INNOVATION EXCELLENCE
Dual Output
Models
High-Efficiency, Smaller-Package 25-40 Watt, DC/DC Converters
Features
Higher operating temperatures Fully potted Designed meet UL1950 EN60950 (basic insulation) mark available (75V-input models) Fully isolated, 1500Vdc guaranteed 25/30/35/40W output power Standard pinout! Smaller size! package fits footprint ±5V, ±12V ±15V outputs Four input voltage ranges: 10-36V, 18-36V 18-75V, 36-75V High efficiencies 88%) Fully protected VOUT trim on/off control Modifications customs OEM's
DATEL's Models fully potted, 25-40 Watt, dual-output DC/DC converters designed meet UL1950 EN60950 safety standards. combination BMP's higher efficiencies thermally conductive potting compound enables these devices achieve higher operating temperatures without derating. "footprint" conforms standard pinout geometries most devices space savings) while delivering more power (40W 25W). Applicable wide range telecom, computer other applications, Model DC/DC's offer ±5V, ±12V ±15V outputs. They operate from four different input voltage ranges with total available output being function selected range. "Q12" models operate from 10-36V deliver 25W. "Q48" models operate from 18-75V deliver 30W. "D24" "D48" models, input ranges output powers 1836V 36-75V 40W, respectively. These devices employ corrosion-resistant metal cases with plastic headers. Heat-generating transformer cores power semiconductors mounted directly cases, which have threaded inserts optional add-on heat sinks mounting. Temperature derating information provided operation with without heat sinks forced flow. devices feature input filters, input overvoltage shutdown, output overvoltage protection, output current limiting, thermal shutdown. CSA, compliance testing currently progress (75V-input devices will marked) full EMI/EMC characterizations. Contact DATEL latest available information.
+VIN
+VOUT
-VIN
COMMON
-VIN -VOUT
CASE ON/OFF CONTROL (SYNC) REFERENCE ERROR AMPLIFIER
CONTROLLER
OPTO ISOLATION
TRIM
Figure Simplified Schematic
DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 Email: sales@datel.com Internet: www.datel.com
Series
Performance Specifications Ordering Guide
Output Model
BMP-5/4-Q12 BMP-5/4-D24 BMP-5/4-Q48 BMP-5/4-D48 BMP-12/1.65-Q12 BMP-12/1.65-D24 BMP-12/1.65-Q48 BMP-12/1.65-D48 BMP-15/1.3-Q12 BMP-15/1.3-D24 BMP-15/1.3-Q48 BMP-15/1.3-D48
DUAL
OUTPUT
DC/DC
CONVERTERS
Input Regulation (Max.) Load Line
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
VOUT (Volts)
IOUT (Amps)
±1.65 ±1.65 ±1.65 ±1.65 ±1.3 ±1.3 ±1.3 ±1.3
(mVp-p) Typ. Max.
Nom. (Volts)
Range (Volts)
10-36 18-36 18-75 36-75 10-36 18-36 18-75 36-75 10-36 18-36 18-75 36-75
(mA)
15/1225 15/1696 25/735 20/980 20/1224 15/1667 15/727 15/948 20/1225 15/1648 15/735 20/934
Efficiency Min. Typ.
Package (Case, Pinout)
C11, C11, C11, C11, C11, C11, C11, C11, C11, C11, C11, C11,
Typical +25°C under nominal line voltage balanced "full-load" conditions unless otherwise noted. devices, "full load" function each device's input voltage range. Output Power Considerations Technical Notes more details. Ripple/Noise (R/N) measured over 20MHz bandwidth. Balanced loads, 100% load. Nominal line voltage, no-load/full-load conditions.
PART NUMBER STRUCTURE
Output Configuration: Bipolar Fully Potted Metal Package Nominal Output Voltages: Volts Input Voltage Range: 10-36 Volts (24V nominal) 18-36 Volts (24V nominal) 18-75 Volts (48V nominal) 36-75 Volts (48V nominal) Maximum Output Current Amps from each output
shown below, Model DC/DC Converters classified output power. dual-output devices, total output power from outputs exceed rated power. example, "Q48" models have maximum output power 30W. Therefore, +Output sourcing Watts, -Output limited sourcing Watts ensuring total output power does exceed Watts.
Model Maximum Output Power Watts Watts Watts Watts
Connections
3.04 (77.22) METAL CASE INSULATED BASE 0.040 ±0.002 DIA. (1.016 ±0.051) 2.500 (63.50) 0.27 (6.86)
Optional Heat Sink (Part Number HS-23)
3.00 (76.20) 0.20 (5.08) 2.600 (66.04) 0.40 (10.16)
0.55 (13.97) 0.20 (5.08)
Case
0.42 (10.67)
1.200 (30.48)
1.600 2.04 (40.64) (51.82) 0.400 (10.16)
Function -Input +Input Case On/Off Control* -Output Common +Output Trim
note next page.
1.200 (30.48)
2.00 (50.80)
THREADED INSERTS #4-40 THRU
VIEW
BOTTOM VIEW
0.120 DIA. (3.048) PLACES)
0.10 (2.54) 0.50 (12.70)
0.22 (5.59)
2.600 (66.04) DIMENSIONS INCHES (MM)
0.22 (5.59)
MATERIAL: BLACK ANODIZED ALUMINUM MOUNTING SCREWS 0.009 (0.229) THERMAL INCLUDED
DUAL
OUTPUT
DC/DC
CONVERTERS
Models
Performance/Functional Specifications
Typical +25°C under nominal line voltage "full-load" conditions, unless noted.
Input
Input Voltage Range: Models Models Models Models Input Current Input Filter Type Overvoltage Shutdown: Models Models Reverse-Polarity Protection On/Off Control (Pin VOUT Accuracy (50% load) Temperature Coefficient Ripple/Noise (20MHz Line/Load Regulation Efficiency Isolation Voltage Isolation Capacitance Current Limiting Overvoltage Protection Transient Response (50% load step) Switching Frequency Operating Temperature (ambient): Without Derating With Derating Maximum Case Temperature Storage Temperature Dimensions Shielding Case Connection Case Material Material Weight 10-36 Volts (24V nominal) 18-36 Volts (24V nominal) 18-75 Volts (48V nominal) 36-75 Volts (48V nominal) Ordering Guide Volts Volts (Instantaneous, maximum) high open) Storage Temperature Input Voltage: Q12/D24 Models Q48/D48 Models
Absolute Maximum Ratings
Volts Volts Current must <6A. Brief duration only. Fusing recommended. Volts, limited duration Volts, limited duration Volts, limited duration Current limited. Max. current short-circuit duration model dependent. +105°C +300°C
Input Reverse-Polarity Protection Output Overvoltage Protection Outputs ±12V Outputs ±15V Outputs Output Current
Output
±1%, maximum ±0.02% Ordering Guide Ordering Guide Ordering Guide 1500Vdc, minimum 620pF Continuous, auto-recovery Zener/transorb clamps, magnetic feedback
Lead Temperature (soldering, sec.)
These stress ratings. Exposure devices these conditions adversely affect long-term reliability. Proper operation under conditions other than those listed Performance/Functional Specifications Table implied.
TECHNICAL NOTES
Floating Outputs Since these isolated DC/DC converters, their outputs "floating." model configured produce output 10V, (for ±5V, ±12V ±15V models, respectively) applying load across +Output -Output (pins with either output grounded. Common (pin should left open. Minimum loading recommended under these conditions. total output voltage span externally trimmed described below. Filtering Noise Reduction 25-40 Watt DC/DC Converters achieve their rated ripple noise specifications without external input/output capacitors. critical applications, input/output ripple noise further reduced installing electrolytic capacitors across input terminals and/or low-ESR tantalum electrolytic capacitors across output terminals. Output capacitors should connected between their respective output (pin Common (pin Figure caps should located close converters possible. Typical values listed below. many applications, using values greater than those listed will yield better results. Reduce Input Ripple "Q12, D24" Models "Q48, D48" Models Reduce Output Ripple Outputs ±12/15V Outputs 47µF, 10µF, 100V 47µF, 10V, 22µF, 20V,
Dynamic Characteristics
300µsec max. ±1.5% final value 125kHz (±10%)
Environmental
+60°C (Model dependent) +90°C (See Derating Curves) +90°C +105°C
Physical
2.04" 3.04" 0.55" (51.8 77.2 14mm) 5-sided Aluminum, black anodized finish with plastic header Brass, solder coated ounces (170 grams)
These converters require minimum loading each output maintain specified regulation. Operation under no-load conditions will damage these devices; however they meet listed specifications. "Full load" varies part number determined input voltage range indicated part number suffix. Technical Notes Output Power Considerations. Application-specific input/output filtering recommended perhaps added internally upon request. Contact DATEL Applications Engineering details. Applying voltage On/Off Control when input power applied converter cause permanent damage converter. desired, On/Off Control function replaced with Sync function. page this data sheet more details. Listed specification input-to-output isolation. Input-to-case output-to-case isolation 1000Vdc, minimum.
critical, space-sensitive applications, DATEL able tailor internal input/output filtering these devices meet your specific requirements. Contact Applications Engineering Group additional details. Input Fusing Range Fuse Value
Series
DUAL
OUTPUT
DC/DC
CONVERTERS
Temperature Derating Electrical Performance Curves
Models Watts)
Output Power (Watts)
Output Power (Watts)
Natural Convection Cooling Linear Feet Minute Linear Feet Minute
Natural Convection Cooling Linear Feet Minute Linear Feet Minute
Ambient Temperature (°C)
Ambient Temperature (°C)
Figure Temperature Derating Without Heat Sink
Figure Temperature Derating With Heat Sink
Models Watts)
Output Power (Watts)
Output Power (Watts)
Natural Convection Cooling Linear Feet Minute Linear Feet Minute
Natural Convection Cooling Linear Feet Minute Linear Feet Minute
Ambient Temperature (°C)
Ambient Temperature (°C)
Figure Temperature Derating Without Heat Sink
Figure Temperature Derating With Heat Sink
Models Watts)
Output Power (Watts)
Output Power (Watts)
Natural Convection Cooling Linear Feet Minute Linear Feet Minute
Natural Convection Cooling Linear Feet Minute Linear Feet Minute
Ambient Temperature (°C)
Ambient Temperature (°C)
Figure Temperature Derating Without Heat Sink
Figure Temperature Derating With Heat Sink
DUAL
OUTPUT
DC/DC
CONVERTERS
Models
Temperature Derating Electrical Performance Curves
Models Watts)
Output Power (Watts)
Output Power (Watts)
Natural Convection Cooling Linear Feet Minute Linear Feet Minute
Natural Convection Cooling Linear Feet Minute Linear Feet Minute
Ambient Temperature (°C)
Ambient Temperature (°C)
Figure Temperature Derating Without Heat Sink
Figure Temperature Derating With Heat Sink
Output Power Model, dual-output DC/DC converters incorporate design tradeoff between total available output power input voltage range. total available power function both nominal input voltage "width" input voltage range. given nominal input (24V 48V), narrower ranges (2:1 4:1) have more available power. given "width" input range (2:1 4:1), higher nominal inputs (48V 24V) have more available power. Each device, indicated part-number suffix (Q12, Q48, D48) total output power limitation Watts, respectively. Observing these power limitations user's responsibility. indicated Part Number Structure, each ±5V, ±12V ±15V device capable sourcing ±1.65 ±1.3 Amps, respectively. Users have flexibility loading either output these limits; however must extremely careful exceed total output power rating given device. example, device with power rating (BMP-5/4-Q48) sourcing from output (representing +Output power), that device only supply additional Amps) from -Output. consequence this "power-allocation" flexibility, definition "full load," condition under which performance specifications tested listed, ambiguous. following table lists positive negative output currents that DATEL uses define each device's "full load."
Model Number BMP-5/4-Q12 BMP-5/4-Q48 BMP-5/4-D24 BMP-5/4-D48 BMP-12/1.65-Q12 BMP-12/1.65-Q48 BMP-12/1.65-D24 BMP-12/1.65-D48 BMP-15/1.3-Q12 BMP-15/1.3-Q48 BMP-15/1.3-D24 BMP-15/1.3-D48
Voltage Range 10-36V 18-75V 18-36V 36-75V 10-36V 18-75V 18-36V 36-75V 10-36V 18-75V 18-36V 36-75V
Output Power Watts Watts Watts Watts Watts Watts Watts Watts Watts Watts Watts Watts
Definition "Full Load" Specification Purposes Currents ±2.5A (25W) (30W) ±3.5A (35W) (40W) ±12V Currents ±1.04A (24.96W) ±1.25A (30W) ±1.46A (35W) ±1.67A (40.1W) ±15V Currents ±833mA (24.99W) (30W) ±1.17A (35.1W) ±1.33A (39.9W)
Table Output Currents Comprising "Full Load"
Series
On/Off Control (Standard) On/Off Control (pin used remote on/off operation. shown Figure control internal pull-up resistor approximately 10V. converter designed that enabled when control left open (normal mode) disabled when control pulled less than +0.8V relative -Input, Dynamic control on/off function best accomplished with mechanical relay open-collector/open-drain drive circuit (optically isolated appropriate). drive circuit should obviously able sink approximately when activated withstand more than Volts when deactivated. Applying external voltage when input power applied converter cause permanent damage converter. on/off control function, however, designed such that converter disabled (pin pulled low) while input power ramping then "released" once input stabilized. Under these circumstances, takes approximately 30ms output fully loaded DC/DC ramp settle within final value after converter been turned Synchronization (Optional) critical applications employing multiple switching DC/DC converters, desirable intentionally synchronize switching selected converters system noise reduced with notch filtering) purposely desynchronize converters lessen current-carrying requirements intermediate buses). DC/DC Converters have been designed that On/Off Control function replaced with Sync function. This change implemented DATEL during product assembly process. Contact Applications Engineering Group additional details. synchronize switching multiple converters configured with Sync function, external clock applied each converter. clock should square wave referenced -Input (logic high Volts, 250µA max.; logic +0.8 Volts, 70µA max.) with maximum 1µsec "high" duration. frequency synchronizing clock should higher than that individual converter. Therefore, should 145kHz ±5kHz. Output Trimming total output voltage span, from +Output (pin -Output (pin trimmed single trimpot fixed resistor. trimpot should connected shown Figure with wiper connected (Trim). trimpot also used determine value single fixed resistor which connected between (Trim) (+Output) trim "down" output voltages, between pins (Trim) (-Output) trim "up" output voltages. Fixed resistors should metal-film types with absolute TCR's less than 100ppm/°C ensure stability.
DUAL
OUTPUT
DC/DC
CONVERTERS
+10V +INPUT 10k9
ON/OFF CONTROL -INPUT
Figure Driving On/Off Control
+OUTPUT +INPUT -INPUT COMMON
COUT COUT
-OUTPUT
Figure Using External Capacitors Reduce Input/Output Ripple/Noise
+OUTPUT +INPUT COMMON TRIM -INPUT
LOAD 20k9 5-10 Turns
LOAD
-OUTPUT
Figure Trim Connections Using Trimpot
Case Connection Unlike most other DC/DC converters, DC/DC's have their metal case connected their input pins. "uncommitted" case connected which, depending your system configuration, should connected either +Input (pin -Input (pin
INNOVATION EXCELLENCE
ISO-9001 REGISTERED DATEL DATEL DATEL DATEL
DS-0411
11/01
DATEL, Inc. Cabot Boulevard, Mansfield, 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: sales@datel.com Data Sheet Back: (508) 261-2857
(UK) LTD. Tadley, England Tel: (01256)-880444 S.A.R.L. Montigny Bretonneux, France Tel: 01-34-60-01-01 GmbH Germany Tel: 89-544334-0 Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025
DATEL makes representation that products circuits described herein, other technical information contained herein, will infringe upon existing future patent rights. descriptions contained herein imply granting licenses make, use, sell equipment constructed accordance therewith. Specifications subject change without notice. DATEL logo registered DATEL, Inc. trademark.

Other recent searches


VME64 - VME64   VME64 Datasheet
TM7200TM - TM7200TM   TM7200TM Datasheet
PT6910 - PT6910   PT6910 Datasheet
OPA2684 - OPA2684   OPA2684 Datasheet
MC68HC12DA128 - MC68HC12DA128   MC68HC12DA128 Datasheet
LPT3331-PF - LPT3331-PF   LPT3331-PF Datasheet
AT91SAM7A3 - AT91SAM7A3   AT91SAM7A3 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive