| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
DC-DC CONVERTERS Single Triple Output Models Wide Input Ranges 12
Top Searches for this datasheet30W-40W DC-DC CONVERTERS Single Triple Output Models Wide Input Ranges 12V, Outputs Input Filters-Built-in Suppression UL/CSA/VDE/EN Safety Standards 850-1500V Input/Output Isolation Short-Circuit/Over-Voltage Protection Remote Load Sensing Remote Shutdown/Output Adjustment Six-Sided Metal Case 2-Year Warranty 700,000-Hour Minimum MTBF Nominal Max. Input Output Output Line/ Input Voltage Min.Nom.Max. Current Output Current Voltage Load Effi(V) Output Tolerance Reg. ciency CHARACTERISTICS Suppression input filter, standard. Base-Plate Temperature.Operating temperature +100°C, max.with built-in thermal shutdown. Isolation Voltage .D-input models: 1500V, input output, minute. B-input models: 850V, input output, minute. Output Adjustment.Primary output adjustable ±10%. Continuous Output Power .HD1-30 HD3-30 total output power should exceed 30W. HD140 HD3-40 total output power should exceed 40W. Maximum output current individual outputs triple output models appear ratings table. Minimum Load Requirement .Single output models, minimum. Triple output models, minimum output, minimum, auxiliary outputs. Output Noise Ripple output, mVpp, maximum. outputs, mVpp, maximum. (See Note Short-Circuit Protection .Cycle-by-cycle current limiting. Over-Voltage Protection output only: 125% rated output, typical. Single output models with outputs triple output models have latching OVP; RESET other models diode protected. Under-Voltage Lockout.Nom. Input (Typ.) (Typ.) 7.5V 8.5V 16.5V 17.5V 34.0V 35.5V Transient Response .200 recovery after half-load full load step change within regulation band with more than deviation. Frequency Operation .300 kHz. Remote Shutdown.CMOS open-collector compatible: 2.4V VIN(MAX); 0.8V less. Logic reference -VIN. Temperature Range.-40°C +85°C (ambient). Package Power De-Rating graph. Temperature Coefficient .±0.02%/°C over entire operating temperature range. Relative Humidity 95%, non-condensing. Altitude 10,000 feet. Cooling .Convection cooling adequate. Moving recommended operation confined area. Package Power De-Rating graph. Storage Temperature.-40°C +100°C. Storage Humidity.0 95%, non-condensing. Mean Time Between Failures.>700,000 hours. (See Note Model DC-DC Singles HD1-30-5A HD1-30-5B HD1-30-5D HD1-30-12A HD1-30-12B HD1-30-12D HD1-30-15A HD1-30-15B HD1-30-15D 3.16 1.52 0.75 3.09 1.51 0.75 3.01 1.51 0.73 6.00 6.00 6.00 2.50 2.50 2.50 2.00 2.00 2.00 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% DC-DC Triples HD3-30-1A 3.21 6.00 0.50 0.50 6.00 0.50 0.50 6.00 0.50 0.50 6.00 0.40 0.40 6.00 0.40 0.40 6.00 0.40 0.40 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 0.3% 5.0% 6.0% 0.3% 5.0% 6.0% 0.3% 5.0% 6.0% 0.3% 5.0% 7.0% 0.3% 5.0% 7.0% 0.3% 5.0% 7.0% HD3-30-1B 1.54 HD3-30-1D 0.76 HD3-30-2A 3.21 HD3-30-2B 1.54 HD3-30-2D 0.76 DC-DC Singles HD1-40-5A HD1-40-5B HD1-40-5D HD1-40-12A HD1-40-12B HD1-40-12D HD1-40-15A HD1-40-15B HD1-40-15D 4.20 2.03 1.00 4.12 2.01 1.00 4.02 2.01 0.97 8.00 8.00 8.00 3.33 3.33 3.33 2.67 2.67 2.67 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% HD3-30 models with tightly regulated auxiliary outputs available. more information, contact Power General applications engineering. POWER GENERAL Will Drive Canton, 02021 Phone 781-828-6216 781-830-1155 Email power@nidecpg.com http://www.nidec.com 30W-40W DC-DC CONVERTERS Model Nominal Max. Input Output Output Line/ Input Voltage Min.Nom.Max. Current Output Current Voltage Load Effi(V) Output Tolerance Reg. ciency PACKAGE POWER DE-RATING Flat Base Plate DC-DC Triples HD3-40-1A 4.27 HD3-40-1B 2.06 HD3-40-1D 1.02 8.00 0.50 0.50 8.00 0.50 0.50 8.00 0.50 0.50 8.00 0.40 0.40 8.00 0.40 0.40 8.00 0.40 0.40 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 1.0% 2.5% 2.5% 0.3% 5.0% 6.0% 0.3% 5.0% 6.0% 0.3% 5.0% 6.0% 0.3% 5.0% 7.0% 0.3% 5.0% 7.0% 0.3% 5.0% 7.0% PACKAGE POWER DE-RATING Cross-Cut Heat Sink HD3-40-2A 4.27 HD3-40-2B 2.06 HD3-40-2D 1.02 HD3-40 models with tightly regulated auxiliary outputs available. more information, contact Power General applications engineering. SERIES Dimensions shown inches. Tolerances 0.00 ±0.01 inch. 0.000 ±0.005 inch. HD1-40 HD3-40 models normally supplied with flat base plate. specify HD1-40 HD3-40 model with optional cross-cut heat sink, letter part number (e.g., HD1-40-5AH). Module weight: HD1-30, HD3-30, HD1-40 HD3-40, heat sink (113g). HD1-40 HD3-40 with cross-cut heat sink (142g). Pin-Out HD1-30 HD1-40 +VIN Case Remote On/Off Output Adjust +V1OUT V1OUT +Sense Sense HD3-40 HD3-40 +VIN Case Remote On/Off Output Adjust V1OUT Return V2OUT V3OUT Notes external input line fuse recommended: HD1-30 HD3-30 models with input, 6.0A/125V slow-blow fuse. HD1-30 HD3-30 models with input, 3.0A/125V slow-blow fuse. HD1-30 HD3-30 models with input, 2.0A/125V slow-blow fuse. HD1-40 HD3-40 models with input, 8.0A/125V slow-blow fuse. HD1-40 HD3-40 models with input, 4.0A/125V slow-blow fuse. HD1-40 HD3-40 models with input, 2.0A/125V slow-blow fuse. Peak-to-peak metering equipment must have frequency response with probes cables that maintain frequency response MHz. Output ripple spikes measured directly output terminals dc-to-dc converter with ceramic capacitor. instruments' probe ground bands must make direct contact with output return common terminal converter order prevent erroneous noise measurements. measurements nominal input, full load, +25°C unless otherwise specified. MTBF calculated using parts stress method MILHDBK 217F (ground benign, +25°C). Output Adjustment POWER GENERAL Will Drive Canton, 02021 Phone 781-828-6216 781-830-1155 Email power@nidecpg.com http://www.nidec.com Other recent searchesTR14ASR1N - TR14ASR1N TR14ASR1N Datasheet TDA7299 - TDA7299 TDA7299 Datasheet SMUA60 - SMUA60 SMUA60 Datasheet PDI-E833 - PDI-E833 PDI-E833 Datasheet OPA3692 - OPA3692 OPA3692 Datasheet M74HC640 - M74HC640 M74HC640 Datasheet AN-303 - AN-303 AN-303 Datasheet AM27SGC09 - AM27SGC09 AM27SGC09 Datasheet 2SK4179GS - 2SK4179GS 2SK4179GS Datasheet
Privacy Policy | Disclaimer |