| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
MODULAR DC-DC CONVERTERS Wide Input Voltage Ranges Input Filters-
Top Searches for this datasheet5W-20W MODULAR DC-DC CONVERTERS Wide Input Voltage Ranges Input Filters-Built-in Suppression Model Includes Remote Shutdown Remote Load Sensing Remote Output Voltage Adjustment Short-Circuit/Over-Voltage Protection Compact Packages Six-Sided Shielding High Efficiency Ratings 2-Year Warranty 200,000-Hour Minimum MTBF WITH NON-ISOLATED CHARACTERISTICS Suppression.Pi input filter, standard. Reflected Ripple Current.DCU1-5, mApp, max. DCU1-20, mApp, max. Continuous Output Power.See output voltage/current ratings. Output Voltage Tolerance.DCU1-5, ±2%. DCU1-20WR/5, ±2%. other DCU1-20 models, ±1%. External Output Trim .DCU1-20-WR/5, +5%; other DCU120 models, ±5%. Output Noise Ripple.DCU1-5, mVpp, max. DCU1-20, mVpp, max. (Note Short-Circuit Protection.DCU1-5, pulsed overload type. DCU1-20, cycle-by-cycle current limiting; internal thermal shutdown. Over-Voltage Protection.130% rated output voltage, typ. Reverse Voltage Protection .Internal shunt diode. Transient Response .DCU1-5, recovery within regulation band after step load change with more than deviation. DCU1-20, recovery within regulation band after step load change with more than deviation. Frequency Operation .DCU1-5, kHz. DCU1-20, kHz. Remote Shutdown .DCU1-20, 0.5V VIN(MAX) open circuit; 0.25V less. Standby Mode Current Drain .DCU1-20 series, less than 24V. Temperature Range .-25°C +70°C, de-rating. Temperature Coefficient .±0.02%/°C over entire operating temperature range. Relative Humidity 95%, non-condensing. Altitude 10,000 feet. Cooling .Convection cooling adequate. Moving recommended operation confined area. Storage Temperature .-40°C +100°C. Storage Humidity 95%, non-condensing. Mean Time Between Failures .DCU1-5, >250,000 hours. DCU1-20, >200,000 hours. (Note Input Current Max. Input Voltage Full Output Output Min. Nom.Max. Load Load Voltage Current Line Load Effi(V) Reg. Reg. ciency Model DC-DC Single Output DCU1-5-WR/5 0.025 0.600 5.10 0.5% 0.5% DC-DC Single Output DCU1-20-WR/5 0.015 1.020 5.05 0.5% 1.0% Notes external input line fuse recommended: DCU1-5, 1.0A/125V slow-blow fuse. DCU1-20, 5A/125V slow-blow fuse. Peak-to-peak metering equipment must have frequency response with probes cables that maintain frequency response MHz. Output ripple spikes measured directly output terminals converter with ceramic capacitor. probe ground band must make direct contact with output return common terminal converter prevent erroneous noise measurements. measurements nominal input, full load, +25°C unless otherwise specified. MTBF calculated using parts stress method MIL-HDBK 217F (ground benign, +25°C). POWER GENERAL Will Drive Canton, 02021 Phone 781-828-6216 781-830-1155 Email power@nidecpg.com http://www.nidec.com 5W-20W MODULAR DC-DC CONVERTERS WITH NON-ISOLATED DCU1-5 SERIES Dimensions shown inches. Tolerances 0.00 ±0.02 inch. 0.000 ±0.005 inch. Module weight (42.5g). DCU1-20 SERIES Dimensions shown inches. Tolerances 0.00 ±0.02 inch. 0.000 ±0.005 inch. Module weight (213g). OUTPUT TRIM Pin-Out Model Selection Guide Series Number Outputs Output Power Output Voltage Input Voltage Wide Range) DCU1-5 Series +VIN +VOUT VOUT DCU1-20 Series +VIN +Sense Output Trim Sense +VOUT VOUT Remote On/Off POWER GENERAL Will Drive Canton, 02021 Phone 781-828-6216 781-830-1155 Email power@nidecpg.com http://www.nidec.com Other recent searchesSR202 - SR202 SR202 Datasheet SR206 - SR206 SR206 Datasheet MM342XX - MM342XX MM342XX Datasheet MGM101A - MGM101A MGM101A Datasheet
Privacy Policy | Disclaimer |