RECEPTACLE ASSEMBLY TERMINAL INSERTION Begin assembly crimped fem


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



MX150/MX150L ASSEMBLY INSTRUCTIONS
RECEPTACLE ASSEMBLY
TERMINAL INSERTION Begin assembly crimped female terminals into receptacle housing making sure Terminal Position Assurance feature (TPA) pre-locked position (See Figure not, insert blade screwdriver into slots found adjacent latch opposite. Apply slight pressure until clicks. ready insert terminals circuit plugs.
Figure Pre-Lock Position
terminal must positioned correctly when inserted into housing assure proper latching retention. Orient back female terminal with keyway wire entry cavity rear housing (See Figure Insert terminal into housing until clicks slight pull back wire with resistance from terminal retention feature.
Keyway Wire Entry
Terminal
Figure Terminal Orientation
REVISION: ECR/ECN INFORMATION: TITLE: ETC2004-0125 DATE: 2003
ASSEMBLY INSTRUCTIONS MX150 MX150L SEALED CONNECTOR SYSTEM
CHECKED
SHEET
DOCUMENT NUMBER:
CREATED REVISED
APPROVED
AS-19417-001
C.T.WALSH
J.PAWLICKI
R.DeROSS
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A](V.1).DOC
MX150/MX150L ASSEMBLY INSTRUCTIONS
Repeat Step until terminals inserted into housing. using circuit plug seal unused circuit, same procedure terminal insertion applied. terminal inadvertently assembled into wrong position, service tool remove. When terminals circuit plugs their proper location, push down until clicks into place roughly flush same level edge outer housing (See figure
Flush with Outer Housing
Figure Locked Position
CONNECTOR POSITION ASSURANCE ACTIVATION After mating plug receptacle connectors, push Connector Position Assurance feature (CPA) receptacle forward until clicks forward towards mating receptacle possible (See Figure This will prevent accidental depression latch un-mating connectors.
Forward Position
Figure Locked Position
un-mate connectors, pull towards rear wire entry receptacle. While lightly pushing connectors together, depress latch then pull mated connectors apart.
REVISION: ECR/ECN INFORMATION: TITLE: ETC2004-0125 DATE: 2003
ASSEMBLY INSTRUCTIONS MX150 MX150L SEALED CONNECTOR SYSTEM
CHECKED
SHEET
DOCUMENT NUMBER:
CREATED REVISED
APPROVED
AS-19417-001
C.T.WALSH
J.PAWLICKI
R.DeROSS
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A](V.1).DOC
MX150/MX150L ASSEMBLY INSTRUCTIONS
PLUG ASSEMBLY
TERMINAL INSERTION Begin assembly crimped male terminals into plug housing making sure Terminal Position Assurance feature (TPA) pre-locked position (See Figure Since recessed housing, most accurate determine pre-lock position measure. pre-locked position dimension between plug housing face approximately 0.500"(12,7mm). pre-locked position, insert tips needle nose pliers into shaped holes center TPA. Carefully, pull gently until starts moving. Pull first stop. CAUTION: PULL COMPLETELY HOUSING. THIS BREAK RETENTION FEATURES RESULT REDUCED RETENTION HOUSING. ready insert terminals circuit plugs.
0.500" (12.7mm)
Figure Pre-Locked Position
terminal must positioned correctly when inserted into housing assure proper latching retention. Orient back male terminal with keyway rear housing (See Figure Insert terminal into housing until clicks slight pull back wire with resistance from terminal retention feature.
Keyway Wire Entry Terminal
Figure Terminal Orientation
REVISION: ECR/ECN INFORMATION: TITLE: ETC2004-0125 DATE: 2003
ASSEMBLY INSTRUCTIONS MX150 MX150L SEALED CONNECTOR SYSTEM
CHECKED
SHEET
DOCUMENT NUMBER:
CREATED REVISED
APPROVED
AS-19417-001
C.T.WALSH
J.PAWLICKI
R.DeROSS
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A](V.1).DOC
MX150/MX150L ASSEMBLY INSTRUCTIONS
Repeat Step until terminals inserted into housing. using circuit plug seal unused circuit, same procedure terminal insertion applied. terminal inadvertently assembled into wrong position, service tool remove. When terminals circuit plugs their proper location, push down until clicks into place approximately 0.700"(17.8mm) from mating edge outer housing (See figure
0.700" (17.8mm) Figure Locked Position
CONGRATULATIONS! HAVE MOST RELIABLE, ENVIRONMENTALLY SEALED (IP67) CONNECTOR SYSTEMS AVAILABLE!
REVISION:
ECR/ECN INFORMATION: TITLE: ETC2004-0125 DATE: 2003
ASSEMBLY INSTRUCTIONS MX150 MX150L SEALED CONNECTOR SYSTEM
CHECKED
SHEET
DOCUMENT NUMBER:
CREATED REVISED
APPROVED
AS-19417-001
C.T.WALSH
J.PAWLICKI
R.DeROSS
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A](V.1).DOC

Other recent searches


UM0213 - UM0213   UM0213 Datasheet
UCC3973 - UCC3973   UCC3973 Datasheet
UCC3972 - UCC3972   UCC3972 Datasheet
TPCA8011-H - TPCA8011-H   TPCA8011-H Datasheet
CXL1501M - CXL1501M   CXL1501M Datasheet
CXA1200Q - CXA1200Q   CXA1200Q Datasheet
CDBF42 - CDBF42   CDBF42 Datasheet
43-HF - 43-HF   43-HF Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive