring range Elecdit circuit, ouput 10V, measuring range Elecdit circuit, ouput 10V, measuring range
Honeywell Sensing Control
Oxymac 50.A.1
drive test power supply power supply power supply (Red) (Blue) (Black) Test (amplified signal) Output signal
Oxymac 50.A.2 DE800.V.1 DE800.V.2
Power supply Heater Power supply Heater (Yellow
DE800.A.1 DE800.A.2 Elecdit.V.1 Elecdit.V.2
SENSOR
WARNING
MISUSE DOCUMENTATION
information presented this product sheet reference only. this document product installation guide. Complete installation, operation, maintenance information provided instructions supplied with each product. Failure comply with these instructions could result death serious injury.
WARRANTY/REMEDY
Honeywell warrants goods manufacture being free defective materials faulty workmanship. Honeywell's standard product warranty applies unless agreed otherwise Honeywell writing; please refer your order acknowledgement consult your local sales office specific warranty details. warranted goods returned Honeywell during period coverage, Honeywell will repair replace, option, without charge those items finds defective. foregoing buyer' remedy foregoing buyer's sole remedy
SALES SERVICE
Honeywell serves customers through worldwide network sales offices, representatives distributors. application assistance, current specifications, pricing name nearest Authorized Distributor, contact your local sales office E-mail: info.sc@honeywell.com Internet: Internet: www.honeywell.com/sensing Phone Fax: Asia Pacific Europe 6355-2828 6445-3033 1698 481481 1698 481676 Latin America +1-305-805-8188 +1-305-883-8257 USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545
WARNING
PERSONAL INJURY
these products safety emergency stop devices other application where failure product could result personal injury. Failure Failure comply with these instructions result instructions could result death injury serious injury.
warranties, expressed lieu warranties, expressed implied, including those merchantability merchantability fitness particular particular purpose. event shall Honeywell liable indirect consequential, special, indirect damages. While provide application assistance personally, through literature Honeywell site, customer determine suitability product application. Specifications change without notice. information supply believed accurate reliable this printing. However, assume responsibility use.
Automation Control Solutions Sensing Control Honeywell Newhouse Industrial Estate Motherwell, 5SB, www.honeywell.com
100480-EN UK07 2005 Copyright 2005 Honeywell International Inc.

Other recent searches


UNR32A9 - UNR32A9   UNR32A9 Datasheet
SN74ACT00 - SN74ACT00   SN74ACT00 Datasheet
SLD234VL - SLD234VL   SLD234VL Datasheet
LTC3780 - LTC3780   LTC3780 Datasheet
INA-54063 - INA-54063   INA-54063 Datasheet
GP1S38 - GP1S38   GP1S38 Datasheet
GP1S381 - GP1S381   GP1S381 Datasheet
GP1S38 - GP1S38   GP1S38 Datasheet
GP1S381 - GP1S381   GP1S381 Datasheet
BF256A - BF256A   BF256A Datasheet
1071010000 - 1071010000   1071010000 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive