DIGITAL PRESSURE SENSOR DP-100 Conforming Directive SER
Top Searches for this datasheetPRESSURE SENSOR DIGITAL PRESSURE SENSOR DP-100 Conforming Directive SERIES recognition pending Global Standard Dual display digital pressure sensors future Industry first. Dual 3-color display makes operation easier! dual display means that `current value' `threshold value' displayed same time improve ease operation visual checking. Introducing standard digital pressure sensor technology. November 2005 based research conducted SUNX 1.181 square sized digital pressure sensors. global standard `Current value' `threshold value' checked same time! Dual display allows direct setting threshold value Threshold value setting method Equipped with 1.181 square compact-sized dual display. Because current value threshold value checked same time, threshold value checked smoothly without having switch screen modes. operations still carried while threshold values being set, setting same sensitivity dial control-type sensors possible. naturally lock function also equipped. Previous model with single display -91.8 Note current value Operate MODE Adjust threshold value Return operation DP-100 with dual display Simply press button during operation Man-hours reduced 3-color display (Red, Green, Orange) main display changes color line with changes status output operation, also changes color while setting progress. sensor status therefore understood easily, operating errors reduced. OFF: Green Red) Main Display Green) SET: Orange Readable digital display! segments used alphanumeric display been adopted. This improves visual checking letters numbers. During normal operation During setting Dual Display Direct setting Current value Threshold value tting Works like dial control type sensor Main display Comparative Output operation indicator Comparative Output operation indicator Multi-function type: Analog voltage output opertaion indicator display Mode selection Increment Decrement Copy function lets work carried accurately quickly Copy function reduces man-hours human error Sensors connected master sensor one, copy setting details master sensor transmitted data other sensors. making same settings multiple sensors, this prevents setting errors from occurring with other sensors also reduces number changes required instruction manuals when equipment designs changed. Setting details copied. Details transmitted Copying wiring Master sensor Power supply Comparative output Comparative output Slave sensor Details received Comparative output Detail Comparative output Advantage Setting man-hours reduced sensor setting time shortened. equipment: minutes approx. Number pressure sensor: equipment line equipment: minutes approx. setting details master sensor retained, continuous copying possible! subsequent lines, only data transmission time needed. minutes approx. equipment: minutes approx. equipment: minutes equipment: approx. equipment: equipment: equipment: minutes approx. Master sensor equipment: minutes equipment: approx. equipment: equipment: Sensor setting time: Sensor setting time: Sensor setting time: minutes approx. minutes seconds approx. seconds approx. Previously DP-100, line DP-100, line Advantage Human operating error reduced. Because details copied automatically, prevents problems occurring result human error. Instruction manuals updated easily when changes occur equipment design! Setting smooth easy sensor's setting operation mode 3-level configuration suit frequency use. setting levels clearly separated into `RUN mode' operation settings that carried daily, `MENU SETTING mode' basic settings, `PRO mode' special detailed setting. These make setting operations easy understand easy carry out. mode Settings such threshold value adjustment lock operation carried while sensor operating. Simple setting mode MENU SETTING mode Basic settings such output mode setting switching carried out. MENU SETTING mode Special detailed setting mode mode High-level function settings such hysteresis adjustment copy function carried out. Display orange while setting progress display appears green during operation, changes orange while setting progress, that sensor status viewed glance. operation mode While setting MENU SETTING mode mode green when output Orange while setting progress Default settings that used straight away Easy-to-use default settings provided applications that used frequently pressure sensors. default settings pressure types ideal suction checking applications, those high pressure types ideal checking reference pressure. Buttons with good clicking touch buttons have good clicking touch, allowing smooth setting. pressure type Comparative output Hysterisys 3digits Ideal checking suction High pressure type Comparative output Hysterisys 3digits Ideal checking reference pressure clicking feeling transmitted even through gloves. Reset function problem ever occurs with sensor settings, they returned default settings. Full range performance functions compact body models line-up compound pressure types sensor settings required switch between positive pressure negative pressure, that number registered part numbers decreased. Realizes high performance pressure type pressure type displays measurements resolution 1/2000 response time (variable 5,000 ms), F.S. temperature characteristics F.S. repeatability, giving high performance. <For pressure> Ideal applications such suction. misoperations vacuum breakdown occur. <For high pressure> Ideal applications such checking reference pressure. also used simple suction. pressure high pressure Resolution: 1/2,000 Response time: Temperature characteristics: F.S. Repeatability: F.S. DP-101 Displays measurements DP-102 Equipped with independent dual output Standard type Equipped with independent comparative outputs, separate sensing modes selected each them. comparative outputs even used alarm output. addition, output being used, disabled. Three output modes suitable wide range applications Pressure EASY mode This mode used comparative output control. Vacuum breakdown also checked during suction applications! (Hysteresis) Comparative output EASY mode Comparative output Suction checking Fixed Notes: Hysteresis fixed eight different levels. appears display comparative output appears comparative output Comparative output EASY mode Vacuum breakdown checking Pressure Hysteresis mode This mode used setting comparative output hysteresis desired level carrying control. (Hysteresis) Reference pressure alarm output possible during reference pressure checking! Comparative output hysteresis mode Reference pressure checking Comparative output digit more Note: output appears display comparative appears comparative output Pressure Comparative output EASY mode Lo-1 Hi-1 Alarm output Window comparator mode This mode used setting comparative output pressures within setting range. (Hysteresis) (Hysteresis) Comparative output Fixed Notes: Hysteresis fixed eight different levels. appears display comparative output appears comparative output Switching possible between analog voltage output external input Multi-function type Multi-function type available that allows selection analog voltage output external input (auto-reference remote zero-adjustment). This suitable multi-specification applications. Comparative output ANALOG lights pressure type: High pressure type: Auto-reference remote zero-adjustment Analog voltage output Select Multi-function type External input Equipped with auto-reference remote zero-adjustment functions Multi-function type More precise pressure management possible with minimum effort reference pressure device changes, autoreference function partially shift comparative output judgment level amount that reference pressure shifts, remote zeroadjustment function reset display value zero external input. These functions ideal places where reference pressure fluctuates wildly, where fine settings desired. Without auto-reference remote zero-adjustment functions Comparative output: Window comparator mode Hi-1 Lo-1 Fixed value Variation filling pressure Trial Trial Trial Leak threshold level Pressure Time Because threshold level fixed conventional pressure sensors, changes reference pressure result wrong decisions. With auto-reference function applied Comparative output: Window comparator mode Hi-1 Lo-1 Sets absolute threshold level Auto-reference input display remains `30' only threshold level changed. With remote zero-adjustment function applied Comparative output: Window comparator mode Hi-1 Lo-1 Sets absolute threshold level Remote zero-adjustment input display forced `0', only filling pressure drop range displayed. Threshold level after applying auto-reference input Threshold level before applying auto-reference input Trial Threshold level after applying remote zero-adjustment input Threshold level before applying remote zero-adjustment input Trial Pressure Time Auto-reference input value Pressure Time Displayed when remote zeroadjustment input applied When auto-reference input applied, reference pressure `30' added threshold level. reference pressure changes `20' `40', auto-reference input compensates this every time changing threshold level, variation filling pressure ignored. When remote zero-adjustment input applied, reference pressure forced `0'. reference pressure changes `20' `40', remote zero-adjustment input adjusts reference pressure every time reference pressure changes, variation filling pressure ignored. Other useful functions display customized display indicate other desired values letters apart from threshold value. This eliminates need tasks such affixing label device indicate normal pressure value. Setting details understood glance DP-100 setting details appear digital display. Because settings numeric form that easily understood, useful times such when receiving technical support telephone. What check codes setting? code main display 3205. display reads 7011. digit: Setting status comparative output digit: Setting status comparative output digit: Threshold value setting digit: Display color setting Indicates desired values letters <Unit display> <Number display> <Desired letter display> digit: Response time setting digit: Display unit setting digit: mode setting digit: Display refresh rate setting Peak hold Bottom hold functions peak values bottom values fluctuating pressures displayed using dual display. Energy-saving design! Equipped with mode This mode lowers display luminance power consumption approximately displays also turned completely achieve power saving approximately Power consumption Power consumption Normal ECO-STD less Approx. ECO-FULL less Approx. Blinks alternately Current consumption power supply: less Current consumption power supply: less Current consumption power supply: less Response time changed response time changed levels from 5,000 This prevents chattering incorrect operation sudden changes pressure. Pressure Threshold value Temporary change fluctuation Display refresh rate varied display refresh rate digital displays changed three settings: 1,000 Flickering display reduced making display refresh rate longer. Incorrect operation prevented Output Installation also easy! Tight installation panels possible exclusive mounting bracket that suitable 0.039 0.236 panel thickness available. Takes much less space Tight installation possible Front protection cover available MS-DP1-3 single mounting hole! exclusive mounting bracket (MS-DP1-1) that supports tight installation available Space savings also obtained L-shaped mounting bracket used. Tight installation possible Ceiling mounting Floor mounting Positioning bosses easier mounting bracket installation Cable connected with one-touch connection accessory connector attached cable 6.562 connected easily with one-touch connection. Types without connector attached cable also available DP-10 Commercially-available connectors used cable connections. Only required length cable needs used, which contributes reduced amount wastage unneeded cable. Environmentally friendly Connection cable Options: 3.281 9.843 16.404 types also available. Commercially-available parts used! ORDER GUIDE Type pressure Standard Asian high pressure pressure Multi-function high pressure pressure European Standard high pressure pressure Multi-function high pressure pressure North American Standard high pressure Appearance Rated pressure range 100.0 0.100 100.0 0.100 100.0 0.100 100.0 0.100 100.0 100.0 Model DP-101 Pressure port Comparative output 1.000 DP-102 100.0 female thread (PT) male thread open-collector transistor DP-101A 1.000 DP-102A 100.0 DP-101-E-P female thread male thread open-collector transistor 1.000 DP-102-E-P 100.0 DP-101A-E-P 1.000 DP-102A-E-P 100.0 DP-101-N DP-101-N-P open-collector transistor open-collector transistor open-collector transistor female thread male thread open-collector transistor open-collector transistor open-collector transistor open-collector transistor open-collector transistor mCN-14A-C2 Connector attached cable 6.562 attached. 0.100 1.000 DP-102-N DP-102-N-P pressure Multi-function high pressure 100.0 100.0 DP-101A-N DP-101A-N-P 0.100 1.000 DP-102A-N DP-102A-N-P Types without connector attached cable Types without connector attached cable available. When ordering this type, `-J' Model Model DP-101-J, DP-101-E-P-J, DP-101-N-J, DP-101-N-P-J DP-102-J, DP-102-E-P-J, DP-102-N-J, DP-102-N-P-J Accessory CN-14A-C2 (Connector attached cable 6.562 OPTIONS Sensor mounting bracket Designation Model CN-14A-C1 CN-14A-C3 CN-14A-C5 CN-14A market soon 3.281 9.843 16.404 Description 4-core cabtyre cable with connector Cable outer diameter: "3.7 "0.146 MS-DP1-1 (length 0.236 screws with washers Accessory (MS-DP1-1 Sensor mounting bracket MS-DP1-1 Connector attached cable Connector Sensor mounting bracket Panel mounting bracket Front protection cover housings contacts Allows sensors installed face direction floor ceiling. Multiple sensors also mounted closely. Allows installation panels with thickness 0.039 0.236 Protects adjustment surfaces sensors. (Can attached when using panel mounting bracket) MS-DP1-1 MS-DP1-2 MS-DP1-3 Panel mounting bracket, Front protection cover MS-DP1-2 MS-DP1-3 (length 0.472 tapping screw (Accessory MS-DP1-2) Front protection cover MS-DP1-3 Panel mounting bracket MS-DP1-2 DP-100 SPECIFICATIONS Type Model Asian European North American (Note Standard pressure DP-101 DP-101-E-P DP-101-N(-P) 100.0 100.0 Multi-function high pressure DP-102 DP-102-E-P DP-102-N(-P) 0.100 1.000 Gauge pressure 100.0 100.0 0.100 1.000 pressure DP-101A DP-101A-E-P DP-101A-N(-P) high pressure DP-102A DP-102A-E-P DP-102A-N(-P) Item Type pressure Rated pressure range pressure range 100.0 100.0 1.020 1.020 kgf/cm2 1.000 1.000 14.50 14.50 mmHg 29.5 29.5 inHg 0.100 1.000 1,000 1.02 10.20 kgf/cm2 1.00 10.00 14.6 145.0 100.0 100.0 1.020 1.020 kgf/cm2 1.000 1.000 14.50 14.50 mmHg 29.5 29.5 inHg 0.100 1.000 1,000 1.02 10.20 kgf/cm2 1.00 10.00 14.6 145.0 Pressure withstandability Applicable fluid Selectable unit Supply voltage Power consumption Non-corrosive pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, high pressure: MPa, kPa, kgf/cm2, bar, Ripple less Normal operation: less (Current consumption less supply voltage) mode: less (Current consumption less supply voltage) less FULL (Current consumption less supply voltage) <Asian, North American (NPN output)> Comparative output open-collector transistor Maximum sink current: Applied voltage: less (between comparative output Residual voltage: less sink current) <European, North American (PNP output)> open-collector transistor Maximum source current: Applied voltage: less (between comparative output Residual voltage: less source current) Output operation Output modes Hysteresis Repeatability Response time Short-circuit protection External input Auto-reference function Remote zero-adjustment function F.S. (within digits) (selectable operation) EASY mode Hysteresis mode Window comparator mode Minimum digit (variable) (however, digits when using unit) F.S. (within digits) F.S. (within digits) F.S. (within digits) 1,000 5,000 selectable operation Incorporated <Asian, North American (NPN output)> <European, North American (PNP output)> voltage: less voltage: open Input impedance: approx. Input time: more Output voltage: Zero point: within F.S. Span: within F.S. F.S. Linearity: within Output impedance: approx. voltage: voltage: less, open Input impedance: approx. Input time: more Output voltage: Zero point: within F.S. Span: within F.S. F.S. Linearity: within Output impedance: approx. Analog voltage output Display Displayable pressure range Indicator Environmental resistance Pollution degree Ambient temperature Ambient humidity Voltage withstandability Insulation resistance Vibration resistance Shock resistance digits 3-color display (Display refresh rate: 1,000 selectable operation) digits 100.0 100.0 100.0 100.0 0.100 1.000 0.100 1.000 1.020 1.020 kgf/cm2 1.020 1.020 kgf/cm2 1,000 1,000 1.000 1.000 1.000 1.000 1.02 10.20 kgf/cm2 1.02 10.20 kgf/cm2 14.50 14.50 14.50 14.50 1.00 10.00 1.00 10.00 mmHg mmHg 29.5 29.5 inHg 14.6 145.0 29.5 29.5 inHg 14.6 145.0 Orange Orange Comparative output operation indicator, comparative output operation indicator: Comparative output operation indicator: Lights when comparative output Lights when each comparative output Analog voltage output operation indicator: Lights when setting IP40 (IEC) Storage: condensation icing allowed), Storage: 1,000 min. between supply terminals connected together enclosure more, with megger between supply terminals connected together enclosure frequency, 0.118 amplitude, directions hours each (when panel mounted: frequency, 0.75 0.030 amplitude, directions hours each) m/s2 acceleration approx.) directions three times each Within F.S. Within F.S. Within F.S. Within F.S. Temperature characteristics Pressure port Material Connecting method Cable extension Weight Accessories Asian: female thread (PT) male thread, European: female thread male thread, North American: female thread male thread Enclosure: (glass fiber reinforced), display: Acrylic, Pressure port: Brass (nickel plated), Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber Connector Extension total 328.084 (less than 32.808 when conforming marking) possible with mm2, more, cable weight: approx., Gross weight: approx. CN-14A-C2 (Connector attached cable 6.562 ft): 1pc. Notes: Where measurement conditions have been specified precisely, conditions used were ambient temperature Model Nos. North American standard type having suffix `-P' output type. DP-100 CIRCUIT WIRING DIAGRAMS output type circuit diagram Standard type Terminal Color code connector attached cable Terminal arrangement diagram (Brown) Sensor circuit (Black) Load Comparative output Load max. (White) Comparative output max. (Blue) Users' circuit Terminal Designation Comparative output Standard type: Comparative output Multi-function type: Analog voltage output External input Internal circuit Symbols Reverse supply polarity protection diode ZD1, Surge absorption zener diode Tr1, output transistor Terminal Multi-function type Sensor circuit Color code connector attached cable (Brown) (White) Analog voltage output External input Load (Black) Comparative output max. (Blue) Users' circuit Internal circuit Symbols Reverse supply polarity protection diode Surge absorption zener diode input transistor output transistor output type circuit diagram Standard type Terminal Color code connector attached cable Terminal arrangement diagram (Brown) Sensor circuit max. (Black) Comparative output max. Load (White) Comparative output Load (Blue) Terminal Designation Comparative output Standard type: Comparative output Multi-function type: Analog voltage output External input Internal circuit Users' circuit Symbols Reverse supply polarity protection diode ZD1, Surge absorption zener diode Tr1, output transistor Terminal Color code connector attached cable Multi-function type (Brown) Sensor circuit max. (Black) Comparative output (White) Analog voltage output Load External input (Blue) Users' circuit Internal circuit Symbols Reverse supply polarity protection diode ZD1: Surge absorption zener diode output transistor input transistor DP-100 PRECAUTIONS PROPER Never this product sensing device personnel protection. case using sensing devices personnel protection, products which meet regulations standards, such OSHA, ANSI etc., personnel protection applicable each region country. DP-100 series designed with noncorrosive gas. cannot used with liquid corrosive gas. Piping connecting commercially-available coupling pressure port, attach 0.472 spanner 0.551 spanner DP-100-E type) hexagonal section pressure port secure tighten torque less. tightened using excessive torque, damage coupling pressure port. addition, wrap sealing tape around coupling when connecting prevent leaks. 0.472 spanner Wiring Make sure that power supply while wiring. Verify that supply voltage variation within rating. power supplied from commercial switching regulator, ensure that frame ground (F.G.) terminal power supply connected actual ground. case noise generating equipment (switching regulator, inverter motor, etc.) used vicinity this sensor, connect frame ground (F.G.) terminal equipment actual ground. wires together with high-voltage lines power lines them same raceway. This cause malfunction induction. Incorrect wiring will cause problems with operation. Others within rated pressure range. apply pressure exceeding pressure withstandability value. diaphragm will damaged correct operation shall maintained. during initial transient time (0.5 sec. approx.) after power supply switched Avoid dust, dirt, steam. Take care that sensor does come direct contact with water, oil, grease, organic solvents, such thinner, etc. insert wires, etc., into pressure port. diaphragm will damaged correct operation shall maintained. operate keys with pointed sharp objects. Connection apply stress directly connection cable leader connector. Connector attached cable (CN-14A-C mode This normal operating mode. Setting item Threshold value setting Description threshold values operation changed directly pressing increment (UP) decrement (DOWN). This forces pressure value display reset zero when pressure port open atmospheric pressure side. Stops operations from being accepted. Displays peak value bottom value fluctuating pressure. peak value appears main display, bottom value appears display. Conditions conformity DP-100 series conformity product complying with Directive. harmonized standard with regard immunity that applies this product 61000-6-2 following condition must conform that standard. Condition sensor should connected less than 32.808 from power supply. Zero-adjustment function lock function Peak hold bottom hold function MENU SETTING mode Mounting MS-DP1-1 sensor mounting bracket available separately, should used mounting. When tightening sensor sensor mounting bracket, tightening torque less. (length 0.236 screws with washers (Accessory MS-DP1-1) mode selection pressed held seconds mode, mode will switch MENU SETTING mode. mode selection pressed while setting being made, mode will switch mode. this case, settings that have been changed will entered. Setting item Comparative output output mode setting Description Sets output mode comparative output Comparative output output mode Sets output mode comparative output setting (standard type only) Sensor mounting bracket MS-DP1-1 (Optional) Analog voltage output external input switching (multi-function type only) switching Allows switching between analog voltage output auto-reference input remote zero-adjustment input. Sets normally open (NO) normally closed (NC). Sets response time. response time selected from 1,000 5,000 Allows color main display changed. colors `red green' `green red' correspond output, fixed `red' `green' time. Pressure unit changed. MS-DP1-2 panel mounting bracket (optional) MS-DP1-3 front protection cover (optional) also available. (length 0.472 tapping screw (Accessory MS-DP1-2) Response time setting Front protection cover MS-DP1-3 (Optional) Display color switching main display Unit switching Panel mounting bracket MS-DP1-2 (Optional) DP-100 PRECAUTIONS PROPER mode mode selection pressed held seconds mode, mode will switch mode. mode selection pressed while setting being made, mode will switch mode. this case, settings that have been changed will entered. Setting item display switching Display refresh rate switching Hysteresis value switching Linked display color switching (standard type only) mode setting Setting check code Setting copy mode Reset setting Table codes digit Code digit Standard type Multi-function digit type digit Standard type only Comparative output Comparative output Analog voltage output Threshold Display color Display output mode switching output mode switching External input value display main display color linking Description Changes information display during mode operation desired alphanumeric display. Changes display refresh rate pressure value displayed main display. Sets response time EASY mode window comparator mode. steps) Allows display color main display switched line with output operation comparative output comparative output Allows power consumption reduced dimming display turning off. Allows setting details checked codes. Allows setting details master sensor copied slave sensors. Resets settings factory settings. EASY EASY Hysteresis Hysteresis Window comparator Analog voltage P-1, Lo-1 output when Autoreference Hi-1 Comparative output Comparative output Remote Comparative P-2, Lo-2 zero-adjustment output Green when Comparative Hi-2 output ADJ. Comparative Always output Comparative output Comparative Always output green Comparative output Window comparator Code digit Response time 1,000 5,000 digit Unit switching kgf/cm2 mmHg inchHg digit Display reflesh rate 1,000 digit mode FULL DIMENSIONS (Unit: DP-10 Sensor 1.181 data dimensions downloaded from SUNX website: http://www.sunx.co.jp/ 42.5 1.673 25.5 1.004 0.295 0.374 0.787 Connector 1.181 (PT) male thread (North American: 0.787 0.472 0.059 female thread female thread, 0.157 deep European 0.394 0.276 European 0.551 male thread DP-100 DIMENSIONS (Unit: MS-DP1-1 data dimensions downloaded from SUNX website: http://www.sunx.co.jp/ Sensor mounting bracket (Optional) "2.3 "0.091 Assembly dimensions 0.866 2-R2.1 R0.083 0.374 14.5 0.571 0.165 25.5 1.004 42.5 1.673 14.5 0.571 0.374 0.165 0.039 2-R2.1 R0.083 0.866 1.181 0.787 0.512 2-"3.5 "0.138 0.295 1.772 0.209 1.732 0.217 1.181 1.181 1.772 0.591 0.059 0.374 0.472 1.181 0.787 R0.512 0.079 0.787 0.079 MS-DP1-2 MS-DP1-3 Panel mounting bracket (Optional), Front protection cover (Optional) Panel cut-out dimensions When unit installed 1.220 0.016 Assembly dimensions 1.220 39.3 1.547 34.5 1.358 34.5 1.358 0.787 2.165 more Panel thickness dimensions 0.039 0.236 0.283 0.433 18.3 0.720 0.295 0.374 0.016 When units installed horizontally series When units installed vertically series 1.220 0.138 (n-1) 1.220 0.016 1.220 0.016 1.969 33.4 1.315 33.4 1.315 0.945 0.343 1.220 0.138 (n-1) 2.165 more Note: panel thickness should 0.039 0.236 Note: panel thickness should 0.039 0.236 CN-14A-C Connector attached cable (Optional, CN-14A-C2 attached sensor) 0.315 1.378 (1.969) (0.315 Model CN-14A-C1 CN-14A-C2 Cable length (mm, 1,000 39.370 2,000 78.740 3,000 118.110 5,000 196.850 "3.7 "0.146 cable CN-14A-C3 CN-14A-C5 Compact Size 2-color Digital Display SERIES shape makes most suitable panel installation Light-weight, compact design compact form specifically designed mounting equipment panel. only uses half space conventional product provides lightest weight just (cable excluded). 40mm Bright, easy view twocolor digital display digital display large, easy-to-view, two-color digital display. also functions output indicator changes from green color when output turns enabling confirm output status glance. Conforming Directive Recognition 60mm Supplied with simple-tomount panel mounting bracket panel mounting bracket (MS-DP-1) enclosed enable simple mounting sensor onto panel surface, thus contributing total cost reduction. Rated pressure range: DP4-50/50P 101.3 DP4-52/52P 1.000 100.0 100.0 DP4-57/57P Applicable fluid: Non-corrosive Supply voltage: Output: DP4-5 open-collector transistor DP4-5 open-collector transistor Pressure port: female thread Dimensions: Head-separated Type 2-color Digital Display SERIES Controller SERIES Sensor head 1/1,000 second high-speed response! Response time Mounting detachable head close detecting section minimizes piping enables response time well greatly decreasing tact time delay. addition, ultra-small light-weight design head means easily mounted moving sections. Independent sensor head possible Light-weight, compact design controller inherits lightweight, compact design from popular series digital pressure sensors. Control panel setup cost requires minimal space. Conforming Directive Recognition Pressure sensor heads Rated pressure range: DPH-A 101.3 DPH-A 1.000 DPH-A 100.0 100.0 Applicable fluid: Non-corrosive Supply voltage: Analog voltage output: (over rated pressure range) Pressure port: DPH-A0 male thread, DPH-A1 (PT) male thread female thread DPH-A2 male thread 10-32UNF female thread DPH-A30 10-32UNF male thread Dimensions: DPH-A0 /A30 12.5 DPH-A1 12.5 Sensor head with operation indicator sensor head also equipped with operation indicator. Output checked sensor head, that suitable checking operation suction head. Convenient intermediate cable with connector Intermediate cable with connectors connecting sensor head controller makes operation maintenance easier. Note: intermediate cable required connect controller sensor head. Please order intermediate cable with connector separately. Pressure sensor controllers Applicable pressure sensor head: DPH-A Rated pressure range: Vacuum pressure 101.3 Positive pressure 1.000 Compound pressure 100.0 100.0 Supply voltage: Comparative Output (Comparative output Comparative output DP5-C open-collector transistor DP5-C-P open-collector transistor Analog voltage output: (over rated pressure range) Dimensions: information subject change without prior notice. SUNX Limited 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-(0)568-33-7211 FAX: +81-(0)568-33-2631 Overseas Sales Dept. http://www.sunx.co.jp/ Phone: +81-(0)568-33-7861 FAX: +81-(0)568-33-8591 Printed 100% recycled paper PRINTED JAPAN No.CE-DP100-10 January, 2006 Other recent searchesSTK4171V - STK4171V STK4171V Datasheet Si3586DV - Si3586DV Si3586DV Datasheet LUR50333 - LUR50333 LUR50333 Datasheet ISO15 - ISO15 ISO15 Datasheet ISO35 - ISO35 ISO35 Datasheet GBU10005 - GBU10005 GBU10005 Datasheet GBU1010 - GBU1010 GBU1010 Datasheet 1N6128US - 1N6128US 1N6128US Datasheet
Privacy Policy | Disclaimer |