| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
100°C baseplate operation Converter Watt (300 Watt High density A/in3
Top Searches for this datasheetConverter 100°C baseplate operation Converter Watt (300 Watt High density A/in3 Small footprint 1.64 2.08 Size: 1.91 1.09 0.37 48,6 27,7 Typical efficiency transient response >3.5 million hours MTBF Isolated output output filtering required Lead free wave solder compatible Agency approvals Height above board 0.37 (9.5 weight 1.10 (31.3 Applications Isolated intermediate non-isolated Telecommunication systems Networking Servers isolated sine amplitude converter Product Overview BRICK modules advanced Sine Amplitude Converter(SACTM) technology, thermally enhanced packaging technologies, advanced processes provide high power density efficiency, superior transient response, improved thermal management. These modules used provide isolated intermediate power non-isolated converters fast response time noise BCM, capacitance reduced eliminated near load. Part Numbering Converter Module Input Voltage Designator Package Size Output Voltage Designator (=VOUT x10) Output Power Designator (=POUT /10) Product Grade Temperatures (°C) Grade Operating Storage Baseplate Slotted flange Transverse heat sink[a] contact Style Through hole +100 +125 +100 +125 factory Converter Module BC048A040T020FP vicorpower.com Rev. Page SPECIFICATIONS Electrical characteristics apply over full operating range input voltage, output load (resistive) baseplate temperature, unless otherwise specified. temperatures refer operating temperature center baseplate. Absolute Maximum Ratings Parameter +Out -Out Isolation voltage Output current Peak output current Output power Peak output power Operating temperature Storage temperature Values -1.0 -0.3 -0.5 2,250 +100 +100 +125 +125 Unit Input output Continuous Continuous T-Grade; baseplate M-Grade; baseplate T-Grade M-Grade Notes Note: Stresses excess maximum ratings cause permanent damage device. Operation device implied these other conditions excess those given specification. Exposure absolute maximum ratings adversely affect device reliability. Input Specifications Parameter Input voltage range Input dV/dt Input undervoltage turn-on Input undervoltage turn-off Input overvoltage turn-on Input overvoltage turn-off Input quiescent current Inrush current overshoot Input current Input reflected ripple current load power dissipation Internal input capacitance Internal input inductance (Conditions Vin, full load, 25°C ambient unless otherwise specified) 37.4 32.6 55.0 59.0 Unit V/µs maximum source inductance; Figure Using test circuit Figure Figure Using test circuit Figure Figure Notes Recommended external input capacitance Converter Module BC048A040T020FP vicorpower.com Rev. Page SPECIFICATIONS (CONT.) INPUT WAVEFORMS Figure Inrush transient current full load with enabled Figure Output voltage turn-on waveform with enabled full load Figure Output voltage turn-on waveform with input turn-on full load Figure Input reflected ripple current full load Converter Module BC048A040T020FP vicorpower.com Rev. Page SPECIFICATIONS (CONT.) Output Specifications Parameter Output voltage Output power Rated current Peak repetitive power Current share accuracy Efficiency Half load Full load Internal output inductance Internal output capacitance Load capacitance Output overvoltage setpoint Output ripple voltage external bypass bypass capacitor Short circuit protection point Average short circuit current Effective switching frequency Line regulation Load regulation ROUT Transient response Voltage overshoot Response time Recovery time Output overshoot Input turn-on enable Output turn-on delay From application power From release 93.8 93.5 94.8 94.5 9,100 59.8 2.40 0.0825 0.77 2.55 1/12 2.70 0.0842 100% load step; Figures Figures Figures output filter; Figure output filter; Figure output filter; Figure output filter (Conditions Vin, full load, 25°C ambient unless otherwise specified) 3.17 2.99 4.58 4.42 Unit mVp-p mVp-p Note load Full load POUT pulse width 1ms, duty cycle 10%, baseline power Parallel Operation Page Figure Figure Effective value Figures Figure Module will shut down Fixed, phase VOUT load OUTPUT WAVEFORMS Efficiency Output Power Power Dissipation Power Dissipation Efficiency Output Power Output Power Figure Efficiency output power Converter Module BC048A040T020FP Figure Power dissipation function output power vicorpower.com Rev. Page SPECIFICATIONS (CONT.) OUTPUT WAVEFORMS Figure Output voltage ripple full load without external bypass capacitor. Figure Output voltage ripple full load with ceramic external bypass capacitor distribution inductance. Ripple Output Power Output Ripple (mVpk-pk) Output Power Figure Output voltage ripple output power without external bypass capacitor. Figure load step with input capacitor output capacitor. Figure load step with input capacitor output capacitor. Converter Module BC048A040T020FP vicorpower.com Rev. Page SPECIFICATIONS (CONT.) General Specifications Parameter MTBF MIL-HDBK-217F Isolation specifications Voltage Capacitance Resistance Agency approvals Mark RoHS Mechanical Weight Dimensions Length Width Height Thermal Over temperature shutdown Thermal capacity Baseplate ambient Baseplate ambient; 1000 Baseplate sink; flat greased surface Baseplate sink; thermal 23.8 0.40 0.36 Junction temperature 1.91/ 48,6 1.09/ 27,7 0.37/ Baseplate model Baseplate model Baseplate model 1.10/31,3 Mechanical Drawings, Figure 2,250 3,000 Input output Input output Input output /CSA 60950-1, 60950-1 voltage directive Mhrs 25°C, Unit Notes Auxiliary Pins Parameter Primary control (PC) voltage Module disable voltage Module enable voltage Current limit Enable delay time Disable delay time Figure time from output Source only Unit Notes Figure VOUT full load disable Converter Module BC048A040T020FP Figure signal during fault vicorpower.com Rev. Page CONTROL FUNCTIONS Voltage Input Ports BRICK (BCM) input voltage range should exceeded. internal under over voltage lockout function prevents operation outside normal operating input range. turns within input voltage window bounded "Input undervoltage turn-on" "Input overvoltage turn-off" levels, specified. protected against accidental application reverse input voltage addition rectifier series with positive input, reverse rectifier shunt with positive input located load side input fuse. connection power source should implemented with minimal distribution inductance. interconnect inductance exceeds input should bypassed with damper retain source impedance stable operation. With interconnect inductance damper series with single electrolytic equivalent low-Q capacitor used place series bypass. +Out -Out Voltage Output Ports sets contacts provided +Out port. They must connected parallel with interconnect resistance. Similarly, sets contacts provided -Out port. They must connected parallel with interconnect resistance. Within specified operating range, average output voltage defined Level behavioral model Figure current source capability rated specifications section this document. output impedance reduces eliminates need limited life aluminum electrolytic tantalum capacitors input converters. Total load capacitance output should exceed specified maximum. Owing wide bandwidth output impedance BCM, frequency bypass capacitance significant energy storage more densely efficiently provided adding capacitance input BCM. Primary Control Primary Control port multifunction node that provides following functions: Enable Disable port left floating, output enabled. Once this port pulled lower than with respect -In, output disabled. This action realized employing relay, opto-coupler, open collector transistor. Refer Figures 1-3, typical enable disable characteristics. This port should toggled rate higher than port should also driven pulled external voltage source. Primary Auxiliary Supply port source Vdc. port should never used sink current. Alarm contains circuitry that monitors output overload, input overvoltage undervoltage, internal junction temperatures. response abnormal condition monitored parameters, port will toggle. Refer Figure alarm characteristics. Reserved factory use. Figure BRICK configuration (viewed from side) Converter Module BC048A040T020FP vicorpower.com Rev. Page APPLICATION NOTES TEST CIRCUIT Parallel Operation will inherently current share when operated array. Arrays used higher power redundancy application. Current sharing accuracy maximized when source load impedance presented each within array equal. recommended method achieve matched impedances dedicate common copper planes within deliver return current array, rather than rely upon traces varying lengths. typical applications current being delivered load larger than that sourced from input, allowing traces utilized input side necessary. dedicated power planes however, preferable. power train control architecture allow bi-directional power transfer, including reverse power processing from output input. Reverse power transfer enabled input within operating range otherwise enabled. BCM's ability process power reverse improves transient response output load dump. Anomalies response source will appear output multiplied factor. resistance source should kept possible minimize voltage deviations. This especially important operated near high line over/under voltage detection circuitry could activated. Input Fuse Recommendations BRICKs internally fused order provide flexibility configuring power systems. However, input line fusing BRICKs must always incorporated within power system. fast acting fuse should placed series with port. agency approvals fusing conditions, click link below: Input Impedance Recommendations take full advantage capabilities, impedance presented input terminals must from approximately MHz. source should exhibit inductance (less than should have critically damped response. interconnect inductance exceeds input pins should bypassed with damper (e.g., series with retain source impedance stable operations. Given wide bandwidth BCM, source response generally limiting factor overall system response. Application Notes BRICK application notes soldering, board layout, system design please click link below: Applications Assistance Please contact Vicor Applications Engineering assistance, 1-800-927-9474, email apps@vicorpower.com. Fuse Input reflected ripple measurement point +OUT Enable/Disable Switch electrolytic -OUT +OUT Load -OUT Notes: Source inductance should more than source inductance greater than additional bypass capacitance required. should placed close load. separate damping resistor. power good indicator will when module fault detected. Input Fuse Recommendations section Figure BRICK test circuit Converter Module BC048A040T020FP vicorpower.com Rev. Page BEHAVIORAL MODELS BRICK Converter Level Behavioral Model IOUT ROUT 1/12 Iout 1/12 VOUT Figure This model characterizes operation BRICK converter, including converter transfer function losses. model enables estimates simulations output voltage function input voltage output load, well total converter power dissipation heat generation. BRICK Converter Level Transient Behavioral Model 0.23 IOUT ROUT Lout 1.11 RCIN 1/12 Iout 0.96 RCOUT 1/12 COUT VOUT Figure This model characterizes operation BRICK converter including response output load input voltage transients steady state modulations. model enables estimates simulations input output voltages under transient conditions, including response stepped load with without external filtering elements. Converter Module BC048A040T020FP vicorpower.com Rev. Page MECHANICAL DRAWINGS Baseplate Slotted Flange Heat Sink (Transverse) Figure Module outline Recommended Pattern (Component side shown) Figure mounting specifications Converter Module BC048A040T020FP vicorpower.com Rev. Page Warranty Vicor products guaranteed years from date shipment against defects material workmanship when normal service. This warranty does extend products subjected misuse, accident, improper application maintenance. Vicor shall liable collateral consequential damage. This warranty extended original purchaser only. EXCEPT FOREGOING EXPRESS WARRANTY, VICOR MAKES WARRANTY, EXPRESS IMPLIED, INCLUDING, LIMITED WARRANTY MERCHANTABILITY FITNESS PARTICULAR PURPOSE. Vicor will repair replace defective products accordance with best judgement. service under this warranty, buyer must contact Vicor obtain Return Material Authorization (RMA) number shipping instructions. Products returned without prior authorization will returned buyer. buyer will charges incurred returning product factory. Vicor will reshipment charges product defective within terms this warranty. Information published Vicor been carefully checked believed accurate; however, responsibility assumed inaccuracies. Vicor reserves right make changes products without further notice improve reliability, function, design. Vicor does assume liability arising application product circuit; neither does convey license under patent rights rights others. Vicor general policy does recommend components life support applications wherein failure malfunction directly threaten life injury. Vicor Terms Conditions Sale, user Vicor components life support applications assumes risks such indemnifies Vicor against damages. Vicor's comprehensive line power solutions includes high density AC-DC DC-DC modules accessory components, fully configurable AC-DC DC-DC power supplies, complete custom power systems. Information furnished Vicor believed accurate reliable. However, responsibility assumed Vicor use. Vicor components designed used applications, such life support systems, wherein failure malfunction could result injury death. sales subject Vicor's Terms Conditions Sale, which available upon request. Specifications subject change without notice. Intellectual Property Notice Vicor subsidiaries Intellectual Property (including issued U.S. Foreign Patents pending patent applications) relating products described this data sheet. Interested parties should contact Vicor's Intellectual Property Department. products described this data sheet protected following U.S. Patents Numbers: 5,945,130; 6,403,009; 6,710,257; 6,911,848; 6,930,893; 6,934,166; 6,940,013; 6,969,909; 7,038,917; 7,166,898; 7,187,263; 7,361,844; D496,906; D505,114; D506,438; D509,472; under 6,975,098 6,984,965 Vicor Corporation Frontage Road Andover, 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com Converter Module BC048A040T020FP vicorpower.com Rev. 3/08 Other recent searchesTD62107P - TD62107P TD62107P Datasheet TD62107BP - TD62107BP TD62107BP Datasheet TD62107F - TD62107F TD62107F Datasheet PCM1795 - PCM1795 PCM1795 Datasheet KD3002-DC72A - KD3002-DC72A KD3002-DC72A Datasheet ES350XSMD - ES350XSMD ES350XSMD Datasheet CY7B923 - CY7B923 CY7B923 Datasheet CY7B933 - CY7B933 CY7B933 Datasheet CD4094B - CD4094B CD4094B Datasheet AV902WP - AV902WP AV902WP Datasheet AT41470 - AT41470 AT41470 Datasheet
Privacy Policy | Disclaimer |