| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Option Optocouplers Safe Electrical Insulation 0884* These optoco
Top Searches for this datasheetOptocoupler Option Option Optocouplers Safe Electrical Insulation 0884* These optocouplers suitable safe electrical insulation only within safety maximum ratings. Compliance with safety maximum ratings must ensured protective circuits. partial discharge measurement ensures that partial discharge occurs during operation maximum permissible operating insulation voltage (VIORM). Permanent partial discharge affects insulating materials result high voltage breakdown. Time-Test Voltage Diagram 0884* recommended that tests with insulation test voltage (VISOL) should made, otherwise partial discharge occur impairing insulation characteristics. Thus partial discharges also occur maximum permissible operating insulation voltage. insulation test 0884 carried after other tests. INITIAL kV/us IORM IORM 0.1s 0.1s measuring time partial dischage measuring time partial dischage Procedure Type sampling tests, destructive tests 0884, edition June 1992 Procedure Routine tests, non-destructive tests Document Number: 82581 Revision 30-January-02 www.vishay.com 2-26 Description Symbol System DIP4 SFH610A-. SFH615A-. SFH615AA-. SFH615AGB-. SFH615AGR-. SFH617A-. SFH618A-. SFH620A-. SFH620AA-. SFH620AGB-. SFH628A-. SFH6106-. SFH6116-. SFH6156-. SFH6186-. SFH6206-. SFH6286-. DIP8 ILCT6 ILD1/2/5/74 ILD30/31/55 ILD32 ILD66-. ILD250/1/2 ILD255 ILD610-. ILD615-. ILD616-. ILD620-. ILD621GB-. ILD621-. ILD621GB-. ILD755-. ILD766-. MCT6 DIP16 ILQ1/2/5/74 ILQ30/31/55 ILQ32 ILQ66-. ILQ615-. ILQ620-. ILQ620GB-. ILQ621-. ILQ621GB-. Unit Installation Category (DIN 0110) Rated Line Voltages VRMS Rated Line Voltages VRMS Rated Line Voltages 1000 VRMS Climatic Category (DIN Part 1/9.80) Pollution Degree (DIN 0110 Part 1/1.89) Maximum Operation Insulating Voltage Test Voltage Input/Output, Procedure 1.875 VIORM, Routine Test, Partial Discharge Test Voltage Input/Output, Procedure VIORM, Type Sampling Test Partial Discharge VIORM 55/100/21 1669 1335 8000 8000 Maximum Permissible Overvoltage (Transient Overvoltage) VIOPartial Discharge Test Voltage VINITIAL Safety Maximum Ratings (Maximum Permissible Ratings Case Fault, also Refer Diagram) Package Temperature Current (Input Current 25°C) Derating with Higher Ambient Temp. Power (Output Total Power Dissipation, 25°C) Derating with Higher Ambient Temp. Insulation Resistance VI/O=500 -1.83 -2.67 mA/K mW/K Document Number: 82581 Revision 30-January-02 2-27 www.vishay.com Description Symbol System 4N25/26/27/28 4N35/36/37/38/39 4N32/33 CNY17-. CNY17F-. H11A-. H11AA1-. H11B-. H11B1-. H11C-. H11D-. IL1/2/5/74 IL2B-. IL30/31/55 IL55B-. IL66-. IL66B-. IL201/202/203 IL250 IL251 IL252 IL255-. IL400 IL755-. IL755B-. IL766-. IL766B-. MCA230/231 MCA255 MCT2/2E MCT270/271 MCT272 MCT273/274 MCT275 MCT276/277 MCT5210 MCT5211 SFH600-. SFH601-. SFH608-. SFH640-. MOC8050 IL56B-. MOC8021 MOC8112 MOC8102/ 03/04/05 Unit Installation Category (DIN 0110) Rated Line Voltages VRMS Rated Line Voltages VRMS Rated Line Voltages 1000 VRMS Climatic Category (DIN Part 1/9.80) Pollution Degree (DIN 0110 Part 1/1.89) Maximum Operation Insulating Voltage Test Voltage Input/Output, Procedure 1.875 VIORM, Routine Test, Partial Discharge Test Voltage Input/Output, Procedure VIORM, Type Sampling Test Partial Discharge Partial Discharge Test Voltage Safety Maximum Ratings (Maximum Permissible Ratings Case Fault, also Refer Diagram) Package Temperature Current (Input Current 25°C) Derating with Higher Ambient Temp. Power (Output Total Power Dissipation, 25°C) Derating with Higher Ambient Temp. Insulation Resistance VI/O=500 VIORM I-IV I-IV I-III 55/100/21 1669 1335 8000 8000 Maximum Permissible Overvoltage (Transient Overvoltage) VIOVINITIAL -2.67 -4.67 mA/K mW/K Document Number: 82581 Revision 30-January-02 2-28 www.vishay.com Description Symbol System IL410 IL420 IL4116 IL4117 IL4118 IL4216 IL4217 IL4218 System 6N135 6N136 SFH6135 SFH6136 6N138 SFH6138 SFH6139 6N139 SFH6345 System IL300 IL300E IL300F IL300EF IL300DEFG Unit Installation Category (DIN 0110) Rated Line Voltages VRMS Rated Line Voltages VRMS Rated Line Voltages 1000 VRMS Climatic Category (DIN Part 1/9.80) Pollution Degree (DIN 0110 Part 1/1.89) Maximum Operation Insulating Voltage Test Voltage Input/Output, Procedure 1.875 VIORM, Routine Test, Partial Discharge Test Voltage Input/Output, Procedure VIORM, Type Sampling Test Partial Discharge Partial Discharge Test Voltage Safety Maximum Ratings (Maximum Permissible Ratings Case Fault, also Refer Diagram) Package Temperature Current (Input Current 25°C) Derating with Higher Ambient Temp. Power (Output Total Power Dissipation, 25°C) Derating with Higher Ambient Temp. Insulation Resistance VI/O=500 Description VIORM I-IV I-III I-II 55/100/21 1594 I-IV I-IV I-III 55/100/21 1181 I-IV I-IV I-III 55/100/21 1669 1275 6000 6000 8000 8000 1335 8000 8000 Maximum Permissible Overvoltage (Transient Overvoltage) VIOVINITIAL Symbol -1.65 -3.33 System LH1262 LH1485 LH1500 LH1502 4)5) -3.33 -1.57 -3.1 mA/K mW/K Unit LH1513 LH1514 LH1518 LH1521 LH1531 LH1532 LH1533 LH1535 LH1537 LH1540 LH1541 LH1544 LH1546 LH1547 LH1550 AACTR-X017 AAC-X001 www.vishay.com LH1501 LH1520 LH1503 LH1504 LH1505 LH1511 LH1522 LH1523 LH1525 LH1527 AT-X016 AAB-X017 LH1510 LH1526 3)4) LH1512 AT-X001 AT1-X001 Document Number: 82581 Revision 30-January-02 2-29 LH1530 Description Symbol System AB-X001 BB-X001 CB-X001 AABTR-X017 AAB-X001 AABTR-X001 AT1-X016 AAB1-X016 AAB1-X017 AAB1TR-X017 AAB1-X001 AAB1TR-X001 AB-X016 AAC-X017 AACTR-X001 BB-X016 BAC-X017 BACTR-X017 BAC-X001 BACTR-X001 CB-X016 CAC-X017 CACTR-X017 CAC-X001 CACTR-X001 Unit Installation Category (DIN 0110) Rated Line Voltages VRMS Rated Line Voltages VRMS Rated Line Voltages 1000 VRMS Climatic Category (DIN Part 1/9.80) Pollution Degree (DIN 0110 Part 1/1.89) Maximum Operation Insulating Voltage Test Voltage Input/Output, Procedure 1.875 VIORM, Routine Test, Partial Discharge Test Voltage Input/Output, Procedure VIORM, Type Sampling Test Partial Discharge VIORM I-IV I-IV I-III 40/85/21 1669 I-IV I-IV I-III 40/85/21 1130 2119 1335 8000 8000 1695 8000 8000 Maximum Permissible Overvoltage (Transient Overvoltage) VIOPartial Discharge Test Voltage VINITIAL Safety Maximum Ratings (Maximum Permissible Ratings Case Fault, also Refer Diagram) Package Temperature Current (Input Current 25°C) Derating with Higher Ambient Temp. Power (Output Total Power Dissipation, 25°C) Derating with Higher Ambient Temp. Insulation Resistance VI/O=500 -4.67 -4.67 mA/K mW/K voltages referred peak values except otherwise specified. time-test voltage diagram preparation Testing input/output voltage requires input pins output pins shorted. Option Tested 0884 Option Wide lead spacing (10.16 creepage/clearance distances Option Surface mount leads (creepage/clearance distances Option Surface mount leads CECC 00802, edition soldering conditions devices (option "-." means dash selections. Document Number: 82581 Revision 30-January-02 2-30 www.vishay.com Option High-Rel Optocoupler With Very High Long-Term Stability Coupling Factor (CTR) Each optocoupler tested degradation characteristics (change current transfer ratio). degradation behavior optocouplers tested during short burn-in provides information long-term stability. Only optocouplers showing minimum change current transfer ratio during burn-in supplied. These optocouplers feature excellent long-term stability. Test procedure: First data logging coupling factor (CTRl) IF=1 VCE=5 logged. Load Short-time burn-in: emitter loaded with forward current lF=150 room temperature (25°C) minutes. Second data logging coupling factor (CTR2) IF=1 VCE=5 logged. Evaluation Determination relative change coupling factor: DCTR (%)=100 (1-CTR2/CTRl) change coupling factor DCTR caused burn-in greater than defined range. Thus high longterm stability coupling factor shown graph specified. couplers show similar degradation behavior meaning that even after longer operating time coupling factor spread very wide. 1431 Years Years IF=1mA Years 60mA 300mA Service life relative temperature current-load Average expected service life extrapolated from laboratory tests. service life defined time when falls initial value. Confidence level 90%. Document Number: 82581 Revision 30-January-02 2-31 www.vishay.com Option Optocouplers with 0.4" (10.16 Lead Spread. leads optocouplers bent according spacing 0.4" (10.16 mm). Dimensions deviating from standard type are: Lead spacing Creepage distance Clearance 10.16 (0.4") >8.0 >8.0 .407 (10.36) .391 (9.96) .307 (7.8) .291 (7.4) .255 (6.5) .248 (6.3) This version additionally complies with following standards: 0805/05 (System only) Reinforced insulation operating voltage VRMS .014 (0.35) .010 (0.25) .400 (10.16) .430 (10.92) Clearance-creepage distance=8.0 standard version configuration Option Lead Bends Surface Mount Optocouplers These optocouplers suitable surface mounting. Dimensions deviating from standard type are: Creepage distance Clearance >8.0 >8.0 .028 (0.7) MIN. .300 (7.62) TYP. .255 (6.5) .248 (6.3) .180 (4.6) .160 (4.1) .020 (0.5) .020 (0.5) .040 (1.02) This version additionally complies with following standards: 0805/05 (System only) Reinforced insulation operating voltage VRMS During soldering process, package should wetted with tin-lead solder prevent impairment isolation features. Apart from iron soldering, only reflow soldering methods (vapor phase, infrared gas) permissible. Permissible soldering conditions: 260°C seconds 215°C seconds soldering process repeated times most. Attention must paid cooling down device 25°C between soldering processes. .315 (8.0) MIN. .331 (8.4) MIN. .406 (10.3) MAX. .300 (7.62) TYP. .268 (6.81) .255 (6.48) .150 (3.81) .130 (3.30) 4/8/16 .020 (0.50) .000 (0.00) .016(0.4) typ. .365 (9.27) MIN. .472 (12.00) MAX. .015 (0.38) typ. .031 (0.79)typ. .050(1.27) typ. Clearance creepage distances must considered solder design. Clearance-creepage distance=8.0 min. standard version configuration. Document Number: 82581 Revision 30-January-02 2-32 www.vishay.com Option Lead Bends Surface Mount Optocouplers These optocouplers suitable surface mounting. Dimensions deviating from standard type are: Creepage distance Clearance >8.0 >8.0 This version additionally complies with following standards: 0805/05 (System only) Reinforced insulation operating voltage VRMS During soldering process, package should wetted with tin-lead solder prevent impairment isolation features. Apart from iron soldering, only reflow soldering methods (vapor phase, infrared gas) permissible. Permissible soldering conditions: 260°C seconds 215°C seconds soldering process repeated times most. Attention must paid cooling down device 25°C between soldering processes. .300 (7.62) TYP. .255 (6.5) .248 (6.3) .020 (0.50) .000 (0.00) .150 (3.81) .130 (3.30) .020 (0.5) .020 (0.5) .040 (1.02) .365 (9.27) MIN. .472 (12.00) MAX. .300 (7.62) TYP. .268 (6.81) .255 (6.48) .020 (0.50) .000 (0.00) .150 (3.81) .130 (3.30) .015 (0.38) typ. .016(0.4) typ. .031 (0.79)typ. .050(1.27) typ. .365 (9.27) MIN. .472 (12.00) MAX. Clearance creepage distances must considered solder design. Clearance-creepage distance=8.0 min. standard version configuration. Document Number: 82581 Revision 30-January-02 2-33 www.vishay.com Option Lead Bends Surface Mount Optocouplers During soldering process, package should wetted with tin-lead solder prevent impairment isolation features. Apart from iron soldering, only reflow soldering methods (vapor phase, infrared gas) permissible. Permissible soldering conditions: 260°C seconds 215°C seconds soldering process repeated times most. Attention must paid cooling down device 25°C between soldering processes. .015 (0.38) typ. .375 (9.53) .395 (10.03) .300 (7.62) ref. .0040 (.102) .0098 (.249) .012 (.30) typ. .020 (.51) .040 (1.02) max. .016(0.4) typ. .031 (0.79)typ. .050(1.27) typ. 4/8/16 .020 (0.5) .020 (0.5) .040 (1.02) Document Number: 82581 Revision 30-January-02 2-34 www.vishay.com Legal Disclaimer Notice Vishay Disclaimer product specifications data subject change without notice. Vishay Intertechnology, Inc., affiliates, agents, employees, persons acting their behalf (collectively, "Vishay"), disclaim liability errors, inaccuracies incompleteness contained herein other disclosure relating product. Vishay disclaims liability arising application product described herein information provided herein maximum extent permitted law. product specifications expand otherwise modify Vishay's terms conditions purchase, including limited warranty expressed therein, which apply these products. license, express implied, estoppel otherwise, intellectual property rights granted this document conduct Vishay. products shown herein designed medical, life-saving, life-sustaining applications unless otherwise expressly indicated. Customers using selling Vishay products expressly indicated such applications entirely their risk agree fully indemnify Vishay damages arising resulting from such sale. Please contact authorized Vishay personnel obtain written terms conditions regarding products designed such applications. Product names markings noted herein trademarks their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com Other recent searchesTCC3100 - TCC3100 TCC3100 Datasheet STPS3L40S - STPS3L40S STPS3L40S Datasheet LCM0207SI - LCM0207SI LCM0207SI Datasheet GLC50 - GLC50 GLC50 Datasheet CSA22 - CSA22 CSA22 Datasheet EM78M680 - EM78M680 EM78M680 Datasheet EFC240B-180F - EFC240B-180F EFC240B-180F Datasheet DEA202450BT-7171A1 - DEA202450BT-7171A1 DEA202450BT-7171A1 Datasheet 1N3154-1 - 1N3154-1 1N3154-1 Datasheet 1N3157-1 - 1N3157-1 1N3157-1 Datasheet
Privacy Policy | Disclaimer |