APPLICATIONS On-Resistance (0.5 ohms MAX) Continuous Load Current


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



M281 bi-directional, single-pole, single-throw, normally open solid-state relay miniature 4-pin small outline package. This device offers very on-resistance-allowing high load current rating miniature package, ideal higher power applications where board space limited.
APPLICATIONS
On-Resistance (0.5 ohms MAX) Continuous Load Current load voltage rating input control current (3mA TYP) Miniature package High input-to-output isolation (1.5kV MIN)
Automated Test Equipment Meter reading systems Medical equipment Battery Monitoring Multiplexers
OPTIONS/SUFFIXES*
ABSOLUTE MAXIMUM RATINGS*
PARAMETER Storage Temperature Operating Temperature UNIT
Tape Reel Option (2,000 reel)
NOTE: Suffixes listed above included marking device part number identification.
SCHEMATIC DIAGRAM
Continuous Forward Current Peak Forward Current (1us) Reverse Input Control Voltage Output Power Dissipation
*The values indicated absolute stress ratings. Functional operation device implied these conditions excess those defined electrical characteristics section this document. Exposure Absolute Ratings cause permanent damage device adversely affect reliability.
APPROVALS
C-UL Approved (File E201932)
2009 Solid State Optronics www.ssousa.com +1.408.293.4600
Page
M281 1.41 (04/03/2009)
Form Solid State Relay
ELECTRICAL CHARACTERISTICS 25°C
PARAMETER INPUT SPECIFICATIONS
Forward Voltage Reverse Voltage Turn-on Current Turn-On Current Turn-off Current 10mA 10uA 10mA, 20ms 100mA
UNIT
TEST CONDITIONS
OUTPUT SPECIFICATIONS
Blocking Voltage Continuous Load Currente On-Resistance Leakage Current Output Capacitance Offset Voltage 1000 1000mA 25V, 1.0MHz
COUPLED SPECIFICATIONS
Isolation Voltage Turn-on Time Turn-off Time Isolation Resistance Coupled Capacitance Contact Transient Ratio 2000 7000 1500 minute 5mA, 1000mA 0mA, 100mA,
2009 Solid State Optronics www.ssousa.com +1.408.293.4600
Page
M281 1.41 (04/03/2009)
Form Solid State Relay
PERFORMANCE DATA
M281 Typical Turn-On Time Distribution 100, Ambient Temperature 25°C
M281 Typical Turn-Off Time Distribution 100, Ambient Temperature 25°C
Device Count
Device Count
Turn-On
0.15 0.25 0.35 0.45 Turn-Off
Typical On-Resistance Distribution 100, Ambient Temperature 25°C
M281 Typical Leakage Current Distribution 100, Ambient Temperature 25°C
Device Count 0.35 0.45 0.55 0.65 On-Resistance (ohm
Device Count
Leakage Current (uA)
Typical Blocking Voltage Distribution 100, Ambient Temperature 25°C
M281 Maximum Load Current Temperature
Blocking Voltage
Load Current (mA)
Device Count
1200 1000
perature
2009 Solid State Optronics www.ssousa.com +1.408.293.4600
Page
M281 1.41 (04/03/2009)
Form Solid State Relay
MECHANICAL DIMENSIONS SMALL OUTLINE PACKAGE
VIEW
VIEW
BACK VIEW
2009 Solid State Optronics www.ssousa.com +1.408.293.4600
Page
M281 1.41 (04/03/2009)
Form Solid State Relay
DISCLAIMER
Solid State Optronics (SSO) makes warranties representations with regards completeness accuracy this document. reserves right make changes product description, specifications time without further notice. shall assume liability arising application product circuit described herein. Neither circuit patent licenses indemnity expressed implied. Except specified SSO's Standard Terms Conditions, disclaims liability consequential other damage, make other warranty, expressed implied, including merchantability fitness particular use.
LIFE SUPPORT POLICY
does authorize devices life support applications wherein failure malfunction device lead personal injury death. Users devices life support applications assume risks such agree indemnify against damages resulting from such use. Life support devices defined devices systems which, intended surgical implant into body, support sustain life, whose failure perform when used properly accordance with instructions reasonably expected result significant injury user, critical component component life support device system whose failure reasonably expected cause failure life support device system, affect safety effectiveness.
2009 Solid State Optronics www.ssousa.com +1.408.293.4600
Page
M281 1.41 (04/03/2009)

Other recent searches


TMS320VC5503 - TMS320VC5503   TMS320VC5503 Datasheet
TISP83121D - TISP83121D   TISP83121D Datasheet
SNC521 - SNC521   SNC521 Datasheet
PZ5064C - PZ5064C   PZ5064C Datasheet
PZ5064N - PZ5064N   PZ5064N Datasheet
MJF18008 - MJF18008   MJF18008 Datasheet
IRFR - IRFR   IRFR Datasheet
U3303 - U3303   U3303 Datasheet
A6810 - A6810   A6810 Datasheet
74LVQ373 - 74LVQ373   74LVQ373 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive