| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
3-channel Video Buffer with Built-in wideband SM5308BS 3-channel
Top Searches for this datasheetSM5308BS 3-channel Video Buffer with Built-in wideband SM5308BS 3-channel video buffer with built-in 5th-order lowpass filters. lowpass filter cutoff frequency range adjust from 5.0MHz 44MHz*1 steps. lowpass filter supports 480i 1080i format, video signal equipment analog input/outputs. video input systems, device functions next-stage system anti-aliasing filter. video output systems, filter reduces video aliasing external noise drive terminating resistance. cutoff frequency, signal input type, output gain switching controlled using I2C-BUS*2, slave address (3-state input) allow three SM5308BS same bus. When resistor connected ISET (RISET) 1.8k. I2C-BUS registered trademark B.V. FEATURES PINOUT (Top view) REF1 TEST REF2 REF3 VCC1 OUT1A OUT1B GND1 VCC2 Supply voltages Analog: 4.75 5.25V Digital: 5.5V Lowpass filter with adjustable cutoff frequency (256 steps) Cutoff frequency range: 5.0MHz 44MHz (RISET 1.8k) Filter bypass mode function display specifications SXGA resolution Passband: 65MHz (typ) Half mode switch function (CH-2, CH-3) suitable component signals Video input pins independently synctip clamp/bias inputs terminating resistance drive capability Output gain switching: 6.5dB/12.5dB Disable function 300µA current consumption when disabled Output compensation circuit built-in I2C-BUS interface control Slave address: 90h, 92h, three devices used simultaneously, selected input) Data transfer rate: Fast mode 400kbit/s) Operating ambient temperature range: 70°C Package: 28-pin HSOP ISET OUT2A OUT2B GND2 VCC3 OUT3A OUT3B GND3 PACKAGE DIMENSIONS (Unit: 0.15 APPLICATIONS HDTVs PDPs Projectors 1.3TYP 18.6 5.15 ORDERING INFORMATION Device SM5308BS Package 28-pin HSOP 0.10 0.35 0.05 0.12 SEIKO CORPORATION 0.05 SM5308BS BLOCK DIAGRAM ISET REF1 Control Vref Current Source REF2 REF3 Bypass Clamp/Bias CH-1 order (Standard 6.5dB /12.5dB VCC1 OUT1A Filter OUT1B GND1 Bypass Clamp/Bias CH-2 order (Standard /Half 6.5dB /12.5dB VCC2 OUT2A Filter OUT2B GND2 Bypass Clamp/Bias CH-3 order (Standard /Half 6.5dB /12.5dB VCC3 OUT3A Filter OUT3B GND3 Note. recommended value external resistor (RISET) connected ISET 1.8k. SEIKO CORPORATION SM5308BS DESCRIPTION Number input, output analog, digital Name REF1 TEST ISET GND3 OUT3B OUT3A VCC3 GND2 OUT2B OUT2A VCC2 GND1 OUT1B OUT1A VCC1 REF3 REF2 I/O*1 A/D*2 Internal reference voltage Digital supply data signal input/output clock signal input Digital ground Test (connect ground) slave address select (3-state input) Video signal input (CH-1 input) connection Internal current-setting resistor (RISET) connection (standard 1.8k) Video signal input (CH-2 input) connection Video signal input (CH-3 input) connection Analog ground (CH-3) Video signal output (CH-3, compensation) Video signal output (CH-3) Analog supply (CH-3) Analog ground (CH-2) Video signal output (CH-2, compensation) Video signal output (CH-2) Analog supply (CH-2) Analog ground (CH-1, Vref) Video signal output (CH-1, compensation) Video signal output (CH-1) Analog supply (CH-1, Vref) Internal reference voltage Internal reference voltage Description SEIKO CORPORATION SM5308BS EQUIVALENT CIRCUITS Number Name I/O*1 Equivalent circuit VCCn INnA GNDn VCCn OUTnA OUT1A OUT1B OUT2A OUT2B OUT3A OUT3B GNDn VCCn OUTnB GNDn VCC1 REF1 REF1 GND1 VCC1 REF2 REF2 GND1 SEIKO CORPORATION SM5308BS Number Name I/O*1 Equivalent circuit VCC1 REF3 REF3 GND1 input, output Note. Resistance values equivalent circuits indicate design values. SEIKO CORPORATION SM5308BS SPECIFICATIONS Absolute Maximum Ratings GND1 GND2 GND3 VCC1 VCC2 VCC3 Parameter Supply voltage Input voltage Storage temperature range Power dissipation Junction temperature Symbol TSTG 60°C/W Note. measured quantity under mounted condition which specified. Condition VCC1, VCC2, VCC3, ADS, SDA, SCL, Rating Unit Recommended Operating Conditions Parameter Supply voltage Supply voltage difference Supply voltage Operating ambient temperature Symbol Condition VCC1, VCC2, VCC3 VCC1 VCC2, VCC1 VCC3, VCC2 VCC3 Rating 4.75 5.25 Unit Note. VCC1 VCC3 should applied simultaneously. Electrical Characteristics Characteristics 5.0V, 5.5V, 25°C, 100kHz, 0.5Vp-p, RISET 1.8k, CH-1 clamp input, CH-2 CH-3 bias input, FCDATA 227, unless otherwise noted. Rating Parameter Current consumption Current consumption Current consumption Current consumption HIGH-level input voltage LOW-level Input voltage HIGH-level input voltage LOW-level input voltage open-circuit input voltage LOW-level input leakage current HIGH-level input leakage current output voltage Symbol ICC1 ICC2 ICC3 ICC4 VIH1 VIL1 VIH2 VIL2 VOPEN Condition Filter mode, FCDATA Filter bypass mode Power-down mode, 3-address mode Power-down mode, 2-address mode SDA, SDA, SDA, SCL, SDA, SCL, output, Sink current VDD/2 VDD/2 Unit Test level Total current consumption VCC1, VCC2, VCC3, VDD, when input signals. SEIKO CORPORATION SM5308BS Characteristics (I2C-BUS) 5.0V, 5.5V, 25°C, unless otherwise noted. Rating Parameter clock frequency hold time (start condition) clock LOW-level pulsewidth clock HIGH-level pulsewidth setup time (start condition) data hold time data setup time SDA, rise time SDA, fall time setup time (stop condition) SDA, input capacitance Symbol fSCL tHD;STA tLOW tHIGH tSU;STA tHD;DAT tSU;DAT tSU;STO Condition Unit Test level tLOW tSU;DAT tHD;STA tHD;STA tHD;DAT tHIGH tSU;STA tSU;STO Note. start condition, stop condition SEIKO CORPORATION SM5308BS Analog Characteristics Analog input characteristics 5.0V, 5.5V, 25°C, 100kHz, 0.5Vp-p, RISET 1.8k, CH-1 clamp input, CH-2 CH-3 bias input, FCDATA 227, unless otherwise noted. Internal mode settings shown table "Mode Condition Settings". Rating Parameter Clamp voltage Bias voltage Input resistance Symbol VCLMP VBIAS RBIAS VAI1 Filter mode maximum input voltage VAI2 VAI3 VAI4 VAI5 Bypass mode maximum input voltage VAI6 VAI7 VAI8 Clamp input Bias input Bias input Mode: (bias, 6.5dB), 1.0% Mode: (bias, 12.5dB), 1.0% Mode: (clamp, 6.5dB), 1.5% Mode: (clamp, 12.5dB), 1.5% Mode: (bias, 6.5dB), 1.0% Mode: (bias, 12.5dB), 1.5% Mode: (clamp, 6.5dB), 1.5% Mode: (clamp, 12.5dB), 3.0% Condition 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 Vp-p Vp-p Vp-p Vp-p Vp-p Vp-p Vp-p Vp-p Unit Test level Note. This item represents values maximum input signal amplitude which output distortion rate shown condition column filled. When signal amplitude that exceeds this specification value input, output distortion rate deteriorated. When using this device, input signal level should exceed standard value (min) signal amplitude. Filter mode bypass mode frequency characteristics 5.0V, 5.5V, 25°C, 100kHz, 0.5Vp-p, RISET 1.8k, CH-1 clamp input, CH-2 CH-3 bias input, FCDATA 227, unless otherwise noted. Rating Parameter Symbol Cutoff frequency Half mode cutoff frequency ratio attenuation Filter bypass mode passband Rhalf1 Rhalf2 FCDATA FCDATA FCDATA FCDATA Half mode, FCDATA Half mode, FCDATA 4fc, attenuation from 100kHz 0.5Vp-p, Gain Condition 5.95 32.57 5.00 6.76 37.01 44.42 7.57 41.45 Unit Test level SEIKO CORPORATION SM5308BS Analog output characteristics 5.0V, 5.5V, 25°C, 100kHz, 0.5Vp-p, RISET 1.8k, CH-1 clamp input, CH-2 CH-3 bias input, FCDATA 227, unless otherwise noted. Internal mode settings shown table "Mode Condition Settings". Rating Parameter Symbol AVF1 AVF2 Filter bypass mode output gain AVB1 AVB2 Filter bypass mode gain error Channel channel gain error Maximum output voltage dAVBP dAVCH Vout1 Vout2 THDB1 Output distortion THDB2 THDC1 THDC2 Channel channel crosstalk Drive load resistance response time XTLK1 Mode: (6.5dB), 1.5% Mode: b12, (12.5dB), 1.5% Mode: 1kHz, 0.55Vp-p Mode: b12, 1kHz, 0.55Vp-p Mode: 1kHz, 0.55Vp-p Mode: c12, 1kHz, 0.55Vp-p 0.5Vp-p input, 1MHz, between channels load Response time from output when changing settings using I2C-BUS Gain 6.5dB Gain 12.5dB Gain 6.5dB Gain 12.5dB Gain error between filter mode bypass mode Condition 12.0 12.0 1.15 Filter mode output gain 12.5 12.5 13.0 13.0 Vp-p Vp-p load Unit Test level Reference voltage characteristics 5.0V, 5.5V, 25°C, unless otherwise noted. Rating Parameter Symbol output voltage REF1 REF2 REF3 Condition 2.15 2.60 3.40 Unit Test level Test level definition "Test Level" shown electrical characteristic table follows. 100% products tested 25°C. Guaranteed result design characteristics evaluation. SEIKO CORPORATION SM5308BS Mode Condition Settings Table Mode settings Input type Mode setting CH-1 Clamp Bias Clamp Bias Clamp Bias Clamp 12.5dB 12.5dB 6.5dB Bypass 12.5dB 6.5dB 12.5dB Half 6.5dB 12.5dB 6.5dB 12.5dB 6.5dB Filter Bias Bias 12.5dB 6.5dB Standard CH-2 CH-3 6.5dB Output gain mode Filter/Bypass mode SEIKO CORPORATION SM5308BS Evaluation Circuit Diagram Controller 0.1µF 100µF 10µF REF1 TEST 10µF 10µF REF2 REF3 VCC1 100µF OUT1 OUT1A OUT1B GND1 VCC2 22µF 4.7µF 100µF OUT2A OUT2B GND2 VCC3 OUT3A OUT3B GND3 100µF OUT2 22µF 4.7µF ISET RISET 1.8k OUT3 4.7µF 22µF Note. This electrical characteristics evaluation circuit only, then recommended application circuit. TEST should connected GND. SEIKO CORPORATION SM5308BS FUNCTIONAL DESCRIPTION I2C-BUS Control SM5308BS uses interface following functions. Cutoff frequency Output gain mode switching (1/2 cutoff frequency switching) Filter mode/filter bypass mode switching Input type switching (sync-tip clamp, bias) Disable function Maximum number slave addresses transfer rate I2C-BUS corresponds fast-mode 400kbit/s). Note that SM5308BS does support read function write only). Basic cycle Start condition Stop condition I2C-BUS start/stop condition basic access cycle comprises following elements. Start condition byte: Slave address byte: Subaddress byte: Control data Stop condition input data does match slave address subaddress incorrect, corresponding (acknowledge) output LOW. However, output after byte irrespective byte data. Also note that does support subaddress auto-increment function, hence each subaddress access requires basic cycle steps Start byte:Slave address byte:Subaddress byte:Control data Stop SEIKO CORPORATION SM5308BS byte: slave address three slave addresses. Note that must (Write)". byte: slave address Open*1 When open (94h), I2C-BUS control able address. "P16. Maximum number slave addresses". byte: subaddress byte sets subaddress, selecting three registers. byte: subaddress Register name FCSET CONDITION1 CONDITION2 byte: control data byte control data sets register flags corresponding subaddress selected byte. flags assigned shown following table. byte: control data Register name FCSET CONDITION1 CONDITION2 HALF BYPASS SEIKO CORPORATION SM5308BS Flag settings Cutoff frequency Register name: FCSET Flag names: FCM, [6:0] FCSET register setting sets cutoff frequency using tuning adjustment functions, thus total steps possible. Flag name FCDATA FCSET 44.01 44.21 44.42 23.38 23.50 23.62 10.26 10.61 10.96 Cutoff frequency [MHz] 5.00 5.18 5.35 Default Input type switching (sync-tip clamp, bias) Register name: CONDITION1 Flag names: [5:4], [3:2], [1:0] These flags input type CH-1, CH-2, CH-3 types: sync-tip clamp input, bias input. Channel CH-1 CH-2 CH-3 Flag name Don't care Input type Default Sync-tip clamp input Bias input Invalid SEIKO CORPORATION SM5308BS Output gain Register name: CONDITION1 Flag name: Flag name Output gain 6.5dB 12.5dB Default Disable mode select Register name: CONDITION2 Flag name: This flag enables/disables analog block. When analog block disabled, output pins high impedance. Flag name Mode Enable (normal operation) Disable operation) Default mode switching (1/2 cutoff frequency switching) Register name: CONDITION2 Flag name: HALF This flag switches cutoff frequency CH-2 CH-3 divide value FCSET register into halves. Note that CH-1 cutoff frequency cannot switched 1/2. This mode suitable systems where sampling frequency varies requirements, such component signals. Flag name mode HALF Standard mode (CH-1, CH-2, CH-3 cutoff frequency identical) Half mode (CH-2, CH-3 cutoff frequency that CH-1) Default Filter bypass mode Register name: CONDITION2 Flag name: BYPASS This flag allows internal lowpass filter SM5308BS bypassed. output gain switched, even filter bypass mode. input type output gain just filter mode. However, cutoff frequency mode settings have effect outputs. Flag name Filter BYPASS Filter mode (signals pass through lowpass filter) Filter bypass mode (signals bypass lowpass filter) Default SEIKO CORPORATION SM5308BS Maximum number slave addresses Register name: CONDITION2 Flag name: flag sets maximum number slave address selected input pins either setting resistor. input equivalent circuit shown below. When LOW, switches SW31 SW33 input levels (LOW HIGH) valid. When HIGH, switches SW31 SW33 input levels (LOW, HIGH, Open) valid. this time, current consumption increases several hundreds compared setting. Note.The default value plug HIGH address). once address) device addressed setting when Open, that device subsequently longer accessible until power supply turns OFF. Flag name Maximum number slave address (2-address mode) (3-address mode) Default setting HIGH Open HIGH Open Slave address 1001000 1001001 Invalid 1001000 1001001 1001010 current flow NCA=2 SW21 Control NCA=L(2) Address decoder NCA=H(3) SW31 SW32 SW33 NCA=3 SEIKO CORPORATION SM5308BS Lowpass Filter SM5308BS built-in 5th-order lowpass filters with variable cutoff frequency. cutoff frequency range resistor (RISET) connected between ISET GND, cutoff frequency setting determined FCDATA data. cutoff frequency FCDATA values listed table shown graphically figure Table Cutoff frequency FCDATA (RISET 1.8k) FCDATA FCSET (hex) Cutoff freq. [MHz] 5.00 5.18 5.35 5.53 5.70 5.88 6.05 6.23 6.40 6.58 6.76 6.93 7.11 7.27 7.44 7.60 7.77 7.93 8.10 8.26 8.43 8.59 8.75 8.90 9.06 9.21 9.37 9.52 9.68 9.83 9.99 10.14 10.30 10.45 10.61 10.76 10.92 11.07 11.23 11.38 11.54 11.69 11.85 12.00 12.16 12.31 12.47 12.62 12.78 12.93 13.09 13.24 13.40 13.55 13.71 13.86 14.02 14.17 14.32 14.46 14.61 14.75 14.90 15.04 FCDATA FCSET (hex) Cutoff freq. [MHz] 15.19 15.33 15.47 15.62 15.76 15.91 16.05 16.20 16.34 16.49 16.63 16.78 16.91 17.04 17.18 17.31 17.45 17.58 17.72 17.85 17.98 18.12 18.25 18.39 18.52 18.66 18.79 18.92 19.06 19.19 19.33 19.46 19.60 19.73 19.86 20.00 20.13 20.27 20.40 20.54 20.67 20.80 20.94 21.07 21.21 21.34 21.48 21.61 21.74 21.88 22.01 22.14 22.26 22.39 22.51 22.63 22.76 22.88 23.00 23.13 23.25 23.38 23.50 23.62 FCDATA FCSET (hex) Cutoff freq. [MHz] 10.26 10.60 10.94 11.28 11.62 11.96 12.30 12.64 12.98 13.31 13.64 13.97 14.30 14.63 14.96 15.29 15.62 15.95 16.27 16.59 16.91 17.23 17.55 17.86 18.17 18.48 18.79 19.10 19.40 19.70 20.00 20.30 20.60 20.89 21.18 21.47 21.76 22.05 22.33 22.61 22.89 23.17 23.45 23.72 23.99 24.26 24.53 24.80 25.07 25.33 25.59 25.85 26.11 26.36 26.61 26.86 27.11 27.36 27.61 27.86 28.11 28.36 28.61 28.86 FCDATA FCSET (hex) Cutoff freq. [MHz] 29.11 29.35 29.59 29.83 30.07 30.31 30.55 30.79 31.03 31.26 31.49 31.72 31.95 32.18 32.41 32.64 32.87 33.10 33.33 33.56 33.78 34.00 34.22 34.44 34.66 34.88 35.10 35.32 35.54 35.75 35.96 36.17 36.38 36.59 36.80 37.01 37.28 37.55 37.82 38.09 38.36 38.63 38.90 39.17 39.44 39.71 39.98 40.25 40.52 40.78 41.04 41.30 41.56 41.82 42.08 42.34 42.60 42.86 43.12 43.38 43.64 43.90 44.16 44.42 SEIKO CORPORATION SM5308BS FCDATA Figure Cutoff frequency FCDATA (RISET 1.8k) RISET RISET controls internal current source, connection essential. recommended value (RISET) 1.8k. disable mode filter bypass mode, ISET high impedance, current flows into RISET. Note. value other than 1.8k will change current consumption SM5308BS. determination resistance value, caution should taken ensure power dissipation does exceed absolute maximum rating package. Half Mode half mode, CH-2 CH-3 cutoff frequency that CH-1 cutoff frequency setting. Half mode useful systems where sampling frequency varies luminance color difference signal (Cr, requirements component signals. Group Delay Characteristics group delay varies with cutoff frequency setting, shown figure Note also that half mode, group delay between CH-1 CH-2/CH-3 varies. FCDATA HALF High RISET 1.8k [MHz] FCDATA Group delay [ns] Ratio FCDATA Frequency [MHz] ratio (CH-2/CH-1, CH-3/CH1) Figure Cutoff frequency ratio (half mode) Figure Group delay characteristics SEIKO CORPORATION SM5308BS Filter Bypass Mode filter bypass mode, internal lowpass filter SM5308BS bypassed signal input output buffer stage directly. filter bypass mode, input type, multiplexer function, output gain just filter mode. cutoff frequency setting mode setting have effect outputs. this mode, passband frequency 65MHz (typ), which support SXGA-class signals. Power-ON Reset When power applied, internal power-ON reset circuit operates initializing internal register flags their default settings. power-ON, supplies should applied simultaneously. Compensation Circuit compensation circuit built-in between OUTnA OUTnB pins. circuits where load resistance small capacitance required large, using compensation circuit allows total capacitance mounting area reduced. compensation circuit used, output OUTnA should connected OUTnB. electrical characteristics guaranteed OUTnB left open circuit. OUTnA OUTnA OUTnB OUTnB Figure Connection without compensation circuit Figure Connection with compensation circuit Reference Voltage (REF) REFn pins internal reference voltage outputs. capacitor connected between ground recommended stability movement. REF1, REF2, REF3 independent reference voltage outputs, have correspondence with settings CH-1, CH-2, CH-3. disable mode, they high impedance outputs. SEIKO CORPORATION SM5308BS USAGE PRECAUTIONS Slave Address (94h) Setting When slave address used, input must left open circuit. this case, external resistor should connected shown figure reduce risk malfunction I2C-BUS interface large external spikes other noise invaded from outside. recommended value 10k. Slave address Figure Slave address setting Power Supply Invest Timing SM5308BS uses 2-type power supply, analog (VCC1, VCC2, VCC3) digital (VDD). Therefore power supply pins should forced voltage same time power supply invested. case analog power supply digital simultaneously, composing system time-lag makes short time standard under need. voltage digital power supply comes higher than analog power supply, necessary voltage digital power supply make potential difference bellow 100mV compared with voltage analog one. SEIKO CORPORATION SM5308BS TYPICAL CHARACTERISTICS 5.0V, 5.0V, 25°C, 0.5Vp-p, RISET 1.8k, unless otherwise noted. Gain Group delay Frequency [MHz] Gain Frequency [MHz] -180 -270 -360 -450 -540 -630 Phase [deg] Phase Figure Gain Phase characteristics (12.5dB, filter bypass mode) Figure Gain Group delay characteristics (12.5dB, filter bypass mode) Gain Frequency [MHz] -180 -270 -360 -450 -540 -630 Phase [deg] Phase Gain Group delay Frequency [MHz] Figure Gain Phase characteristics (12.5dB, standard mode, FCDATA Figure Gain Group delay characteristics (12.5dB, standard mode, FCDATA Gain Frequency [MHz] -180 -270 -360 -450 -540 -630 Phase [deg] Gain [dB] Gain [dB] Phase Gain Group delay Frequency [MHz] Figure Gain Phase characteristics (12.5dB, half mode, FCDATA Figure Gain Group delay characteristics (12.5dB, half mode, FCDATA SEIKO CORPORATION Group delay [ns] Group delay [ns] Gain [dB] Gain [dB] Group delay [ns] Gain [dB] Gain [dB] SM5308BS Gain Frequency [MHz] -180 -270 -360 -450 -540 -630 Phase [deg] Phase Gain Group delay Frequency [MHz] Figure Gain Phase characteristics (12.5dB, standard mode, FCDATA 227) Figure Gain Group delay characteristics (12.5dB, standard mode, FCDATA 227) Gain Gain Frequency [MHz] -180 -270 -360 -450 -540 -630 Phase [deg] Phase Group delay Frequency [MHz] Figure Gain Phase characteristics (12.5dB, half mode, FCDATA 227) Figure Gain Group delay characteristics (12.5dB, half mode, FCDATA 227) SEIKO CORPORATION Group delay [ns] Gain [dB] Gain [dB] Group delay [ns] Gain [dB] Gain [dB] SM5308BS (Bypass mode) (Bypass mode) Phase [deg] Gain [dB] -180 -270 -360 -450 -540 Frequency [MHz] -630 Frequency [MHz] Figure Gain FCDATA, mode (12.5dB) FCDATA mode standard half standard half Figure Phase FCDATA, mode (12.5dB) FCDATA mode standard half standard half Group delay [ns] (Bypass mode) Frequency [MHz] Figure Group delay FCDATA, mode (12.5dB) FCDATA mode standard half standard half SEIKO CORPORATION SM5308BS [mA] [mA] 4.50 4.75 5.00 5.25 5.50 ICC2*2 ICC1*1 [°C] ICC2*2 ICC1*1 filter mode, FCDATA filter bypass mode filter mode, FCDATA filter bypass mode Figure ICC1, (12.5dB, FCDATA 255) FCDATA Figure ICC1, (12.5dB, FCDATA 255) 13.5 13.0 Gain [dB] [mA] 12.5 12.0 11.5 4.50 4.75 5.00 5.25 5.50 Figure ICC1 FCDATA (12.5dB) 13.5 Figure Gain (12.5dB) 13.0 Gain [dB] Gain [dB] [°C] 12.5 12.0 11.5 4.50 4.75 5.00 5.25 5.50 Figure Gain (12.5dB) Figure Gain (6.5dB) Gain [dB] [°C] Figure Gain (6.5dB) SEIKO CORPORATION SM5308BS VOUT VOUT Figure VOUT (OUT1A-B short) (6.5dB, filter mode, bias mode) VOUT Figure VOUT (OUT1A-B short) (12.5dB, filter mode, bias mode) VOUT Figure VOUT (OUT1A-B short) (6.5dB, filter bypass mode, bias mode) Figure VOUT (OUT1A-B short) (12.5dB, filter bypass mode, bias mode) SEIKO CORPORATION SM5308BS Please your attention following points time using products shown this document. products shown this document (hereinafter "Products") intended used apparatus that exerts harmful influence human lives defects, failure malfunction Products. Customers requested obtain prior written agreement such from SEIKO CORPORATION (hereinafter "NPC"). Customers shall solely responsible for, indemnify hold free harmless from, claims, damages, losses, expenses lawsuits, such without such agreement. reserves right change specifications Products order improve characteristic reliability thereof. makes claim warranty that contents described this document dose infringe intellectual property right other similar right owned third parties. Therefore, shall responsible such problems, even accordance with descriptions provided this document. descriptions including applications, circuits, parameters Products this document reference Products, shall guaranteed free from defect, inapplicability design mass-production products without further testing modification. Customers requested export re-export, directly indirectly, Products country entity compliance with violation national export administration laws, treaties, orders regulations. Customers requested appropriately take steps obtain required permissions approvals from appropriate government agencies. SEIKO CORPORATION 15-6, Nihombashi-kabutocho, Chuo-ku, Tokyo 103-0026, Japan Telephone: +81-3-6667-6601 Facsimile: +81-3-6667-6611 http://www.npc.co.jp/ Email: sales@npc.co.jp NC0507CE 2007.09 SEIKO CORPORATION Other recent searchesMC78L12F - MC78L12F MC78L12F Datasheet MBUS - MBUS MBUS Datasheet IEC1107 - IEC1107 IEC1107 Datasheet HYMD232M646C - HYMD232M646C HYMD232M646C Datasheet HF100-28 - HF100-28 HF100-28 Datasheet FLP-8 - FLP-8 FLP-8 Datasheet BSC019N02KS - BSC019N02KS BSC019N02KS Datasheet IEC61249-2-21 - IEC61249-2-21 IEC61249-2-21 Datasheet
Privacy Policy | Disclaimer |