| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
PART NUMBER: VSCP-800 series DESCRIPTION: switching power supply
Top Searches for this datasheetPART NUMBER: VSCP-800 series DESCRIPTION: switching power supply features sharing capability output voltage input circuit, overload, over voltage, over temperature protected cooling built-in failure signal remote sense remote inhibit year warranty model VSCP-800-09 VSCP-800-12 VSCP-800-15 VSCP-800-18 VSCP-800-24 VSCP-800-36 VSCP-800-48 VSCP-800-60 output output current minimum maximum 44/88 33/66 26/53 22/44.4 16/33 11/22.2 8/16 6/13 ripple noise max. power regulation (Vpp) efficiency notes: output voltage measured output power connector. maximum current measured 100-120V input 200-240V input ripple noise measured from output terminals with ceramic capacitor electrolytic capacitor parallel. INPUT parameter input frequency input voltage inrush current input current conditions/description 100~120 200~240 (see derating curve) (130~185 260~370) (VDC derating curve) peak measured full load, cold start units 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VSCP-800 series DESCRIPTION: switching power supply OUTPUT parameter hold-up time programming conditions/description full load output voltage programmable through external 0~5V control voltage VCI. control voltage also obtained from KOhm pot. application diagrams. typical adjustment potentiometer 25%-100% adjustment 1-5Vdc external control designated respect designated designated units voltage adjustability temp. coefficient remote sense remote inhibit current sharing -7.5 +7.5 0.04 (VS+) (VS-). total voltage compensation cable losses with main output. (INH), requires signal inhibit output. (PAR), parallel forced current sharing function. PROTECTION CIRCUIT parameter overload overvoltage conditions/description current limiting times (1.5", 3.0", 5.0"), then intelligent auto recovery before shutdown units GENERAL SAFETY parameter operating temp. operating humid. storage temp. storage humid. safety regulation leakage current EN55022, EN610000-4-2,3,4,5,6,8,11, EN61000-3-2-3 ENV50204 approved UL/cUL 1950, EN60950 conditions/description units MECHANICAL parameter weight enclosure conditions/description 290(L) 120(W) 67.5(H) units LOGIC CONNECTOR parameter assignments: conditions/description remote on-off remote inhibit return output ground current sharing parallel function fail detect (must pull resistor) reference output voltage (5-10 VDC) used output programming command input voltage output programming VS(-) remote sense VS(+) remote sense 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VSCP-800 series DESCRIPTION: switching power supply LOGIC CONNECTIONS 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VSCP-800 series DESCRIPTION: switching power supply MECHANICAL DRAWING CONTROL ASSIGMENT Output Voltage Remote Sense+ Output Voltage Remote Sense Command input voltage output programming Power Failure detect 5-10 reference output programming Current Sharing Parallel function Inhibit Remote On-Off Return Output Ground 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VSCP-800 series DESCRIPTION: switching power supply DERATING CURVES load derating curve output power input voltage derating curve 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 Other recent searchesSN75176A - SN75176A SN75176A Datasheet RN4908FE - RN4908FE RN4908FE Datasheet LT1600M-Q21-LU2X3-H1141 - LT1600M-Q21-LU2X3-H1141 LT1600M-Q21-LU2X3-H1141 Datasheet ISO8201 - ISO8201 ISO8201 Datasheet DA0887 - DA0887 DA0887 Datasheet DA089 - DA089 DA089 Datasheet 2SB1565 - 2SB1565 2SB1565 Datasheet
Privacy Policy | Disclaimer |